• Title/Summary/Keyword: pedal

Search Result 211, Processing Time 0.025 seconds

The Effect of the Heel Rest on Braking Reaction Time while Driving Vehicle with Automatic Transmission (오토 차량 운전시 보조 발판이 제동 시간에 미치는 영향)

  • Kim, Jeong-Ryong;Jo, Yeong-Jin;Park, Ji-Su;Seo, Gyeong-Bae
    • Journal of Korean Society of Transportation
    • /
    • v.24 no.1 s.87
    • /
    • pp.53-58
    • /
    • 2006
  • The purpose of this study was to test the safety of the heel rest which was made for reducing the automobile driver's muscle fatigue with automatic transmission. Sixty subjects participated in the test, including ten males and ten females in 30s, 40s, 50s, respectively. Simulator consisted of automobile cockpit, accelerator and brake pedal sensor, heel rest. and driving displays. 30 seconds were given to subjects to be accustomed to the simulator environment. They also had one pre-trial to use the brake pedal according to the experimental scenario. They were told to step on the brake pedal immediately as soon as the red light was on the display The reaction time representing the foot travel time between accelerator and brake pedal was measured with/without the heel rest. In results, there was no significant difference in reaction time between conditions with/without heel rest. The result indicated that the heel rest used in this study would be a safe accessory for drivers who need to reduce the fatigue of the muscle or joint during driving.

Effect of Saddle to Pedal Length in Kayak Ergometer on Rowing Motion and EMG Activation in Elite Kayak Players (엘리트 카약 선수들의 에르고미터를 이용한 로잉 동작 시 안장과 페달의 거리가 로잉 패턴 및 근 활성도에 미치는 영향)

  • Ryue, Jae-Jin;Nam, Ki-Jung;Lee, Chong-Hoon
    • Korean Journal of Applied Biomechanics
    • /
    • v.22 no.1
    • /
    • pp.65-73
    • /
    • 2012
  • The purpose of this study was to identify the saddle to pedal length contributing to successful performance in kayak using a kayak ergometer. Ten male elite kayak players participated in this study. players were tested on the kayak ergometer which was varied saddle to pedal length by the knee flexion angle(90deg; 120deg; 150deg) to measure stroke frequency, paddling amplitude, joint angle, RoM and angular velocity, foot pressure and force, iEMG using the 3D motion system, foot pressure system and EMG wireless system. At a results, rowing at 120deg on knee flexion angle showed higher stroke frequency and paddling amplitude than other knee flexion angles. RoM at upper extremity showed not significant difference between knee flexion angles. But there were significant differences in thorax and pelvis rotation RoM, knee flexion-extension RoM in each condition. In addition, foot pressure, force and iEMG were significantly different in knee flexion angles. Study showed that changed of saddle to pedal length affected rowing performance kinds of stroke frequency, paddling amplitude. The most important thing, increased range of motion in pelvic and thorax has occurred by force that generated foot-bar to seat. Not only that, but it seems to be attributed to a technical adaptation developed to maximum rowing performance.

Saddle Height Determination by Effectiveness of Pedal Reaction Force during Cycle Pedaling (사이클 페달링 시 페달반력 효율성을 고려한 적정 안장높이 결정방법)

  • Bae, Jae-Hyuk;Seo, Jeong-Woo;Kang, Dong-Won;Choi, Jin-Seung;Tack, Gye-Rae
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.417-423
    • /
    • 2014
  • The purpose of this study was to compare two saddle height determination methods by the effectiveness of pedal reaction force. Ten male subjects (age: $24.0{\pm}2.4years$, height: $175.1{\pm}5.4cm$, weight: $69.3{\pm}11.1kg$, inseam: $77.8{\pm}4.5cm$) participated in three minutes, 60 rpm cycle pedaling tests with the same load and cadence. Subject's saddle height was determined by $25^{\circ}$ knee flexion angle (K25) when the pedal crank was at the 6 o'clock position (knee angle method) and 97% (T97), 100% (T100), 103% (T103) of trochanter height (trochanteric method). The RF (resultant force), EF (effective force), and IE (index of effectiveness) were compared by measuring 3D motion and 3-axis pedal reaction force data during 4 pedaling phases (phase1: $330^{\circ}-30^{\circ}$, phase2: $30^{\circ}-150^{\circ}$, phase3: $150^{\circ}-210$, phase4: $210^{\circ}-330^{\circ}$). Results showed that there were significant differences in EF at phase1 between T97 and K25, in EF at phase4 between T100 and T103, in IE at total phase between T97 and K25, between T100 and T103, in IE at phase1 & phase2 between T97 and K25. There was higher IE in the K25 than any other saddle heights, which means that K25 was better pedaling effectiveness than the trochanteric method. Therefore it was suggested the saddle height as 103.7% of trochanter height that converted from K25.

