• 제목/요약/키워드: penetration resistance

검색결과 758건 처리시간 0.168초

End shape and rotation effect on steel pipe pile installation effort and bearing resistance

  • Saleem, Muhammad A.;Malik, Adnan A.;Kuwano, Jiro
    • Geomechanics and Engineering
    • /
    • 제23권6호
    • /
    • pp.523-533
    • /
    • 2020
  • The current study focuses on the effect of the end shape of steel pipe piles on installation effort and bearing resistance using the pressing method of installation under dense ground conditions. The effect of pile rotation on the installation effort and bearing resistance is also investigated. The model steel piles with a flat end, cone end and cutting-edge end were used in this study. The test results indicated that cone end pile with the pressing method of installation required the least installation effort (load) and showed higher ultimate resistance than flat and cutting-edge end piles. However, pressing and rotation during cutting-edge end pile installation considerably reduces the installation effort (load and torque) if pile penetration in one rotation equal to the cutting-edge depth. Inclusion of rotation during pile installation reduces the ultimate bearing resistance. However, if penetration of the cutting-edge end pile equal to the cutting-edge depth in one rotation, the reduction in ultimate resistance can be minimized. In comparing the cone and cutting-edge end piles installed with pressing and rotation, the least installation effort is observed in the cutting-edge end pile installed with penetration rate equal to the cutting-edge depth per rotation.

Molecular Dynamic Simulation for Penetration of Carbon Nanotubes into an Array of Carbon Nnantotubes

  • Jang, Ilkwang;Jang, Yong Hoon
    • Tribology and Lubricants
    • /
    • 제36권5호
    • /
    • pp.290-296
    • /
    • 2020
  • When two layers of carbon nanotube (CNT) arrays are loaded to mate, the free ends of individual CNTs come into contact at the interface of the two layers. This leads to a higher contact resistance due to a smaller contact region. However, when the free CNT ends of one array penetrate into the mating array, the contact region increases, effectively lowering the contact resistance. To explore the penetration of mating CNTs, we perform molecular dynamic simulations of a simple unit cell model, incorporating four CNTs in the lower array layer coupled with a single moving CNT on the upper layer. The interaction with neighboring CNTs is modelled by long-range carbon bond order potential (LCBOP I). The model structure is optimized by energy minimization through the conjugate gradient method. A NVT ensemble is used for maintain a room temperature during simulation. The time integration is performed through the velocity-Verlet algorithm. A significant vibrational motion of CNTs is captured when penetration is not available, resulting in a specific vibration mode with a high frequency. Due to this vibrational behavior, the random behaviors of CNT motion for predicting the penetration are confirmed under the specific gap distances between CNTs. Thus, the probability of penetration is examined according to the gap distance between CNTs in the lower array and the aspect ratio of CNTs. The penetration is significantly affected by the vibration mode due to the van der Waals forces between CNTs.

하이브리드 복합재료의 고속충격 저항성에 관한 연구 (A Study on the high velocity impact resistance of hybrid composite materials)

  • 손세원;김희재;김영태
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.273-278
    • /
    • 2003
  • Recently, high-performance hybrid composite materials have been used for various industrial fields because of their superior high strength, high stiffness and lower weight. In this study, manufactured hybrid composite materials are composed of two parts. One is hard-anodized Al5083-O alloy as a face material and the other is high strength aramid fiber ($Twaron^{(R)}$ CT709) laminates as a back-up material. Resistance to penetration is determined by protection ballistic limit($V_{50}$, a static velocity with 50% probability for complete penetration) test method. $V_{50}$ tests with $0^{\circ}$obliquity at room temperature were conducted with 5.56mm ball projectiles that were able to achieve near or complete penetration during high velocity impact tests.

  • PDF

음이온교환수지 혼입 시멘트 모르타르의 압축강도 및 염소이온 침투 저항성에 관한 실험적 연구 (An Experimental Study on the Compressive Strength and Chloride ion penetration resistance of Cement Mortar mixing Anion Exchange Resin)

  • 정도현;이윤수;이한승
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 추계 학술논문 발표대회
    • /
    • pp.23-24
    • /
    • 2018
  • Reinforced concrete is a building material that is generally used in modern society. Also, reinforced concrete structures in high salinity environments have low durability due to corrosion of reinforcing bars due to infiltrated chlorine ions. Anion exchange resins have an ability to immobilize chlorine ions in the resin while releasing their anions. As a material, it has already been shown that it is possible to fix the chloride ion inside the cementitious material through the cement mortar experiment. The purpose of this study is to confirm the compressive strength of cement mortar using powdered anion exchange resin after powdering an anion exchange resin. In order to confirm the chloride ion fixation ability of the powder anion exchange resin, chlorine ion penetration resistance test was carried out.

