• Title/Summary/Keyword: peak value

Search Result 2,398, Processing Time 0.025 seconds

A Study on Radiation Quality of the Diagnostic X-ray Equipments (진단용(診斷用) X-선장치(線裝置)의 선질(線質) 특성(特性)에 관(關)한 연구(硏究))

  • Park, Myeong-Hwan;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.20 no.1
    • /
    • pp.55-59
    • /
    • 1997
  • The quality of continuous X-ray beam depends upon the half value layer which varies according to the geometric conditions, filtration thickness, and tube voltage. We compared the inverter type X-ray equipment with the conventional single phase 2 peak and the three phase 12 peak for the quality obtained by changes of the added filter thickness and the tube voltage. The quality of single phase 2 peak X-ray generator showed increase for the added filter and the tube volt-age. The half value layer is Increased the thicker the filter and the higher the kVp. The quality of the Inverter type and the three phase 12 peak in comparison with the single phase 2 peak X-ray generator is increased.

  • PDF

Nondestructive Evaluation for Remanent Life of 1Cr-0.5Mo Steel by Reversible Permeability

  • Ryu, Kwon-Sang;Lee, Yun-Hee;Park, Jong-Seo;Baek, Un-Bong
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.206-209
    • /
    • 2012
  • Peak interval for reversible permeability is presented for nondestructively evaluating the remanent life of 1Cr-0.5Mo steel. The method to measure the peak interval of reversible permeability is based on the value of reversible permeability is the same as the differential value of the hysteresis loop. The measurement principle is based on the first harmonics voltage induced in a sensing coil using a lock-in amplifier tuned to a frequency of the exciting voltage. Results obtained for the peak interval of reversible permeability and Rockwell hardness on the aged samples decrease as aging time and the Larson-Miller parameter increase. We could estimate the remanent life of 1Cr-0.5Mo steel by using the relationship between the peak interval of reversible permeability and the Larson-Miller parameter, nondestructively.

Robust Peak-to-peak Control of the Linear System (선형 시스템의 강인 피크 제어)

  • Ma, Sam-Sun;Hong, Seung-Soo;Kim, Jin-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07d
    • /
    • pp.1973-1975
    • /
    • 2001
  • In this paper, we consider the problem of robust peak-to-peak controller design of linear system. The goal is to design a controller which minimizes the maximum peak value of the measured output subjects to the peak bounded disturbance. The control is obtained by checking the feasibility of the derived matrix inequalities. Finally, we shows the usefulness of our result comparing to $H_{\infty}$ and $H_{2}$ control by an example.

  • PDF

Design of Efficient Trapezoidal Filter and Peak Value Detection Circuit for XRF Systems (XRF시스템용 효율적인 Trapezoidal 필터 및 최대값 검출 회로 설계)

  • Piao, Zheyan;Chung, Jin-Gyun
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.6
    • /
    • pp.138-144
    • /
    • 2013
  • In XRF systems, various techniques have been developed for the synthesis of pulse shapes using digital methods instead of traditional analog methods. Trapezoidal pulse shaping algorithms can be used for digital multi-channel pulse height analysis in X-ray spectrometer systems. In this paper, an efficient trapezoidal filter architecture is presented. In addition, we present a hardware-efficient peak value detection algorithm. By the proposed algorithm, peak value detection error is decreased by half compared with the conventional algorithm. The proposed Digital Pulse Processing(DPP) algorithm is designed using Verilog HDL and implemented using an FPGA on a test board. It is demonstrated that the implemented DPP board works successfully in practical XRF systems.