Evaluation of Electronic Pedal in Commercial Vehicles using Physiology Analysis of Electromyography (근전도 생리 분석을 이용한 상용차용 전자페달의 평가)

  • Kim, Jae-Jun;Kim, Kyung;Shin, Sun-Hye;Yu, Chang-Ho;Jeong, Gu-Young;Oh, Seung-Yong;Kwon, Tae-Kyu
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.12
    • /
    • pp.1434-1440
    • /
    • 2011
  • In this paper, we assessed muscular activities of lower limbs and foot pressure for car and bus drivers according to operating three electronic pedals that we developed. To analyze drivers' physical exhaustion, muscular fatigue of lower limbs was evaluated. Eleven car drivers and six urban bus drivers were participated in this experiment. The virtual driving system was used for the real driving environment. The virtual driving system was comprised of a spring seat, a steering wheel, pedals (clutch, excel and brake pedals), a manual transmission and a virtual driving simulation. For the real vibration like situation on the road, six degree of freedom motion base system was used. Measured muscles were rectus femoris (RF), biceps femoris (BF), tibialis anterior (TA) and gastrocnemius (Gn) muscles. For the quantitative muscular activities, integrated electromyography (IEMG) was analyzed. Muscular fatigues also were analyzed through the analysis of the median frequency. In addition, foot pressures were analyzed and compared through the peak and averaged pressure during the operating three developed electronic pedals. The experiments are conducted with total 17 drivers, 11 general public and 6 drivers. As a result of the analysis, electromyogram and fatigue analysis through intermediate frequency reduction for pedal-1 more efficient than other pedals. And foot pressure also was decreased. Consequently, we suggested the most efficient pedal and method to minimize the amount of cumulative fatigue.

Histochemistry of Mucosubstances on the Pedal Sole of Five Abalone Species

  • Chu Lee;Dae Yeon Moon;Young Ju Lee;Byung Tae Choi
    • Animal cells and systems
    • /
    • v.3 no.3
    • /
    • pp.253-258
    • /
    • 1999
  • The present study describes histochemical properties of the mucosubstances in the pedal sole of abalone, in relation to two main additional functions known to date. Only neutral mucosubstances were demonstrated in the lateral epithelium of the pedal sole of the abalone, however, two distinct types of cells, one containing neutral and the other containing acidic mucosubstances, were identified in the ventral epithelium. The epithelial mucocytes distributed throughout both epithelial and subepithelial glands located in the ventral subepithelial region showed a mixture of neutral and acidic mucosubstances. However, acidic mucosubstances were found in larger amounts than neutral ones in epithelial mucocytes, and vice versa in subepithelial glands. Among these acidic mucosubstances, sulphated substances were dominant. Lesser amounts of carboxylated substances also occurred together with low levels of neuramic and sialic acid. Collectively, the notable morphological differences between abalone and other gastropoda were observed in the ventral surface of the foot, which showed a tall columnar epithelium, peripherally concentrated mucocytes, and subepithelial glands. Mucosubstances are presumably produced by these cells and may also play a role in clinging to some substances to support abalones in addition to the main functions of lubrication and protection.

  • PDF

Nonlinear Identification of Electronic Brake Pedal Behavior Using Hybrid GMDH and Genetic Algorithm in Brake-By-Wire System

  • Bae, Junhyung;Lee, Seonghun;Shin, Dong-Hwan;Hong, Jaeseung;Lee, Jaeseong;Kim, Jong-Hae
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.3
    • /
    • pp.1292-1298
    • /
    • 2017
  • In this paper, we represent a nonlinear identification of electronic brake pedal behavior in the brake-by-wire (BBW) system based on hybrid group method of data handling (GMDH) and genetic algorithm (GA). A GMDH is a kind of multi-layer network with a structure that is determined through training and which can express nonlinear dynamics as a mathematical model. The GA is used in the GMDH, enabling each neuron to search for its optimal set of connections with the preceding layer. The results obtained with this hybrid approach were compared with different nonlinear system identification methods. The experimental results showed that the hybrid approach performs better than the other methods in terms of root mean square error (RMSE) and correlation coefficients. The hybrid GMDH/GA approach was effective for modeling and predicting the brake pedal system under random braking conditions.

