• Title/Summary/Keyword: performance design

Search Result 28,874, Processing Time 0.067 seconds

A Study of Health Condion and Shift Service of the Nurse in (종합병원 간호사의 교대근무와 건강상태에 관한 연구)

  • Kim, Soon-Ok
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.3 no.1
    • /
    • pp.119-133
    • /
    • 1997
  • Continuing shift service of clinical nurses can be not only the cause of occupational dissatisfaction by being connected with the change of circadian rhythm and the burden of duties to be applicable to such changes. But also of inviting the lowering of nursing quality by being affected to the resignation of the nurses as the threat to the health of the nurses. This study has selected 500 nurses at random under non-probability sampling who have been serving by shift in 7 general hospitals which have over 400 sickbeds for the purpose of cross-sectional survey design from Sep. 7 through 20, 1996. Standardized modification of the CMI has been used which was designed for Koreans with Cornell Medical Index developed by Broadman and his fellow workers as the study device. The structure of the device was composed of 35 questions on physical appeal(Chronbach's ${\alpha}=8507$) and 22 questions of mental appeal(Cronbach's ${\alpha}=.8166$ totalling 57 questions. The collected data has been computerrized by using SPSS. General character, present symptom, perceived symptom and others are sought by practical number and percentage, and the health condition comparison followed by general characters was conducted by t-test and ANOVA. The post test was by Duncan's test by the level of p<.05. 1) The items of the answer that they have the physical symptom presently by 50% or over of the nurses were as "Do you often have spells of severe dizziness", "Are your eyes often red or inflamed", "Does press or pain in the head often make like miserable", "Are your ankles often badly swollen", "Do pains in the back make it hard for you to keep up with your work". 2) The items of the answer by over 50% of the nurses as the mental symptom at present were "do you fell bad when criticized?", "Do you get angry when everything is against your will?", "do you get angry when ordered to do this and that?", "do you feel uneasy by such a trifle thing?", "do you tremble or are you freightened by sudden sound?". The mental and physical symptoms which have appeared presently in connection with the shift service have been agreed with each other. But the physical condition has been worse than the mental one. 3) In the physical health conditions followed by demosociological character, there were the significant differences by sex, religion and place of residence(p<.05), and in the mental health conditions, there were the significant differences by age, marital status, residence place and the required time for attending hospital(p<.05). 4) There was significant difference by the degree of satisfaction about the duty in both the physical and mental health conditions. In short, the higher the degree of duty satisfaction, the better the health conditions. 5) There were the significant difference according to the times of night duty and whether they take the drug or not or the kinds of the drugs in the physical health conditions related with the characters of night shift. Mental health conditions in the night shift case showed significant differences according to their taking drug or not or the kinds of the drugs(p<.05). I can confirm that the nurses have been affected continuously by the shift service mentally and physically. The maintenance of the physical and mental health of the nurses and its promotion are very important problem to guarantee the quality nursing in the performance of the nursing service continuously and effectively, so the hospital should make every effort to improve the duty conditions by finding out the causes affecting to their health. In the nursing management viewpoint, I think that elevating the satisfaction degree about the duty would be a great help to the promotion of physical and mental health conditions. But what is most important is that the nurses themselves should take care of themselves in maintaining the good conditions in their service in the hospital.

  • PDF

Effects of high energy diet on growth performance, carcass characteristics, and blood constituents of final fattening Hanwoo steers (고에너지 사양이 비육후기 거세한우의 성장, 도체, 및 혈액성상에 미치는 영향)

  • Chung, Ki Yong;Chang, Sun Sik;Lee, Eun Mi;Kim, Hyun Ju;Park, Bo Hye;Kwon, Eung Gi
    • Korean Journal of Agricultural Science
    • /
    • v.42 no.3
    • /
    • pp.261-268
    • /
    • 2015
  • The aim of this study was to examine the effects of high energy diet on growth 26mon, 28mon, and 30mon in Hanwoo at different ages. High energy diet required not only an amount of concentrate on days of fattening periods but also induced cost for the management. We hypothesized that high energy diet was able to reduce a fattening period to reach a certain quality grade. A $2{\times}3$ factorial arrangement (High energy, control vs 26, 28, 30month endpoints) in a completely random design was used to feed 48 Hanwoo steers. Four steers were fed in same pen and 12 pens were used for treatment. Blood was drawn from each steers on every other months during early, middle, and final fattening periods. Over all ADG and feed efficiency were not different between high energy and control diet (P > 0.05). Dry matter intake was induced 30 mo-old early and final fattening periods at high energy diet. Serum glucose concentration were increased (P < 0.05) at 30 and 26month old steers. Marbling scores were greater at 30 month old than 26 and 28 month old Hanwoo steers. Carcass weight of Hanwoo steers were greater at 30 mon-old groups than other groups. These result indicated that high energy diet (+3% TDN) and slaughter endpoint collectively contribute to the observed quality grade compositional differences among three final fattening periods of Hanwoo steers.

