• Title/Summary/Keyword: pelvis

Search Result 778, Processing Time 0.023 seconds

Plan-Class Specific Reference Quality Assurance for Volumetric Modulated Arc Therapy

  • Rahman, Mohammad Mahfujur;Kim, Chan Hyeong;Kim, Seonghoon
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.32-42
    • /
    • 2019
  • Background: There have been much efforts to develop the proper and realistic machine Quality Assurance (QA) reflecting on real Volumetric Modulated Arc Therapy (VMAT) plan. In this work we propose and test a special VMAT plan of plan-class specific (pcsr) QA, as a machine QA so that it might be a good solution to supplement weak point of present machine QA to make it more realistic for VMAT treatment. Materials and Methods: We divided human body into 5 treatment sites: brain, head and neck, chest, abdomen, and pelvis. One plan for each treatment site was selected from real VMAT cases and contours were mapped into the computational human phantom where the same plan as real VMAT plan was created and called plan-class specific reference (pcsr) QA plan. We delivered this pcsr QA plan on a daily basis over the full research period and tracked how much MLC movement and dosimetric error occurred in regular delivery. Several real patients under treatments were also tracked to test the usefulness of pcsr QA through comparisons between them. We used dynalog file viewer (DFV) and Dynalog file to analyze position and speed of individual MLC leaf. The gamma pass rate from portal dosimetry for different gamma criteria was analyzed to evaluate analyze dosimetric accuracy. Results and Discussion: The maxRMS of MLC position error for all plans were all within the tolerance limit of < 0.35 cm and the positional variation of maxPEs for both pcsr and real plans were observed very stable over the research session. Daily variations of maxRMS of MLC speed error and gamma pass rate for real VMAT plans were observed very comparable to those in their pcsr plans in good acceptable fluctuation. Conclusion: We believe that the newly proposed pcsr QA would be useful and helpful to predict the mid-term quality of real VMAT treatment delivery.

Effects of Sagittal Spinopelvic Alignment on Motor Symptom and Respiratory Function in Mild to Moderate Parkinson's disease

  • Kang, DongYeon;Cheon, SangMyung;Son, MinJi;Sung, HyeRyun;Lee, HyeYoung
    • The Journal of Korean Physical Therapy
    • /
    • v.31 no.2
    • /
    • pp.122-128
    • /
    • 2019
  • Purpose: This study examined the effects of sagittal spinopelvic alignment on the clinical parameters, motor symptoms, and respiratory function in patients with mild to moderate Parkinson's disease (PD). Methods: This study was a prospective assessment of treated patients (n=28, Hoehn and Yahr (H&Y) stage 2-3) in a PD center. Twenty-eight subjects ($68.5{\pm}5.7yrs$) participated in this study. The clinical and demographic parameters, including age, sex, symptoms duration, treatment duration, and H&Y stage, were collected. Kinematic analysis was conducted in the upright standing posture with a motion capture system. A pulmonary function test (PFT) was performed in the sitting position using a spirometer. The motor symptoms were assessed on part III of the movement disorder society sponsored version of the unified Parkinson's disease rating scale (MDS-UPDRS). SPSS 18.0 was used to analyze the collected data. Results: The exceeding 12 degrees group of the lower trunk showed significantly higher on the clinical parameters than the below 12 degrees group. In addition, the exceeding 12 degrees group of the lower trunk showed a significantly lower forced expiratory volume at one second (FEV1) / forced vital capacity (FVC) (%) and 25-75% forced mid-expiratory flow (FEF) (L/s) than in the below group. On the other hand, there was no difference in the upper trunk and the cervical pelvis between the groups. Conclusion: These findings suggest that the sagittal balance in the lower trunk is related to the clinical parameters and respiratory function, but not the motor symptoms in patients with mild to moderate PD.

