• Title/Summary/Keyword: perfusion CT

Search Result 90, Processing Time 0.042 seconds

Assessment of Prognosis and Risk Stratification in Coronary Artery Disease (관상동맥질환의 예후 및 위험도 평가)

  • Lim, Seok-Tae
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.3
    • /
    • pp.222-228
    • /
    • 2009
  • Risk stratification and assessment of prognosis in patients with known or suspected CAD is of crucial important for the practice of contemporary medicine. Noninvasive testing such as myocardial perfusion scintigraphy, coronary artery calcium scoring or CT coronary angiography is increasingly being used to determine the need for aggressive medical therapy and to select patients for catheterization. The integrated anatomic and functional information may provide more additional information for the cardiologist or other clinician by the improved risk stratification and diagnostic accuracy of integrated techniques. The development of SPECT/CT or PET/CT hybrid systems is therefore of important value for the nuclear cardiology.

Comparison of Clinical Usefulness between N-13 Ammonia PET/CT and Tc-99m Sestamibi SPET in Coronary Artery Disease (관상동맥질환에서 N-13 암모니아 PET/CT와 Tc-99m 세스타미비 SPECT의 임상 유용성 비교)

  • Kong, Eun-Jung;Cho, Ihn-Ho;Chun, Kyung-Ah;Won, Kyu-Chang;Lee, Hyung-Woo;Park, Jeong-Sun;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seop
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.5
    • /
    • pp.354-361
    • /
    • 2008
  • Purpose: N-13 ammonia uptake and retention in the myocardium is related to perfusion and metabolism. There are several potential advantages of N-13 ammonia positron emission tomography (PET) to detect myocardial ischemia, such as higher spatial resolution, greater counting efficiencies, and robust attenuation correction. But there are few reports comparing Tc-99m myocardial perfusion single photon emission tomography (MPS) and N-13 ammonia PET. We thus compared adenosine stress N-13 ammonia PET/CT and Tc-99m sestamibi MPS in patients with suspected coronary artery stenosis. Materials and Methods: Seventeen patients (male 13 : $63{\pm}11$ years old) underwent adenosine stress N-13 ammonia PET/CT (Discovery ST, GE), Tc-99m sestamibi MPS (dual head gamma camera, Hawkeye, GE) and coronary angiography within 1 week. N-13 ammonia PET/CT and Tc-99m sestamibi MPS images were assessed with a 20-segment model by visual interpretation and quantitative analysis using automatic quantitative software (Myovation, GE). Results: Both sensitivities and specificities of detecting an individual coronary artery stenosis were higher for N-13 ammonia PET/CT than Tc-99m sestamibi MPS (PET/CT: 91%/89% vs MPS: 65%/82%). N-13 ammonia PET/CT showed reversibility in 52% of segments that were considered non-reversibile by Tc-99m sestamibi MPS. In the 110 myocardial segments supplied by the stenotic coronary artery, N-13 ammonia PET/CT showed higher count densities than Tc-99m MPS on rest study (p < 0.01), and the difference of count density between the stress and the rest studies was also larger on N-13 ammonia PET/CT. Conclusion: Adenosine stress N-13 ammonia PET/CT had higher diagnostic sensitivity and specificity, more reversibility of perfusion defects and greater stress/rest uptake differences than Tc-99m sestamibi MPS. Accordingly, N-13 ammonia PET/CT might offer better assessment of myocardial ischemia and viability.

Pre- and Post-Angioplasty Perfusion CT with Acetazolamide Challenge in Patients with Unilateral Cerebrovascular Stenotic Disease

