대규모 실내경기장의 성능위주 방재계획에 관한 연구 (A Study on Perfomance Based Evacuation Plan for a Large Indoor-Arena)

  • 최용석;김형근;이규일
    • 설비공학논문집
    • /
    • 제23권10호
    • /
    • pp.687-698
    • /
    • 2011
  • In this study, it was analyzed by a numerical analysis that plan/design considerations for ensuring the spectator safety of large arena audiences in a fire emergency evacuation plan. The latest issue, the 'performance-based design', fire and evacuation plan is important. But nowadays 'Specification-based design' is in common. In evacuation simulation, congestion of exit and aisle is ignored because only evacuation time of large-space is mainly analyzed. In smoke flow,'smoke filling effect' tends to be overrated. From now on, when design a field house, it is needed not 'smoke filling effect' and 'large-space evacuation' analysis, but analyzing 'whole building evacuation time' for ensuring fire evacuation safety of spectator.

지하주차장 성능위주설계의 피난안전성 평가 개선에 관한 연구 (A Study on Improvement of Evacuation Safety Evaluation for Performance Based Design in Underground Parking Lot)

  • 송영주;공일천;김학중
    • 한국화재소방학회논문지
    • /
    • 제33권2호
    • /
    • pp.85-97
    • /
    • 2019
  • 오늘날 인간의 삶의 질 향상과 다양한 욕구를 충족시키기 위한 건축물은 대형화, 고층화, 심층화, 복합화 되는 추세이며, 이에 따른 비정형화된 공간이 새롭게 창출되면서 성능위주설계대상도 증가하고 있다. 성능위주설계의 피난안전성 평가는 ASET과 RSET를 산정 비교하여 RSET이 ASET를 초과하지 않도록 하여야 한다. 그러나 지하 주차장과 같이 구획된 공간의 면적이 넓고 피난경로가 다양한 경우 현재 시행되고 있는 성능위주설계 평가 방법만으로 모든 피난경로에서 안전성을 확보하기 어려운 문제가 있다. 따라서 본 논문에서는 이러한 문제점을 극복하기 위해 현재 사용되고 있는 성능위주설계의 시뮬레이션 설정방법에 대해 먼저 고찰한 다음 지하 주차장을 대상으로 화재시뮬레이션 2가지와 피난시뮬레이션 3가지 경우를 각각 수행하여 6가지 경우에 대한 피난안전성 평가를 실시하고 비교 평가하여 문제점을 살펴보고 개선된 성능위주설계의 피난안전성 평가 방안을 제시한다.

대규모 위락시설의 피난안전성능 평가에 관한 연구 (A Study on Safety Assessment of the Evacuation at the Large-scale Amusement Facilities)

  • 박봉래;공하성
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.165-173
    • /
    • 2009
  • 성능위주의 설계가 법제화 되면서 화재 및 피난에 대한 연구가 활발히 진행 중이다. 성능위주설계는 인명의 안전성을 증대 시키는 방향으로 발전되어야 한다. 또한, 성능위주의 설계는 소방분야뿐만 아니라 건축법령에서 정하고 있는 피난에 관한 규정을 포함하여 검토되어야 한다. 본 논문은 성능위주의 설계 시 참고가 될 자료로 제시하기위해 다중이용시설인 광주광역시의 OO나이트클럽을 하나의 모델로 삼아 피난시간을 예측하였다. 이를 위해 우리나라와 외국의 피난에 관련된 규정과 연구논문들을 검토하고, 현장을 방문하여 자료를 수집하였다. 그리고 수집된 자료들을 피난프로그램인 Simulex의 입력 자료로 사용하여 피난시간을 측정하였다. 이 연구의 검토과정 및 결과에서 몇 가지 문제시되는 사항을 발견할 수 있었다.