THE RELATIONSHIP BETWEEN BUFFER INDEX CURVE AND FERMENTATION QUALITY OF SILAGE

  • Kim, K.H;Uchida, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.4 no.1
    • /
    • pp.67-71
    • /
    • 1991
  • The purpose of this study was to investigate the possibility of using the buffer index curve as a criterion of silage quality evaluation. The buffer index (or buffer capacity, $\beta$) value is the amount of 0.1N NaOH consumed in titrating from the beginning to the end of the chosen pH step. This value equals the slope of the titration curve at the chosen pH range (${\beta}={\Delta}NaOH/{\Delta}pH$). There were two patterns of buffer index curve. Poorly preserved silages had a peak at pH 5.0, whereas with well preserved silages the peaks tended to rise to the pH 3.75 or 4.00. Well preserved, wilted silages with high pH also appeared to have peak values at pH 3.75 or 4.00. There was a high positive correlationship between the concentration of lactic acid and peak value of good quality silage (r = 0.994, p < 0.01). Also a high positive correlationship (r = 0.899, p < 0.001) was found between the sums of concentration of acetic and butyric acids and the peak values of poor quality silages. The results of these experiments verified the value of the buffer index method as a criterion of silage quality evaluation.

Assessment of Environmental Flow Impacts for the Gosam Reservoir According to Climate Change (기후변화에 따른 고삼저수지의 환경유량 영향평가)

  • Yoon, Tae Hyung;Kang, Ho Young;Kim, Jong Suk;Moon, Young Il
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.58 no.6
    • /
    • pp.93-100
    • /
    • 2016
  • This study conducted a quantitative assessment on the environmental flows associated with climate change in the Gosam Reservoir, Korea. The application of RCP 8.5 climate change scenario has found that the peak value of High Flow Pulses has increased by 36.0 % on average compared to historical data (2001 ~ 2010), which is likely to cause disadvantage on flood control and management but the increase in peak value is expected to make a positive impact on resolving the issue of green algal blooms, promoting vegetation in surrounding areas and encouraging spawning and providing habitats for native species by releasing a larger amount of landslides as well as organic matters than the past. However, the decreasing pattern of the peak value of High Flow Pulses is quite apparent with the trend of delay on the occurrence time of peak value, necessitating a long-term impact analysis. The peak value of Large Floods shows a clear sign of decrease against climate change scenario, which is expected to lead to changes in fish species caused by degraded quality of water and decreasing habitats. A quicker occurrence of Small Floods is also expected to make an impact on the growth cycle of aquatic plants, and the reduction in occurrence frequency of Extreme Low Flows is to contribute to increasing the population of and raising the survival rate of native fish, greatly improving the aquatic ecosystem. The results of this study are expected to be useful to establish the water environment and ecological system in adapting or responding to climate change.

A Study on the Charateristics of the Korean Adult Female Sound According to Sasang Constitution Using PSSC with a Sentence (사상체질음성분석기(四象體質音聲分析機)(PSSC)를 통한 한국인 성인여성(成人女性)의 체질별(體質別) 음향특성연구(音響特性硏究) - 단문(短文)을 중심으로 -)