Understanding and Exercise of Gluteus Medius Weakness: A Systematic Review

  • Baik, Seung-min;Cynn, Heon-seock;Kim, Seok-hyun
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.27-35
    • /
    • 2021
  • A weak or dysfunctional gluteus medius (Gmed) is related to several pathologies, and individuals with hip abductor weakness have Gmed weakness. This study aimed to systematically review the literature associated with the anatomy and function of the Gmed, and the prevalence, pathology, and exercise of Gmed weakness. Papers published between 2010 and 2020 were retrieved from MEDLINE, Google Academic Search, and Research Information Sharing Service. The database search used the following terms: (glut* OR medius OR hip abduct*) AND weak*. The Gmed plays an important role in several functional activities as a primary hip abductor by providing pelvic stabilization and controlling hip adduction and internal rotation. Weakness of the Gmed is associated with many disorders including balance deficit, gait and running disorders, femoroacetabular impingement, snapping hip, gluteal tendinopathy, patellofemoral pain syndrome, osteoarthritis, iliotibial band syndrome, anterior cruciate ligament injury, ankle joint injuries, low back pain, stroke, and nocturia. Overuse of the tensor fasciae latae (TFL) as a hip abductor due to Gmed weakness can also cause several pathologies such as pain in the lower back and hip and degenerative hip joint pathology, which are associated with dominant TFL. Similarly, lateral instability and impaired movements such as lumbar spine lateral flexion or lateral tilt of the pelvis can occur due to compensatory activation of the quadratus lumborum for a weakened Gmed while exercising. Therefore, the related activation of synergistic muscles or compensatory movement should be considered when prescribing Gmed strengthening exercises.

Associated Injuries in Spine Trauma Patients: A Single-Center Experience

  • Yu, Seunghan;Choi, Hyuk Jin;Lee, Jung Hwan;Kim, Byung Chul;Ha, Mahnjeong;Han, In Ho
    • Journal of Trauma and Injury
    • /
    • v.33 no.4
    • /
    • pp.242-247
    • /
    • 2020
  • Purpose: The purpose of this study was to determine the incidence and characteristics of associated injuries in patients with spine trauma. Methods: Data of 3,920 consecutive patients admitted to a regional trauma center during a 3-year period were analyzed retrospectively. Results: Of the 3,920 patients who were admitted to the trauma center during the 3-year study period, 389 (9.9%) had major spinal injuries. Among these 389 patients, 303 (77.9%) had associated injuries outside the spine. The most common body region of associated injuries was the extremities or pelvis (194 cases, 49.4%), followed by the chest (154 cases, 39.6%) and face (127 cases, 32.6%). Of these 303 patients, 149 (64%) had associated injuries that required surgical treatment such as laparotomy or internal fixation. Associated injuries were more common in patients with lumbar injuries (93.3%) or multiple spinal injuries (100%) than in those with lower cervical injuries (67.4%). There was a significant correlation between the location of the spinal injury and the body region of the associated injury. However, distant associated injuries were also common. Conclusions: Associated injuries were very common in spinal injury patients. Based on demographic groups, the trauma mechanism, and the location of spinal injury, an associated injury should be suspected until proven otherwise. Using a multidisciplinary and integrated approach to treat trauma victims is of the paramount importance.

Effect of High-frequency Diathermy on Hamstring Tightness

  • Kim, Ye Jin;Park, Joo-Hee;Kim, Ji-hyun;Moon, Gyeong Ah;Jeon, Hye-Seon
    • Physical Therapy Korea
    • /
    • v.28 no.1
    • /
    • pp.65-71
    • /
    • 2021
  • Background: The hamstring is a muscle that crosses two joints, that is the hip and knee, and its flexibility is an important indicator of physical health in its role in many activities of daily living such as sitting, walking, and running. Limited range of motion (ROM) due to hamstring tightness is strongly related to back pain and malfunction of the hip joint. High-frequency diathermy (HFD) therapy is known to be effective in relaxing the muscle and increasing ROM. Objects: To investigate the effects of HFD on active knee extension ROM and hamstring tone and stiffness in participants with hamstring tightness. Methods: Twenty-four participants with hamstring tightness were recruited, and the operational definition of hamstring tightness in this study was active knee extension ROM of below 160° at 90° hip flexion in the supine position. HFD was applied to the hamstring for 15 minutes using the WINBACK device. All participants were examined before and after the intervention, and the results were analyzed using a paired t-test. The outcome measures included knee extension ROM, the viscoelastic property of the hamstring, and peak torque for passive knee extension. Results: The active knee extension ROM significantly increased from 138.8° ± 9.9° (mean ± standard deviation) to 143.9° ± 10.4° after the intervention (p < 0.05), while viscoelastic property of the hamstring significantly decreased (p < 0.05). Also, the peak torque for knee extension significantly decreased (p < 0.05). Conclusion: Application of HFD for 15 minutes to tight hamstrings immediately improves the active ROM and reduces the tone, stiffness, and elasticity of the muscle. However, further experiments are required to examine the long-term effects of HFD on hamstring tightness including pain reduction, postural improvement around the pelvis and lower extremities, and enhanced functional movement.

