• 제목/요약/키워드: perforated baffle

검색결과 19건 처리시간 0.02초

공기식 PVT 컬렉터에 적용된 타공 베플의 변수에 따른 열 성능 향상을 위한 연구 (A Study for Improving Thermal Performance According to Variables of Perforated Baffle in Air-type PVT Collector)

  • 유지숙;김진희;김준태
    • 한국태양에너지학회 논문집
    • /
    • 제39권6호
    • /
    • pp.83-91
    • /
    • 2019
  • Photovoltaic thermal (PVT) collectors are devices that simultaneously produce electricity and heat. Research on conventional air-type PVT collector focuses on installing baffles to enhance the collector's thermal performance. However, the baffles have pressure drop inside the collector which degrades the thermal performance. Thus, it is necessary to design baffles to smoothen the flow inside the air-type PVT collector. Alternatively, installing perforated baffles in air-type PVT collectors can reduce the collector weight, but parameters such as the diameter of the perforated holes and the height of the perforated plates should be considered. Therefore, the main aim of this study was to analyze thermal characteristics of each variable of perforated baffles installed inside air-type PVT collector. For this purpose, the uniformity of air flow in the collector was compared through NX program, and the resultant heat gain and thermal efficiency of the air-type PVT collector were compared and analyzed. Therefore, the main aim of this study was to analyze thermal characteristics of each variable (Baffle angle, length, height, pitch, perforated ratio) of perforated baffles installed inside air-type PVT collector. For this purpose, the uniformity of air flow in the collector was compared through CFD program, and the resultant heat gain and thermal efficiency of the air-type PVT collector were compared and analyzed. As a result, the maximum outlet temperature was increased by 1.45 times and the heat gain was increased by 193.8 Wth, depending on the perforated baffle plate, compared to the collector without the baffle. The heat transfer performance showed that the maximum internal velocity was 1.61 times higher and the Reynolds number was 1.06 times higher depending on the parameters of the baffle plate.

Heat Transfer and Friction Behaviour in a Channel with an Inclined Perforated Baffle

  • Krishna Putra, Ary Bachtiar;Ahn, Soo-Whan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제16권2호
    • /
    • pp.70-76
    • /
    • 2008
  • The effects of the inclined perforated baffles on the distributions of the local heat transfer coefficients and friction factors for air flows in a rectangular channel were determined for Reynolds numbers from 23,000 to 57,000. Four different types of the baffle are used. The inclined baffles have the width of 19.8cm, the square diamond type hole having one side length of 2.55cm, and the inclination angle of $5^{\circ}$, whereas the corresponding channel width-to-height ratio was 4.95. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle, and the heat transfer performance of baffle type II (3 hole baffle) has the best value.

Thermo-hydraulic Effect of Tubular Heat Exchanger Fitted with Perforated Baffle Plate with Rectangular Shutter-type Deflector

  • Md Atiqur Rahman
    • Korean Chemical Engineering Research
    • /
    • 제62권2호
    • /
    • pp.191-199
    • /
    • 2024
  • A study was conducted on a tubular heat exchanger to improve its heat transfer rate by using a novel baffle plate design with discontinuous swirling patterns. The design consisted of perforated baffle plates with rectangular air deflectors positioned at varying angles. The tubes in the heat exchanger were arranged in a consistent alignment with the airflow direction and exposed to a uniform heat flux on their surfaces. Each baffle plate included sixteen deflectors inclined at the same angle and arranged in a clockwise pattern. This arrangement induced a swirling motion of the air inside a circular duct where the heated tubes were located, leading to increased turbulence and improved heat transfer on the tube surfaces. The spacing between the baffle plates was adjusted at different pitch ratios, and the Reynolds number was controlled within a range of 16,000 to 29,000. The effects of pitch ratios and inclination angles on the heat exchanger's performance were analyzed. The results indicated that using a baffle plate with rectangular deflectors inclined at 30° and a pitch ratio of 1.2 resulted in an average increase of 1.29 in the thermal enhancement factor.