A Study on Laboratory Treatment of Metalworking Wastewater Using Ultrafiltration Membrane System and Its Field Application (한외여과막시스템을 이용한 금속가공폐수의 실험실적 처리 및 현장 적용 연구)

  • Bae, Jae Heum;Hwang, In-Gook;Jeon, Sung Duk
    • Korean Chemical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.487-494
    • /
    • 2005
  • Nowadays a large amount of wastewater containing metal working fluids and cleaning agents is generated during the cleaning process of parts working in various industries of automobile, machine and metal, and electronics etc. In this study, aqueous or semi-aqueous cleaning wastewater contaminated with soluble or nonsoluble oils was treated using ultrafiltration system. And the membrane permeability flux and performance of oil-water separation (or COD removal efficiency) of the ultrafiltration system employing PAN as its membrane material were measured at various operating conditions with change of membrane pore sizes and soil concentrations of wastewater and examined their suitability for wastewater treatment contaminated with soluble or insoluble oil. As a result, in case of wastewater contaminated with soluble oil and aqueous or semi-aqueous cleaning agent, the membrane permeability increased rapidly even though COD removal efficiency was almost constant as 90 or 95% as the membrane pore size increased from 10 kDa to 100 kDa. However, in case of the wastewater contaminated with nonsoluble oil and aqueous or semi-aqueous cleaning agent, as the membrane pore size increased from 10 kDa to 100 kDa and the soil concentration of wastewater increased, the membrane permeability was reduced rapidly while COD removal efficiency was almost constant. These phenomena explain that since the membrane material is hydrophilic PAN material, it blocks nonsoluble oil and reduces membrane permeability. Thus, it can be concluded that the aqueous or semi-aqueous cleaning solution contaminated with soluble oil can be treated by ultrafiltration system with the membrane of PAN material and its pore size of 100 kDa. Based on these basic experimental results, a pilot plant facility of ultrafiltration system with PAN material and 100 kDa pore size was designed, installed and operated in order to treat and recycle alkaline cleaning solution contaminated with deep drawing oil. As a result of its field application, the ultrafiltration system was able to separate aqueous cleaning solution and soluble oil effectively, and recycle them. Further more, it can increase life span of aqueous cleaning solution 12 times compared with the previous process.

Theoretical Study on Optimal Conditions for Absorbent Regeneration in CO2 Absorption Process (이산화탄소 흡수 공정에서 흡수액 최적 재생 조건에 대한 이론적 고찰)

  • Park, Sungyoul
    • Korean Chemical Engineering Research
    • /
    • v.50 no.6
    • /
    • pp.1002-1007
    • /
    • 2012
  • The considerable portion of energy demand has been satisfied by the combustion of fossil fuel and the consequent $CO_2$ emission was considered as a main cause of global warming. As a technology option for $CO_2$ emission mitigation, absorption process has been used in $CO_2$ capture from large scale emission sources. To set up optimal operating parameters in $CO_2$ absorption and solvent regeneration units are important for the better performance of the whole $CO_2$ absorption plant. Optimal operating parameters are usually selected through a lot of actual operation data. However theoretical approach are also useful because the arbitrary change of process parameters often limited for the stability of process operation. In this paper, a theoretical approach based on vapor-liquid equilibrium was proposed to estimate optimal operating conditions of $CO_2$ absorption process. Two $CO_2$ absorption processes using 12 wt% aqueous $NH_3$ solution and 20 wt% aqueous MEA solution were investigated in this theoretical estimation of optimal operating conditions. The results showed that $CO_2$ loading of rich absorbent should be kept below 0.4 in case of 12 wt% aqueous $NH_3$ solution for $CO_2$ absorption but there was no limitation of $CO_2$ loading in case of 20 wt% aqueous MEA solution for $CO_2$ absorption. The optimal regeneration temperature was determined by theoretical approach based on $CO_2$ loadings of rich and lean absorbent, which determined to satisfy the amount of absorbed $CO_2$. The amount of heating medium at optimal regeneration temperature is also determined to meet the difference of $CO_2$ loading between rich and lean absorbent. It could be confirmed that the theoretical approach, which accurately estimate the optimal regeneration conditions of lab scale $CO_2$ absorption using 12 wt% aqueous $NH_3$ solution could estimate those of 20 wt% aqueous MEA solution and could be used for the design and operation of $CO_2$ absorption process using chemical absorbent.

