• Title/Summary/Keyword: performance requirement

Search Result 1,885, Processing Time 0.03 seconds

Performance Comparison of Modulation Schemes according to the Dimming Control in MIMO-VLC System (MIMO-VLC에서 디밍제어에 따른 변조방식들의 성능 비교)

  • Lee, Min-Jung;Lee, Byung-Jin;Ju, Sang-Lim;Kim, Yong-Won;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.63-69
    • /
    • 2014
  • Visible light communication is a communication method using an LED's blinking(ON/OFF), it has a feature of light because of the limit of perception by the human's optic nerve. LED' dimming control used in the VLC system is important factor needed to provide energy saving and life benefits. With advances in VLC system, MIMO technology has received much attention in that it can be obtain channel capacity proportionate to the number of antenna. Therefore, in this paper, with RC method which is one of the MIMO style in VLC system, it is compared communication performance using RZ-OOK, VPPM, MPPM and OPPM. As a result of the simulation was run against this, MPPM works well in terms of Power requirement and OPPM works well in terms of Spectral efficiency and Bandwidth requirement, also it was confirmed that there is a significant impact on the communication performance of each modulation scheme according to the dimming.

Development of Torque Assisted Control Method for Integrated Starter/Alternato (토오크 보조 방식의 일체형 스타터 발전기 제어 방식 개발)

  • Oh, Sung-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.1
    • /
    • pp.9-16
    • /
    • 2011
  • Research on ISA(Integrated Starter/Alternator) receives wide attention as system voltage is increased to 42V Based on requirement of starter and alternator for the conventional vehicle, system requirement and specification are determined. Also to control proposed system, suitable control methods are proposed. Main control issues with ISA are whether torque assist is required and if so how much torque is needed. In this paper, vehicle performance with various control methods and capacity are simulated and simulation results are analyzed. Vehicle performance is analyzed with vehicle simulator. For the simulation, suitable ISA model is also developed.

Performance Analysis of UE for WCDMA due to Frequency Error (WCDMA 시스템에서 주파수 에러에 의한 단말기 성능 분석)

  • 이일규;송명선;임인성;이광일;오승엽
    • Proceedings of the IEEK Conference
    • /
    • 2003.07a
    • /
    • pp.461-464
    • /
    • 2003
  • This paper explains the impact of frequency error on the performance of WCDMA mobile communication systems and what brings about the frequency error between the base station and the mobile station, and then presents automatic frequency error correction method in mobile receiver. On the basis of system requirement related to frequency stability, the integration test between the base station and the mobile station was accomplished. After applying automatic frequency error correction to mobile receiver, 4 Hz of frequency error at transmitting frequency was obtained. The result met frequency error requirement of 0.1ppm(about 200 Hz). Performance degradation due to frequency error was measured by means of Error Vector Magnitude (EVM)

  • PDF

A Study on the Performance Requirement of Noise Absorbing Material for Railway tunnel (터널내부 소음 저감을 위한 흡음제 요구성능에 관한 연구)

  • Cho Jun-Ho;Yang Sin-Chu;Kim Hyung-Jun;Yoon Je-Won;Kim Young-Chan
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.479-483
    • /
    • 2003
  • In general, urban railroad in Korea is constructed as a tunnel type under ground due to the various restricted conditions. Passengers in train running through underground tunnel compare to open space are exposed to severe noise environment. In this study, various performance characteristics of many candidate materials are surveyed and analyzed. And some important characteristics are tested. From this study, various performance requirement for noise reduction in railway tunnel were suggested.

  • PDF

A New Dynamic Reliability Assessment for Mid-loop Operations in a Nuclear Power Plant

  • Jae, Moosung
    • International Journal of Reliability and Applications
    • /
    • v.3 no.1
    • /
    • pp.25-35
    • /
    • 2002
  • This paper presents a dynamic reliability assessment methodology for use in the safety assessment of a complex system such as a nuclear power plant. The method is applied to a dynamic analysis of the potential accident sequences that may occur during mid-loop operation in a nuclear power plant. The idea behind this approach consists of both the use of the concept of the performance achievement/requirement correlation and of a dynamic event tree generation method. The assessment of the system reliability depends on the determination of both the required performance distribution and the achieved performance distribution. The quantified correlation between requirement and achievement represents a comparison between two competing variables. It is demonstrated that this method is easily applicable and flexible in that it can be applied to any kind of dynamic reliability problem.