  • Youn, Ji-Young;Yoon, Woo-Young;Cho, Sung-Eon;Wang, Hyang-Lan;Jeon, Jong-Weon;Kim, Dal-Rae;Yoo, Jun-Sang
    • Journal of Sasang Constitutional Medicine
    • /
    • v.18 no.3
    • /
    • pp.75-93
    • /
    • 2006
  • 1. Objectives and Methods Sasang Constitutional Medicine is the original Korean Medicine. The purpose of this study was to objectify the diagnosis of Sasang Constitution. 212 Women's sentences were analyzed into 228 factors like Pitch, APQ, Shimmer, Octave and Energy, etc. Women's sentences were classified into 3 categories: total group, under 54 years old group and over 55 years old group. 2. Results 1) In Total group Soyangin's Center feq.(3) was significantly high compared with Taeyangin and Taeumin groups. Taeumin's Pitch2 was significantly high compared with Soeumin and Taeyangin groups. Taeyangin's Pitch S.D. was significantly high compared with Soyangin group. Taeyangin's Octave6 was significantly high compared with Soeumin group. There were no significant differences among constitutional groups in APQ and Shimmer segment. On the point of Energy, Taeyangin's G Tot E(1), G# Tot E(1), G dev.(1), G# dev.(1), G Tot E(2), G# Tot E(2), G dev.(4) and G# dev.(4) were significantly high compared with other groups. Soyangin's A#S.D.(2) was significantly high compared with Taeyangin group. Taeyangin's A#S.D.(3) was significantly high compared with Taeumin group. Taeyangin's F S.D.(5), F# S.D.(5) and Max Average were significantly high compared with Soeumin group. Taeumin's Peak3 and Peak4 were significantly high compared with Taeyangin group. Taeumin's PeakValue1 was significantly high compared with Soeumin group. Taeyangin's PeakValue2 was significantly high compared with Soeumin group. Taeyangin's PeakValue3 and PeakValue5 were significantly high compared with Other groups. 2) In Under 54 years old group, there were no significant differences among constitutional groups in APQ, Shimmer and Octave segment. Taeumin's Center freq.(2) was significantly high compared with Taeyangin and Soyangin groups. Taeumin's Pitch(2) and Pitch(3) were significantly high compared with Taeyangin and Soeumin groups. Taeyangin's and Taeumin's Pitch S.D. were significantly high compared with Soyangin group. Taeyangin's and Soyangin's Octave2 were significantly high compared with Taeumin group. On the point of Energy, Taeyangin's and Soyangin's A# S.D.(2) were significantly high compared with Soeumin group. Taeyangin's and Soyangin's G# dev.(1), G# dev.(2) were significantly high compared with Taeumin group. Taeyangin's and Taeumin's F# S.D.(3) were significantly high compared with Soeumin group. Taeyangin's and Soyangin's Max Average were significantly high compared with Soeumin group. Taeumin's Peak3 was significantly high compared with Taeyangin and Soeumin groups. Taeyangin's and Taeumin's PeakValue2 were significantly high compared with Soeumin group. Taeyangin's and Soeumin's PeakValue3 were significantly high compared with Taeumin group. Taeyangin's and Soyangin's PeakValue5 were significantly high compared with Soeumin group. Taeyangin's and Soyangin's PeakValue9 were significantly high compared with Taeumin group 3) In Over 55 years old group, there were no significant differences among constitutional groups in Pitch, APQ, and Peak segment. Soeumin's F Shimmer(1) and F Shimmer(2) were significantly high compared with Taeyangin and Taeumin groups. Soeumin's G# Shimmer(1) and G# Shimmer(2) were significantly high compared with Soyangin group. Taeyangin's Octave5 and Octave6 were significantly high compared with Soeumin group. On the point of Energy, Soyangin's C S.D., F# S.D.(1), F# S.D.(2) and G dev.(2) were significantly high compared with other groups. Soyangin's F# S.D.(3) was significantly high compared with Taeumin and Soeumin groups. Taeyangin's and Taeumin's G# S.D.(2) and G# S.D.(3) were significantly high compared with Soyangin group 3. Conclusions From above result, there is the possibility of efficient standard guide for constitution diagnosis by analysis of voice

  • PDF

The Effects of Gel-type Insole on Patients with Knee Osteoarthritis during Gait (겔-타입 인솔이 무릎 골관절염 환자의 보행에 미치는 영향)

  • Eun, Seon-Deok;Yu, Yeon-Joo;Shin, Hak-Soo
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.3
    • /
    • pp.181-188
    • /
    • 2007
  • The purpose of this study was to investigate the biomechanical effects of wearing different type of insole shoes on gait characteristics in patients with knee osteoarthritis. Seven patients with knee osteoarthritis (Grade 3 & 4 by Kellgren & Lawrence) were participated in the study. They wore two different type of shoes (with Gel-type Insole: GIS, with Normal insole: NIS) during gait. Three dimensional cinematography and Ground Reaction Force(GRF) data were used to get the maximal value of horizontal distance between the center of pressure in GRF and knee joint center, GRF in mediolateral direction, peak value of GRF in frontal plane, vertical compressive force and adduction moment in knee joint. The results were as follows: The maximal value of horizontal distance between the center of pressure in GRF and knee joint center was smaller in GIS than NIS. The peak value of GRF in mediolateral direction was found in 30% of gait cycle, five subjects wearing GIS showed lower value of peak GRF in mediolateral direction than wearing NIS. The peak value of GRF in frontal plane and vertical compressive force in knee joint did not show any difference between GIS and NIS. The adduction moment in GIS decreased in the late stance of gait and the mean value of the adduction moment in GIS smaller than that in NIS. GIS may help to move quickly knee joint center to the center of pressure in GRF, therefore it may prevent increasing the adduction moment in knee joint.