Improved Electrochemical Performance and Minimized Residual Li on LiNi0.6Co0.2Mn0.2O2 Active Material Using KCl (KCl을 사용한 LiNi0.6Co0.2Mn0.2O2계 양극활물질의 잔류리튬 저감 및 전기화학특성 개선)

  • Yoo, Gi-Won;Shin, Mi-Ra;Shin, Tae-Myung;Hong, Tae-Whan;Kim, Hong-kyeong
    • Journal of the Korean Electrochemical Society
    • /
    • v.20 no.1
    • /
    • pp.7-12
    • /
    • 2017
  • Using a precursor of $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$ as a starting material, a surface-modified cathode material was obtained by coating with KCl, where the added KCl reduces residual Li compounds such as $Li_2CO_3$ and LiOH, on the surface. The resulting electrochemical properties were investigated. The amounts of $Li_2CO_3$ and LiOH decreased from 8,464 ppm to 1,639 ppm and from 8,088 ppm to 6,287 ppm, respectively, with 1 wt% KCl added $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$ that had been calcined at $800^{\circ}C$. X-ray diffraction results revealed that 1 wt% of KCl added $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$ did not affect the parent structure but enhanced the development of hexagonal crystallites. Additionally, the charge transfer resistance ($R_{ct}$) decreased dramatically from $225{\Omega}$ to $99{\Omega}$, and the discharge capacity increased to 182.73mAh/g. Using atomic force microscopy, we observed that the surface area decreased by half because of the exothermic heat released by the Li residues. The reduced surface area protects the cathode material from reacting with the electrolyte and hinders the development of a solid electrolyte interphase (SEI) film on the surface of the oxide particles. Finally, we found that the introduction of KCl into $LiNi_{0.6}Co_{0.2}Mn_{0.2}O_2$ is a very effective method of enhancing the electrochemical properties of this active material by reducing the residual Li. To the best of our knowledge, this report is the first to demonstrate this phenomenon.

Effects of Dietary Probiotics on Feed Intakes, Nutrient Digestibility and Nitrogen Retention in Korean Black Goats Fed Two Diets Differing in Forage to Concentrate Ratios (사료 내 조농비율에 따른 생균제의 첨가가 흑염소의 사료섭취량, 영양소 소화율 및 질소축적에 미치는 영향)

  • HwangBo, Soon;Jo, Ik-Hwan;Song, Ki-Jun;Lee, Sung-Hoon
    • Korean Journal of Organic Agriculture
    • /
    • v.15 no.2
    • /
    • pp.195-205
    • /
    • 2007
  • This study was conducted to determine effects of probiotics on performance, nutrient digestibility and nitrogen retention in Korean black goats fed two diets differing in forage to concentrate (F:C) ratio (30:70 and 70:30), for the establishment of their more efficient feeding management system. The probiotics employed in this trial were mixtures of different microbial species, which consisted of Lactobacillus casei, Bacillus subtilis, Saccharomyces cerevisiae, Aspergillus oryzae and Streptomyces griseus. Additional levels of probiotics to each F:C ratio (70:30 or 30:70) were 0 and 0.2%, respectively. Thus, twelve Korean black male goats were allotted to treatments in four groups of three goats per treatment and then they were housed in individual metabolism cages with a randomized complete block design for 21 days. Dry matter (DM) intakes were not affected by dietary F:C ratio and probiotics. Digestible DM amounts were significantly (p<0.05) decreased with increasing levels of dietary forage, but they were not affected by probiotics addition. Dry matter intakes per metabolic body weight and their ratio per body weight had a similar trend to DM intakes with no significant difference by F:C ratio and probiotics addition. The nutrient digestibility was significantly (p<0.05) increased with decreasing levels of forage in the diet, but it was not affected by probiotics addition. Urinary nitrogen loss was significantly (p<0.05) decreased with decreasing levels of dietary forage, but there was no significant difference between probiotics-supplemented and unsupplemented groups within the same F:C ratio. On the contrary, nitrogen retention was decreased with increasing levels of dietary forage, and probiotics supplementation to two diets differing in F:C ratio showed slightly increasing trends in the nitrogen retention. From the above results, probiotics supplementation to two diets differing in F:C ratio did not have the significant influence on feed intakes, nutrient digestibility and nitrogen retention. Consequently, these parameters of Korean black goats were dominated rather by F:C ratio than by dietary probiotics.

