Reconstruction of Greater Trochanteric defect using Lumbar Artery Perforator Free Flap - A Case Report - (요추부 천공지 유리피판을 이용한 대전자부 결손의 재건 - 증례보고 -)

  • Heo, Chan-Yeong;Baek, Rong-Min;Minn, Kyung-Won;Eun, Seok-Chan
    • Archives of Reconstructive Microsurgery
    • /
    • v.16 no.1
    • /
    • pp.48-51
    • /
    • 2007
  • There could be several methods for trochanteric reconstruction including local flap, pedicled perforator flaps, free flap, etc. We performed greater trochanteric reconstruction with lumbar artery perforator free flap in some aberrant method. So we report this experience with review of literatures. A 42-year-old man visited our hospital with a large soft tissue defect in his left greater trochanteric area by traffic accident. The patient had wide skin and soft tissue defect combined with open femur fracture. During one month period of admission, he underwent femur open reduction and wound debridement four times. After that we planned thoracodorsal perforator free flap reconstruction. The flap was outlined as large as $20{\times}15\;cm$ and elevated in a suprafascial plane from the lateral border. During intramuscular perforator dissection, we found that two 1.5 mm diametered perforator vessels coursed inferomedially toward second lumbar region. Finally the flap became lumbar artery perforator flap based on second lumbar artery perforator as a main pedicle. After flap transfer, the perforator vessels were connected with inferior gluteal artery and vein microsurgically. The operation was successful without uneventful course. We found no significant postoperative complication and donor site morbidity during six months follow up periods. Lumbar artery perforator flap could be an alternative procedure for thoracodorsal perforator flap in some patients with anatomic variant features.

  • PDF

Preoperative Identification of a Perforator Using Computed Tomography Angiography and Metal Clip Marking in Perforator Flap Reconstruction

  • Lee, Jung Woo;Kim, Han Kyeol;Kim, Sin Rak;Han, Yea Sik;Park, Jin Hyung
    • Archives of Plastic Surgery
    • /
    • v.42 no.1
    • /
    • pp.78-83
    • /
    • 2015
  • In perforator flap reconstruction, vascular mapping using preoperative computed tomography (CT) angiography is widely used to confirm the existence and location of an appropriate perforator. This study proposes a rapid, accurate, and convenient method for marking the perforator location on the skin surface. For 12 patients who underwent perforator flap reconstruction between November 2011 and November 2013, metal clips were fixed on the skin surface at the anticipated perforator locations, which were decided using a handheld Doppler. CT angiography was used to compare the location between the metal clip and the actual perforator. The metal clip was moved and repositioned, if needed, on the basis of the CT images. The locations of the appropriate perforator and the metal clip, which were observed during the surgery, were then compared. In CT angiography, the mean distance between the metal clip and the perforator was $3{\pm}3.9mm$, and the mean distance that was measured during surgery was $0.8{\pm}0.8mm$. In conclusion, we report a simple, rapid, and precise technique to indicate the accurate location of the appropriate perforator on the skin surface.

Comparison of Formaldehyde Emission of Wood-based Panels with Different Adhesive-hardener Combinations by Gas Chromatography and Standard Methods

  • Eom, Young Geun;Kim, Sumin;Baek, In-Chan;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.2 s.130
    • /
    • pp.29-39
    • /
    • 2005
  • Formaldehyde emissions from wood-based panels bonded with pine and wattle tannin-based adhesives, urea-formaldehyde resin (UF), melamine-formaldehyde resin (MF), and co-polycondensed resin of urea-melamine-formaldehyde (UMF) were measured by the Japanese standard method using a desiccator (JIS A 1460) and the EN 120 (European Committee For Standardization, 1991) method using the perforator value. In formaldehyde emission, all particleboards made using the wattle tannin-based adhesive with three different hardeners, paraformaldehyde, hexamethylenetetramine, and tris(hydroxyl)nitromethan (TN), satisfied the requirements of grade $E_1$. But only those made using the pine tannin-based adhesive with the hexamine as hardener met the grade $E_1$ requirements. Hexamine was effective in reducing formaldehyde emission in tannin-based adhesives when used as the hardener. While the UF resin showed a desiccator value of $7.1mg/{\ell}$ and a perforator value of 12.1 mg/100 g, the MF resin exhibited a desiccator value of $0.6mg/{\ell}$ and a perforator value of 2.9 mg/100 g. According to the Japanese Industrial Standard and the European Standard, the formaldehyde emission level of the MDF panels made with UF resin in this study came under grade $E_2$. The formaldehyde emission level was dramatically reduced by the addition of MF resin. The desiccator and perforator methods produced proportionally equivalent results. Gas chromatography, a more sensitive and advanced method, was also used. The samples for gas chromatography were gathered during the experiment involving the perforator method. The formaldehyde contents measured by gas chromatography were directly proportional to the perforator values.

