지능형 보호기기 적용 태양광 인버터 성능시험 (Performance Test of an Integrated Electronic Protection Device Based Photovoltaic Inverter)

  • 김응상;김슬기;전진홍;안종보
    • 전기학회논문지
    • /
    • 제56권10호
    • /
    • pp.1744-1750
    • /
    • 2007
  • This paper addresses grid interconnection tests of a 3kW transformer-less photovoltaic (PV) inverter to verify the effectiveness of the PV inverter and promote its wide use. The 3kW transformer-less PV inverter, which was equipped with intelligent protection and control system, was manufactured. A hardware test bed was constructed for performance tests of the PV inverter. Control performance and grid protection tests were carried out using the test bed. Test results verify the performance of the power control and grid protection functions of the developed transformer-less PV inverter.

한국형 전술데이터링크(Link-K)의 무선통신 시험환경 구성 및 다중접속 프로토콜 성능분석 (The Implementation of Wireless Communication Test Environment for the Link-K System and Performance Analysis of Multiple Access Protocols)

  • 권구형
    • 한국군사과학기술학회지
    • /
    • 제12권2호
    • /
    • pp.170-174
    • /
    • 2009
  • This paper describes the wireless communication test environment for the Link-K system and shows the performance analysis of multiple access protocols. The test environment consists of data generator, modem, radio sets, attenuators, and antennas. In case of both CSMA and Roll-Call protocols, throughput performance and delay are measured. And test results are analyzed. The test results would be used for communication performance analysis and network design of Link-K system.

고속철도 차량성능기준(안) 작성에 관한 연구 (A Study on Performance Test Standards for High-speed Rolling-stock System)

  • 왕종배;박찬우;곽상록
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.569-574
    • /
    • 2005
  • In this study, test standards were developed for performance verification of the high speed(350km/h) rolling-stock. The performance test system consist of three type tests; the component test for core item, the completed car test for combined function & operation and the trial driving test for compatibility & interrelationship with infrastructure.

  • PDF

안전밸브 성능점검 자료 분석을 통한 운전 중 점검방법 도입의 필요성 고찰 (The necessity of Introducing the In-service Test based on Analysis of Performance Test Result of Pressure Safety Valve)

  • 장유리;김정환;길성희;곽영환
    • 한국가스학회지
    • /
    • 제21권6호
    • /
    • pp.15-22
    • /
    • 2017
  • 안전밸브는 높은 압력을 사용하고 있는 공장들의 안전을 확보하기 위한 최후의 수단이다. 안전밸브의 고장은 대형사고로 이어지므로, 주기적으로 작동성능을 점검하도록 법으로 정해져 있다. 현재 안전밸브의 작동성능을 확인하기 위해서 직접검사방법을 이용하고 있으나 이는 검사 사각지대의 유무, 비용 및 효율적인 손실 등으로 인해 운전 중 검사 방법의 개발이 요구 되고 있는 실정이다. 본 연구에서는 안전밸브 성능검사 결과자료를 분석하여 국가 산업단지의 불안전한 안전밸브 상태를 살펴봄으로써 현재 운용 중인 직접검사법만으로는 안전성의 확보에 한계가 있음을 확인했다. 이에 따라 직접검사법의 한계를 극복하기 위하여 운전 중 검사법 도입의 필요성을 검토하고, 필수 기반 시설에의 적용을 의무화 하는 등 공정 운전 중에도 안전밸브의 검사가 가능한 방법의 개발과 관련 제도의 변화가 필요할 것으로 판단된다.

착상을 수반한 핀-관 열교환기의 성능평가계수에 관한 연구 (The Study of Performance Evaluation Coefficient of Fin-and-Tube Heat Exchangers with Frosting)

  • 최봉준;황준현;신종민
    • 설비공학논문집
    • /
    • 제15권2호
    • /
    • pp.132-136
    • /
    • 2003
  • For the study of performance evaluation on different shape heat exchangers that have the same energy consumption in a refrigerator, we make performance evaluation coefficient (PEC) which can distinguish performance of different shape heat exchangers. The results were reported in order to compare with for the dry frosting and wet frosting test as various definition of PECs. Results showed that PEC of dry frosting test is higher than that of wet frosting test because attached water droplet increases pressure drop of air-side then this decreases performance of heat exchanger.