  • You, Seung-Hoon;Jo, Sung-Min;Kim, Young-June;Lee, Jong-Hyeog;Jo, Kwang-Deog;Park, Woong-Sub
    • Journal of Korean Neurosurgical Society
    • /
    • v.54 no.4
    • /
    • pp.280-288
    • /
    • 2013
  • Objective : Perfusion computed tomography (PCT) has the ability to measure quantitative value and produce maps of mean transit time (MTT), cerebral blood flow (CBF), and cerebral blood volume (CBV). We assessed cerebral hemodynamics by using these parameters and acetazolamide (ACZ) challenge for pre- and post-procedural evaluation in patients with unilateral cerebrovascular stenotic disease. Methods : Thirty patients underwent pre-procedural PCT with ACZ challenge, and 24 patients (80%) was conducted follow up PCT after angioplasty with same protocol. The mean MTT, CBF, and CBV were measured and compared in both middle cerebral arterial (MCA) territories before and after ACZ challenge. Hemispheric ratio and percent change after ACZ challenge were calculated before and after angioplasty. Results : The mean stenosis rate was 76.6%. Significant increases in MTT (32.6%, p=0.000) and significant decreases in CBF (-14.2%, p=0.000) were found in stenotic side MCA territories. After ACZ challenge, there were significant changes in MTT (37.4%, p=0.000), CBF (-13.1%, p=0.000), and CBV (-10.5%, p=0.001) in pre-procedural perfusion study. However, no significant increases were found in MTT, or decreases in CBF and CBV in post-procedural study. There were no significant changes after ACZ challenge also. In addition, the degrees of these changes (before and after ACZ challenge) were highly correlated with the stenotic degrees in pre-procedural perfusion study. Conclusion : PCT with ACZ challenge appears to be a useful tool to assess the cerebral perfusion status especially in patients with unilateral symptomatic stenotic disease.

Clinical Utility of $^{99m}Tc-HMPAO$ Brain SPECT Findings in Chronic Head Injury (만성 두부외상 환자에서 $^{99m}Tc-HMPAO$ Brain SPECT의 임상적 유용성)

  • Chung, Jin-Ill;Chung, Tae-Sub;Suh, Jung-Ho;Kim, Dong-Ik;Lee, Jong-Doo;Park, Chang-Yoon;Kim, Young-Soo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.26-32
    • /
    • 1992
  • Minimal deterioration of cerebral perfusion or microanatomical changes were undetectable on conventional Brain CT or MRI. So evaluation of focal functional changes of the brain parenchyme is essential in chronic head injury patients, who did not show focal anatomical changes on these radiological studies. However, the patients who had longstanding neurologic sequelae following head injury, there had been no available imaging modalities for evaluating these patients precisely. Therefore we tried to detect the focal functional changes on the brain parenchyme using $^{99m}Tc-HMPAO$ Brain SPECT on the patients of chronic head injuries. Twenty three patients who had suffered from headache, memory dysfunction, personality change and insomnia lasting more than six months fellowing head injury were included in our cases, which showed no anatomical abnormalities on Brain CT or MRI. At first they underwent psychological test whether the symptoms were organic or not. Also we were able to evaluate the cerebral perfusion changes with $^{99m}Tc-HMPAO$ Brain SPECT in 22 patients among the 23, which five patients were focal and 17 patients were nonfocally diffuse perfusion changes. Thus we can predict the perfusion changes such as local vascular deterioration or functional defects using $^{99m}Tc-HMPAO$ Brain SPECT in the patients who had suffered from post-traumatic sequelae, which changes were undetectable on Brain CT or MRI.

  • PDF

Pulmonary Thromboendanterectomy of Chronic Pulmonary Thromboembol ism -A case Report- (만성 폐색전증의 색전제거술 -치험 1례 보고-)

  • 신윤철;지현근
    • Journal of Chest Surgery
    • /
    • v.29 no.5
    • /
    • pp.569-572
    • /
    • 1996
  • A sixty nine-year-old mate patient was admitted with a chief complaint of exertional dyspnea. Lung perfusion scan revealed total perfusion defect of the of left lung and CT anglography showed the ab- rupt cutoff left pulmonary artery. He denied of trauma history, previous lower leg symptom and sign, or any embolic history. With the impression of chronic pulmonary thromboembolism of unknown etiology, operation was done under the cardiopulmonary bypass through a median sternotomy. After main pulmonary artery clamping and pulmonary arteriotomy, thromboembolectomy was done. Postoperative lung perfusion scan and CT angiography showed near normal left pulmonary blood flow. The patient was discharged on the postoperative 9th day without any postoperative complication.