Comparison Between the Digital Artery Perforator Flaps and the Distant Flaps within Hand (수지동맥천공지피판과 수부 내 원거리피판의 재건의 비교)

  • Cho, Pil-Dong;Moon, Min-Seon;Shin, Keuk-Shun
    • Archives of Plastic Surgery
    • /
    • v.37 no.1
    • /
    • pp.52-58
    • /
    • 2010
  • Purpose: The digital artery perforator flap was recently introduced and has been proven to be useful for reconstruction of various finger defects. Short operative time, less invasive surgery, and reliable flap circulation are the major advantages of this flap. The authors presented the clinical cases of the digital artery perforator flap and compared them with the distant flaps within a hand (thenar and hypothenar flaps) to reveal their differences. Methods: From May of 2006 to February of 2009, the authors performed reconstructions of finger defects with the digital artery perforator flaps in 10 patients as with the distant flaps within hand in 9 patients (7 thenar and 2 hypothenar flaps). In these two groups of the patients, flap size, use of skin graft, length of stay in hospital, healing time, complications were reviewed retrospectively and compared with statistical analysis (Student's t-test). Results: All flaps survived completely. The mean size of the perforator flap was $0.9{\times}1.9\;cm$ and the mean distant flap within a hand was $1.9{\times}2.0\;cm$. The use of skin graft was reduced in the perforator group because the donor site of the flap was closed primarily. The hospitalization period and healing time also reduced significantly in the perforator group. Minor complications (partial flap loss) were noted in small percentages in both groups but resolved with conservative management. Mean follow-up period was about 6 weeks. Conclusion: The digital artery perforator flap was smaller than the distant flap but its reconstruction of finger defects was reliable and comparable to the conventional distant flaps within a hand. This flap would be not only an alternative method but very useful in the management of various finger defects, because of ease of operative technique, less invasive surgery, decreased need of skin graft, and shorter period of hospitalization and healing time.

Various Designs of Gluteal Artery Perforator Flap for Buttock Reconstruction (둔부재건을 위한 천공지피판의 다양한 도안)

  • Hong, Seung Eun;Pyon, Jai Kyong
    • Archives of Plastic Surgery
    • /
    • v.34 no.2
    • /
    • pp.197-202
    • /
    • 2007
  • Purpose: The gluteal artery perforator flaps earned its popularity in buttock reconstruction due to the lower morbidity of the donor site and the flexibility in the design. Speedy and safe reconstruction is important for the success of buttock reconstruction. If a proper design is selected, satisfactory results can be obtained with more simple method of surgery. Methods: Between April 2005 and April 2006, buttock reconstruction by using gluteal artery perforator flaps were performed on sacral sores(6 cases), ischial sores(2 cases) and malignant melanoma on buttock(1 case). Various designs depending on the location and the size of the defect was made. In those designs, perforator was used as an axis for the minimal dissection of the vessel. Donor site from which sufficient amount of soft tissue can be transferred was selected, and also not causing high tension against the recipient site during the donor site closure. In addition, postoperative aesthetics, and the possibility of another design of a second operation which can be necessary in the future, was considered. Results: Patient follow up was for a mean period of 10.8 months. All flaps survived except for one that had undergone partial necrosis. Wound dehiscence was observed in one patient treated by secondary closure. Most patients presented with cosmetically and functionally satisfying results Conclusion: By designing the flap using the perforator as an axis, depending on the defect size and degree, reconstruction can be performed with only a small tension to the donor and the recipient site. And the minimal perforator dissection allowed easier and faster reconstruction. Selection of a proper design is the key procedure which greatly affects operation time and result success.

Scrotal Reconstruction with Pedicled Anterolateral Thigh Perforator Flap. (유경 전외측 대퇴부 천공지 피판을 이용한 음낭재건)

  • Kim, Byung Jun;Heo, Chan Yeong
    • Archives of Plastic Surgery
    • /
    • v.36 no.3
    • /
    • pp.348-350
    • /
    • 2009
  • Purpose: The objective of this study is to present a reliable method of scrotal reconstruction. Methods: 75 year - old - man visited the out patient department of urology for chronic itching sensation in his scrotal area, diagnosed as Bowen's disease. After the wide resection of scrotal lesion, reconstruction was carried with pedicled anterolateral thigh perforator flap. All operation procedure was done with an usual manner, previously reported. Donor site was closed primarily. Results: In 6th month follow - up period, there was no event, such as flap necrosis, wound dehiscence, tumor recurrence. And tactile sensation was recovered. Conclusion: In the Korean literature, there have not been the report that describes the reconstruction of scrotal defect using pedicled anterolateral thigh perforator flap. Pedicled anterolateral thigh perforator flap is reliable and robust flap for scrotal reconstruction.

Soft Tissue Coverage Using a Combined Gastrocnemius-medial Sural Artery Perforator Flap (비복근 - 내측 비복 동맥 천공지 복합 피판을 이용한 연부조직 재건)

  • Lee, Jae-Hoon;Son, Eun-Suck
    • Archives of Reconstructive Microsurgery
    • /
    • v.17 no.1
    • /
    • pp.1-6
    • /
    • 2008
  • Medial gastrocnemius flap has been known as a useful option for soft tissue reconstruction of the knee and upper 1/3 of lower extremity, but it has a limitation to cover the lateral defect of the knee joint. We performed the combined gastrocnemius-medial sural artery perforator flap for coverage of the anterolateral defects of the knee joint, which is compound flap using a medial gastrocnemius flap and a medial sural artery perforator flap. This flap is a useful method for reconstruction of anterolateral knee defects, providing a easy dissection without the microsurgery and intramuscular dissection of the perforators.

