• Title/Summary/Keyword: per-cooling

Search Result 248, Processing Time 0.026 seconds

Prediction of boil-off gas and boil-off rate in cargo tank of NGH carrier

  • Kang, Ho-Keunn;Kim, Dongeum;Kim, You-Taek;Park, Jung-Dae;Kang, Shin-Baek
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.10
    • /
    • pp.1002-1010
    • /
    • 2015
  • Natural gas hydrates are newly emerging as an environment-friendly source of energy to substitute for fossil fuels in the 21stcentury.NGHs are reported to holds much amounts of natural gas (up to 182 standard volumes of gas per volume of hydrate); they are easy to store and safe to carry at about minus 20 degree Celsius under atmospheric pressure because of the self-preservation phenomenon of gas hydrates. The transporting method by gas-ice-hydrate ship carriers has been introduced and developed by a variety of industry and research institutions. Our team has been conducted to develop NGH total systems, including a breakthrough NGH carrier for sea transportation, since 2011. The NGH pellet carrier does not require a separate cooling system for cargo, and the initial temperature is maintained through insulation of the cargo tanks throughout the transport to the final destination. The heat conducted from the exterior and passing through the insulation material of the hull should be cut off as much as possible, but heat inflow inside the cargo tank from an external source is inevitable during transport. In this study, the heat transfer in a cargo tank of a 115K NGH carrier was analyzed through simulation with a commercial CFD code to estimate the boil-off gas/boil-off rate on the developed carrier and understand major hazards that could significantly impact the safety of the vessel.

Characteristics of the Water Pressure Drop Considering Heat Transfer in the Evaporator and Condenser of a Water Chiller (냉수공장에서 열전달을 고려한 응축기와 증발기의 물 압력강하 특성)

  • Nguyen, Minh Phu;Lee, Geun-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.12
    • /
    • pp.1293-1300
    • /
    • 2011
  • The configurations of the evaporator and condenser of a water chiller can be determined from the trade-off between the heat transfer area, which is related to the capital cost and the pressure drop, which is associated with the operational cost. In this study, the design of the water chiller focused on minimizing the water pressure drop of both condenser and evaporator for given cooling capacity and requirements. Commercial enhanced tubes were employed to simulate real-life conditions. The results of the present analysis were compared with those obtained by HTRI software for verifying them. The results indicated that a reduction in the water pressure drop, which is associated with the short length of a tube, can be effected by decreasing the number of tube passes and increasing the number of tubes and the tube diameter. However, using a large number of tubes with smaller diameters can reduce the capital cost because the tubes are short. The reduction of the capital cost is due to the fact that a small-diameter tube has low internal thermal resistance and hence contributes to a decrease in the overall thermal resistance per unit length.

Indoor Neutral Temperature Range using Temperature and Humidity Perception Assessment

  • Yang, Wonyoung
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.29-37
    • /
    • 2016
  • Purpose: Indoor thermal comfort can be identified by combination of temperature, humidity, and air flow, etc. However, most thermal indexes in regard to thermal comfort are temperature dominant since it has been considered as a significant factor affecting to indoor thermal comfort The purposes of this study are to investigate indoor neutral temperature range of young Koreans with humidity perception, and to introduce a neutral temperature for temperature preference as well as temperature sensation in order to define the neutral temperature range chosen by occupants. It could be used as basic data for heating and cooling. Method: 26 research participants volunteered in 7 thermal conditions ($18^{\circ}C$ RH 30%, $18^{\circ}C$ RH 60%, $24^{\circ}C$ RH 30%, $24^{\circ}C$ RH 40%, $24^{\circ}C$ RH 60%, $30^{\circ}C$ RH 30%, $30^{\circ}C$ RH 60%) and completed subjective assessment in regard to temperature/humidity sensation and preference twice per condition in an indoor environmental chamber. Result: In RH 30%, sensation neutral temperature was $25.1^{\circ}C$ for men and $27.0^{\circ}C$ for women, and preference neutral temperature was $25.5^{\circ}C$ for men and $27.8^{\circ}C$ for women. In RH 60%, sensation neutral temperature was $23.6^{\circ}C$ for men and $25.9^{\circ}C$ for women, and preference neutral temperature was $23.4^{\circ}C$ for men and $26.3^{\circ}C$ for women. Neutral temperature increased with increasing relative humidity. Women were sensitive to humidity changes. Men expressed humidity changes as temperature variations. In most conditions, preference neutral temperatures were higher than sensation neutral temperatures, however, the preference neutral temperature for men in humid condition was lower than the sensation neutral temperature.

Numerical Simulation of Heat Transfer in Chip-in-Board Package (Chip-in-Board 패키지의 열전달 해석)

  • Park, Joon Hyoung;Shim, Hee Soo;Kim, Sun Kyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.75-79
    • /
    • 2013
  • Demands for semiconductor devices are dramatically increasing, and advancements in fabrication technology are allowing a step-up in the number of devices per unit area. As a result, semiconductor devices require higher heat dissipation, and thus, cooling solutions have become important for guaranteeing their operational reliability. In particular, in chip-in-board packages, in which chips and passives are embedded in the substrates for efficient device layout, heat dissipation is of greater importance. In this study, a thermal model for layers of different materials has been proposed, and then, the heat transfer has been simulated by imposing a set of appropriate boundary conditions. Heat generation can be predicted based on the results, which will be utilized as practical data for actual package design.

