• Title/Summary/Keyword: peak value detection

Search Result 137, Processing Time 0.021 seconds

Separating of Falcarinol from Acanthopanax senticosus (가시오가피(Acanthopanax senticosus)에서 polyacetylene계 화합물인 falcarinol의 동정)

  • Kim, Seong-Ju;Chang, Kyu-Seob
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.360-363
    • /
    • 2005
  • To detect falcarinol in Acanthopanax senticosus, its stem and bark were extracted with methanol fractionated with petroleum ether and diethyl ether, and separated by silica gel column chromatography, Resulting six crude samples were compared with standard falcarinol through TLC on silica gel plates. Fraction 6 showed $R_{f}$ value of 0.46 similar to that of standard falcarinol. Through analytical reverse phase HPLC/PDA, UV spectra of standard falcarinol and traction 6 recorded between 200 and 340 nm showed identical peaks and UV spectra patterns. GC/MS revealed standard falcarinol and fraction 6 have equal retention times of 7.4 and 8.5 min before and after TMS-derivatization, respectively. Standard falcarinol and fraction 6 showed more similar spectrum patterns after TMS-derivatization than before. These results confirm presence of falcarinol in A. senticosus.

Image Watermarking for Identification Forgery Prevention (신분증 위변조 방지를 위한 이미지 워터마킹)

  • Nah, Ji-Hah;Kim, Jong-Weon;Kim, Jae-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.12
    • /
    • pp.552-559
    • /
    • 2011
  • In this paper, a new image watermarking algorithm is proposed which can hide specific information of an ID card's owner in photo image for preventing ID's photo forgery. Proposed algorithm uses the image segmentation and the correlation peak position modulation of spread spectrum. The watermark embedded in photo ensures not only robustness against printing and scanning but also sufficient information capacity hiding unique number such as social security numbers in small-sized photo. Another advantage of proposed method is extracting accurate information with error tolerance within some rotation range by using $2^h{\times}2^w$ unit sample space not instead $1{\times}1$ pixels for insertion and extraction of information. 40 bits information can be embedded and extracted at $256{\times}256$ sized ID photo with BER value of 0 % when the test condition is 300dpi scanner and photo printer with 22 photos. In conclusion, proposed algorithm shows the robustness for noise and rotational errors occured during printing and scanning.

Evaluate the usefulness of Coincidence Summing Correction Factors for Cylinder and Extended Source Penelope Simulation (실린더 및 확장 소스 PENELOPE 시뮬레이션에 대한 동시합성보정 계수 유용성 평가)

  • Jang, Eun-Sung;Chang, Bo-Seok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.821-831
    • /
    • 2021
  • In order to calibrate energy and efficiency using the PENELOPE Code, a PENELOPE simulation was performed using a volume source. Here, we want to verify peak efficiency and usefulness by performing simultaneous measurement and correction. calculate the coincident sum correction for all volumes, first subdivide the volumes of the cylinder and the four Marinelli beakers into three heights again. Therefore, the simultaneous measurement correction coefficient in three areas and the simultaneous measurement correction coefficient for the entire volume source are calculated as output. At low energies, the j value for each source volume (50-300 ml) is small and increases significantly in the high energy range. Simulation results showed good agreement within 2.5% for all source volumes except for 50 ml and 300 ml, which were up to 4%. This means that the correction for the simultaneous measurement effect during measurement is effective. In addition. Based on this, it can be confirmed that there is an advantage to improve the detection efficiency when measuring various sources and environmental samples.