연구용 원자로 유입 공동에서 다공형 차폐물에 의한 와류 감쇄효과 예측 (Prediction of Vortex Reducing Effect by a Peforated Baffle in the Inlet Plenum of a Research Reactor)

  • 박종학;채희택;박철;김헌일
    • 한국전산유체공학회지
    • /
    • 제9권2호
    • /
    • pp.11-17
    • /
    • 2004
  • CFD analysis was performed to figure out flow behavior in the inlet plenum of new research reactor where coolant is injected to the flow tubes with the fuel assembly. The computation results showed that large-scale vortices are generated in the inlet plenum by flow stream injected from inlet pipe. These vortices are divided into small vortices and reversed their revolution. They may lead to flow-induced vibration of fuel assembly, moreover, which has been regarded as a cause of fretting wear of fuel assembly. Also there is an another important thing that average velocity of each flow-tube is uneven showing difference in maximum 18%. So it has been suggested that perforated baffle will be installed to prevent the formation of vortex in the inlet plenum. Two perforated baffles, one is flow skirt and the other is muffler type flow straightener, were proposed and their effect was evaluated using commercial CFD code, Fluent. According to CFD analysis for two perforated baffles, it was confirmed that both of them can prevent or reduce vortex formation in the inlet plenum and make average velocity of each flow tube more even.

A Numerical Study on Heat Transfer and Friction in Rectangular Channel with Inclined Perforated Baffles

  • Putra, Ary Bachtiar Krishna;Ahn, Soo-Whan;Kang, Ho-Keun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권7호
    • /
    • pp.1003-1012
    • /
    • 2008
  • A three dimensional numerical study has been applied to predict the turbulent fluid flow and heat transfer characteristics for the rectangular channel with different types of baffles. Four different types of the baffles are used. The inclined baffles have the width of 19.8 cm, the square diamond type hole having one side length of 2.55 cm, and the inclination angle of $5^{\circ}$. Reynolds number is varied between 23,000 and 57,000. The SST k-${\omega}$ turbulence model is used in the present numerical study. The validity of the numerical results is examined with the experimental data. The numerical results of the flow field depict that the flow patterns around the different baffle type are entirely different and it significantly affects the local heat transfer characteristics. The heat transfer and friction factor depend significantly on the number of baffle holes. It is found that the heat transfer enhancement of baffle type II (3 hole baffle) has the best values.

정 다이아몬드 형 구멍이 있는 배플을 가진 채널에서의 열전달과 마찰계수 (Heat Transfer and Friction Factors in the Channel with an Inclined Square Diamond Type Perforated Baffle)

  • 오세경;아리바시아크리시나부트라;안수환
    • 동력기계공학회지
    • /
    • 제12권3호
    • /
    • pp.26-31
    • /
    • 2008
  • This experimental study investigates the local heat transfer enhancement characteristics and the associated frictional head loss in the rectangular channel with a single inclined baffle. Four different types of the baffle are used. The inclined baffles have the width of 19.8 cm, the square diamond of $2.55cm{\times}2.55cm$, and the inclination angle of 5o, and number of holes of up to 9. Reynolds number is varied between 23,000 and 57,000. Results show that the heat transfer and friction factor depend significantly on the number of baffle holes and Reynolds number. The friction factor decreases with increasing Reynolds number and the number of holes on the baffle. It is found that the heat transfer performance of baffle type II(3 hole baffle) has the best values.

  • PDF

평판 예혼합 세라믹 버너의 분포판 변화에 따른 연소화염특성과 안정성 분석 (Combustion Characteristic and Stability of Flat Premixed Ceramic Burner with Different Porous Baffle Plates)

  • 이재영;이필형;박창수;박봉일;황상순
    • 한국연소학회지
    • /
    • 제14권4호
    • /
    • pp.7-16
    • /
    • 2009
  • Porous metal plates (Metal fiber, muti-hole metal plate) using mainly in surface burner are known to have a corrosion and durability problem under high temperature condition. In this study, premixed flat flame with perforated ceramic tile of more durable cordierite material was examined with respect to combustion stability and emission. The flat premixed ceramic burner consists of perforated ceramic tile and various type of baffle plates to form stable surface flame. The results show that most stable flat flame is generated using baffle plate with open ratio of 0.193. In downward flat flame mode which is widely used in condensing boiler, CO is measured below 50ppm from equivalence ratio 0.755 to 0.765 and $NO_X$ is measured below 12ppm from equivalence ratio 0.75 to 0.79. It is also found that the range of blue flame in flame stability curve becomes wider with increasing heat capacity.

