• 제목/요약/키워드: peri implantitis

검색결과 143건 처리시간 0.023초

레이저 처리후 임프란트 표면 변화에 관한 연구 (The Evaluation of the atomic composition and the surface roughness of Titanium Implants following Various Laser treatment with air-powder abrasive)

  • 김태정;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제32권3호
    • /
    • pp.615-630
    • /
    • 2002
  • Various long-term studies have shown that titanium implants as abutments for different types of prostheses have become a predictable adjunct in the treatment of partially or fully edentulous patients. The continuous exposure of dental implants to the oral cavity with all its possible contaminants creates a problem. A lack of attachment, together with or caused by bacterial insult, may lead to peri-implantitis and eventual implant failure. Removal of plaque and calculus deposits from dental titanium implants with procedures and instruments originally made for cleaning natural teeth or roots may cause major alterations of the delicate titanium oxide layer. Therefore, the ultimate goal of a cleaning procedure should be to remove the contaminants and restore the elemental composition of the surface oxide without changing the surface topography and harming the surrounding tissues. Among many chemical and mechanical procedure, air-powder abrasive have been known to be most effective for cleaning and detoxification of implant surface. Most of published studies show that the dental laser may be useful in the treatment of pen-implantitis. $CO_2$ laser and Soft Diode laser were reported to kill bacteria of implant surface. The purpose of this study was to obtain clinical guide by application these laser to implant surface by means of Non-contact Surface profilometer and X-ray photoelectron spectroscopy(XPS) with respect to surface roughness and atomic composition. Experimental rough pure titanium cylinder models were fabricated. All of them was air-powder abraded for 1 minute and they were named control group. And then, the $CO_2$ laser treatment under dry, hydrogen peroxide and wet condition or the Soft Diode laser treatment under Toluidine blue O solution condition was performed on the each of the control models. The results were as follows: 1. Mean Surface roughness(Ra) of all experimental group was decreased than that of control group. But it wasn't statistically significant. 2. XPS analysis showed that in the all experimental group, titanium level were decreased, when compared with control group. 3. XPS analysis showed that the level of oxygen in the experimental group 1, 3($CO_2$ laser treatment under dry and wet condition) and 4(Soft Diode laser was used under toluidine blue O solution) were decreased, when compared with control group. 4. XPS analysis showed that the atomic composition of experimental group 2($CO_2$ laser treatment under hydrogen peroxide) was to be closest to that of control group than the other experimental group. From the result of this study, this may be concluded. Following air-powder abrasive treatment, the $CO_2$ laser in safe d-pulse mode and the Soft Diode laser used with photosensitizer would not change rough titanium surface roughness. Especially, $CO_2$ laser treatment under hydrogen peroxide gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

골유착된 임프란트 제거의 최신지견 (Recent Advances of Osseointegrated Implants Removal)

  • 김남윤
    • 대한치과의사협회지
    • /
    • 제54권4호
    • /
    • pp.258-273
    • /
    • 2016
  • In spite of appropriate treatment of peri-implantitis, the peri-implant bone loss was keep going, the clinician should remove the osseointegrated implant. the conventional methods are like a extraction of natural teeth, and use of trephine drills. In these days, many exclusive instruments are invented by implant companies. these instruments can make easy, least invasive, less traumatic removal of osseointegrated implants. In generally peri-implant bone loss progress steadily less sign and symptoms that the patient do not want to remove their implants. However, the failure of dental implant is big burden to clinicians and also patients. In the dental implant treatment, there is no 'failure' but only is 'replacement' or 'change'.

  • PDF

임상가를 위한 특집 1 - Peri-implant disease를 방지하기 위한 Supportive Periodontal Therapy(SPT)의 중요성 (The importance of SPT(Supportive Periodontal Therapy) for prevention of peri-implant disease)

  • 박수정
    • 대한치과의사협회지
    • /
    • 제51권12호
    • /
    • pp.630-636
    • /
    • 2013
  • During the past decade, the use of osseointegrated implants as a foundation for prosthetic replacement of missing teeth has become highly predictable and successful. SPT(Supportive Periodontal Therapy) identified as regular visits to the therapist for periodontal control and maintenance in a well-organized scheme, the number of appointments per year following a pre-designed subject-tooth/implant-site risk assessment method. Peri-implant disease was a frequent finding in subjects having natural healthy dentition and in subjects without periodontitis. Supportive periodontal program were found to be strongly related to implant survival. This study demonstrates that regular maintenance reduces the risk for peri-implant inflammation significantly as compared with irregular maintenance. This underlines the value of the SPT in enhancing the long-term outcomes of implant therapy, particularly in subjects affected by periodontitis, in order to control reinfection and limit biological complications. It is highly recommended to maintain implant patients under a strict supportive periodontal treatment protocol that might contribute to implant survival, and regular maintenance reduces the risk for periimplant inflammation significantly as compared with irregular maintenance. Ideally, patients may be informed on the beneficial effect of a regular patient-related post-therapy care before implant insertion.

