• Title/Summary/Keyword: performance test

Search Result 21,764, Processing Time 0.055 seconds

A Complexity Reduction Method of MPEG-4 Audio Lossless Coding Encoder by Using the Joint Coding Based on Cross Correlation of Residual (여기신호의 상관관계 기반 joint coding을 이용한 MPEG-4 audio lossless coding 인코더 복잡도 감소 방법)

  • Cho, Choong-Sang;Kim, Je-Woo;Choi, Byeong-Ho
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.3
    • /
    • pp.87-95
    • /
    • 2010
  • Portable multi-media products which can service the highest audio-quality by using lossless audio codec has been released and the international lossless codecs, MPEG-4 audio lossless coding(ALS) and MPEG-4 scalable lossless coding(SLS), were standardized by MPEG in 2006. The simple profile of MPEG-4 ALS, it supports up to stereo, was defined by MPEG in 2009. The lossless audio codec should have low-complexity in stereo to be widely used in portable multi-media products. But the previous researches of MPEG-4 ALS have focused on an improvement of compression ratio, a complexity reduction in multi-channels coding, and a selection of linear prediction coefficients(LPCs) order. In this paper, the complexity and compression ratio of MPEG-4 ALS encoder is analyzed in simple profile of MPEG-4 ALS, the method to reduce a complexity of MPEG-4 ALS encoder is proposed. Based on an analysis of complexity of MPEG-4 ALS encoder, the complexity of short-term prediction filter of MPEG-4 ALS encoder is reduced by using the low-complexity filter that is proposed in previous research to reduce the complexity of MPEG-4 ALS decoder. Also, we propose a joint coding decision method, it reduces the complexity and keeps the compression ratio of MPEG-4 ALS encoder. In proposed method, the operation of joint coding is decided based on the relation between cross-correlation of residual and compression ratio of joint coding. The performance of MPEG-4 ALS encoder that has the method and low-complexity filter is evaluated by using the MPEG-4 ALS conformance test file and normal music files. The complexity of MPEG-4 ALS encoder is reduced by about 24% by comparing with MPEG-4 ALS reference encoder, while the compression ratio by the proposed method is comparable to MPEG-4 ALS reference encoder.

Sugar-sweetened beverage consumption and influencing factors in Korean adolescents: based on the 2017 Korea Youth Risk Behavior Web-based Survey (한국 청소년의 가당음료 섭취실태 및 영향요인 : 2017년 청소년건강행태온라인조사 이용)

  • Kim, Ayoung;Kim, Jinhee;Kye, Seunghee
    • Journal of Nutrition and Health
    • /
    • v.51 no.5
    • /
    • pp.465-479
    • /
    • 2018
  • Purpose: This study examined the frequency of sugar-sweetened beverage consumption in Korean adolescents and the major factors influencing the excessive consumption of sugar-sweetened beverages, such as sociodemographic characteristics, health-related behaviors, psychological characteristics, and dietary habits. Methods: The analysis was performed using the data from the 2017 Korean Youth Risk Behavior Web-based Survey. The subjects included in the analysis were 30,885 middle school students and 31,391 high school students, totaling 62,276. The frequency of sugar-sweetened beverage consumption was calculated by summing the consumption frequencies of soda, high caffeine or energy drinks, and sweet beverages over the last 7 days. The Rao-Scott chi-square test, reflecting information on the sampling design, was used to test the differences in the rate of sugar-sweetened beverage consumption according to each factor. Logistic regression analysis was performed to examine the factors influencing the excessive consumption of sugar-sweetened beverages. Results: The rate of sweetened beverage consumption was higher in boys than in girls, in high school students than in middle school students, in students whose father's education level was lower, in those whose subjective academic performance was lower, and in those who smoked or consumed alcohol. In addition, the rate of sugar-sweetened beverage consumption was higher in those who experienced severe stress, suicidal ideation, sadness, or a sense of despair. The rate of sugar-sweetened beverage consumption was also high in those who skipped breakfast; who frequently consumed fast foods, ramen, or snacks; and who frequently ate meals at convenience stores, supermarkets, or school stores. Conclusion: The rate of sugar-sweetened beverage consumption in Korean adolescents is related to various factors, such as sociodemographic characteristics, health-related behaviors, psychological characteristics, and dietary habits.