  • PDF

구멍이 있는 2개의 경사진 배플이 있는 채널에서의 열전달에 대한 실험적 연구 (Experimental Investigation of Heat Transfer in the Channel with Two Inclined Perforated Baffles)

  • 아리바시아 크리시나 부트라;안수환;강호근
    • 동력기계공학회지
    • /
    • 제12권4호
    • /
    • pp.39-45
    • /
    • 2008
  • 본 연구는 두 개의 경사진 다공 배플이 설치된 사각채널에서 국부 열전달향상 특성을 조사하였다. 채널은 19.8cm(W)$\times$4cm(H)의 단면적을 가지며 형상계수는 4.95이며 수력직경은 6.66cm이다. 4종류의 배플을 취급하였다. 가열 시험부에 동일한 크기, 경사각, 구멍형태의 경사 배플을 설치하였다. 경사 배플은 모두 19.8 cm의 폭, $2.55cm\times2.55cm$의 정 다이아몬드 형 구멍, 그리고 So의 경사각을 갖는다. 레이놀즈 수 범위는 23,000에서 57,000까지이다. 배플의 구멍의 수가 열전달 향상에 중요한 역할을 하였으며 구멍이 3개 인(baffle type II)가 가장 우수한 열전달 향상을 보였다.

  • PDF

경사판 침전지의 수리학적 특성에 대한 구조물의 영향 (Effects of Various Baffles on Hydraulic Characteristics in the Sedimentation Basin with Inclined Plate Settler)

  • 유명진;김현철;명규남;류성호;조항문
    • 상하수도학회지
    • /
    • 제18권4호
    • /
    • pp.427-436
    • /
    • 2004
  • Sedimentation is one of the most common and important units in conventional water treatment plants. Structure such as various baffle walls and inclined plate settler may be obstacles to the horizontal flow when it is poorly designed. Therefore, the effects of these structures on characteristics of hydraulic flow must be evaluated to improve the settling efficiency of the floc. The hydraulic characteristic of the four sedimentations at the three real WTPs (water treatment plants), which have different structural properties respectively inside the settling basin, were investigated by tracer (fluoride) test. The inclined plate settler installed inside settling basin caused a undesirable impact on horizontal flow and produced dead zone. Intermediate baffle and solid baffle wall under the inclined plate settler at GE plant help to minimize the formation of density currents and flow short circuiting. However, installing perforated baffle under the inclined plate settler at other plants could not induce even distribution of flow. NaF used as a tracer was recovered more than 90% at investigated all basin. Morill index ($t_{90}/t_{10}$), Modal index ($t_p/T-HRT$) and short-circuiting index ($[M-HRT-t_p/M-HRT$) were determined from tracer test results performed at three WTPs. Those indices ranged 2.99~3.45, 0.44~0.72 and 0.23~0.47, respectively.

용존공기부상조(DAF-tank)의 형상변화가 분리조(Separation Zone)의 내부 유동 패턴에 미치는 영향에 대한 수치해석적 연구 (Numerical Study of Effect of DAF-Tank Shape on Flow Pattern in Separation Zone of Dissolved Air Flotation)

  • 류광년;박상민;이호일;정몽규
    • 대한기계학회논문집B
    • /
    • 제35권8호
    • /
    • pp.855-860
    • /
    • 2011
  • 용존공기부상조의 파일럿실험장치 설계를 위한 사전 검증 작업으로서 부상조의 유동을 이차원 이상유동으로 가정하여 수치적으로 모사하였다. 형상이 변경된 다양한 부상조와 기준부상조와의 간접적인 성능 비교를 위하여 분리조에서의 하강속도를 비교하였다. 해석 결과 기준부상조의 분리조에서는 잘 설계된 High-rate DAF 의 전형적인 유동 패턴이 관찰되었다. 이러한 유동패턴은 Baffle 각도나 접촉조의 폭과 같은 다른 형상 변수와 상관없이 Baffle 이 충분히 높을 때 잘 유지되었다. 그러나 Baffle 높이 및 각도, 접촉조의 폭 및 다공판의 설치유무는 분리조에서 하강속도의 균일성에 영향을 미쳤다. 기준부상조에서 Baffle의 높이를 제외한 다른 형상을 변화시키지 않았을 때, 분리조에서의 하강속도가 균일한 것으로 나타났다. 이것은 기준부상조의 형상최적화가 잘 되어있음을 의미한다.