Mechanical and biological complication rates of the modified lateral-screw-retained implant prosthesis in the posterior region: an alternative to the conventional Implant prosthetic system

  • Lee, Jae-Hong;Lee, Jong-Bin;Kim, Man-Yong;Yoon, Joon-Ho;Choi, Seong-Ho;Kim, Young-Taek
    • The Journal of Advanced Prosthodontics
    • /
    • 제8권2호
    • /
    • pp.150-157
    • /
    • 2016
  • PURPOSE. The modified lateral-screw-retained implant prosthesis (LSP) is designed to combine the advantages of screw- and cement-retained implant prostheses. This retrospective study evaluated the mechanical and biological complication rates of implant-supported single crowns (ISSCs) inserted with the modified LSP in the posterior region, and determined how these complication rates are affected by clinical factors. MATERIALS AND METHODS. Mechanical complications (i.e., lateral screw loosening [LSL], abutment screw loosening, lateral screw fracture, and ceramic fracture) and biological complications (i.e., peri-implant mucositis [PM] and peri-implantitis) were identified from the patients' treatment records, clinical photographs, periapical radiographs, panoramic radiographs, and clinical indices. The correlations between complication rates and the following clinical factors were determined: gender, age, position in the jaw, placement location, functional duration, clinical crown-to-implant length ratio, crown height space, and the use of a submerged or nonsubmerged placement procedure. RESULTS. Mechanical and biological complications were present in 25 of 73 ISSCs with the modified LSP. LSL (n=11) and PM (n=11) were the most common complications. The incidence of mechanical complications was significantly related to gender (P=.018). The other clinical factors were not significantly associated with mechanical and biological complication rates. CONCLUSION. Within the limitations of this study, the incidence of mechanical and biological complications in the posterior region was similar for both modified LSP and conventional implant prosthetic systems. In addition, the modified LSP is amenable to maintenance care, which facilitates the prevention and treatment of mechanical and biological complications.

Evaluation of the effectiveness of diode laser therapy in conjunction with nonsurgical treatment of periimplantitis

  • Dicle Altindal;Eylem Ayhan Alkan;Metin Calisir
    • Journal of Periodontal and Implant Science
    • /
    • 제53권5호
    • /
    • pp.376-387
    • /
    • 2023
  • Purpose: Peri-implantitis (PI) is an inflammatory condition associated with the destruction of bone tissue around a dental implant, and diode lasers can be used to treat this disease. In this study, we aimed to evaluate the effectiveness of a 940-nm diode laser for the nonsurgical treatment of PI. Methods: Twenty patients (8 women and 12 men) were enrolled in a split-mouth randomized controlled study. In the control group (CG), mechanical debridement with titanium curettes accompanied by airflow was performed around the implants. The test group (TG) was treated similarly, but with the use of a diode laser. Clinical measurements (plaque index, gingival index [GI], probing pocket depth [PPD], bleeding on probing [BOP], clinical attachment level, and interleukin-1β [IL-1β] in the peri-implant crevicular fluid) were evaluated and recorded at baseline and 3 months. IL-1β levels were determined using the enzyme-linked immunosorbent assay method. Results: The symptoms were alleviated in both groups at 3 months as assessed through clinical measurements. GI, BOP, and PPD were significantly lower in the TG than in the CG (P<0.05). The IL-1β level increased post-treatment in both groups, but this increase was only statistically significant (P<0.05) in the CG. Conclusions: The diode laser enabled improvements in clinical parameters in the periimplant tissue. However, it did not reduce IL-1β levels after treatment. Further studies about the use of diode lasers in the treatment of PI will be necessary to evaluate the effects of diode lasers in PI treatment.