  • PDF

Clinical Significance of Myocardial Uptake on F-18 FDG PET/CT Performed in Oncologic Patients (종양 환자의 F-18 FDG PET/CT에서 관찰된 심근 섭취의 임상적 의미)

  • Cho, Ho-Jin;Cho, Arthur;Lee, Jong-Doo;Kang, Won-Jun
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.6
    • /
    • pp.519-525
    • /
    • 2009
  • Purpose: F-18 fluorodeoxyglucose (FDG) uptake of myocardium is influenced by various factors. Increased glycolysis, and subsequent increased F-18 FDG uptake has been reported in ischemic cardiomyopathy. However, clinical significance of incidentally found myocardial F-18 FDG uptake has not been clarified. We retrospectively reviewed the degree and pattern of myocardial uptake in patients without history of ischemic heart disease who underwent torso F-18 FDG PET/CT for evaluation of neoplastic disease. Materials and Methods: From January 2005 to June 2009, 77 patients who underwent F-18 FDG PET/CT and Tc-99m sestamibi stress/rest SPECT within 3 months were enrolled. Results: Of 77 patients, 55 (71.4%) showed increased F-18 FDG uptake in the myocardium. In this population, 40 showed uniform uptake pattern, while 15 showed focal uptake. In patients with uniform uptake, 17 showed decreased uptake in the septum without perfusion defect on myocardial SPECT. Remaining 23 patients showed uniform uptake, with 1 reversible perfusion defect and 1 fixed perfusion defect. In 15 patients with focal uptake, 9 showed increased F-18 FDG uptake in the base, and only 1 of them showed reversible perfusion defect on myocardial SPECT. In the remaining 6 focal uptake group, 4 had reversible perfusion defect in the corresponding wall, and 1 had apical hypertrophy. Conclusion: We demonstrated that septal defect pattern and basal uptake pattern in the myocardium may represent normal variants. Focal myocardial uptake other than normal variants on oncologic torso F-18 FDG PET/CT with routine fasting protocol may suggest ischemic heart disease, thus further evaluation is warranted.

A Study on the Radiation Exposure Dose of Brain Perfusion CT Examination a Phantom (Phantom을 이용한 뇌 관류 CT검사에서 방사선 피폭선량에 관한 연구)

  • Jung, Hong-Rynag;Kim, Ki-Jeong;Mo, Eun-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.287-294
    • /
    • 2015
  • The purpose of this study, was Let's examine the exposure dose at the time of cerebral blood flow CT scan of acute ischemic stroke patients. In particular, long-term high doses of radiation sensitive organs and we Measured using phantom and a glass dosimeter. Apply the existing protocol suggested by the manufacturer (fixed time delay technique) and the proposed new convergence protocol (bolus tracking technique), reporting to measure the dose, dose reduction was to prepare the way. Results up to 39.8% as compared to the existing protocols in a new suggested convergence protocol, a minimum of 5.8% was long-term dose is reduced. Test dose of $CDTI_{vol}$ and DLP values decreased 25%, respectively, were measured at less than recommended dose. Try checking the protocol set out in the existing based on the analysis result of the above, by applying the proposed new convergence protocol by reducing the dose would have to contribute to improved public health. It is believed to be research continues to find the optimum protocol in the other tests.

The Effectiveness of Spiral Computed Tomography as a Diagnostic Tool in Pulmonary Embolism(Comparison of Spiral CT with Ventilation-Perfusion Scan) (폐색전증 진단의 도구로서의 Spiral Computed Tomography의 유용성(폐환기관류주사와의 비교))

