• Title/Summary/Keyword: perfusion SPECT

Search Result 249, Processing Time 0.032 seconds

Spect Assessment of Regional Cerebral Perfusion Abnormality in Head Injury (두부외상 환자에서 HMPAO-SPECT를 이용한 국소 뇌혈류 변화의 평가)

  • Lee, Kyung-Han;Kim, Chul-Hee;Chang, Ha-Sung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.235-243
    • /
    • 1992
  • Patterns of abnormality in regional cerebral perfusion and its relation to clinical severity was evaluated with 32 head injury patients using $^{99m}Tc-HMPAO$ single photon emission tomography (SPECT). The findings were compared with computed tomography (CT) done within 48 hours of each SPECT study. The initial SPECT study was done within 7 days of injury in 16 cases, between 1 week and 2 months in 12, and after over 2 months in 4. Nineteen of the patients underwent followup SPECT and CT after a mean interval of 1 to 2 months. The initial SPECT showed abnormalities in 96% (31/32) of the patients while CT showed abnormal findings in only 81% (26/32). There were a total of 54 supratentorial SPECT lesions in all. Ninity percent (49/54) of these were of regional hypoperfusion, while 5 lesions showed focal hyperperfusion. The lesions were most often localized in the frontal and temporal lobes. Fifty five percent (30/54) were areas not detected as a lesion on CT. Cerebellar diaschisis was observed in 50% (16/32) of the patients. The degree of perfusion abnormality was quantified by the product of differential activity and a size factor. Correlation between the degree of perfusion abnormality and the clinical severity (Glasgow coma scale) failed to show statistical significance (p=0.053). The amount of change in the degree of perfusion abnormality on follow up SPECT was compared to the amount of change in clinical severity. Perfusion abnormality showed a tendancy to improve in most patients, and the degree of improvement showed significant correlation with the amount of clinical improvement (p < 0.01).

  • PDF

Diagnosis of Coronary Artery Disease Using Myocardial Perfusion SPECT (심근 SPECT를 이용한 관상동맥질환의 진단)

  • Won, Kyoung-Sook;Kim, Hae-Won
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.196-202
    • /
    • 2009
  • Myocardial perfusion scintigraphy is currently by far the most commonly performed cardiac nuclear study, constituting approximately one third of all nuclear medicine procedure. It plays an important role in the diagnosis, prognosis, risk assessment and management of heart disease. Aim of this review is to describe recent evolution of myocardial perfusion imaging on the focus of diagnosis of coronary artery disease. In addition, current status of other imaging modalities will be reviewed.

The Correlation Analysis of Ejection Fraction: Comparison of $^{201}Tl$ gated Myocardial Perfusion SPECT and Echocardiography ($^{201}Tl$ 게이트 심근관류 SPECT 및 심초음파의 좌심실 구혈률 상관관계 비교)

  • Yoon, Soon Sang;Ryu, Jae Kwang;Cha, Min Kyung;Lee, Jong Hun;Kim, Sung Hwan
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.49-56
    • /
    • 2012
  • Purpose : Gated myocardial perfusion SPECT provides not only myocardial perfusion status, but various functional parameters of left ventricle (LV). The purpose of this study was to analyze ejection fraction (EF) for correlation and difference between $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography depending on extent of perfusion defect, gender and LV volumes. Materials and Methods : From April 2011 to May 2012, we analyzed 291 patients (male:female =165:126; mean: $64.6{\pm}10.8$ years) who were examined both $^{201}Tl$ gated myocardial perfusion SPECT and echocardiography at less than 7 days apart in our hospital. 101 patients showed perfusion defect and the rest of the people without any defect. We applied automatic analysis (Quantitative gated SPECT, QGS), and calculated EF, End-diastolic volume (EDV) and End-systolic volume (ESV) from Stress (G-Stress) and Rest (G-Rest) studies. And we analyzed the correlation and difference for EF between $^{201}Tl$ gated SPECT and echocardiography. Results : The correlation of LVEF among G-Stress, G-Rest and echocardiography was quite a good (G-Stress vs. G-Rest: r=0.909, G-Stress vs. echocardiography: r=0.833, G-Rest vs. echocardiography: r=0.825). And there were significant differences in EDV, ESV and EF in total patients (p<0.01). The normal group showed significant difference in EF (p<0.01) and the group with perfusion defect also demonstrated significant difference (a group with reversible defect: p<0.01, fixed defect: p<0.01) depending on extent of perfusion defect. We analyzed difference in normal group by gender. In normal group, there was no significant difference (p>0.05) in EF from men. However, there was a significant difference (p<0.01) from women. When we classified two groups by average size of EDV in Korean women, there was no significant difference in a group of above average size of EDV (p>0.05). Conclusion : When compared among Stress and Rest of $^{201}Tl$ gated SPECT and echocardiography, we confirmed that there was a good correlation for LVEF. But there were significant differences among three studies. And extent of perfusion defect, gender and LV volumes are independent determinants of the accuracy of LVEF. So, it is hard to compare and interchange quantitative indices among modalities. We should take additional researches to prove results of our study.