  • PDF

Methane Fermentation of Facultative Pond in Pond System for Ecological Treatment and Recycling of Livestock Wastewater (축산폐수 처리 및 재활용을 위한 조건성연못의 메탄발효)

  • Yang, Hong-Mo
    • Korean Journal of Environmental Agriculture
    • /
    • v.19 no.2
    • /
    • pp.171-176
    • /
    • 2000
  • A wastewater treatment pond system was developed for treatment and recycling of dairy cattle excreta of $5\;m^1$ per day. The wastes were diluted by the water used for clearing stalls. The system was composed of three ponds in series. A submerged gas collector for the recovery of methane was installed at the bottom of secondary pond with water depth of 2.4m. This paper deals mainly with performance of methane fermentation of secondary pond which is faclutative one. The average $BOD_5$, SS, TN, and TP concentrations of influent into secondary pond were 49.1, 53.4, 48.6, and 5.3 mg/l, and those of effluent from it were 27.9, 45.7, 30.8, 3.2 mg/l respectively. Methane fermentation of 2.4-meter-deep secondary pond bottom was well established at $16^{\circ}C$ and gas garnered from the collector at that temperature was 80% methane. Literature on methane fermentation of wastewater treatment ponds shows that methane bacteria grow well around $24^{\circ}C$, the rate of daily accumulation and decomposition of sludge is approximately equal at $19^{\circ}C$, and activities of methanogenic bacteria are ceased below $14^{\circ}C$. The good methane fermentation of the pond bottom around $16^{\circ}C$, about $3^{\circ}C$ lower than $19^{\circ}C$, results from temperature stability, anaerobic condition, and neutral pH of the bottom sludge layer. It is recommended that the depth of pond water could be 2.4m. Gas from the collector during active methane fermentation was almost 83% methane, less than 17% nitrogen. Carbon dioxide was less than 1% of the gas, which indicates that carbon dioxide produced in bottom sludges was dissolved in the overlaying water column. Thus a purified methane can be collected and used as energy source. Sludge accumulation on the pond bottom for a nine month period was 1.3cm and annual sludge depth can be estimated to be 1.7cm. Design of additional pond depth of 0.3m can lead to 15 - 20 year sludge removal.

  • PDF

Position Uncertainty due to Multi-scattering in the Scintillator Array of Dual Collimation Camera (복합 집속 카메라의 섬광체배열에서 다중산란에 의한 위치 불확실성)

  • Lee, Won-Ho
    • Journal of radiological science and technology
    • /
    • v.31 no.3
    • /
    • pp.287-292
    • /
    • 2008
  • Position information of radiation interactions in detection material is essential to reconstruct a radiation source image. With most position sensing techniques, the position information of a single interaction inside the detectors can be precisely obtained. Each interaction position of multi-scattering inside scintillators, however, can not be individually measured and only the average of the scattering positions can be obtained, which causes the uncertainty in the measured interaction position. In this paper, the position uncertainties due to the multi-scattering were calculated by Monte Carlo simulation. The simulation model was a 50 by 50 by 5 mm $LaCl_3$(Ce) scintillator(pixel size is 2 by 2 by 5mm) which was utilized for the dual collimation camera. The dual collimation camera uses the information from both photoelectric effect and Compton scattering, and therefore, position uncertainties for both partial and full energy deposition of radiation interactions are calculated. In the case of partial energy deposition(PED), the standard deviations of positions are less than $1{\sim}2mm$, which means the uncertainty caused by multi-scattering is not significant. Because the effect of the multi-scattering with PED is insignificant, the multi-scattering has little effect on the performance of Compton imaging of dual collimation camera. In the case of full energy deposition(FED), however, the standard deviation of the positions is about twice that of the pixel size of the 1stdetector, except for 122keV incident radiations. Therefore, the standard deviations caused by multi-scatterings should be considered in the design of the coded mask of the dual collimation camera to avoid artifact on the reconstructed image. The position uncertainties of the FEDs are much larger than those of the PEDs for all radiation energies and the ratio of PEDs to FEDs increases when the incident radiation energy increases. The position uncertainties of both PEDs and FEDs are dependent on the incident radiation energy.