성능위주 화재와 피난시뮬레이션 입력데이터의 표준화 필요성에 대한 제안 (Proposals on the Input Data Standardization Needs of Fire and Evacuation Simulation in Performance Based Design)

  • 장근호
    • 한국화재소방학회논문지
    • /
    • 제30권5호
    • /
    • pp.18-25
    • /
    • 2016
  • 국내 성능위주설계 방법 및 기준에서는 다양한 입력 데이터들에 대한 입력 규정이 따로 마련되어있지 않으며, 설계자별로 인용하는 근거 데이터가 상이하여 피난허용시간과 피난완료시간에 많은 차이를 보이고 있다. 이는 성능위주 화재와 피난 시뮬레이션에 대한 신뢰도 문제와도 직결되고 있다. 시뮬레이션에 입력되는 다양한 데이터들을 표준화함으로서 설계자의 경험이나 기술능력에 무관하게 동일한 위험도의 건물에서는 동일한 결과가 도출되어야 한다. 또한 그 위험도 합당한 소방 방재설비가 설치되고 유사한 성능위주 대상 건물에서는 개연성 있는 초기투자비용이 소요됨으로서 효율적이고 효과적인 안전 확보가 이루어져야 할 것으로 판단된다.

건축물의 화재 시 피난안전성 평가 개선을 위한 시뮬레이션 분석 연구 (A Study on the Analysis of Simulation for Improvement Evacuation Safety Assessment of Building in Fire)

  • 김혜원;김윤성;이병흔;진승현;구인혁;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.107-108
    • /
    • 2020
  • There is a need to analyze various factors in evacuation safety assessment of building in fire. In the current performance based design, evacuation safety assessment in case of fire is being conducted through the simulation as FDS and Pathfinder. However, the location and size of the door, the location of evacuation in the event of a fire are not considered when design. Accordingly, it is difficult to determine the worst case scenario considering the actual fire. Therefore in this study, in this study, we will propose an appropriate evaluation plan through simulation considering the worst-case scenario that may occur in case of fire.

  • PDF

A Study on the Evacuation Performance According to Variation in Remoteness between Exit Stairways in Tall Buildings

  • Han, Gisung;Kim, Tae-Young;Lee, Kyung-Hoon
    • Architectural research
    • /
    • 제22권2호
    • /
    • pp.53-61
    • /
    • 2020
  • The purpose of this study is to examine the influence of remoteness between exit stairways on evacuation performance. Firstly, we reviewed the design regulations of the U.S., the U.K., and South Korea, in relation to remoteness between Exit stairways. Secondly, evacuation simulation was implemented, in order to evaluate the adequacy of each standard. Eight tall buildings in South Korea were selected for the simulation. Evacuation performance was assessed for different remote distances between Exit stairways. Lastly, this research analyses the evacuation simulation data statistically in relation to the effect of remoteness on evacuation time. We found that as the distance between two exit stairways increases, the total evacuation time and average evacuation time for evacuees decreases. There was no statistical influence between the maximum travel distance of the evacuee and the remoteness between two exit stairways, but there was a significant effect on the average travel distance of the evacuees. In addition, the results from the optimal point showed that the L_ratio had the highest evacuation time at 0.44, while the D_ratio had the highest evacuation time at 0.38.

공동주택 및 오피스텔 지하층에 대한 피난 안전성 평가 (Evacuation Safety Evaluation for Apartment Complexes and Officetel under Floors)

  • 강현권;전용한
    • 대한안전경영과학회지
    • /
    • 제25권4호
    • /
    • pp.67-72
    • /
    • 2023
  • Human and material damage can be reduced if the risk is evaluated by engineering analysis of fire combustion products, smoke concentration, and smoke movement speed in the event of a fire in apartment houses and officetels. In this study, a lot of research on related safety evaluation in the basement needs to be studied and reflected in design, so experimental research was conducted to analyze the flow of smoke through computer simulation and provide analysis data through evacuation safety evaluation. First of all, the five-story underground parking lot subject to simulation has a large floor area, which is advantageous for improving evacuation safety performance, but it uses temperature detectors to increase detection time and fire spread speed. Second, it was analyzed that the evacuation time at all evacuation ports did not exceed the evacuation time, and as the time from the start of evacuation to the evacuation time was 216.9% compared to the travel time, it was evaluated that the safety performance of the evacuation was secured. Third, the above simulation results are a comprehensive safety evaluation based on the non-operation of fire extinguishing facilities in the fire room to increase safety, which means that smoother evacuation safety performance can be secured by linking fire extinguishing facilities.