Usefulness of 3-Dimensional Gadolinium-enhanced MR Angiography for the Evaluation of Pedal Artery. : Comparison with digital subtraction angiography (족부혈관 평가에 있어서의 3차원 Gadolinium 조영증강 자기공명혈관조영술의 유용성 : 디지털 감산 혈관조영술과의 비교)

  • Ji, Youn-Sang;Lee, Bong-Jae
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.23-28
    • /
    • 2001
  • The purpose of this study is to compare the 3-dimensional MR angiography(MRA) with digital subtraction angiography(DSA) for the evaluation of pedal artery. MR angiography was performed using three-dimensional FISP acquisition before, and four sequential acquisitions after the injection of gadolinium(0.2 mmol/kg, 3 ml/sec). MRA was compared with DSA for a correct identification of the arterial segment. Out of 168 segments, 32 segmints were invisible in both MRA and DSA. At the level of ankle, 48 segments were visible in both examinations, and 18 segments were visible only in MRA. In the foot area, 34 segments were visible in MRA, but not in DSA. Three arterial segments were visible only in DSA. 3D MRA is comparable to DSA for the evaluation of pedal artery, thus it gives additional Information for the planning of treatment in lower extremity artery.

  • PDF

Two dimensional tin sulfide for photoelectric device

  • Patel, Malkeshkumar;Kim, Joondong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.389.1-389.1
    • /
    • 2016
  • The flexible solid state device has been widely studied as portable and wearable device applications such as display, sensor and curved circuits. A zero-bias operation without any external power consumption is a highly-demanding feature of semiconductor devices, including optical communication, environment monitoring and digital imaging applications. Moreover, the flexibility of device would give the degree of freedom of transparent electronics. Functional and transparent abrupt p/n junction device has been realized by combining of p-type NiO and n-type ZnO metal oxide semiconductors. The use of a plastic polyethylene terephthalate (PET) film substrate spontaneously allows the flexible feature of the devices. The functional design of p-NiO/n-ZnO metal oxide device provides a high rectifying ratio of 189 to ensure the quality junction quality. This all transparent metal oxide device can be operated without external power supply. The flexible p-NiO/n-ZnO device exhibit substantial photodetection performances of quick response time of $68{\mu}s$. We may suggest an efficient design scheme of flexible and functional metal oxide-based transparent electronics.

  • PDF

ENGINE CONTROL USING SPEED FEEDBACK

  • Stotsky, A.;Solyom, S.;Kolmanovsky, I.V.
    • International Journal of Automotive Technology
    • /
    • v.8 no.4
    • /
    • pp.477-481
    • /
    • 2007
  • In this article we present a new, reference model based, unified strategy for engine control. Three main modes are considered: first is the driver control mode where the driver controls the engine via the pedal position; second is the dashpot mode, that is, when the driver takes his foot off the pedal; and, lastly is the idle speed control mode. These modes are unified so that seamless transitions between modes now becomes possible. The unification is achieved due to the introduction of a reference model for the engine speed whereby only the desired engine speed is different for different modes while the structure of the control system remains the same for all the modes. The scheme includes an observer that estimates unknown engine load torque. A proof of robustness with respect to unknown load disturbances both within the operating modes and during intermode transitions is given.

A biomechanical model of lower extremity for seated operators (착좌시 하지 동작의 생체역학적 모델)

  • 황규성;이동춘;최재호
    • Journal of the Ergonomics Society of Korea
    • /
    • v.11 no.1
    • /
    • pp.81-92
    • /
    • 1992
  • A two-dimensional static biochemical model of lower extremity in the seated posture was developed to assess muscular activities of lower extremity required for a variety of foot pedal operations. We found that the double linear optimization method that has been used for modelling articulated body segments does no predict the forces generated by biarticular muscles reasonably, so the revised double linear optimization scheme was used to consider the synergistic effects of biarticular muscles in our model, assuming that the muscle forces are distributed proportionally based on their physiological cross sectional area. The model incorporated three rigid body se- gments with six muscles to represnet lower extremity. For the model validation, three male subjects performed the experiments in which EMG activities of six lower extremity muscles were measured. Predicted muscle forces were compare with the corresponding EMG amplitudes and it showed no statistical difference. The model being developed can be used to design and assess pedal and foot-related tool design.

  • PDF