Evaluation for Optimization of CT Dose Reduction Methods in PET/CT (PET/CT 검사 시 CT 피폭선량 감소 방법들의 최적화 평가)

  • Do, Yong Ho;Lee, Hong Jae;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.55-62
    • /
    • 2015
  • Purpose Various methods for reducing radiation exposure have been continuously being developed. The aim of this study is to evaluate effectiveness of dose reduction, image quality and PET SUV changes by applying combination of automatic exposure dose(AEC), automated dose-optimized selection of X-ray tube voltage(CAREkV) and sinogram affirmed iterative reconstruction(SAFIRE) which can be controled by user. Materials and Methods Torso, AAPM CT performance and IEC body phantom images were acquired using biograph mCT64, (Siemens, Germany) PET/CT scanner. Standard CT condition was 120 kV, 40 mAs. Radiation exposure and noise were evaluated by applying AEC, CAREkV(120 kV, 40 mAs) and SAFIRE(120 kV, 25 mAs) with torso phantom compare to standard CT condition. And torso, AAPM and IEC phantom images were acquired with combination of 3 methods in condition of 120 kV, 25 mAs to evaluate radiation exposure, noise, spatial resolution and SUV changes. Results When applying AEC, CTDIvol and DLP were decreased by 50.52% and 50.62% compare to images which is not applying AEC. mAs was increased by 61.5% to compensate image quality according to decreasing 20 kV when applying CAREkV. However, CTDIvol and DLP were decreased by 6.2% and 5.5%. When reference mAs was the lower and strength was the higher, reduction of radiation exposure rate was the bigger. Mean SD and DLP were decreased by 2.2% and 38% when applying SAFIRE even though mAs was decreased by 37.5%(from 40 mAs to 25 mAs). Combination of 3 methods test, SD decreased by 5.17% and there was no significant differences in spatial resolution. And mean SD and DLP were decreased by 6.7% and 36.9% compare to 120 kV, 40 mAs with AEC. For SUV test, there was no statistical differences(P>0.05). Conclusion Combination of 3 methods shows dose reduction effect without degrading image quality and SUV changes. To reduce radiation exposure in PET/CT study, continuous effort is needed by optimizing various dose reduction methods.

  • PDF

Formaldehyde Monitoring of Hygiene Products in Domestic Market (국내 유통 위생용품 중 포름알데히드 잔류량 모니터링)

  • Na, Young-Ran;Kwon, Hyeon-Jeong;Cho, Hyun-Nho;Kim, Hyeon-Jin;Park, Yon-Koung;Park, Sung-Ah;Lee, Seong-Ju;Kang, Jung-Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.3
    • /
    • pp.225-233
    • /
    • 2020
  • By the standards and specifications for hygiene products, three test methods for formaldehyde are specified for each item type of hygiene product. After derivatization using acetylacetone and 2,4-dinitrophenylhydrazine (2,4-DNPH), formaldehyde is analyzed by spectrophotometer and high-performance liquid chromatography (HPLC). Validation of the three test methods was performed on tissue, diaper lining and waterproof layer, and panty liner products. The results of linearity (R2), limit of detection (LOD), limit of quantification (LOQ), recovery rate (%) and reproducibility (%), showed that all three methods are suitable for analyzing formaldehyde in hygiene products. After derivatization with 2,4-DNPH and cetylacetone, formaldehyde was analyzed at 0, 3, 6, 9, 24 and 48 hours by HPLC. Formaldehyde derivatized with 2,4-DNPH showed no statistically significant change in formaldehyde peak area over time (P>0.05). But, acetylacetone-derivatizated formaldehyde showed a negative correlation coefficient (r) over time (P<0.01). We investigated the residual amounts of formaldehyde in 205 hygiene products distributed in Busan. Among 74 disposable diaper products tested, 73 had low concentrations of formaldehyde (0.13-29.87 mg/kg). Moreover, formaldehyde was not detected in any of 78 tissue, 27 disposable paper towel, 12 disposable dishcloth, 7 paper cup, one brand of paper straw and 6 disposable napkin products.

Brown Color Characteristics and Antioxidizing Activity of Doenjang Extracts (된장의 지용성ㆍ수용성추출물에 대한 갈색 특성 및 항산화 효과)

  • 김현정;손경희;채선희;곽동경;임성경
    • Korean journal of food and cookery science
    • /
    • v.18 no.6
    • /
    • pp.644-654
    • /
    • 2002
  • Brown color characteristics and antioxidizing activities were investigated for Doenjang under different processing conditions. Doenjang A was prepared directly from Meju and saline solution whereas Doenjang B was Prepared after separating soy sauce by soaking for 45 days. Both Doenjangs were aged for up to 180 days. Antioxidizing activity was studied in relation to the brown color characteristics using fat-soluble extract and water-soluble extract of Doenjang. The intensity of brown color was higher in the water-soluble Doenjang extract than the fat-soluble Doenjang extract. In the UV-VIS scanning spectra, water-soluble Doenjang extracts showed significant changes as the aging proceeded, but fat-soluble Doenjang extract did not. Antioxidizing activity of fat-soluble Doenjang extract increased as the aging period extended; however, no significant difference was detected in the water-soluble extract. Overall, Doenjang A showed higher contents of amino acids, reducing sugar, brown color, and antioxidizing activity, and the antioxidizing ability was higher in water-soluble Doenjang extract rather than in the fat-soluble Doenjang extract.