마이크로 가스터빈 엔진 성능실험 연구 (Experimental Study of the Micro Gas Turbine Engine Performance Test)

  • 김승재;최성만;이동호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.587-590
    • /
    • 2017
  • 마이크로 가스터빈엔진의 성능 실험연구를 수행하였다. 성능측정을 위하여 마이크로엔진에 적합한 시험장치를 구축하였으며, Olympus HP Engine을 이용하여 성능측정을 수행하였다. 엔진흡입 공기유량, 추력, 연료소모율, 각 구성품 입구에서의 공기 및 가스온도를 측정하였다. 측정된 결과부터 마이크로 가스터빈 엔진의 성능특성을 보다 잘 이해할 수 있었다.

  • PDF

RTDS 시험모듈을 이용한 태양광 인버터의 성능시험에 관한 연구 (A Study on Performance Test of a Photovoltaic System Inverter using Real Time Digital Simulator (RTDS))

  • 김응상;김슬기;전진홍;안종보
    • 전기학회논문지
    • /
    • 제56권2호
    • /
    • pp.325-333
    • /
    • 2007
  • A PV system inverter test module using RTDS was developed and performance test of a commercial PV inverter was carried out. The developed module consists of one RTDS hardware rack, RTDS software models representing PV array and simple distribution system, and two power amplifiers that was specifically designed for generating power corresponding to signals from RTDS. Performance test results verified effectiveness and reliability of the test module. It is expected that the developed test module may help PV inverter manufacturers improve ana test their systems in the developing stage.

균등 및 비균등 배열 헬리콥터 반토오크 시스템 성능 및 소음특성 (Sound Characteristics and Performance of Even and Uneven Blade Spacing Helicopter Anti-Torque System)

  • 송근웅;정기훈;강희정;김승범;이제동
    • 한국소음진동공학회논문집
    • /
    • 제16권8호
    • /
    • pp.857-863
    • /
    • 2006
  • This paper described the performance test and sound characteristics of helicopter 'Tail-Fan' anti-torque system. In this research, Korea Aerospace Research Institute(KARI) developed 'Tail-Fan' anti-torque system for a helicopter and carried out performance and sound capturing tests of even and uneven tail fans. The performance test is carried out and the noise signals which are generated during the test are saved with microphones at the same time. The performance test's results meet the design requirements. Tone-corrected perceived noise level is reduced by replacing the even product with the uneven one.

MMC 기반 STATCOM 용 밸브의 성능시험 장치를 위한 새로운 토폴로지 (New Topology for Valve Performance Test Equipment of MMC based STATCOM)

  • 배종우;정재헌;노의철;정용호;백승택;이진희;김영우
    • 전력전자학회논문지
    • /
    • 제22권1호
    • /
    • pp.82-88
    • /
    • 2017
  • This study proposes a new topology for the performance test of a valve consisting of a modular multilevel converter (MMC)-based static synchronous compensator (STATCOM). The conventional valve performance test equipment requires high-voltage AC source of several kV rating because the number of submodules to be tested in a valve should be at least six or eight. However, the power source of the proposed scheme is DC and not AC source. The DC power source voltage range of the proposed test circuit is from several volts to several tens of volts. Therefore, the size and cost for the performance test equipment can be reduced considerably compared with the conventional method. The proposed scheme satisfies the requirements of the IEC 62927 standard. Simulations are conducted for a valve of 50[MVA] MMC-based STATCOM. Experimental results with a scale-downed setup show the validity of the proposed performance test topology.

PV모듈의 I-V특성 시험을 위한 Solar Simulator의 측정불확도 요인 분석 (Analysis of Solar Simulator's Uncertainty Factor for Photovoltaic Module's I-V curve test)

  • 강기환;박지홍;김경수;유권종;안형근;한득영
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 하계학술대회 논문집 Vol.7
    • /
    • pp.5-7
    • /
    • 2006
  • In this paper, we analyzed the elements of measurement uncertainty on electrical performance test which are the most important things in photovoltaic module performance test. Repeating the performance test by 6 men, the measurement uncertainty could be calculated. In this experiment, Solar Simulator (A-Class pulse type) used for domestic certificate test of PV module is Pasan IIIb (Balval, Switzerland). The possible elements of the measurement uncertain that could effect electrical performance test of PV module are reference cell, spectrum correction, error from measurement repetition, test condition, stability and uniformity of artificial solar simulator. To find the measurement uncertainty, 6 men repeated the test by 10 times. And the results were that numerical average value was 124.44W and measurement uncertainty was $124.44W{\pm}0.75W$ with 95% confidence level for 125W PV module.

  • PDF