  • Koh, Jae-Hyun;Oh, Eun-Young;Park, Jung-Ho;Park, Sang-Joon;Yun, Jung-Hwan;Park, Jung-Woong;Suh, Gee-Young;Chung, Man-Pyo;Lee, Kyung-Soo;Kwon, O-Jung;Rhee, Chong-H.
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.4
    • /
    • pp.564-573
    • /
    • 1999
  • Background: With variable symptoms and nonspecific radiographic appearances, pulmonary embolism (PE) is a frequent and often undiagnosed cause of mortality and morbidity. The Prospective Investigation of Pulmonary Embolism Diagnosis (PIOPED) study suggested that the majority of patients undergoing ventilation-perfusion (V-Q) scan would require additional studies to establish or to exclude the diagnosis of PE. Pulmonary angiography has been regarded as gold standard for diagnosis of PE. However, it is an invasive procedure that may be associated with significant notable morbidity and mortality. Thus, availability of an accurate, noninvasive screening examination is highly desirable. Method: From October 1994 to February 1997, twenty patients (male 13, female 7, range 23-91 years, median 58 years) who were suspected as pulmonary embolism on the basis of clinical evidence and underwent the spiral volumetric computed tomography (spiral CT), were studied retrospectively to evaluate the effectiveness of spiral CT as a diagnostic tool in PE. Results: PE could be excluded with spiral CT in 4 patients ; diagnoses of these patients were lung cancer, pneumonia with lung abscess, bilateral pleural effusion due to congestive heart failure, nonspecific pulmonary abnormality retrospectively. One patient who disclosed high probability in V/Q scan, could be diagnosed as pneumonia with lung abscess and underlying emphysema with spiral CT. Among 4 patients who showed intermediate and low probability in V/Q scan, 3 patients could be confirmed as PE with spiral CT. Spiral CT was helpful in 3 patients, in whom V/Q scan could not be performed due to other reasons (e.g. night time, mechanical ventilation) to confirm the diagnosis of PE. Spiral CT could demonstrate embolus above lobar artery level in 11 patients, and up to segmental artery level in 5 patients. Conclusion: This study demonstrated that spiral CT could allow accurate demonstration of thrombotic clots in centrally localized embolism. Spiral CT could be effective, specific, noninvasive and useful diagnostic screening modality for the diagnosis of pulmonary embolism.

  • PDF

Evaluation and Comparison of Myocardial Perfusion Defects in Patients with Early Breast Cancer Subjected to Different Radiation Simulation Techniques (조기유방암 환자에서 방사선 모의치료 방법의 차이에 따른 심근관류결손의 비교 평가)

  • Nam, Ji-Ho;Ki, Yong-Kan;Kim, Dong-Won;Kim, Won-Taek
    • Radiation Oncology Journal
    • /
    • v.25 no.1
    • /
    • pp.26-33
    • /
    • 2007
  • [ $\underline{Purpose}$ ]: The aim of this study is to evaluate and compare the incidence and aspects of myocardial perfusion defects in patients who were subjected to either two-dimensional or three-dimensional simulation techniques for early left-sided breast cancer. The myocardial perfusion defects were determined from using single photon emitted computerized tomography (SPECT) myocardial perfusion images. $\underline{Materials\;and\;Methods}$: Between January 2002 and August 2003, 32 patients were enrolled in this study. The patients were diagnosed as having early (AJCC stage T1-T2N0M0) left-sided breast cancer and were treated with tangential irradiation after breast-conserving surgery and systemic chemotherapy. The patients were divided into two groups according to the type of simulation received: two-dimensional simulation using an X-ray fluoroscope simulator or three-dimensional simulation with a CT simulator. All patients underwent technetium-99m-sestamibi gated perfusion SPECT at least 3 years after radiotherapy. The incidence and area of myocardial perfusion defects were evaluated and were compared in the two groups, and at the same time left ventricular ejection fraction and cardiac wall motion were also analyzed. The cardiac volume included in the radiation fields was calculated and evaluated to check for a correlation between the amount of irradiated cardiac volume and aspects of myocardial perfusion defects. $\underline{Results}$: A myocardial perfusion defect was detected in 11 of 32 patients (34.4%). There were 7 (46.7%) perfusion defect cases in 15 patients who underwent the two-dimensional simulation technique and 4 (23.5%) patients with perfusion defects in the three-dimensional simulation group (p=0.0312). In 10 of 11 patients who had myocardial perfusion changes, the perfusion defects were observed in the cardiac apex. The left ventricular ejection fraction was within the normal range and cardiac wall motion was normal in all patients. The irradiated cardiac volume of patients in the three-dimensional simulation group was less than that of patients who received the two-dimensional simulation technique, but there was no statistical significance as compared to the incidence of perfusion defects. $\underline{Conclusion}$: Radiotherapy with a CT simulator (three-dimensional simulation technique) for early left-sided breast cancer may reduce the size of the irradiated cardiac volume and the incidence of myocardial perfusion defects. Further investigation and a longer follow-up duration are needed to analyze the relationship between myocardial perfusion defects and clinical ischemic heart disease.