Isokinetic Evaluation of Trunk Flexors and Trunk Extensors in Normal Adult Subjects and Patients with Post-operative Herniated Intervertebral Lumbar Disc (정상 성인남자와 요추간판탈출증 수술후 성인남자의 요추부 굴곡근 및 신전근의 등속성 근력평가)

  • Oh Seung-Kil
    • The Journal of Korean Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.81-98
    • /
    • 1998
  • Isokinetic evaluation of trunk flexors and trunk extensors was performed at $60^{\circ}/sec\;and\;120^{\circ}/sec$ of angular velocity by using cybex 6000TEF Unit on 31 healthy male white workers and 15 post-operative HILD patients with no significant difference in mean age and mean body weight between two groups, and compared each other. The purpose of this study is to obtain the isokinetic normative strength values and endurance latins for Dunk extensors and trunk flexors, and is to provide a guideline for rehabilitation program of post-operative HILD patients. The collected data were analyzed by ANOVA, Duncan's Nyktuoke Range Test, and Pearson correlation coefficiency in PC-SAS program, The results obtained were as follow ; 1. Post-operative subjects has lower isokinetic values than normal subjects in peak torque, peak torque $\%$ by body weight, total work, total work $\%$ by body weight, average power, average power $\%$ by body weight, TAAE of trunk flexors and trunk extensors, and there are significant differences with statistic value in trunk extensors at $60^{\circ}/sec$ and in trunk flexors and trunk extensors at $120^{\circ}/sec$ between two groups(p<0.05). 2. Pest-ooperative subjects has lower values for angle of peak torque than normal subjects in trunk extensors, and there are significant differences with statistic value at $60^{\circ}/sec$ and $120^{\circ}/sec$ between two groups. 3. Post-operative subjects has higher values for endurance ratios than normal subjects in trunk extensors and flexors, but there are no significant differences with statistic value between two groups. 4. Post-operative subjects has higher values than normal subjects in peak torque ratios, total work ratios, average power ratios of trunk flexors to trunk extensors, and there are significant differences with statistic value between two groups(p<0.01). 5. There is significant positive-correlation with statistic valve between peak torque and height and body weight in normal subjects(p<0.05), but Thjere is significant negative-correlation between peak torque of trunk extensor at $120^{\circ}/sec$ and age (p<0.05). 6. There is significant positive-correlation with statistic value between peak torque of trunk flexors and body weight in post-operative subjects (p<0.05), but There is significant negative-correlation between peak torque of trunk extensor add age (p<0.05). In conclusion, post-operative subjects have greater weakness in trunk musculature than normal subjects, especially there is more significant weakness in trunk extensors than in trunk flexors

  • PDF

Improved Diagnostic Accuracy in Characterization of Adnexal Masses by Detection of Choline Peak Using 1H MR Spectroscopy in Comparison to Internal Reference at 3 Tesla

  • Malek, Mahrooz;Pourashraf, Maryam;Gilani, Mitra Modares;Gity, Masoumeh
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.5085-5088
    • /
    • 2015
  • Background: The aim of this study was to assess the role of the presence of a choline peak in 3 Tesla 1H magnetic resonance spectroscopy (MRS) for differentiating benign from malignant adnexal masses. Materials and Methods: A total of 46 adnexal masses (23 malignant and 23 benign) underwent 1H MRS study prior to surgery to assess the presence of choline peak. Results: A choline peak was detected in 16 malignant masses (69.5%) and was absent in the other 7 (30.5%). A choline peak was only detected in 6 (26%) of the benign adnexal masses. The presence of an MRS choline peak had a sensitivity of 69.5%, a specificity of 74%, a positive predictive value (PPV) of 72.7%, and a negative predictive value (NPV) of 71% for diagnosing malignant adnexal masses. A significant difference between the frequency of mean choline peaks in benign and malignant adnexal masses was observed (P value < 0.01). Conclusions: A 1H MRS choline peak is seen in malignant adnexal masses more frequently than the benign masses, and may be helpful for diagnosing malignant adnexal masses.