• 제목/요약/키워드: perfusion method

Search Result 327, Processing Time 0.032 seconds

Animal Experiment of the Pneumatic Ventrivular Assist Device (공압식 심실 보조기의 동물실험)

  • Park, Seong-Sik;Kim, Sam-hyun;Seo, Pil-won;Choi, Chang-hyu;Lee, Sang-hoon;Lee, Hyuk-soo;Hwang, Seung-ok;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.32 no.12
    • /
    • pp.1065-1077
    • /
    • 1999
  • Background : Ventricular assist devices(VADs) are being used for patients in postcvardiotomy cardiogenic shock status bridge to cardiac transplant settings and in post-myocardial infarction cardiogenic shock. The VAD which was developed at the Deparment of medical engineering in Dankook University College of Medicine was a pneumatically driven device and can maintain pulsatile flow. The goal of this study is to develop animal experimental models using the VAD and to clarify the reliability and hemodynamic property adequacy of end organ perfusion durability and severity of thrombotic-hemolytic tendency of the device. Material and Method : The pneumatic VAD was applied to 8 adult female lambs, We examined some hemodynamic parameters such as arterial blood pressure pulmonary capillary wedge pressure(pcwp) pulmonary artery pressure(PAP) left atrial pressure hour urine output cardiac index VAD flow EKG to determine the reliability of the VAD and hemodynamic compatibility of the experimental animals within 24 hours of experiment. We also observed the end organ perfusion durability of the VAD and thrombotic-hemolytic property of the VAD after 24 hours of VAD insertion. Result: We could monitor all hemodynamic parameters including pcwp PAP cardiac index EKG, adn hour urine as true clinical settings. We observed that the reliability of the VAD was excellent and the hemodynamic property of the experimental animal and end organ perfusion were adequate within 24 hours of experiment. In four lambs surviving 24 hours after insertion the reliability of the VAD and end organ perfusion were excellent and no thrombotic-hemolytic tendency was noted. However after 15 days of experiment the diaphragm of the VAD was torn and it was recommende that the durability of the VAD should be extended. Conclusion : e conclude that the pneumatic VAD developed at Dankook University Biomedical Engineering has good hemodynamic property and low thromboembolic tendency and presents adequate end organ perfusion but we noted that the durability of the device should be expanded further. It will be possible to do more reliable experiment in the future according to the animal experimental method developed in this study especially with the heart failure models.

  • PDF

Evaluation of Result of Coronary Artery Bypass Graft Surgery by Using Pre and Postoperative Myocardial SPECT (관동맥우회술 전후의 심근 SPECT를 이용한 수술 결과의 평가)

  • 이장훈;한승세
    • Journal of Chest Surgery
    • /
    • v.30 no.11
    • /
    • pp.1083-1091
    • /
    • 1997
  • This study was purposed to assess the result of coronary artery bypass graft surgery by analyzing and comparing the pre and postoperative myocardial perfusion state quantitatively by using myocardial SPECT. Twenty patients who received coronary artery bypass graft surgery since 1993 underwent both preoperative and postoperative myocardial SPECT and the result were analyzed. The mean age was 56.4$\pm$9.0 years, and the patients were composed of thirteen males and seven females. For quantitative analysis, we used polar maps of SPECT generated by Cedars-Sin i Medical Center program and we calculated perfusion scores, ischemic myocardial area ratios and reperfusion scores from polar maps. Preoperative mean stressfrest perfusion score was 7.3$\pm$ 1.117.7$\pm$ 1.0 and postoperative score was 8.1 $\pm$ 1 118.3$\pm$ 1.1. Preoperative mean stress ischemic myocardial area ratio was 0.32$\pm$0.2 and postoperative ratio was 0.15 $\pm$0.1. Postoperative mean perfusion score was significantly increased but, on the other hand, mean ischemic myocardial area ratio was significantly decreased as compared with preoperative values(p<0.01). Preoperative mean perfusion score of patients with postoperative roper(usion score more than 1.5 was significantly higher(p<0.01) than that of patients with postoperative reperfusion score less than 1.5. Preoperative perfusion scores of coronary artery territories that had fixed perfusion defect at myocardial SPECT were significantly low(4.3 $\pm$0.514.6$\pm$0.6, stresslrest), nevertheless it proved quantitatively that there was improvement in myocardial perfusion after surgery by showing improved perfusion scores postoperatively. In conclusion, myocardial SPECT is useful method for quantitative analysis of the myocardial perfusion state after coronary artery bypass grafting surgery.