Reduction of Injection Dose in 18F-FDG Fusion PET (PET-CT 검사에서 18F-FDG 투여량 감소에 대한 고찰)

  • Kim, Jong-Pil;Kim, Jae-Il;Lee, Hong-Jae;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.17-21
    • /
    • 2014
  • Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of $^{18}F$-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the $^{18}F$-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of $^{18}F$-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected $^{18}F$-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in $^{18}F$-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment's performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient's anxiety of the radiation exposure.

  • PDF

The Results of Palliative Radiation Therapy in Patients with Unresectable Advanced Pancreatic Cancer (절제 불가능한 췌장암의 고식적 방사선치료 결과)

  • Ryu, Mi-Ryeong;Yoon, Sei-Chul;Kim, Yeon-Sil;Chung, Su-Mi
    • Radiation Oncology Journal
    • /
    • v.24 no.4
    • /
    • pp.243-247
    • /
    • 2006
  • $\underline{Purpose}$: To evaluate the treatment results and prognostic factors of palliative radiation therapy in the patients with unresectable advanced pancreatic cancer. $\underline{Materials\;&\;Methods$: Thirty-seven evaluable patients with unresectable advanced pancreatic cancer who were treated by palliative radiation therapy for pain relief at the Department of Radiation Oncology, Kangnam St. Mary's hospital, the Catholic University of Korea between March 1984 and February 2005 were analysed retrospectively. There were 22 men and 15 women. Age at diagnosis ranged from 30 to 80 (median 57) years. Twelve patients (32.4%) had liver metastases and 22 patients (59.5%) had lymph node metastases. Radiation therapy was delivered to primary tumor and regional lymph nodes with $1{\sim}2\;cm$ margin, and total dose was $3,240{\sim}5,580\;cGy$ (median 5,040 cGy). Chemotherapy with radiotherapy was delivered in 30 patients (81%) with 5-FU alone (21 patients) or gemcitabine (9 patients). The follow-up period ranged from 1 to 44 months. Survival and prognostic factors were analysed using Kaplan-Meier method and log-rank test respectively. $\underline{Results}$: Overall mean and median survival were 11 and 8 months and 1-year survival rate was 20%. Among 33 patients who were amenable for response evaluation, 7 patients had good response and 22 patients had fair response with overall response rate of 87.9%. Mild to moderate toxicity were observed in 14 patients with nausea, vomiting, and indigestion, but severe toxicity requiring interruption of treatment were not observed. Chemotherapy didn't influence the survival and symptomatic palliation, but the group containing gemcitabine showed a tendency of longer survival (median 12 months) than 5-FU alone group (median 5.5 months) without statistical significance (p>0.05). The significant prognostic factors were Karnofsky performance status and liver metastasis (p<0.05). Age, sex, tumor location, lymph node metastasis, and CA 19-9 level did not show any prognostic significance (p>0.05). $\underline{Conclusion}$: Radiation therapy was effective for symptomatic palliation in the patients with unresectable advanced pancreatic cancer and would play an important part in the survival benefit with gemcitabine or other targeted agents.

Criteria of Evaluating Clothing and Web Service on Internet Shopping Mall Related to Consumer Involvement (인터넷 쇼핑몰 이용자의 소비자 관여에 따른 의류제품 및 웹 서비스 평가기준에 관한 연구)

  • Lee, Kyung-Hoon;Park, Jae-Ok
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.12 s.159
    • /
    • pp.1747-1758
    • /
    • 2006
  • Rapid development of the information technology has influenced on the changes in every sector of human environments. One prominent change in retail market is an increase of electronic stores, which has prompted practical and research interest in the product and store attributes that include consumer to purchase products from the electronic shopping. Therefore many marketers are paying much attention to the criteria of evaluating clothing and web service on internet shopping malls. The purpose of this study is to examine differences of clothing and web service criteria of consumer groups (High-Involvement & High-Ability, Low-Involvement & High-Ability, High-Involvement & Low-Ability, and Low-Involvement & Low-Ability) who are classified into consumer involvement and internet use ability. The subjects of this study were 305 people aged between 19 and 39s, living in Seoul and Gyeonggi-do area, and having experiences in buying products on the internet shopping. Statistical analyses used for this study were the frequency, percentage, factor analysis, ANOVA and Duncan test. The results of this study were as follows: Regarded on the criteria of evaluating clothing, the low different groups had significant differences in the esthetic, the quality performance and the extrinsic criterion. Both HIHA group and HILA group showed the similar results. They considered every criterion of evaluating clothing more important, compared with other groups. Regarded on the criteria of evaluating web service related to the low different groups, there were significant differences in the factors related to the shopping mall reliance, the product, the satisfaction after purchase, and the promotion and policy criterion. Both HIHA group and HILA group showed the similar results as well. They considered every criterion of evaluating web service more important, compared with other groups. In conclusion, HI groups perceive relatively more dangerous factors which can be occurred during internet shopping. Therefore, internet shopping malls need to provide clothing that can satisfy the HI groups as well as make efforts to remove the dangerous factors on the internet.

