• Title/Summary/Keyword: performance point

Search Result 6,726, Processing Time 0.044 seconds

Comparative Study of Artificial-Intelligence-based Methods to Track the Global Maximum Power Point of a Photovoltaic Generation System (태양광 발전 시스템의 전역 최대 발전전력 추종을 위한 인공지능 기반 기법 비교 연구)

  • Lee, Chaeeun;Jang, Yohan;Choung, Seunghoon;Bae, Sungwoo
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.4
    • /
    • pp.297-304
    • /
    • 2022
  • This study compares the performance of artificial intelligence (AI)-based maximum power point tracking (MPPT) methods under partial shading conditions in a photovoltaic generation system. Although many studies on AI-based MPPT have been conducted, few studies comparing the tracking performance of various AI-based global MPPT methods seem to exist in the literature. Therefore, this study compares four representative AI-based global MPPT methods including fuzzy logic control (FLC), particle swarm optimization (PSO), grey wolf optimization (GWO), and genetic algorithm (GA). Each method is theoretically analyzed in detail and compared through simulation studies with MATLAB/Simulink under the same conditions. Based on the results of performance comparison, PSO, GWO, and GA successfully tracked the global maximum power point. In particular, the tracking speed of GA was the fastest among the investigated methods under the given conditions.

Active Vibration Control of a Beam using Direct Velocity Feedback (직접속도 피드백을 이용한 보의 능동진동제어)

  • 이영섭
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.587-592
    • /
    • 2004
  • Direct velocity feedback (DVFB) control is known that it offers an unconditional stability with very high performance when the control strategy is applied at a point collocated sensor and actuator pair, because the sensor-actuator pair has strictly positive real (SPR) property. In this paper, two types of collocated sensor-actuator pairs are considered for practical active vibration control of a structure. They are a point collocated sensor-actuator pair and a point sensor-distributed actuator pair. Both pairs with DVFB sho robust stability and performance. It is noted that the collocated point sensor-actuator ultimately acts as a 'skyhook' damper, but the point sensor-distributed actuator pair with DVFB acts as a 'skyhook' rotational dmaper pair.ational dmaper pair.

  • PDF

Failure Mode and Flexural Performance of RC Beams Strengthened with Different Bond Length of CFRP Strips (탄소섬유판으로 보강된 RC부재의 부착길이 변화에 따른 파괴모드 및 휨 보강성능)

  • Choi, Ki-Sun;You, Young-Chan;Kim, Keung-Hwan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.173-176
    • /
    • 2006
  • The one of the commonly reported failure mode of the RC beam strengthened with FRP was caused by the separation of the concrete cover, so called delamination. Therefore, ACI440 recommended that concrete cover delamination can be prevented in strengthened beams if bond length of FRP composite be exteneded over a point of cracking moment. In this study, the failure mode and the flexural performance of RC beam with different bond length of FRP are estimated. Each bonded length is calculated based on the point of cracking moment with addition or subtraction of specific length(=150mm). The results of this study show that mid-span debonding occurs in the specimen strengthened with CFRP strips which are bonded over the point of cracking moment, while concrete cover deliamination occurs at the termination point of CFRP in the specimen with less bonded length than the point of cracking moment region.

  • PDF

Method for Detection of Saturation of a Current Transformer (전류변성기의 포화 검출을 위한 알고리즘 개발)

  • Nam, Soon-Ryul;Choi, Joon-Ho;Kang, Sang-Hee;Min, Sang-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.5
    • /
    • pp.879-884
    • /
    • 2009
  • A Method for detection of saturation of a current transformer(CT) is proposed. The algorithm is initiated when the end point of a saturation period is detected. This detection is achieved by checking the time interval between the adjacent zero-crossing points of the second derivative of the secondary current. Once the end point of the saturation period is detected, the beginning point of the corresponding saturation period is determined by backward examination of the sum of the secondary current from the end point. The performance of the algorithm was evaluated for a-g faults on a 345 kV 100km overhead transmission line. The Electromagnetic Transient Program(EMTP) was used to generate fault current signals for different fault inception angles and different remanent fluxes. The performance evaluation shows that the proposed algorithm successfully detects the saturation period even in the presence of a remanent flux.

Active Vibration Control of a Beam Using Direct Velocity Feedback (보의 능동진동제어을 통한 직접속도 피드백의 적용성 연구)

  • 이영섭
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.14 no.7
    • /
    • pp.619-625
    • /
    • 2004
  • Direct velocity feedback (DVFB) control is known that it offers an unconditional stability with very high performance when the control strategy is applied at a point collocated sensor and actuator pair. because the sensor-actuator pair has strictly positive real (SPR) property In this paper, two types of collocated sensor-actuator pairs are considered for practical active vibration control of a structure. They are a Point collocated sensor-actuator pair and a point sensor-distributed actuator pair. Both pairs with DVFB show robust stability and performance. It is noted that the collocated point sensor-actuator ultimately acts as a “skyhook” damper, hut the point sensor-distributed actuator pair with DVFB acts as a “skyhook” rotational damper pair.