  • PDF

Clinical Result of Aortic Arch Replacement using Antegrade Brain Perfusion Via Right Axillary Artery (우액와동맥을 통한 순행성 뇌관류법을 이용한 대동맥궁 치환의 임상성적)

  • Kim, Dong-Jin;Na, Yong-Jun;Jeong, Dong-Seop;Kim, Kyung-Hwan
    • Journal of Chest Surgery
    • /
    • v.40 no.1 s.270
    • /
    • pp.25-31
    • /
    • 2007
  • Background: Cerebral protection is one of the most important procedures during aortic arch surgery. We can minimize neurological complications through short period of total circulatory arrest and resuming of brain perfusion. We evaluated 11 patients who underwent arch replacement using antegrade brain perfusion via right axillary artery. Material and Method: Between July 2004 and July 2006, 11 patients (male 9, female 2) underwent aortic arch replacement with antegrade brain perfusion via right axillary artery. Preoperative diagnosis was listed; 5 type A aortic dissections (5/11, 45.5%), 5 aortic aneurysms (5/11, 45,5%) and 1 type A IMH (intramural hematoma, 1/11, 9%). The mean age at the time of operation was $60.3{\pm}12.8$ years. For antegrade brain perfusion, we performed right axillary artery cannulation in all patients. Retrograde brain perfusion was used briefly during total circulatory arrest. Result: The mean total circulatory arrest time was $31.1{\pm}16.9$ minutes and the mean retrograde brain perfusion time was $21{\pm}17.8$ minutes. Mean antegrade brain perfusion time was $77.9{\pm}17.5\;(43{\sim}101)$ minutes. We had neither operative mortality nor permanent neurological complications. Conclusion: By means of antegrade brain perfusion via right axillary artery, that could lead to decrease circulatory arrest time and minimize damages to severely atheromatous arch vessels, we can expect to reduce neurological complications after aortic arch replacement. Further investigation with iarge patient populations will be required.

Effects of Cephalic Glucopenia on Insulin and Glucagon Secretion in Central Nervous System-Intact Pancreas Perfused Rats (중추신경이 온전한 쥐의 Cephalic Glucopenia가 인슐린과 글루카곤 분비에 미치는 영향)

  • Hyun Ju Choi
    • Biomedical Science Letters
    • /
    • v.6 no.4
    • /
    • pp.229-235
    • /
    • 2000
  • In situ brain-pancreas perfusion was performed on male adult Sprague-Dawley rats, of which the central nervous systems (CNS) were intact during the perfusion procedure. The modified Krebs-Ringer buffer with 100 mg/dL of glucose and 20 mM of arginine was perfused for 30 min. In the experimental groups, a cephalic glucopenia was induced at 0 min (GLP1 group) or at 16 min (GLP2 group). The glucopenia was not induced in the control (CONT group). Insulin and glucagon concentrations in the effluent samples from the pancreas were measured using a RIA method. In all three groups, the first and second phases in the dynamics of the insulin and glucagon secretion were observed, which was a typical biphasic secretory pattern. The amount of insulin secretion tended to decrease in the GLP1 and GLP2 groups, but there was no statistically significant difference among the groups. However, the amount of glucagon secretion during 0~15 min of the perfusion period in the GLP1 group was greater as compared to the CONT group (p<0.05). The amount of glucagon secretion during 16~30 min of the perfusion period in the GLP2 group tended to be greater as compared to the CONT group, however there was no statistical significance. These data indicate that the cephalic glucopenia stimulates the direct secretion of glucagon from the pancreas during the early period of perfusion in the CNS-intact pancreatic perfused rats.

  • PDF

A Study on Cerebral Blood Flow Enhancement Device Using Blood Oxygen Level Sensor (Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치에 관한 연구)

  • Lim, Jung-Hyun;Joh, In-Hee;Kim, Young-kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.188-192
    • /
    • 2018
  • Surgery to increase cerebral blood flow is one of the treatment methods of cerebral infarction. However, invasive methods, such as surgery, may result in postoperative complications or side effects. In order to supplement this invasive method, non-invasive devices have been introduced that use human blood pressure to pressurize the extremities to increase cerebral blood flow. However, the problem of poor speed and accuracy was raised. In this paper, the perfusion index of each arm was measured by applying pressure to both arms using Blood Oxygen Level Sensor to improve the accuracy of measurement and measurement time. The pressure applied to the arm by 75% of the moment when it falls to the leg and the pressure calculated by using the pressure value obtained from the arm. Like the existing blood pressure measuring cerebral blood flow increasing device, the blood flow can be increased by more than 20% and the measurement time can be shortened, so that it can be selectively used for the patient with cerebral infarction.

