• Title/Summary/Keyword: peak value detection

Search Result 137, Processing Time 0.024 seconds

Improvement of Mass Spectral Detection Performance by Pre-correction of Peak Position Error (피크위치오차 사전 보정을 통한 질량 스펙트럼 검출 성능 개선)

  • Lee, Young Hawk;Heo, Gyeongyong;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.6
    • /
    • pp.666-674
    • /
    • 2019
  • In the mass spectrum of the mass spectrometer, the spectrum of the low peak adjacent to the spectrum having the high peak value is connected to each other and thus the separation is difficult. This inter-spectral overlap causes degradation of the mass spectral detection performance and resolution. In this paper, we propose a method to improve the mass spectrum detection performance and peak accuracy of residual gas analyzer. The type discrimination according to the characteristics of the ion signal block and the pre-correction for the peak position error can separate and detect the spectrum of the low peak connected to the adjacent spectra. To verify the performance of the proposed method, we compared the proposed method with the conventional method in simulations using actual ion signals obtained from the mass spectrometer under development.

A readout method using pulse peak-time capture for radiation detectors (펄스의 피크시각 포착을 이용한 방사선 검출기의 신호처리 방법)

  • Kim, Jong-ho;Kwon, Young-mok;Hong, Hyoung-pyo;Che, Gyu-shik
    • Journal of Advanced Navigation Technology
    • /
    • v.21 no.6
    • /
    • pp.651-658
    • /
    • 2017
  • There were many studies on the development of radiation measuring instruments to detect the presence of radiation. In particular, the signal processing method and treatment without loss of the detection signal are very important. The common feature for these studies is the peak-hold method that keeps the peak value of input signal uniform for a short time, readouts its value, discharges electrical value, and then waits for next signal. We propose the new methodology to capture the pulse peak value from the radiation detector and read the value directly other than peak-hold method. This method has merit of accurate reading the input signal pulse peak value without complicate process of holding for a period or initializing of input signal, and then be verified to be adequate through simulation of actual example.

Cable Fault Detection Improvement of STDR Using Reference Signal Elimination (인가신호 제거를 이용한 STDR의 케이블 고장 검출 성능 향상)

  • Jeon, Jeong-Chay;Kim, Taek-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.450-456
    • /
    • 2016
  • STDR (sequence time domain reflectometry) to detect a cable fault using a pseudo noise sequence as a reference signal, and time correlation analysis between the reference signal and reflection signal is robust to noisy environments and can detect intermittent faults including open faults and short circuits. On the other hand, if the distance of the fault location is far away or the fault type is a soft fault, attenuation of the reflected signal becomes larger; hence the correlation coefficient in the STDR becomes smaller, which makes fault detection difficult and the measurement error larger. In addition, automation of the fault location by detection of phase and peak value becomes difficult. Therefore, to improve the cable fault detection of a conventional STDR, this paper proposes the algorithm in that the peak value of the correlation coefficient of the reference signal is detected, and a peak value of the correlation coefficient of the reflected signal is then detected after removing the reference signal. The performance of the proposed method was validated experimentally in low-voltage power cables. The performance evaluation showed that the proposed method can identify whether a fault occurred more accurately and can track the fault locations better than conventional STDR despite the signal attenuation. In addition, there was no error of an automatic fault type and its location by the detection of the phase and peak value through the elimination of the reference signal and normalization of the correlation coefficient.

Wearable Approach of ECG Monitoring System for Wireless Tele-Home Care Application

  • Kew, Hsein-Ping;Noh, Yun-Hong;Jeong, Do-Un
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.05a
    • /
    • pp.337-340
    • /
    • 2009
  • Wireless tele-home-care application gives new possibilities for ECG (electrocardiogram) monitoring system with wearable biomedical sensors. Thus, continuously development of high convenient ECG monitoring system for high-risk cardiac patients is essential. This paper describes to monitor a person's ECG using wearable approach. A wearable belt-type ECG electrode with integrated electronics has been developed and has proven long-term robustness and monitoring of all electrical components. The measured ECG signal is transmitted via an ultra low power consumption wireless sensor node. ECG signals carry a lot clinical information for a cardiologist especially the R-peak detection in ECG. R-peak detection generally uses the threshold value which is fixed thus it bring errors due to motion artifacts and signal size changes. Variable threshold method is used to detect the R-peak which is more accurate and efficient. In order to evaluate the performance analysis, R-peak detection using MIT-BIH databases and Long Term Real-Time ECG is performed in this research. This concept able to allow patient to follow up critical patients from their home and early detecting rarely occurrences of cardiac arrhythmia.

  • PDF

Optimal Threshold Setting Method for R Wave Detection According to The Sampling Frequency of ECG Signals (심전도신호 샘플링 주파수에 따른 R파 검출 최적 문턱치 설정)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1420-1428
    • /
    • 2017
  • It is difficult to guarantee the reliability of the algorithm due to the difference of the sampling frequency among the various ECG databases used for the R wave detection in case of applying to different environments. In this study, we propose an optimal threshold setting method for R wave detection according to the sampling frequency of ECG signals. For this purpose, preprocessing process was performed using moving average and the squaring function based the derivative. The optimal value for the peak threshold was then detected according to the sampling frequency by changing the threshold value according to the variation of the signal and the previously detected peak value. The performance of R wave detection is evaluated by using 48 record of MIT-BIH arrhythmia database. When the optimal values of the differential section, window size, and threshold coefficient for the MIT-BIH sampling frequency of 360 Hz were 7, 8, and 6.6, respectively, the R wave detection rate was 99.758%.