  • PDF

CGS 잔골재를 사용한 콘크리트의 응결시간 추정시 듀로미터 사용 가능성 분석 (Estimation of Setting Time for Concrete Using CGS Fine Aggregate and Analysis of Durometer)

  • 이혁주;한준희;백승복;신용섭;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.118-119
    • /
    • 2019
  • In this study, we compared the proctor penetration resistance test value of the concrete using CGS for Fine Aggregate and the hardness value of the Durometer. The results are summarized as follows. 1) Surface finish The Durometer C type setting time measurement value was about 45 HD, and the hardness value of the Durometer D type was about 5HD. 2) The proctor penetration resistance test value and the hardness value of the Durometer are highly correlated and are expected to be easy to use.

  • PDF

CGS를 잔골재로 활용하는 FA치환 콘크리트의 응결시간 추정시 개량형 듀로미터 사용 가능성 분석 (Utilization of Improved Durometer when Estimating Setting Time of FA Replacement Concrete Using CGS for Fine Aggregate)

  • 이혁주;신용섭;서항구;한인덕;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.81-82
    • /
    • 2019
  • In this study, the Proctor penetration resistance test value and the hardness value of the improved Durometer were compared and analyzed for the change in the FA replacement rate of the concrete using CGS fine aggregate. The results are summarized as follows. It is. 1) The Proctor penetration resistance test value and the hardness value of the improved Durometer showed a high correlation in the form of a curve. 2) About surface finish Super-resolution with the improved Durometer is considered to be useful when using about 50 HD and about 80 HD in the end to determine the surface finishing work time.

  • PDF

Theoretical resistance in cylindrical electrodes with conical tip

  • Hong, Chang-Ho;Kim, Jin-Seop;Chong, Song-Hun
    • Geomechanics and Engineering
    • /
    • 제30권4호
    • /
    • pp.337-343
    • /
    • 2022
  • The electrical resistivity method is a well-known geophysical method for observing underground conditions, (such as anomalies) and the properties of soil and rock (such as porosity, saturation, and pore fluid characteristics). The shape of electrodes used in an electrical resistivity survey depends on the purpose of the survey and installation conditions. Most electrodes for field applications are cylindrical for sufficient contact with the ground, while some are conically sharpened at their tips for convenient penetration. Previous study only derived theoretical equations for rod-shaped electrodes with spherical tips. In this study, the theoretical resistance for two cylindrical electrodes with conical tips is derived and verified experimentally. The influence of the penetration depth and tip on the measurement is also discussed.

개량형 Durometer를 이용한 고강도 콘크리트의 응결시간 추정 가능성 분석 (A Study on the Estimation of Setting Time for High Strength Concrete Using Durometer)

  • 신세준;한수환;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2020
  • The purpose of this study is to explore the possibility of estimating optimum surface finish time of the fresh concrete placed at the job site by applying a surface hardness test meter(Durometer). Tests are carried out by measuring and comparing the Penetration resistance test and hardness test by Durometer. Penetration resistance tester and improved Durometer are similar, but the higher the temperature, the higher the setting time, and the higher the correlation was shown. When the hardness value of the improved Durometer is about 50 HD, it is found that the initial and 80 HD represent the end. It is expected that this will be useful in determining the finish time of the surface at the actual site.

  • PDF

개량형 Durometer를 이용한 콘크리트의 응결시간 추정 가능성 분석 (A Study on the Estimation of Setting Time for Concrete Using Durometer)

  • 신세준;한수환;현승용;김종;한민철;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.169-170
    • /
    • 2020
  • The purpose of this study is to explore the possibility of estimating optimum surface finish time of the fresh concrete placed at the job site by applying a surface hardness test meter(Durometer). Tests are carried out by measuring and comparing the Penetration resistance test and hardness test by Durometer. Penetration resistance tester and improved Durometer are similar, but the higher the temperature, the higher the setting time, and the higher the correlation was shown. When the hardness value of the improved Durometer is about 50 HD, it is found that the initial and 80 HD represent the end. It is expected that this will be useful in determining the finish time of the surface at the actual site.

  • PDF

물시멘트비가 다른 원전 콘크리트의 염화물 침투저항성 비교평가 (Comparison and Evaluation of Chloride Penetration Resistance in Nuclear Power Plant Concrete with Different Water-to-Cement Ratios)

  • 손정진;김지현;정철우
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.315-316
    • /
    • 2023
  • In the present investigation, the chloride ion penetration resistance of nuclear power plant concrete with varying water-to-cement ratios was assessed. A comparative analysis was conducted on concretes that do not incorporate supplementary cementitious materials, such as fly ash, using permanently decommissioned nuclear structures as a reference. The objective is to employ this acquired data as a fundamental resource for the evaluation of the residual service life of nuclear power plant structures in subsequent studies.

  • PDF