  • PDF

$^{99m}TC-MAA$ Pulmonary Perfusion Scan in the Canine Single Luhg Transplant (개에서 시행한 한쪽 이식 폐의 $^{99m}TC-MAA$ 관류스캔)

  • Zeon, S.K.;Ryu, J.G.;Park, C.K.;Yoo, Y.S.;Jung, D.S.;Lee, J.K.
    • The Korean Journal of Nuclear Medicine
    • /
    • v.31 no.3
    • /
    • pp.365-371
    • /
    • 1997
  • The aim of this study is to evaluate the efficiency of the pulmonary perfusion scan(Pp scan) in the experimental animal single lung transplantation. Eight left lung transplanted mongrel dogs were included in this study. The serial Pp scan with 111MBq $^{99m}TC-MAA$ were done at the periods of immediate postoperative period, POD 3 days, and POD 10-14 days and finally autopsy was done in each cases. The transplanted lung perfusion was analysed as a percentage radioactivity of trans planted/native lung(T/N) ratio. The Pp scan of a donor mongrel dog was used as a reference(left/right lung (T/N) ratio 85.2%). The average T/N ratio of all cases on immediate postoperative state(reperfusion injury) : 19.2%, three acute rejections. 12.6%, three bronchial dehiscences 6.1% and two pulmonary thromboses : 2.0%. Two cases showed moderate improvement of reperfusion injury as increasing the T/N ratio in POD 3 days Pp scan. The T/N ratio showed sequentially decreased in six cases. As a conclusion, the Pp scan could be a non-invasive method in the evaluation of the experimental one-lung transplanted mongrel dog.

  • PDF

Cerebral blood flow enhancement device using Blood Oxygen Level Sensor (Blood Oxygen Level Sensor를 이용한 대뇌혈류증가 장치)

  • Lim, Jung-hyun;Joh, In-Hee;Kim, Young-kil
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1083-1089
    • /
    • 2018
  • Surgery to increase cerebral blood flow is one of the treatment methods of cerebral infarction. In order to supplement this invasive method, non-invasive devices have been introduced that use human blood pressure to pressurize the extremities to increase cerebral blood flow. However, the problem of poor speed and accuracy was raised. In this paper, the perfusion index of each arm is measured by applying pressure to both arms using Blood Oxygen Level Sensor to improve the accuracy of measurement and measurement time. The pressure applied to the arm is calculated by using the pressure value obtained from the arm. Like the existing blood pressure measuring cerebral blood flow increasing device, the blood flow can be increased by more than 20% and the measurement time can be shortened, so that it can be selectively used for the patient with cerebral infarction.

Comparison of the Diagnostic Accuracies of 1.5T and 3T Stress Myocardial Perfusion Cardiovascular Magnetic Resonance for Detecting Significant Coronary Artery Disease

  • Min, Jee Young;Ko, Sung Min;Song, In Young;Yi, Jung Geun;Hwang, Hweung Kon;Shin, Je Kyoun
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1007-1020
    • /
    • 2018
  • Objective: To compare the diagnostic performance of cardiovascular magnetic resonance (CMR) myocardial perfusion at 1.5- and 3-tesla (T) for detecting significant coronary artery disease (CAD), with invasive coronary angiography (ICA) as the reference method. Materials and Methods: We prospectively enrolled 281 patients (age $62.4{\pm}8.3$ years, 193 men) with suspected or known CAD who had undergone 1.5T or 3T CMR and ICA. Two independent radiologists interpreted perfusion defects. With ICA as the reference standard, the diagnostic performance of 1.5T and 3T CMR for identifying significant CAD (${\geq}50%$ diameter reduction of the left main and ${\geq}70%$ diameter reduction of other epicardial arteries) was determined. Results: No differences were observed in baseline characteristics or prevalence of CAD and old myocardial infarction (MI) using 1.5T (n = 135) or 3T (n = 146) systems. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve (AUC) for detecting significant CAD were similar between the 1.5T (84%, 64%, 74%, 76%, and 0.75 per patient and 68%, 83%, 66%, 84%, and 0.76 per vessel) and 3T (80%, 71%, 71%, 80%, and 0.76 per patient and 75%, 86%, 64%, 91%, and 0.81 per vessel) systems. In patients with multi-vessel CAD without old MI, the sensitivity, specificity, and AUC with 3T were greater than those with 1.5T on a per-vessel basis (71% vs. 36%, 92% vs. 69%, and 0.82 vs. 0.53, respectively). Conclusion: 3T CMR has similar diagnostic performance to 1.5T CMR in detecting significant CAD, except for higher diagnostic performance in patients with multi-vessel CAD without old MI.