Two Measurement Considerations for Counting of Background Radioactivity using the Thigh during Thyroid Uptake Rate Test (갑상샘 섭취율 검사 시 대퇴부를 이용한 배후방사능 계측을 위한 2가지 측정 고찰)

  • Do, Yongho;Cho, Youngkwon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.533-538
    • /
    • 2021
  • 99mTcO4- is used to measure thyroid uptake. When measuring background radioactivity of the thigh, the distance between the detector and the thigh was 20 cm at a position 10 cm above the knee from the knee to the pelvis. At 25 cm, many hospitals are measuring at different distances. The purpose of this study was to study the difference in effectiveness in obtaining the thyroid uptake rate by quantitatively analyzing the uptake rate measurement at two distances. As a result, the average thyroid uptake rate measured at 20 cm in the thigh of 50 patients was 3.532±4.312%, and the average thyroid uptake rate measured at 25 cm was 3.680±4.304%. As a result of the thyroid uptake rate test result, the femoral background radioactivity value measured at a distance of 20 cm was relatively higher than the background radioactivity value measured at a distance of 25 cm, and as a result, the thyroid uptake rate was 0.148% lower.

Fall Detection Based on 2-Stacked Bi-LSTM and Human-Skeleton Keypoints of RGBD Camera (RGBD 카메라 기반의 Human-Skeleton Keypoints와 2-Stacked Bi-LSTM 모델을 이용한 낙상 탐지)

  • Shin, Byung Geun;Kim, Uung Ho;Lee, Sang Woo;Yang, Jae Young;Kim, Wongyum
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.10 no.11
    • /
    • pp.491-500
    • /
    • 2021
  • In this study, we propose a method for detecting fall behavior using MS Kinect v2 RGBD Camera-based Human-Skeleton Keypoints and a 2-Stacked Bi-LSTM model. In previous studies, skeletal information was extracted from RGB images using a deep learning model such as OpenPose, and then recognition was performed using a recurrent neural network model such as LSTM and GRU. The proposed method receives skeletal information directly from the camera, extracts 2 time-series features of acceleration and distance, and then recognizes the fall behavior using the 2-Stacked Bi-LSTM model. The central joint was obtained for the major skeletons such as the shoulder, spine, and pelvis, and the movement acceleration and distance from the floor were proposed as features of the central joint. The extracted features were compared with models such as Stacked LSTM and Bi-LSTM, and improved detection performance compared to existing studies such as GRU and LSTM was demonstrated through experiments.

Effects of Pilates Reformer Core and Mat Core Exercises on Standing Posture Alignment

  • Sim, Gyeongseop;Kim, Donghoon;Jeon, Hyeseon
    • Physical Therapy Korea
    • /
    • v.29 no.4
    • /
    • pp.282-288
    • /
    • 2022
  • Background: Pilates exercises are used for body shape correction because they can achieve correct posture alignment through spinal stabilization. Objects: This study aimed to determine whether the use of reformers increases the effectiveness of Pilates core exercises on body alignment in standing. Methods: The study included 30 women without known diagnoses of musculoskeletal and neurological disorders or cancer. Those who had taken more than 10 Pilates lessons were excluded. The participants were randomly assigned to either the reformer exercise group or the mat exercise group, and interventional Pilates exercises were performed for 60 minutes a day, three times a week, for a total of 8 weeks. Ten movements of the reformer and mat Pilates core exercise programs were included. Exbody® 9100 MOMI musculoskeletal analysis equipment (Exbody Inc.) was used to assess the alignment of the standing posture in the frontal plane. Results: As a result of comparing the differences within and between the groups before and after the intervention using the two-way mixed analysis of variance test, height differences in the head, pelvis, left and right, shoulders, scapulas, knees, and ankles in the frontal plane after the intervention were found in both groups. For example, the left-right symmetry of the body alignment in the standing posture was significantly improved within each group (p < 0.05). However, no significant difference was found between the groups (p > 0.05). Conclusion: Both the reformer and mat Pilates core exercises were effective for standing posture alignment, which has clinical significance. If an exercise program is developed based on the analysis of movements necessary for posture improvement and the target muscles to be strengthened, the same effect can be achieved only with mat exercise without using the reformer equipment at the beginner stage.