노인 요양병원에서 화재 시 군집유형에 따른 피난 성능 분석 모델에 관한 연구 (A Study on the Evacuation Performance Analysis Model Considering Clustering Types at the Fire Event in Geriatric Hospital)

  • 김미정;권지훈
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제28권1호
    • /
    • pp.63-74
    • /
    • 2022
  • Purpose: The purpose of this study is to present an evacuation performance analysis model that can derive vulnerable evacuation spaces with considering the movement behavior as per the elderly groups in the event of a fire in a geriatric hospital. Methods: The evacuation characteristics of geriatric hospital users were investigated through the review of precedent studies. First, the occupant conditions and the evacuation scenario were set to analyze a study target hospital. Then, the evacuation simulation was carried out considering the group types and the density of each group. Finally, an evacuation performance analysis model according to the group type was presented based on the simulation results. Results: The results of this study are as follows: (1) The evacuation performance according to the group type is to be clarified through the suggested study model. (2) It is necessary to secure a ramp or an emergency elevator to distribute the evacuation personnel at the design stage because congestion occurs due to collisions between evacuees on the stairs and delays the evacuation time. (3) It is necessary to consider the evacuation stairs and openings of sufficient size by analyzing the frequency of congestion occurrence and the escape routes of occupants in advance to identify the space where the evacuation flow overlaps. Implications: It is expected that the study result is to be used as primary data for studies that consider the elderly and clustering evacuation behavior in the event of a fire in a geriatric hospital.

사회복지관 피난모델링을 통한 시나리오 개발의 필요성 (The Need for Developiong Scenarios through Social Welfare Facility Evacuation Modeling)

  • 김진하;김서영;공하성
    • 대한안전경영과학회지
    • /
    • 제25권2호
    • /
    • pp.29-38
    • /
    • 2023
  • Social welfare facilities are used by a wide range of local residents, including vulnerable populations such as the elderly, children, and people with disabilities. During emergencies like fires, confusion can arise as these individuals try to evacuate. Evacuation simulation results have shown that utilizing evacuation systems based on specific evacuation scenarios can significantly decrease the time required for evacuation compared to general evacuation procedures. By anticipating potential fires based on changes in social and facility environments, appropriate evacuation scenarios can be developed and applied to evacuation systems, thus contributing to the safety and security of individuals during emergencies. In conclusion, for social welfare facilities that serve a large number of people, it is necessary to expand the focus on performance-based design depending on the size of the facility, and to continuously develop and train for appropriate evacuation scenarios that align with changing facility environments.

Flexible Intelligent Exit Sign Management of Cloud-Connected Buildings

  • Lee, Minwoo;Mariappan, Vinayagam;Lee, Junghoon;Cho, Juphil;Cha, Jaesang
    • International Journal of Advanced Culture Technology
    • /
    • 제5권1호
    • /
    • pp.58-63
    • /
    • 2017
  • Emergencies and disasters can happen any time without any warning, and things can change and escalate very quickly, and often it is swift and decisive actions that make all the difference. It is a responsibility of the building facility management to ensure that a proven evacuation plan in place to cover various worst scenario to handled automatically inside the facility. To mapping out optimal safe escape routes is a straightforward undertaking, but does not necessarily guarantee residents the highest level of protection. The emergency evacuation navigation approach is a state-of-the-art that designed to evacuate human livings during an emergencies based on real-time decisions using live sensory data with pre-defined optimum path finding algorithm. The poor decision on causalities and guidance may apparently end the evacuation process and cannot then be remedied. This paper propose a cloud connected emergency evacuation system model to react dynamically to changes in the environment in emergency for safest emergency evacuation using IoT based emergency exit sign system. In the previous researches shows that the performance of optimal routing algorithms for evacuation purposes are more sensitive to the initial distribution of evacuees, the occupancy levels, and the type and level of emergency situations. The heuristic-based evacuees routing algorithms have a problem with the choice of certain parameters which causes evacuation process in real-time. Therefore, this paper proposes an evacuee routing algorithm that optimizes evacuation by making using high computational power of cloud servers. The proposed algorithm is evaluated via a cloud-based simulator with different "simulated casualties" are then re-routed using a Dijkstra's algorithm to obtain new safe emergency evacuation paths against guiding evacuees with a predetermined routing algorithm for them to emergency exits. The performance of proposed approach can be iterated as long as corrective action is still possible and give safe evacuation paths and dynamically configure the emergency exit signs to react for real-time instantaneous safe evacuation guidance.