Evaluation of health screening data for factors associated with peri-implant bone loss

  • Hyunjong Yoo;Jun-Beom Park;Youngkyung Ko
    • Journal of Periodontal and Implant Science
    • /
    • 제52권6호
    • /
    • pp.509-521
    • /
    • 2022
  • Purpose: Systemic health has a profound effect on dental treatment. The aim of this study was to evaluate peri-implant bone loss and health screening data to discover factors that may influence peri-implant diseases. Methods: This study analyzed the panoramic X-rays of patients undergoing health screenings at the Health Promotion Center at Seoul St. Mary's Hospital in 2018, to investigate the relationship between laboratory test results and dental data. The patients' physical data, such as height, weight, blood pressure, hematological and urine analysis data, smoking habits, number of remaining teeth, alveolar bone level, number of implants, and degree of bone loss around the implant, were analyzed for correlations. Their associations with glycated hemoglobin, glucose, blood urea nitrogen (BUN), creatinine, and severity of periodontitis were evaluated using univariate and multivariate regression analysis. Results: In total, 2,264 patients opted in for dental health examinations, of whom 752 (33.2%) had undergone dental implant treatment. These 752 patients had a total of 2,658 implants, and 129 (17.1%) had 1 or more implants with peri-implant bone loss of 2 mm or more. The number of these implants was 204 (7%). Body mass index and smoking were not correlated with peri-implant bone loss. Stepwise multivariate regression analysis revealed that the severity of periodontal bone loss (moderate bone loss: odds ratio [OR], 3.154; 95% confidence interval [CI], 1.175-8.475 and severe bone loss: OR, 7.751; 95% CI, 3.003-20) and BUN (OR, 1.082; 95% CI, 1.027-1.141) showed statistically significant predictive value. The severity of periodontitis showed greater predictive value than the biochemical parameters of blood glucose, renal function, and liver function. Conclusions: The results of this study showed that periodontal bone loss was a predictor of peri-implant bone loss, suggesting that periodontal disease should be controlled before dental treatment. Diligent maintenance care is recommended for patients with moderate to severe periodontal bone loss.

임플란트 보철물의 합착에 대한 문헌고찰 (A literature review on cementation of implant prosthesis)

  • 이은석;고경호;허윤혁;박찬진;조리라
    • 대한치과보철학회지
    • /
    • 제54권4호
    • /
    • pp.458-467
    • /
    • 2016
  • 시멘트유지형 임플란트 보철물은 교합과 심미적인 측면에서 상당한 장점을 가지지만 시멘트잔사가 남을 경우 임플란트주위염을 유발하는데 대부분 후기 증상으로 발현되며 특히 제거의 어려움과 시멘트잔사로 인한 임플란트주위염은 임플란트의 예후를 위협하는 요인이 될 수 있다. 그러므로 사용목적에 맞는 유지력을 가지는 시멘트를 선택하는 것이 필요하다. 일반적으로 레진시멘트, 폴리카복실레이트시멘트, RMGI 시멘트가 GI 시멘트나 ZPC보다 높은 유지력을 가지며 임시합착제는 열순환 후에는 유지력이 낮아진다. 시멘트 외에도 지대주의 높이와 경사도, 지대주의 수 및 분포도 유지력에 영향을 줄 수 있다. 무엇보다 목적에 맞는 시멘트를 선택하고 생역학적인 원칙을 준수한 보철물을 설계하고 시멘트잔사를 줄이는 방법을 이용하여 합착한 후 방사선사진으로 잔사를 확인하여 완벽하게 제거해야 시멘트유지형 보철의 성공을 얻을 수 있을 것이다.

수종의 방법으로 임프란트 표면 처치후 표면의 형태 및 성분 변화 분석에 관한 연구 (The XPS and SEM Evaluation of Various Technique for Cleansing and Decontamination of The Rough Surface Titanium Implants)

  • 김선봉;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제31권4호
    • /
    • pp.749-763
    • /
    • 2001
  • Osseointegrated titanium implants have become an integral therapy for the replacement of teeth lost. For dental implant materials, titanium, hydroxyapatite and alumina oxide have been used, which of them, titanium implants are in wide use today. Titanium is known for its high corrosion resistance and biocompatability, because of the high stability of oxide layer mainly consists of $TiO_2$. With the development of peri-implantitis, the implant surface is changed in surface topography and element composition. None of the treatments for cleaning and detoxification of implant surface is efficient to remove surface contamination from contaminated titanium implants to such extent that the original surface elemental composition. In this sights, the purpose of this study was to evaluate rough surface titanium implants by means of scanning electron microscopy(SEM) and X-ray photoelectron spectroscopy(XPS) with respect to surface appearance and surface elemental composition. Moreover, it was also the aim to get the base for treatments of peri-implantitis. For the SEM and XPS study, rough surface titanium models were fabricated for control group. Six experimental groups were evaluated: 1) long-time room exposure, 2 ) air-powder abrasive cleaning for 1min, 3) burnishing in citric acid(pH1) for 1min, 4) burnishing in citric acid for 3min, 5) burnishing in tetracycline for 1min, 6) burnishing in tetracycline for 3min. All experimental treatments were followed by 1min of rinsing with distilled water. The results were as follows: 1. SEM observations of all experimental groups showed that any changes in surface topography were not detected when compared with control group. (750 X magnification) 2. XPS analysis showed that in all experimental groups, titanium and oxygen were increased and carbon was decreased, when compared with control group. 3. XPS analysis showed that the level of titanium, oxygen and carbon in the experimental group 3(citric acid treatment for 1min, followed by 1min of distilled water irrigation) reached to the level of control group. 4. XPS analysis showed that significant differences were not detected between the experimental group 1 and the other experimental groups except of experimental group 3. The Ti. level of experimental group 2, airpowder abrasive treatment for lmin followed by 1min of saline irrigation, was lower than the Ti. level of tetracycline treated groups, experimental group 5 and 6. From the result of this study, it may be concluded that the 1min of citric acid treatment followed by same time of rinsing with distilled water gave the best results from elemental points of view, and can be used safely to treat peri-implantitis.