  • PDF

Men's Role Conflicts in Dual-Earner Family (맞벌이 가족 남서의 역할갈등에 관한연구)

  • 김태현
    • Journal of Families and Better Life
    • /
    • v.16 no.1
    • /
    • pp.81-94
    • /
    • 1998
  • The purpose of this study is to examine men's role conflicts of dual-earner family based on man's role type. Man's role type is composed of man's sex role attitude and family-role performance and categorized in four types such as traditionalism type neo-traditionalism type equalitarianism type and inconsistancy type. The test analysis can be summarized as follows; First test analysis can be summarized as follows; role performance and man's role conflict as working hours is long wife's role requirement is high family-role conflict as working hours is long wife's role requirement is high family-role is not commit man's role conflict directly affected. In addition indirect affect through family-role performance shows that man's role conflict level is low as level of income is high level of income difference between man and wife is low child is younger and intent to modern sex-role attitude. Second looking into the difference role conflict to man's role type it shows that equalita ianism type's role conflict is low and man's role conflict in traditionalism and neo-traditonalism types is high.

  • PDF

A New Method for Assessing Dynamic Reliability for the Mid-loop Operation (원전의 부분충수운전에 대한 동적 신뢰도평가)

  • 제무성;박군철
    • Journal of the Korean Society of Safety
    • /
    • v.11 no.2
    • /
    • pp.52-59
    • /
    • 1996
  • This paper presents a new approach for assessing the dynamic reliability in a complex system such as a nuclear power plant. The method is applied to a dynamic analysis of the potential accident sequences which may occur during mid-loop operation. Mid-loop operation is defined as an operation to make RCS water level below the top of the flow area of the hot legs at the junction with the reactor vessel for repairs and maintenance of steam generators and reactor coolant pumps for a specific time. The Idea behind this approach consists of both the use of the concept of the performance achievement/requirement correlation and of a dynamic event tree generation method. The assessment of the system reliability depends on the determination of both the required performance distribution and the achieved performance distribution. The quantified correlation between requirement and achievement represents a comparison between two competing variables. It is demonstrated that this method is easily applicable and flexible in that it can be applied to any kind of dynamic reliability problem.

  • PDF

Quantized System Modeling and Performance Evaluation

  • Lee, Jong-Sik
    • Proceedings of the Korea Society for Simulation Conference
    • /
    • 2003.11a
    • /
    • pp.87-93
    • /
    • 2003
  • This paper reviews existing message-filtering schemes and presents a quantization-based message-filtering approach which reduces state update transmission and message traffic requirement. For a realization of the approach we develop a DEVS-based integrator which provides behavior and characteristic of the quantization-based approach. We take a spaceship and space traveling system as a case study to evaluate performance of the quantization-based approach. The approach is validated by DEVSJAVA simulations of the case study. The comparison of message traffic requirement between DTSS (Discrete Time System Specification)-based and DEVS-based systems apparently shows system performance improvement through the quantization-based approach.

  • PDF

Design and Performance Verification of a LWIR Zoom Camera for Drones

  • Kwang-Woo Park;Jonghwa Choi;Jian Kang
    • Current Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.354-361
    • /
    • 2023
  • We present the optical design and experimental verification of resolving performance of a 3× long wavelength infrared (LWIR) zoom camera for drones. The effective focal length of the system varies from 24.5 mm at the wide angle position to 75.1 mm at the telephoto position. The design specifications of the system were derived from ground resolved distance (GRD) to recognize 3 m × 6 m target at a distance of 1 km, at the telephoto position. To satisfy the system requirement, the aperture (f-number) of the system is taken as F/1.6 and the final modulation transfer function (MTF) should be higher than 0.1 (10%). The measured MTF in the laboratory was 0.127 (12.7%), exceeds the system requirement. Outdoor targets were used to verify the comprehensive performance of the system. The system resolved 4-bar targets corresponding to the spatial resolution at the distance of 1 km, 1.4 km and 2 km.

Distance Relaying Algorithm for Intertie Protection of a Wind Farm Considering the Fault Ride-through Requirement (Fault ride-through 요구를 고려한 풍력발전단지 연계선 보호 거리계전 알고리즘)

  • Kang, Yong-Cheol;Kang, Hae-Gweon;Zheng, Tai-Ying;Kim, Yeon-Hee;Lee, Young-Gui
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.6
    • /
    • pp.1053-1058
    • /
    • 2010
  • A large modern wind farm should satisfy the requirements for a grid and accomplish the optimization of the wind farm system. The wind farm intertie protection system should consider a Fault Ride-Through (FRT) requirement for more reliable protection. The wind farm should keep connected to the grid in the case of a grid fault whilst it should be isolated for an intertie fault. This paper proposes a distance relaying algorithm suitable for wind farm intertie protection considering the FRT requirement. The proposed algorithm estimates the impedance based on a differential equation method because the frequency of the voltage and current deviates the nominal frequency. The algorithm extends the reach of Zone 1 up to 100 % of the length of the intertie to implement the FRT requirement. To discriminate an intertie fault from a grid fault, the algorithm uses a voltage blocking scheme because the magnitude of the voltage at the relaying point for an intertie fault becomes less than that for a grid fault. The performance of the algorithm is verified using a PSCAD/EMTDC simulator under various fault conditions. The algorithm can discriminate successfully the intertie fault from grid fault and thus helps to implement the FRT requirement of a wind farm.