Multi-Modal User Distance Estimation System based on Mobile Device (모바일 디바이스 기반의 멀티 모달 사용자 거리 추정 시스템)

  • Oh, Byung-Hun;Hong, Kwang-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.65-71
    • /
    • 2014
  • This paper present the multi-modal user distance estimation system using mono camera and mono microphone basically equipped with a mobile device. In case of a distance estimation method using an image, we is estimated a distance of the user through the skin color region extraction step, a noise removal step, the face and eyes region detection step. On the other hand, in case of a distance estimation method using speech, we calculates the absolute difference between the value of the sample of speech input. The largest peak value of the calculated difference value is selected and samples before and after the peak are specified as the ROI(Region of Interest). The samples specified perform FFT(Fast Fourier Transform) and calculate the magnitude of the frequency domain. Magnitude obtained is compared with the distance model to calculate the likelihood. We is estimated user distance by adding with weights in the sorted value. The result of an experiment using the multi-modal method shows more improved measurement value than that of single modality.

Improvement of Spectrum Detection Algorithm for Mass Spectrometer (질량분석기를 위한 스펙트럼 검출 알고리즘의 개선)

  • Lee, Young Hawk;Choi, Hun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.1
    • /
    • pp.47-54
    • /
    • 2019
  • An improved method of spectrum detection algorithm for mass spectrum analysis system is proposed. In the conventional spectrum detection algorithm that utilizes the results of the linear approximation and quadratic curve fitting on the ion signal block of each mass index, it is possible to reduce the detection error in the mass spectrum detection by further improving the condition of eliminating the invalid ion signals. Also, the proposed method can reduce the estimation error of the peak value of the mass spectrum by using the result of quadratic curve fitting for the effective ion signal block in which the peak position error is corrected. To evaluate the effectiveness of the proposed method, computer simulations were carried out step by step using the measured ion signal. Also, by comparing the rate of false detection for several inputs, the proposed method showed better detection performance than the conventional method.

Eyebrow Detection Algorithm Using the Histogram Analysis (히스토그램 분석을 이용한 눈썹 검출 알고리즘)

  • 이강호
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.4
    • /
    • pp.46-51
    • /
    • 2002
  • In this paper, I proposed a eyebrow detection algorithm in human face, that is important element in facial recognition. The proposed algorithm consists of four processes: face region detection using color region segmentation. eye detection by template matching, eyebrow candidate region detection in detected eye region, and eyebrow detection by thresholding using the modified histogram that gets luminance value in the candidate region. The test results show that the proposed algorithm can detect eyebrow region very effectively in facial image.

  • PDF

An Enhanced Step Detection Algorithm with Threshold Function under Low Sampling Rate (낮은 샘플링 주파수에서 임계 함수를 사용한 개선된 걸음 검출 알고리즘)

  • Kim, Boyeon;Chang, Yunseok
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.4 no.2
    • /
    • pp.57-64
    • /
    • 2015
  • At the case of peak threshold algorithm, 3-axes data should sample step data over 20 Hz to get sufficient accuracy. But most of the digital sensors like 3-axes accelerometer have very low sampling rate caused by low data communication speed on limited SPI or $I^2C$ bandwidth of the low-cost MPU for ubiquitous devices. If the data transfer rate of the 3-axes accelerometer is getting slow, the sampling rate also slows down and it finally degrades the data accuracy. In this study, we proved there is a distinct functional relation between the sampling rate and threshold on the peak threshold step detection algorithm under the 20Hz frequency, and made a threshold function through the experiments. As a result of experiments, when we apply threshold value from the threshold function instead of fixed threshold value, the step detection error rate can be lessen about 1.2% or under. Therefore, we can suggest a peak threshold based new step detection algorithm with threshold function and it can enhance the accuracy of step detection and step count. This algorithm not only can be applied on a digital step counter design, but also can be adopted any other low-cost ubiquitous sensor devices subjected on low sampling rate.

Detection of Ultrasonic Wave Signals Associated with Partial Discharge in XLPE (가교폴리에틸렌(XLPE)의 부분방전에 의한 초음파 검출)

  • 김성규;이상우;구경철;김충년;김인식;이광식;이동인
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.136-140
    • /
    • 1999
  • Measurements of AE signals caused by partial discharges were performed by using an ultrasonic measurement technique to diagonise the electrical treeing deterioration in XLPE cable. We also examined the partial discharge magnitude and AE signals(peak-to-peak) with the increase of the deterioration time. From these results, it was found that AE signal due to partial discharge can be greatly detected at the peak value of positive polarities prior to the breakdown voltages, and the magnitude of AE signals was closely related to the current pulses by the increase of deterioration, and it appeared that AE signals(peak-to-peak) was proportional to partial discharge magnitude. Attenuation and time-delaying characteristics of ultrasonic signals propagated in various polymers sample by using ultrasonic oscillation and receiving systems are also reported as a basic data of ultrasonic measurements in XLPE cable.

  • PDF