  • PDF

Brain SPECT Using $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD in Subacute Cerebral Infarction: Case Report (아급성 뇌경색 환자에서 $^{99m}Tc$-HMPAO 및 $^{99m}Tc$-ECD 뇌 SPECT: 증례보고)

  • Ahn, Byeong-Cheol;Lee, Dong-Soo;Yoon, Byung-Woo;So, Young;Jung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.570-575
    • /
    • 1996
  • For brain perfusion SPECT imaging, $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD are commonly used. Although these two tracers usually show similar distribution, it is well known that discrepant finding might be noted between $^{99m}Tc$-HMPAO and $^{99m}Tc$-ECD imaging in some conditions. Luxury perfusion(perfusion/metabolism mismatch) is one of the examples and could be observed in subacute cerebral infarction. We report a case of subacute cerebral infarction that revealed luxury perfusion. Increased perfusion was found in $^{99m}Tc$-HMPAO SPECT and perfusion defect was found in $^{99m}Tc$-ECD SPECT. We found large area of mismatch with a consecutive acquisition-subtraction method. Crossed cerebellar diaschisis was observed in both SPECT images.

  • PDF

Evaluation of Result of CABG by Comparison of Pre-and Post-operative Myocardial SPECT (관동맥우회로술 전후의 디피리다몰 부하/휴식 심근 SPECT를 이용한 수술 결과의 평가)

  • Lee, Dong-Soo;Lee, Won-Woo;Kang, Keon-Wook;Hyun, In-Young;Kim, Ki-Bong;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.86-94
    • /
    • 1996
  • Coronary angiography should be performed to verify the patency of bypass graft if coronary artery disease is said to be surgically corrected. Rest/stress myocardial SPECT could be used as a noninvasive alternative to prove patency of bypass graft and functional significance of graft patency by showing improvement of rest perfusion and perfusion reserve after operation. We evaluated the outcome of coronary artery bypass graft surgery by comparing rest/dipyridamole-stress myocardial SPECT before and after operation. Myocardial SPECT were performed $19{\pm}23$ days before and $108{\pm}19$ days after operation in 44 patients(M:F=25:19). Segmental perfusion were scored with 0(normal) to 3(defect) independently for each image set of rest and stress. Perfusion scores were compared between pre and postoperative images. Rest/stress images of pre and post-operative SPECT were compared in paired sets. Postoperative change of perfusion was determined as no change, improvement or aggravation for each artery territory. Postoperative outcome of patients were analyzed. Overall, 74%(158 segments) of 215 segments which had perfusion decrease before operation showed improvement. Among 60 artery territories, 37 territories(62%) improved. Among 42 patients with perfusion decrease in preoperative SPECT, 21 patients(47%) improved after operation. Severe persistent defects improved in 43%(6/14). We concluded that bypass surgery improved myocardial perfusion in dipyridamole stress induced or persistent decrease and that rest/stress myocardial SPECT could be used as a guide for which artery should be operated.