Measuring System for Impact Point of Arrow using Mamdani Fuzzy Inference System (Mamdani 퍼지추론을 이용한 화살의 탄착점 측정 시스템)

  • Yu, Jung-Won;Lee, Han-Soo;Jeong, Yeong-Sang;Kim, Sung-Shin
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.521-526
    • /
    • 2012
  • The performance of arrow from a manufacturing process depends on arrow's trajectory(archer's paradox) and intensity of an impact points. Especially, when conducting a shooting experiment over and over in the same experiment condition, the intensity of impact point is an objective standard to judge the performance of the arrow. However, the analysis method for the impact point is not enough, a previous research of the arrow's performance has been focused on a skill to optimize a manufacturing variables(feathers of an arrow, barb of an arrow, arrow's shaft, weight, external diameter, spine). In this paper, We propose measurement system of arrow's impact point with Mamdani fuzzy inference system and similarity of polygon for automation of impact point's measurement. Measuring the impact point data of the arrow moving with a high speed(approximately 275km/h) by using line laser and photo diode array, then the measured data are mapped to arrow's impact point with fuzzy inference and similarity of polygon.

Impact of Call Setup Time on UPT Performance Based on AIN Platform

  • Baik, In-Kywan;Jo, Jun-Mo;Kim, Sung-Un;Jung, Sin-Il
    • Journal of Korea Multimedia Society
    • /
    • v.1 no.2
    • /
    • pp.249-255
    • /
    • 1998
  • This paper analyzes the impact of Call Setup Time on UPT performance based on the AIN platform. Call Setup Time is used as the performance parameter. In implementing UPT based on the AIN platform, the geographical location of VLR affects network performance. In order to find an optimum location of VLR among three different types of structures, i.e. VLR is located close to Service Switching Point and Cell Site Controller and located at Service Control Point, each Call Setup Time on proposed time delay model is calculated and compared. Network performance is analyzed by changing the number of STP in No.7 signaling network in UPT and the utilization ratio, $\rho$, for SSP, STP and SCP.

  • PDF

Computational Performance Prediction of Main Coolant Pump for the Integral Reactor SMART (일체형원자로 SMART 냉각재 순환펌프의 전산성능예측)

  • Kim M. H;Lee J. S;Park J. S;Kim J. I;Kim K. K
    • Journal of computational fluids engineering
    • /
    • v.8 no.3
    • /
    • pp.32-40
    • /
    • 2003
  • CFD analyses of the three-dimensional turbulent flow in the impeller and diffuser of an axial flow pump including suction and discharge parts are presented and compared with experimental data. The purpose of the current study is to validate the CFD method for the performance analysis of the main coolant pump for SMART and to investigate the effect of suction and discharge shapes on the pump performance. To generate a performance curve, not only the design point but also the off-design points were computed. The results were compared with available experimental data in terms of head generated. At the design point, the analysis accurately predicts the experimental head value. In the range of the higher flow rates, the results are also in very good agreement with the experimental data, in magnitude but also in terms of slope of variation. For lower flow rates, the results shows that the analysis considering the suction and discharge well describe the typical S-shape performance curve of the axial pump.

A Study on Synthesis and Characteristics of The Optimum Rolling Bearing Greases (최적 베어링 윤활 그리이스의 합성과 특성연구)

  • Kim Sang-Keun;Park Chang-Nam;Han Jong-Dae;Son Gwan-Su
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.129-138
    • /
    • 2003
  • Rolling bearings are classified one of the most important machine elements. The various function of bearings are greatly influenced by grease, and higher performance of rolling bearing greases is required in improve bearing lubrication. Three urea/ether oil greases with identical composition were synthesized to compare the performance of these greases according to the thickener content of grease. The typical grease physical properties were investigated. And life test of these greases was conducted by FE-9 grease life tester. The characteristics of the greases before and after life test were investigated using FT-IR, microscope, OIT and TAN meter. Large differences in the grease performance depending on the content of the thickener were observed. The grease with higher content of the hickener showed higher performance such as long life time and low TAN value. After preliminary test, twelve greases were synthesized and evaluated the performance of dropping point and OIT, then optimized two greases were selected by SSRED (Six Sigma Robust Engineering Design) using dropping point and OIT data. Characteristics of the optimized two greases were on the same level with estimated value. The optimized grease by means of OIT value showed longer grease life in comparison with optimized grease by dropping point. However two greases showed higher performance than typical urea/ether oil.

  • PDF

A New Consolidation Algorithm for Point-to-Multipoint ABR Flow Control in ATM Networks (ATM망에서 점대 다중점 ABR 흐름 제어를 위한 새로운 통합 알고리즘)

  • 김동호;조유제안윤영
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.134-137
    • /
    • 1998
  • In this paper, we propose a new consolidation algorithm for point-to-multipoint ABR flow control and compare the performance of the proposed algorithms with that of an existing consolidation algorithm. We first investigate problems of the existing algorithm in consolidating backward RM cells and propose two new consolidation algorithms to resolve these problems. Also, we investigate the performance of the proposed algorithms by simulation. As results, we show that the proposed algorithms exhibit a better performance than the existing algorithm in terms of ACR, queue length, utilization, and fairness.

  • PDF