  • PDF

The Treatment of Trochanteric Pressure Sore Using Superior or Inferior Gluteal Artery Perforator Flap (상.하둔동맥 천공지피판을 이용한 대전자부 욕창의 치료)

  • Tark, Woo-Hyun;Lee, Won-Jai;Yun, In-Sik;Rah, Dong-Kyun
    • Archives of Plastic Surgery
    • /
    • v.38 no.3
    • /
    • pp.235-240
    • /
    • 2011
  • Purpose: Management of pressure sores has been improved, along with development of musculocutaneous flaps and perforator flaps. Nowadays, the treatment of pressure sore with perforator flaps has shown several advantages, including minimal donor site morbidity, relatively versatile flap design not only in primary cases but also in recurred cases and minimized anatomical rearrangement of regional muscle position. In this study, we report our clinical experience of gluteal perforator flap used in the treatment of a greater trochanteric pressure sore. Methods: A clinical study was performed on 7 patients who underwent total 10 operations. 1 superior gluteal artery perforator flap and 9 inferior gluteal artery perforator flaps were used to reconstruct the defect, followed by the mean observation duration of 22 months. Results: There were no total flap loss. We treated 2 cases of partial flap loss with debridement and primary repair. 2 recurred cases were successfully treated using the same method. Donor sites were all primarily repaired. Conclusion: The gluteal perforator flap could be considered as a safe and favorable alternative in the treatment of soft tissue defects in the greater trochanteric area. The advantages of the flap include low donor site morbidity and the possibility of versatile flap design not only in primary cases but also in recurred cases.

Lower Extremity Reconstruction by Perforator Based Flap (천공지 기저 피판을 이용한 다양한 하지 재건)

  • Oh, Chang Hyun;Shim, Jeong Su;Park, Dae Hwan
    • Archives of Plastic Surgery
    • /
    • v.36 no.6
    • /
    • pp.720-726
    • /
    • 2009
  • Purpose: Fasciocutaneous flap with random pattern flap has limitation in mobility and length - width ratio. This characteristic is more pronounced in lower extremity which has relatively poor vascularity. Perforator based flap in lower extremity reconstruction has various advantages as a axial flap, allowing abundant blood supply and widening of mobility range. So if it is not a case of wide defect, free flap can be replaced by perforator based flap. Methods: From April 2007 to March 2009, 18 cases of perforator flap were performed. 8 had defect in upper 1/3 of calf, 6 in middle 1/3, and 4 in lower 1/3. In 10 cases island flap were used, 3 case had transposition flap, 2 cases used advancement flap, 2 case had propeller flap and 1 case had rotation flap. Results: 17 cases survived without flap necrosis. Partial flap necrosis occurred in 1 case, so secondary split thickness skin graft was done. Chronic wound with pseudomonas infection occurred in 1 case, but it was completely cured with conservative treatment. Conclusion: Perforator based flap is useful in lower extremity reconstruction because of relative freedom in changing the size and thickness of the flap depending on the recipient site, good mobility, and abundant vascularity. And donor site morbidity can be minimized. Lower extremity reconstruction using perforator based flap is a good method because it can minimize the complication and obtain effective result.

Reconstruction of Fingertip Amputation by Using Digital Artery Perforator Flap (수부동맥 관통 피판을 이용한 손가락끝 절단의 재건)

  • Ha, Young In;Jung, Sung Gyun;Shin, Ho Seong;Park, Eun Soo;Park, Jang Woo;Choi, Hwan Jun
    • Archives of Plastic Surgery
    • /
    • v.35 no.4
    • /
    • pp.483-486
    • /
    • 2008
  • Purpose: Fingertip injuries are the most common hand injuries and may lead to significant disability. Knowledge of fingertip anatomy is mandatory to treat these injuries effectively. All surgical techniques used for coverage of fingertip injuries must be based on the nature of the injury and the patient's age. Many authors have studied the method of fingertip reconstruction because goals of these treatments should include maintaining length, sensibility, motions, and appearance. The purpose of this study is to evaluate the effect of digital artery perforator flap for fingertip reconstruction without aesthetic and functional problems. Methods: From November 2006 to March 2007, the authors performed fingertip reconstruction on 3 fingers of 3 patients, aged between 41 to 54 years (average age, 47 years) using digital artery perforator flap. Results: All fingers recovered successfully and there were no necrosis of the flap. We followed up 3 cases more than 5 months. Light touch and temperature sensation could be detected in all flaps and the static two-point discrimination test was 8 mm. Conclusion: This flap is an alternative choice for coverage of fingertip defects. This method also takes short time to procedure and to recovery. The digital artery perforator flap has never been reported in Korea, however it is considered as a useful method for treatment of fingertip injury.