  • PDF

Usability of Multiple Confocal SPECT SYSTEM in the Myocardial Perfusion SPECT Using $^{99m}Tc$ ($^{99m}Tc$을 이용한 심근 관류 SPECT에서 Multiple Confocal SPECT System의 유용성)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.65-71
    • /
    • 2011
  • Purpose: The recently adopted multiple confocal SPECT SYSTEM (hereinafter called IQ SPECT$^{TM}$) has a high difference from the conventional myocardial perfusion SPECT in the collimator form, image capture method, and image reconstruction method. This study was conducted to compare this novice equipment with the conventional one to design a protocol meeting the IQ SPECT, and also determine the characteristics and usefulness of IQ SPECT. Materials and Methods: 1. For the objects of LEHR (Low energy high resolution) collimator and Multiple confocal collimator, $^{99m}Tc$ 37MBq was put in the acrylic dish then each sensitivity ($cpm/{\mu}Ci$) was measured at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. 2. Based on the sensitivity measure results, IQ SPECT Protocol was designed according to the conventional general myocardial SPECT, then respectively 278 kBq/mL, 7.4 kBq/mL, and 48 kBq/mL of $^{99m}Tc$ were injected into the myocardial and soft tissues and liver site by using the anthropomorphic torso phantom then the myocardial perfusion SPECT was run. 3. For the comparison of FWHMs (Full Width at Half Maximum) resulted from the image reconstruction of LEHR collimator, the FWHMs (mm) were measured with only algorithms changed, in the case of the FBP (Filtered Back projection) method- a reconstruction method of conventional myocardial perfusion SPECT, and the 3D OSEM (Ordered subsets expectation maximization) method of IQ SPECT, by using $^{99m}Tc$ Line source. Results: 1. The values of IQ SPECT collimator sensitivity ($cpm/{\mu}Ci$) were 302, 382, 655, 816, 1178, and those of LEHR collimator were measured as 204, 204, 202, 201, 198, both at the distance of 5 cm, 10 cm, 20 cm, 30 cm, and 40 cm respectively. It was found the difference of sensitivity increases up to 4 times at the distance of 30 cm in the cases of IQ SPECT and LEHR. 2. The myocardial perfusion SPECT Protocol was designed according to the geometric characteristics of IQ SPECT based on the sensitivity results, then the phantom test for the aforesaid protocol was conducted. As a result, it was found the examination time can be reduced 1/4 compared to the past. 3. In the comparison of FWHMs according to the reconstructed algorithm in the FBP method and 3D OSEM method followed after the SEPCT test using a LEHR collimator, the result was obtained that FWHM rose around twice in the 3D OSEM method. Conclusion : The IQ SPECT uses the Multiple confocal collimator for the myocardial perfusion SPECT to enhance the sensitivity and also reduces examination time and contributes to improvement of visual screen quality through the myocardial-specific geometric image capture method and image reconstruction method. Due to such benefits, it is expected patients will receive more comfortable and more accurate examinations and it is considered a further study is required using additional clinical materials.

  • PDF

Comparison of Emergency Tc-99m Sestamibi Myocardial Perfusion SPECT and ECG in the Diagnosis of Acute Myocardial Infarction (급성심근경색증 환자에서 응급으로 시행한 Tc-99m Sestamibi 심근관류 SPECT와 심전도의 비교)

  • Cho, Ihn-Ho;Lee, Hyoung-Woo;Park, Jong-Sun;Won, Kyu-Chang;Do, Jun-Young;Sin, Dong-Gu;Yoon, Kyung-Woo;Kim, Young-Jo;Shim, Bong-Sup;Lee, Hyun-Woo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.104-111
    • /
    • 1996
  • We did Tc-99m sestamibi myocardial perfusion SPECT in 36 patients with acute myocardial infarction when they arrived at the emergency room. And we compared myocardial perfusion images with ECG findings. Then we obtained the follows. The myocardial infarction by the obstruction of left coronary descending artery and right coronary artery showed a good concordance in the diagnosis and infarction site between myocardial perfusion images and ECG findings. The 7 patients with myocardial infarction by a left circumflex coronary artery showed a perfusion defect in the lateral wall in myocardial perfusion SPECT images. But 4 patients of them showed ST segment elevation, 2 patients showed ST depression and 1 patient showed normal ECG findings. The diagnostic sensitivity of Tc-99m sestamibi myocardial perfusion SPECT was 100% by a qualified analysis. The perfusion defect site in the myocardial perfusion SPECT were corresponded with the infarct related coronary artery in 31 patients which was diagnosed by coronary angiograpy. The size of perfusion defect in the po1ar map was $31{\pm}18%(M{\pm}SD)$, in the myocardial infarction with left anterior descending coronary arery obstruction, $31{\pm}13% (M{\pm}SD)$ in the myocardial infarction with right coronary artery obstruction and $25{\pm}5.9%(M{\pm}SD)$ in the myocardial infarction with left circumflex coronary artery obstruction. We concluded that emergency myocardial perfusion SPECT images are useful in the diagnose of myocardial infarction and it's very useful when we are difficult to diagnose with ECG like as lateral wall infarction or left bundle branch block.