Measurement of Loss Factor and Young's Modulus of ABS and PP Specimens by Using a Speaker (스피커를 이용한 ABS와 PP의 손실계수 및 영률 측정)

  • Jeon, Byeong Su;Jung, Sung Soo;Lee, Jong Kyu
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.9
    • /
    • pp.724-730
    • /
    • 2014
  • It is essential to control noise and vibration in various industrial fields. In the automobile industry, various plastics have been developed and replaced metallic materials in order to reduce mass and vibration effectively. In this study, we measured and analyzed the Young's moduli and the loss factors of Acrylonitrile butadiene styrene(ABS) and Polypropylene(PP). In order to solve the fundamental error to determine the two quantities, a loudspeaker was used instead of conventional electromagnetic devices to generate bending motion to the specimens and a laser vibrometer was also used in detection of vibration signal of the specimen. The measured Young's moduli and loss factors of the ABS specimen were nearly constant as the temperature($-10{\sim}60^{\circ}C$) was increased. The loss factor of PP specimen showed peak value at $20^{\circ}C$ and it means that there is glass transition for the PP specimen. Young's modulus of PP specimen was linearly decreased as the temperature was increased.

Operational Method of Superconducting Fault Current Limiter with Reduction Function of Asymmetric Fault Current (비대칭 고장전류 저감 기능을 갖는 초전도 한류기 동작 방안)

  • Kim, Chang-Hwan;Seo, Hun-Chul;Kim, Kyu-Ho;Kim, Chul-Hwan;Rhee, Sang-Bong
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.56-62
    • /
    • 2014
  • When fault currents contain decaying DC offset, the peak value of the fault current in the first cycle of the fault period is higher than the fault current during the steady-state period. To reduce the asymmetric fault current, this paper proposes an operation scheme using the series connection of two hybrid type Superconducting Fault Current Limiters (SFCLs) : an auxiliary SFCL and a main SFCL. The proposed method calculates the fault angle by comparing the zero-crossing time with fault detection time. According to the fault angle calculated, an auxiliary SFCL operates to reduce an asymmetric fault current during half a cycle after fault occurrence. After this process, the fault current is limited by a main SFCL. To confirm the usefulness of the proposed method, case studies using Electro-Magnetic Transients Program (EMTP)/Alternative Transient Program (ATP) Draw are perfomed.

Image Enhancement Techniques for UT - NDE for Sizing and Detection of Cracks in Narrow Target (초음파 비파괴 평가를 위한 협소 타깃의 크랙 사이징 및 검출을 위한 영상 증진기술)

  • Lee, Young-Seock;Nam, Myoung-Woo;Hong, Sunk-Wan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.245-249
    • /
    • 2007
  • In this paper describes image enhancement technique using deconvolution processing for ultrasonic nondestructive testing. When flaws are detected fur B-scan or C-scan, blurring effect which is caused by the moving intervals of transducer degrades the quality of images. In addition, acquisited images suffer form speckle noise which is caused by the ultrasonic components reflected from the grain boundary of material (1,2). The deconvolution technique can restore sharp peak value or clean image from blurring signal or image. This processing is applied to C-scan image obtained from known specimen. Experimental results show that the deconvolution processing contributes to get improved the quality of C-scan images.

  • PDF

Analysis of Perchlorate in Water Using Ion Chromatograph with Preconcentration (이온크로마토그래프를 이용한 수중의 퍼클로레이트 농축 및 분석)

  • Kim, Hak-Chul
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.29-38
    • /
    • 2006
  • This study included the development of analytical method for determining perchlorate in water sample. The analytical condition was referred in EPA 314.0 method which use ion chromatography and the concentrator column was replaced by the guard column. Concentrating 10mL raw or treated water sample on to AGl6 guard column made it possible to get the LOD(Limit of Detection) of $0.73\;{\mu}g/L$. The total run time was 11 minutes and during run time next sample could be concentrated on AGl6 guard column. Compared to the Concentration method which needed manual operation, the Direct Injection method could screen the many water samples. The LOD of the Direct Injection method was higher and the sensitivity was lower than that of the Concentration method. The RSDs(Relative Standard Deviations) were lower than 2.5 % for peak height and 0.7 % for retention time in pre-concentration methods. This method Showed good reproducibility and reliability and it was thought the deviations of recovery value could be reduced by considering column capacity and making water sample homogeneous. Matrix Elimination could be done using the pre-concentration method if perchlorate were in complex matrix of sample.