  • PDF

임플란트 보철방식에 따른 임플란트 주위염 자각증상 및 만족도 (Subjective Symptoms of Peri-Implantitis and Satisfaction according to Prosthesis Methods)

  • 차지애;한경순
    • 치위생과학회지
    • /
    • 제17권2호
    • /
    • pp.175-182
    • /
    • 2017
  • 본 연구는 성인 375명을 대상으로 임플란트 주위염 자각증상과 만족도를 파악하여 다음과 같은 결과를 얻었다. 임플란트 주위염 자각자율은 식편압입이 40.5%, 출혈 49.1%, 통증 61.1%, 입냄새 61.9%였고, 만족도는 3.95점이었다. 보철방식에서 임플란트-자연치 연결군이 식편 압입(21.3%), 통증(35.5%), 입냄새(36.6%) 모두 가장 낮았고(p<0.001), 출혈은 임플란트 단일군(33.8%)이 가장 낮았다(p<0.05). 만족도는 임플란트-자연치 연결군(4.06점)과 골 이식을 하지 않은 군(4.03점)이 높았다(p<0.01). 요인분석 결과 임플란트 만족도는 임플란트-자연치 연결군에 비해 단일 임플란트군은 0.43배, 임플란트-임플란트 연결군은 0.44배 낮을 가능성을 나타냈다. 이상의 결과를 통해 인접한 자연치의 수명을 최대한 연장하면서 치아결손 부위의 기능을 회복할 수 있는 방법은 임플란트-자연치 연결방식이므로 다각적 검토를 통해 적극 활용할 수 있기를 기대한다.

Comparison between different cone-beam computed tomography devices in the detection of mechanically simulated peri-implant bone defects

  • Kim, Jun Ho;Abdala-Junior, Reinaldo;Munhoz, Luciana;Cortes, Arthur Rodriguez Gonzalez;Watanabe, Plauto Christopher Aranha;Costa, Claudio;Arita, Emiko Saito
    • Imaging Science in Dentistry
    • /
    • 제50권2호
    • /
    • pp.133-139
    • /
    • 2020
  • Purpose: This study compared 2 cone-beam computed tomography (CBCT) systems in the detection of mechanically simulated peri-implant buccal bone defects in dry human mandibles. Materials and Methods: Twenty-four implants were placed in 7 dry human mandibles. Peri-implant bone defects were created in the buccal plates of 16 implants using spherical burs. All mandibles were scanned using 2 CBCT systems with their commonly used acquisition protocols: i-CAT Gendex CB-500 (Imaging Sciences, Hatfield, PA, USA; field of view [FOV], 8 cm×8 cm; voxel size, 0.125 mm; 120 kVp; 5 mA; 23 s) and Orthopantomograph OP300 (Intrumentarium, Tuusula, Finland; FOV, 6 cm×8 cm; voxel size, 0.085 mm; 90 kVp; 6.3 mA; 13 s). Two oral and maxillofacial radiologists assessed the CBCT images for the presence of a defect and measured the depth of the bone defects. Diagnostic performance was compared in terms of the area under the curve (AUC), accuracy, sensitivity, specificity, and intraclass correlation coefficient. Results: High intraobserver and interobserver agreement was found (P<0.05). The OP300 showed slightly better diagnostic performance and higher detection rates than the CB-500 (AUC, 0.56±0.03), with a mean accuracy of 75.0%, sensitivity of 81.2%, and specificity of 62.5%. Higher contrast was observed with the CB-500, whereas the OP300 formed more artifacts. Conclusion: Within the limitations of this study, the present results suggest that the choice of CBCT systems with their respective commonly used acquisition protocols does not significantly affect diagnostic performance in detecting and measuring buccal peri-implant bone loss.