A Study on the Condensation Heat Transfer and Pressure Drop in Internally Grooved Tubes Used in Condenser (응축기용 낮은 핀관의 내부 나선 홈에 의한 응축 열전달 성능과 압력손실에 관한 연구)

  • Han, Kyuil;Cho, Dong-Hyun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.34 no.2
    • /
    • pp.212-222
    • /
    • 1998
  • Heat transfer performance improvement by fin and groovs is studied for condensation of R-11 on integral-fin tubes. Eight tubes with trapczodially shaped integral-fins having fin density from 748 to 1654fpm(fin per meter) and 10, 30 grooves are tested. A plain tube having the same diameter as the finned tubes is also used for comparison. R-11 condensates at saturation state of 32 $^{\circ}C$ on the outside tube surface coded by inside water flow. All of test data are taken at steady state. The heat transfer loop is used for testing singe long tubes and cooling is pumped from a storage tank through filters and folwmeters to the horizontal test section where it is heated by steam condensing on the outside of the tubes. The pressure drop across the test section is measured by menas pressure gauge and manometer. The results obtained in this study is as follows : 1. Based on inside diameter and nominal inside area, overall heat transfer coefficients of finned tube are enhanced up to 1.6 ~ 3.7 times that of a plain tube at a constant Reynolds number. 2. Friction factors are up to 1.6 ~ 2.1 times those of plain tubes. 3. The constant pumping power ratio for the low integral-fin tubes increase directly with the effective area to the nominal area ratio, and with the effective area diameter ratio. 4. A tube having a fin density of 1299fpm and 30 grooves has the best heat transfer performance.

  • PDF

Storage potential of low temperature adapted shiitake mushroom under freezing temperature (저온성 표고버섯의 빙점하 저장 잠재력)

  • Hwang, Yong Soo;Seo, Geon Sik
    • Korean Journal of Agricultural Science
    • /
    • v.40 no.3
    • /
    • pp.197-202
    • /
    • 2013
  • This study was aimed to find the storage potential of low temperature adapted shiitake mushroom under freezing temperature ($-3^{\circ}C$). Fresh shiitake mushroom was harvested at late Feb. and cooled to target temperature, $-3^{\circ}C$ in the cooling room for 24 hr. Cooled mushroom were then placed in plastic boxes, wrapped with plastic film ($30{\mu}m$), and stored at $-3^{\circ}C$ for 2 months. Weight loss of mushroom was ranged from 2.1 to 3.2%. Dry weight per unit fresh weight, however, was slightly increased because of moisture loss. Firmness of fruit body increased from $0.95kg/cm^{-2}$ (before storage) to $1.13kg/cm^{-2}$ (after 2 month storage). About half amount of starch was lost during 2 month storage. The amount of total and reducing sugars remained relatively constant. After storage, freshness of mushroom was recovered by thawing treatment. When recovered mushroom were packaged with styrofoam tray and PVC wrapping, and exposed to ambient and $10^{\circ}C$, respectively, brown spot on the gill of fruit body was found and slight decay symptom was also found at ambient temperature only but not at $10^{\circ}C$. Results indicated that low temperature adapted shiitake mushroom has a storage potential under freezing temperature ($-3^{\circ}C$). Freezing storage technology of fresh shiitake mushroom will contribute the increase of storability up to 2 months.

The Effect of Tai Chi Exercise in Elderly Women (여성노인에 대한 타이치 운동의 효과)

  • Park, Young-Ju;Park, In-Hyae
    • Journal of muscle and joint health
    • /
    • v.15 no.2
    • /
    • pp.119-129
    • /
    • 2008
  • Purpose: The purpose of this study was to identify the effect of Tai Chi exercise program on pain, fatigue, depression, self-efficacy, and quality of life in elderly women. Method: A quasi-experimental design, a nonequivalent control group pretest-posttest was the method of this study. Elderly women who agreed to participate in the study were conveniently placed into an experimental group (n=33) or an control group (n=34). The experimental group participated in Tai Chi exercise program, which was held for 60 minutes per session and 3 times a week for 8 weeks. Tai Chi exercise program consisted of a 10 minute warm-up, a 45 minute main session, and a 5 minute cooling down. In order to evaluate the effects of Tai Chi exercise program, pain, fatigue, depression, self-efficacy, and quality of life were measured with a questionnaire. The data were analyzed using Chi-square test, Fisher's exact test, t- test, and ANCOVA by SPSS WIN 13.0 program. Results: Compared with the control group, the experimental group reported higher level of quality of life (F=7.67, p=.007) and self-efficacy (F=20.9, p=.000) and lower level of pain (F=10.93, p= .002), fatigue (F=6.28, p=.015), and depression (F=10.02, p=.002). Conclusions: This study suggests that Tai Chi exercise program may be one of the effective nursing interventions for elderly women.