Magnetic resonance imaging texture analysis for the evaluation of viable ovarian tissue in patients with ovarian endometriosis: a retrospective case-control study

  • Lee, Dayong;Lee, Hyun Jung
    • Journal of Yeungnam Medical Science
    • /
    • v.39 no.1
    • /
    • pp.24-30
    • /
    • 2022
  • Background: Texture analysis has been used as a method for quantifying image properties based on textural features. The aim of the present study was to evaluate the usefulness of magnetic resonance imaging (MRI) texture analysis for the evaluation of viable ovarian tissue on the perfusion map of ovarian endometriosis. Methods: To generate a normalized perfusion map, subtracted T1-weighted imaging (T1WI), T1WI and contrast-enhanced T1W1 with sequences were performed using the same parameters in 25 patients with surgically confirmed ovarian endometriosis. Integrated density is defined as the sum of the values of the pixels in the image or selection. We investigated the parameters for texture analysis in ovarian endometriosis, including angular second moment (ASM), contrast, correlation, inverse difference moment (IDM), and entropy, which is equivalent to the product of area and mean gray value. Results: The perfusion ratio and integrated density of normal ovary were 0.52±0.05 and 238.72±136.21, respectively. Compared with the normal ovary, the affected ovary showed significant differences in total size (p<0.001), fractional area ratio (p<0.001), and perfusion ratio (p=0.010) but no significant differences in perfused tissue area (p=0.158) and integrated density (p=0.112). In comparison of parameters for texture analysis between the ovary with endometriosis and the contralateral normal ovary, ASM (p=0.004), contrast (p=0.002), IDM (p<0.001), and entropy (p=0.028) showed significant differences. A linear regression analysis revealed that fractional area had significant correlations with ASM (r2=0.211), IDM (r2=0.332), and entropy (r2=0.289). Conclusion: MRI texture analysis could be useful for the evaluation of viable ovarian tissues in patients with ovarian endometriosis.

Evaluation of Perfusion and Image Quality Changes by Reconstruction Methods in 13N-Ammonia Myocardial Perfusion PET/CT (13N-암모니아 심근관류 PET/CT 검사 시 영상 재구성 방법에 따른 관류량 변화와 영상 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.69-75
    • /
    • 2014
  • Purpose: The aim of this study was to evaluate changes of quantitative and semi-quantitative myocardial perfusion indices and image quality by image reconstruction methods in $^{13}N$-ammonia ($^{13}N-NH_3$) myocardial perfusion PET/CT. Materials and Methods: Data of 14 (8 men, 6 women) patients underwent rest and adenosine stress $^{13}N-NH_3$ PET/CT (Biograph TruePoint 40 with TrueV, Siemens) were collected. Listmode scans were acquired for 10 minutes by injecting 370MBq of $^{13}N-NH_3$. Dynamic and static reconstruction was performed by use of FBP, iterative2D (2D), iterative3D (3D) and iterative TrueX (TrueX) algorithm. Coronary flow reserve (CFR) of dynamic reconstruction data, extent(%) and total perfusion deficit (TPD) (%) measured in sum of 4-10 minutes scan were evaluated by comparing with 2D method which was recommended by vendor. The image quality of each reconstructed data was compared and evaluated by five nuclear medicine physicians through a blind test. Results: CFR were lower in TrueX 18.68% (P=0.0002), FBP 4.35% (P=0.1243) and higher in 3D 7.91% (P<0.0001). As semi-quantitative values, extent and TPD of stress were higher in 3D 3.07%p (P=0.001), 2.36%p (P=0.0002), FBP 1.93%p (P=0.4275), 1.57%p (P=0.4595), TrueX 5.43%p (P=0.0003), 3.93%p (P<0.0001). Extent and TPD of rest were lower in FBP 0.86%p (P=0.1953), 0.57%p (P=0.2053) and higher in 3D 3.21%p (P=0.0006), 2.57%p (P=0.0001) and TrueX 5.36%p (P<0.0001), 4.36%p (P<0.0001). Based on the results of the blind test for image resolution and noise from the snapshot, 3D obtained the highest score, followed by 2D, TrueX and FBP. Conclusion: We found that quantitative and semi-quantitative myocardial perfusion values could be under- or over-estimated according to the reconstruction algorithm in $^{13}N-NH_3$ PET/CT. Therefore, proper dynamic and static reconstruction method should be established to provide accurate myocardial perfusion value.

  • PDF