Determination of Lead(II) at Nation-Coated Glassy Carbon Electrodes Modified by Tetren-Glycerol (Nafion-Tetren-Glycerol이 수식된 유리탄소전극에서 납(II) 이온의 정량)

  • 반옥기;박은희;정근호
    • Journal of Environmental Health Sciences
    • /
    • v.29 no.2
    • /
    • pp.62-68
    • /
    • 2003
  • Differential pulse voltammetry (DPV) using nafion-coated glassy carbon electrodes modified with Tetren(tetraethylene pentamine)-glycerol showed sensitivity for determining lead (II) at low concentration. The Lead (II) was accumulated on the electrode surface by the formation of the complex in an open circuit, and the resulting surface was characterized by medium exchange, electrochemical reduction, and differential pulse voltammetry. Various experimental parameters, such as the composition of modifier, preconcentration time, pH of electrolyte (0.1 M acetate buffer), and parameters of differential pulse voltammetry, were optimized. The initial potential was applied for 50 s, the electrode was scanned from -0.9 to -0.3 V, and the anodic peak current was measured at -0.604 V $\pm$ 0.015 V (vs. Ag/AgCl). The calibration plot was obtained in the range 1.0$\times$10$^{-8}$ M~l.0$\times$10$^{-6}$ M with pH 4.5 buffer solution. The detection limit (3$\sigma$) it as low as 5.0$\times$ 10$^{-9}$ M. This method is applied to the determination of lead(II) in a certified reference material and the result agrees satisfactorily with the certified value.

Fabrication and evaluation of label-free protein sensor for diagnosing acute myocardial infarction (급성 심근경색 검지를 위한 비표지식 단백질 센서 제작 및 검증에 관한 연구)

  • Cho, Younggeol;Kang, Ki-Won;Kim, Hyo-Kyum;Cho, Eikhyun;Kang, Shinill
    • Transactions of the Society of Information Storage Systems
    • /
    • v.9 no.1
    • /
    • pp.28-31
    • /
    • 2013
  • We proposed a method to fabricate label-free protein sensor with sub-wavelength nanograting structures to be used for diagnosing acute myocardial infarction. A nickel stamp for the injection molding of nanograting integrated protein sensor was fabricated by electroforming process with high fidelity. By using metallic stamp, we replicated label-free protein sensor via injection molding, which is an outstanding method for low-cost and mass production of polymer products. Finally, we performed a feasibility test, examining cardiac troponin T (cTnT) and anti-cTnT interactions. From the results, we demonstrated that the fabricated protein sensor can provide information for the early and accurate detection of cardiac diseases such as acute myocardial infarction.

Evaluation of neutron attenuation properties using helium-4 scintillation detector for dry cask inspection

  • Jihun Moon;Jisu Kim;Heejun Chung;Sung-Woo Kwak;Kyung Taek Lim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3506-3513
    • /
    • 2023
  • In this paper, we demonstrate the neutron attenuation of dry cask shielding materials using the S670e helium-4 detector manufactured by Arktis Radiation Ltd. In particular, two materials expected to be applied to the TN-32 dry cask manufactured by ORANO Korea and KORAD-21 by the Korea Radioactive Waste Agency (KORAD) were utilized. The measured neutron attenuation was compared with our Monte Carlo N-Particle Transport simulation results, and the difference is given as the root mean square (RMS). For the fast neutron case, a rapid decline in neutron counts was observed as a function of increasing material thickness, exhibiting an exponential relationship. The discrepancy between the experimentally acquired data and simulation results for the fast neutron was maintained within a 2.3% RMS. In contrast, the observed thermal neutron count demonstrated an initial rise, attained a maximum value, and exhibited an exponential decline as a function of increasing thickness. In particular, the discrepancy between the measured and simulated peak locations for thermal neutrons displayed an RMS deviation of approximately 17.3-22.4%. Finally, the results suggest that a minimum thickness of 5 cm for Li-6 is necessary to achieve a sufficiently significant cross-section, effectively capturing incoming thermal neutrons within the dry cask.