  • PDF

Measurement of competency through self study in basic nursing lab. practice focused on cleansing enema (기본간호학 실습에 있어 자가학습을 통한 능숙도 측정 - 배변관장을 중심으로 -)

  • Ko Il-Sun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.6 no.3
    • /
    • pp.532-543
    • /
    • 1999
  • This study was conducted to provide the basic data necessary for the improvement of the teaching method for basic nursing practice as well as the effectiveness of the practice by examining the students' competency in cleansing enema after doing the self study instead of the traditional education. To examine the competency in cleansing enema after the self study, this study is an one group pretest-posttest design that subjects did the enema practice through the self study. The subjects were 89 sophomore students at Y University. College of Nursing. In basic nursing lab practice class, cleansing enema self study module was given to the students which was developed by the researcher based on the literature review and asked them to finish doing the pre study and checking the self study evaluation criteria after reading the goal, learning activities and theoretical guideline. After watching the video tape, students practiced the process in the module by themselves. For the competency in cleansing enema. repeated autonomous practices were done during the open lab other than the regular class. Whenever the practice was done, the frequency and time were measure and documented. When the student felt confident through repeated practices, the competency was evaluated by the researcher and two assistants based on the evaluation criteria. And the process was repeated till the student could perform all the items on evaluation criteria completely. The data were collected for 42 days from Oct. 15 to Nov. 26 in 1996. Collected data were analyzed by frequency, percentage, Pearson correlation coefficient and variance analysis. The results are summarized as follows : 1. 43.2% of the students were favorable to nursing and 63.6% like lecture, but 71.6% like practice. So they were more interested in practice than in lecture. 2. 62.3% of the students scored high in written test, 97.8% scored high in practice. So the practice score was better. 3. The frequency of repeated practice to pass the test ranged from 1 to 4 and the average is 2.2. 4. The average time needed in preparation and the performance was nearly the same regardless of the frequency. It took 5 to 38 minutes for those who passed the test after practicing once and the average was 16 minutes. 5 to 60 minutes were taken for those who practiced twice to pass the test and the average was 21 minutes. Those who passed the test after three practices needed 8 to 30 minutes and the average was 15 minutes, which was similar to the time that the students who passed the test for the first trial. Only one student passed the test after 4 practices and it took 10 minutes. 5. 64% of the students agreed that the context and the content of the module were appropriate for the self study and 68.2% were satisfied. And 71.9% said that the module helped them to practice the enema self study 6. Though only 42% of the students were satisfied with the video. 50.6% said that it was helpful for the self study. 7. 52.3% of the students were satisfied with the self study method, and 86.6% obtained self-confidence when performing the enema. 8. The lower the student's practice score was, the more practices were needed for them to pass the test(r=-.213, P<.05). As a result, for performing the enema practice competently, two or more practice opportunities were needed to be given. And it is possible to obtain the less complex nursing skills through the self study, when enough learning resources and assistance such as learning guidance or video tapes are provided. Based on this study. I want to suggest that. 1. There must be college policy that can support the new method instead of the traditional learning method for the students to attain the proficiency in basic nursing skills. 2. The assistant materials should be developed as soon as possible to promote the self study of basic nursing skills.

  • PDF

A Study on The RFID/WSN Integrated system for Ubiquitous Computing Environment (유비쿼터스 컴퓨팅 환경을 위한 RFID/WSN 통합 관리 시스템에 관한 연구)

  • Park, Yong-Min;Lee, Jun-Hyuk
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.1
    • /
    • pp.31-46
    • /
    • 2012
  • The most critical technology to implement ubiquitous health care is Ubiquitous Sensor Network (USN) technology which makes use of various sensor technologies, processor integration technology, and wireless network technology-Radio Frequency Identification (RFID) and Wireless Sensor Network (WSN)-to easily gather and monitor actual physical environment information from a remote site. With the feature, the USN technology can make the information technology of the existing virtual space expanded to actual environments. However, although the RFID and the WSN have technical similarities and mutual effects, they have been recognized to be studied separately, and sufficient studies have not been conducted on the technical integration of the RFID and the WSN. Therefore, EPCglobal which realized the issue proposed the EPC Sensor Network to efficiently integrate and interoperate the RFID and WSN technologies based on the international standard EPCglobal network. The proposed EPC Sensor Network technology uses the Complex Event Processing method in the middleware to integrate data occurring through the RFID and the WSN in a single environment and to interoperate the events based on the EPCglobal network. However, as the EPC Sensor Network technology continuously performs its operation even in the case that the minimum conditions are not to be met to find complex events in the middleware, its operation cost rises. Moreover, since the technology is based on the EPCglobal network, it can neither perform its operation only for the sake of sensor data, nor connect or interoperate with each information system in which the most important information in the ubiquitous computing environment is saved. Therefore, to address the problems of the existing system, we proposed the design and implementation of USN integration management system. For this, we first proposed an integration system that manages RFID and WSN data based on Session Initiation Protocol (SIP). Secondly, we defined the minimum conditions of the complex events to detect unnecessary complex events in the middleware, and proposed an algorithm that can extract complex events only when the minimum conditions are to be met. To evaluate the performance of the proposed methods we implemented SIP-based integration management system.