The Relationship Between Hip Abductor and Pelvic Drop During Lateral Step Down in the Elderly

  • Lee, Young-kwon;Jung, Sung-hoon;Yoo, Hwa-ik;Kwon, Oh-yun
    • Physical Therapy Korea
    • /
    • v.29 no.4
    • /
    • pp.249-254
    • /
    • 2022
  • Background: The lateral step down (LSD) is a form of stair negotiation used by the elderly because it requires less movement of the lower extremity. Although it is necessary to study the amount of pelvic drop and the strength of a hip abductor during LSD for intervention, limited studies have investigated the relationship between the amount of pelvic drop and strength of a hip abductor during LSD in elderly people. Objects: This study aimed to determine the relationship between the amount of pelvic drop on an unsupported leg and the strength of the hip abductor during LSD in the elderly. Methods: Thirty elderly people (male: 17, female: 13) were recruited. Subjects performed the LSD task, and the evaluator measured and the amount of pelvic drop on an unsupported side. Also, the isometric strength of the hip abductor was measured in a supine position. Results: We found significant relationships between the strength of the hip abductor and the amount of pelvic drop (r = -0.386). The average hip abductor strength normalized by body weight was 1.06 N/kg (max: 1.99, min: 0.52) and the average contralateral pelvic drop (CPD) angle was 4.16° (max: 15.3, min: 0). Conclusion: Our results indicated that the strength of the hip abductor had a moderate correlation with the CPD during a LSD in the elderly. Hip abductor weakness could translate into altered movement of the pelvis.

Management of a traumatic anorectal full-thickness laceration: a case report

  • Fortuna, Laura;Bottari, Andrea;Somigli, Riccardo;Giannessi, Sandro
    • Journal of Trauma and Injury
    • /
    • v.35 no.3
    • /
    • pp.215-218
    • /
    • 2022
  • The rectum is the least frequently injured organ in trauma, with an incidence of about 1% to 3% in trauma cases involving civilians. Most rectal injuries are caused by gunshot wounds, blunt force trauma, and stab wounds. A 46-year-old male patient was crushed between two vehicles while he was working. He was hemodynamically unstable, and the Focused Assessment with Sonography for Trauma showed hemoperitoneum and hemoretroperitoneum; therefore, damage control surgery with pelvic packing was performed. A subsequent whole-body computed tomography scan showed a displaced pelvic bone and sacrum fracture. There was evidence of an anorectal full-thickness laceration and urethral laceration. In second-look surgery performed 48 hours later, the pelvis was stabilized with external fixators, and it was decided to proceed with loop sigmoid colostomy. A tractioned rectal probe with an internal balloon was positioned in order to approach the flaps of the rectal wall laceration. On postoperative day 13, a radiological examination with endoluminal contrast injected from the stoma after removal of the balloon was performed and showed no evidence of extraluminal leak. Rectosigmoidoscopy, rectal manometry, anal sphincter electromyography, and trans-stomic transit examinations showed normal findings, indicating that it was appropriate to proceed with the closure of the colostomy. The postoperative course was uneventful. The optimal management for extraperitoneal penetrating rectal injuries continues to evolve. Primary repair with fecal diversion is the mainstay of treatment, and a conservative approach to rectal lacerations with an internal balloon in a rectal probe could provide a possibility for healing with a lower risk of complications.