Simultaneous Analysis for Veterinary Drug Residues in Honey by HPLC/MS/MS (HPLC-MS/MS를 이용한 벌꿀 중 동물용의약품 동시분석방법 연구)

  • Kim, Jong-Hwa;Moon, Sun-Ea;Kim, Ki-Yu;Jung, You-Jung;Lee, Chang-Hee;Ku, Eun-Jung;Yoon, Mi-Hye;Lee, Jong-Bok
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.2
    • /
    • pp.94-98
    • /
    • 2016
  • This study was conducted to establish the simultaneous analysis method for veterinary drug residues in honey by high performance liquid chromatography tandem mass spectrometry (HPLC/MS/MS). The eleven targeting veterinary drugs with honey test method in Korean Food Standards Codex were divided into Group 1 (streptomycine dihydrostreptomycine, neomycine) and Group 2 (oxytetracycline, enrofloxacin, ciprofloxacin, cymiazole, chloramphenicol, amitraz, coumaphos, fluvalinate) to be analyzed simultaneously. From the results, the retention time (RT) of the targeting drugs was within 15 min, the range of detection limits was 0.0056 to $0.0643{\mu}g/g$ and the range of quantification limits was 0.0169 to $0.1948{\mu}g/g$. The coefficients of determination ($R^2$) for Group 1 ($0.05{\sim}1.0{\mu}g/mL$) and Group 2 ($0.01{\sim}1.0{\mu}g/mL$) were 0.9917~0.9987 and 0.9923~1.000 respectively, and showed the good linearity. The recovery rates for Group 1 (final conc. $0.25{\mu}g/g$) and Group 2 (final conc. $1.0{\mu}g/g$) were 65.1~80.6% and 64.2~90.3% respectively. Also, the analysis results of inter day (n = 3) and intra day (n = 6) RSD (%) for area and retention time showed that the RSD (%) for area and retention time was below 10.92% and 1.57%. Therefore, the simultaneous analysis method of this study is evaluated to be a good test method for veterinary drug residues in honey.

The Accuracy Evaluation according to Dose Delivery Interruption and Restart for Volumetric Modulated Arc Therapy (용적변조회전 방사선치료에서 선량전달의 중단 및 재시작에 따른 정확성 평가)

  • Lee, Dong Hyung;Bae, Sun Myung;Kwak, Jung Won;Kang, Tae Young;Back, Geum Mun
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.1
    • /
    • pp.77-85
    • /
    • 2013
  • Purpose: The accurate movement of gantry rotation, collimator and correct application of dose rate are very important to approach the successful performance of Volumetric Modulated Arc Therapy (VMAT), because it is tightly interlocked with a complex treatment plan. The interruption and restart of dose delivery, however, are able to occur on treatment by various factors of a treatment machine and treatment plan. If unexpected problems of a treat machine or a patient interrupt the VMAT, the movement of treatment machine for delivering the remaining dose will be restarted at the start point. In this investigation, We would like to know the effect of interruptions and restart regarding dose delivery at VMAT. Materials and Methods: Treatment plans of 10 patients who had been treated at our center were used to measure and compare the dose distribution of each VMAT after converting to a form of digital image and communications in Medicine (DICOM) with treatment planning system (Eclipse V 10.0, Varian, USA). We selected the 6 MV photon energy of Trilogy (Varian, USA) and used OmniPro I'mRT system (V 1.7b, IBA dosimetry, Germany) to analyze the data that were acquired through this measurement with two types of interruptions four times for each case. The door interlock and the beam-off were used to stop and then to restart the dose delivery of VMAT. The gamma index in OmniPro I'mRT system and T-test in Microsoft Excel 2007 were used to evaluate the result of this investigation. Results: The deviations of average gamma index in cases with door interlock, beam-off and without interruption on VMAT are 0.141, 0.128 and 0.1. The standard deviations of acquired gamma values are 0.099, 0.091, 0.071 and The maximum gamma value in each case is 0.413, 0.379, 0.286, respectively. This analysis has a 95-percent confidence level and the P-value of T-test is under 0.05. Gamma pass rate (3%, 3 mm) is acceptable in all of measurements. Conclusion: As a result, We could make sure that the interruption of this investgation are not enough to seriously affect dose delivery of VMAT by analyzing the measured data. But this investigation did not reflect all cases about interruptions and errors regarding the movement of a gantry rotation, collimator and patient So, We should continuously maintain a treatment machine and program to deliver the accurate dose when we perform the VMAT for the many kinds of cancer patients.

  • PDF