  • PDF

Accuracy of Ventricular Volume and Ejection Fraction Measured by Gated Tl-201 Perfusion Single Photon Emission Tomography (심전도 게이트 심근관류 Tl-201 SPECT로 측정된 좌심실 기능 및 좌심실 용적의 정확성)

  • Pai, Moon-Sun;Moon, Dae-Hyuk
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.94-99
    • /
    • 2005
  • Electrocardiogram-gated single photon omission computed tomography (SPECT) provides valuable information in the assessment of both myocardial perfusion and ventricular function. Tl-201 is a suboptimal isotope for gating. Tl-201 images are more blurred compared with Tc-99m tracers due to the increased amount of scattered photons and use of a smooth filter. The average myocardial count densities are approximately one-half those of conventional technetium tracers. However, Tl-201 is still widely used because of its well-established utility for assessing myocardial perfusion, viability and risk stratification. Gated SPECT with Tl-201 enables us to assess both post-stress and rest left ventricular volume and function. Previous studies with gated Tl-201 SPECT measurements of ejection fraction (EF), end-diastolic volume (EDV), end-systolic volume (ESV) have shown high correlation with first-pass radionuclide angiography, gated blood pool scan, Tc-99m-MIBI gated SPECT, contrast ventriculography, echocardiography, and 3-dimensional magnetic resonance imaging. However, problems related to these studies include few agreement data of EDV and ESV, use of a reference method that is likely to have the same systemic errors (gated Tc-99m-MIBI SPECT), and other technical factors related to the count density of gated SPECT. With optimization of gated imaging protocols and more validation studies, gated Tl-201 SPECT would be an accurate method to provide perfusion and function information in patients with coronary artery disease.

The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT (SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가)

  • Choi, Jong-Sook;Jung, Woo-Young;Shin, Sang-Ki;Cho, Shee-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.12 no.3
    • /
    • pp.214-221
    • /
    • 2008
  • Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion's anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested $^{131}I$-MIBG, Bone, $^{111}In$-Octreotide, Meckel's diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai' QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section's perfusion states by percentage. We compared the each section's perfusion-states differences between CT AC and Non AC by average${\pm}$standard deviation. Results: 1. The evaluation of fusion images : In high energy $^{131}I$ cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions' uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel's diverticulum case or to find lesions around bowels or organs with $^{111}In$ cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image ($68.58{\pm}7.55$) and CT corrected perfusion image ($76.84{\pm}6.52$) was the largest by $8.26{\pm}4.95$ (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

  • PDF

Assessment of Ventricular Function Using Gated Blood Pool Scan and Gated Blood Pool SPECT (게이트심장혈액풀 스캔과 게이트심장혈액풀 SPECT를 이용한 심실기능의 평가)

  • Park, Seok-Gun
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.2
    • /
    • pp.100-106
    • /
    • 2005
  • Non-invasive evaluation of cardiac function by nuclear medicine technologies are one of the major contribution of nuclear medicine. Gated cardiac blood pool scan was once a novel and robust technique which enabled evaluation of ventricular function. Concept of EKG gating was one of the major breakthrough in nuclear cardiology. According to the evolution of echocardiographic techniques, and as the evaluation of myocardial perfusion by perfusion SPECT became feasible, number of gated blood pool study dong in nuclear medicine laboratory is declining. And recently, evaluation of ventricular function with gated perfusion SPECT further decreased the use of gated blood pool scan. In this article, assessment of ventricular function using gated blood pool scan is discussed including some insight about the role of gated blood pool SPECT.