  • PDF

An Analysis on the Characteristics of Energy and Water Consumption in Urban Rental Apartment (도심 임대아파트의 에너지 및 상수 소비 특성에 관한 연구)

  • Seo, Youn-Kyu;Kim, Ju-Young;Hong, Won-Hwa
    • Journal of the Korean housing association
    • /
    • v.20 no.6
    • /
    • pp.39-46
    • /
    • 2009
  • It has been a serious problem to consume the energy of apartment while increasing to use of heating & cooling System because of residence environmental upgrades. Great attention has been shown to the problem of the rental apartment, so there are few reports of energy consumption about the rental apartment in korea. To solve the lack of housing, our country has supplied an enormous volume of apartments, and these days it occupies 75% of our buildings. As apartments occupy most of our housings, the rate of energy usage from them are also high. On this, setting apartment energy reduction as a target, by researching the actual conditions of energy consumption and drawing a basis data, we can apply this as a way of saving energy, rationalization of the scale of energy supply facilities and a standard when planning facilities. To grasp the present condition of energy usage of the urban rental apartment, this research analysed the use of electricity, gas and water monthly and annually of a rental apartment that is located in Daegu. The results showed that in 2003 the electricity usage was 1,198MWh but 1,315MWh in 2007, which means 9% of electricity usage increases every year. The average of water usage was $85,072\;m^2$ per year and typical energy consumption unit was $604.2\;MJ/m^2$ on $74.4\;m^2$ of area and $448.8\;MJ/m^2$ on $105.8\;M^2$. By showing the usage of energy and water of the urban rental apartment, understanding the tendency and preparing an typical energy consumption unit standard through this research, apartments should use energy more efficiently.

Crystallographic Analysis of Ar Encapsulate within Cs3-A Zeolite

  • Lim, Woo Taik;Kim, Bok Jo;Park, Jong Sam;Chang, Chang Hwan;Jung, Sung Wook;Heo, Nam Ho
    • Analytical Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.540-549
    • /
    • 2002
  • The arrangement of encapsulated Ar atoms in the molecular-dimensioned cavities of fully dehydrated zeolite A of unit-cell composition $Cs_3Na_8HSi_{12}Al_{12}O_{48}$ ($Cs_3$-A) has been studied crystallographically to probe the confinement effect of guest species in microporous environment. Atoms of Ar were encapsulated in the cavities of $Cs_3$-A by treatment with 410 atm of Ar at $400^{\circ}C$ for two days, followed by cooling at room temperature. The crystal structure of $Cs_3Na_8H$-A(4Ar) ($P_e$ = 410 atm, $a=12.245(2){\AA}$, $R_1=0.0543$, and $R_2=0.0552$) has been determined by single crystal X-ray diffraction technique in the cubic space group $Pm\bar{3}m$ at 21 (1) $^{\circ}C$ and 1 atm. Encapsulated Ar atoms are distributed in three crystallographic distinct positions: 1.5 Ar atoms per unit cell opposite 6-rings, 1.5 opposite four-rings in the large cavity, and finally 1.0 in the sodalite-unit. The possible structures of argon clusters, such as $Ar_2$, $Ar_3$, and $Ar_4$, are proposed.

The Effect of the Taeguk Gi-Gong Exercise on Insulin Resistance and Blood Glucose in Patients with Type II Diabetes Mellitus (태극건강기공이 제 2형 당뇨인의 인슐린저항성 및 혈당에 미치는 효과)

  • Jeong, Ihn-Sook;Lee, Hwa-Ja;Kim, Myung-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.14 no.1
    • /
    • pp.44-52
    • /
    • 2007
  • Purpose: This study was done to investigate the effect of Tai Chi Qigong exercise program on insulin resistance and blood glucose in patients with type 2 diabetes. Method: This was a quasi-experimental study used a non-equivalent control group pretest-posttest design. Participants included 39 patients with type 2 diabetes mellitus patients (ages between 40-70)(experimental group, 19, control group, 20). The Tai Chi Qigong exercise program consisted of 5 minute warming up, 30-minute main exercise, and 5 minute cooling down, and was conducted twice a week for 10 weeks. The outcome variables were insulin resistance (proinsulin, C-peptide, insulin, insulin sensitivity index) and blood glucose (fasting, post prandial 2hr, HbA1c). Data was analyzed using ANCOVA, with pre-test values as covariates, to examine difference between pre and post measures between the two groups. Results: The Tai Chi Qigong was effective in lowering postprandial 2hr blood glucose. Conclusion: Twice a week 10 week-Tai Chi Qigong exercise seems to be too short to improve insulin excretion or resistance, and fasting blood sugar and HbA1C in patients with type 2 DM. A Tai Chi Qigong program at least 3 times per week or longer is recommended.

  • PDF