• 제목/요약/키워드: peak support pressure

검색결과 25건 처리시간 0.027초

Research on reinforcement mechanism of soft coal pillar anchor cable

  • Li, Ang;Ji, Bingnan;Zhou, Haifeng;Wang, Feng;Liu, Yingjie;Mu, Pengfei;Yang, Jian;Xu, Ganggang;Zhao, Chunhu
    • Geomechanics and Engineering
    • /
    • 제29권6호
    • /
    • pp.697-706
    • /
    • 2022
  • In order to explore the stable anchoring conditions of coal side under the mining disturbance of soft section coal pillar in Wangcun Coal Mine of Chenghe Mining Area, the distribution model of the anchoring support pressure at the coal pillar side was established, using the strain-softening characteristics of the coal to study the distribution law of anchoring coal side support pressure. The analytical solution for the reinforcement anchorage stress in the coal pillar side was derived with the inelastic state mechanical model. The results show that the deformation angle of the roadway side and roof increases with the roof subsidence due to the mining influence at the adjacent working face, the plastic deformation zone extends to the depth of the coal side, and the increase of anchorage stress can effectively control the roof subsidence and further deterioration of plastic zone. The roadway height and the peak support pressure have a certain influence on the anchorage stress, the required anchorage stress of the coal side rises with the roadway height and the peak support pressure. The required anchorage stress of the coal pillar side decreases as the cohesion between the coal seam and the roof and floor and the anchor length increases. Then, applied the research result to Wangcun coal mine in Chenghe mining area, the design of anchor cable reinforcement support was proposed for the section of coal pillars side that has been anchored and deformed, which achieved great results and effectively controlled the convergence and deformation of the side, providing a safety guarantee for the roadway excavation and mining.

The Influence of Auditory-Feedback Device Using Wearable Air-Pressure Insole on Spatiotemporal Gait Symmetry in Chronic Hemplegia

  • Heo, Ji-Hun;Song, Changho;Jung, Sangwoo
    • Physical Therapy Rehabilitation Science
    • /
    • 제10권3호
    • /
    • pp.311-319
    • /
    • 2021
  • Objective: To investigate the effect of emphasized initial contact by using a wearable air-pressure insole to provide auditory-feedback with variations of maximum peak pressure (MPP) of the affected side on spatiotemporal gait parameters and gait symmetry of stroke patients Design: A cross-sectional study Methods: Eighteen stroke patients participated in this study. All subjects walked five trials using an air-pressure insole that provides auditory feedback with different thresholds set on the insole. First, subjects walked without any auditory feedback. Then, the MPP threshold on the affected side was set from 70% and increase threshold by 10% after each trial until 100%. They walked three times or more on the gait analyzer for each trial, and the average values were measured. Before starting the experiment, subjects measured body weight, initial gait abilities and affected side MPP without auditory feedback. Results: Temporal and spatial variables were significantly increased in trials with auditory feedback from air-pressure insole except for non-paralyzed single support time and spatial gait symmetry compared to trials without auditory feedback(p<0.05). Among the four different thresholds, the walking speed, unaffected side single support time, affected and unaffected side stride, and affected side step length were greatest at 80% threshold of maximum peak, while affected single support time, temporal gait symmetry, and unaffected step length were greatest at the maximum peak of 100% threshold. Conclusions: These results indicate that auditory feedback gait using air-pressure insoles can be an effective way to improve walking speed, single support time, step length, stride, and temporal gait symmetry in stroke patients.

편평족 노인의 계단 하강 보행 시 아치 지지형 인솔 종류에 따른 족저압력 및 균형성 평가 (Comparison of plantar pressure and COP parameters in three types of arch support insole during stair descent in elderly with flatfoot)

  • 한기훈;배강호;정하곤;하민성;최도열;이중숙;양정옥
    • 한국응용과학기술학회지
    • /
    • 제35권3호
    • /
    • pp.948-955
    • /
    • 2018
  • 본 연구의 목적은 평발을 가진 여성 노인의 계단 하강 보행 시 일반인솔 및 아치 지지형 인솔을 적용에 따른 족저압력 및 압력중심점 변인들의 차이를 조사하는데 목적이 있다. 족저압력 분석장비(Pedar-X, Novel, Germany)를 사용하여 14명의 평발 노인을 대상으로 3종류(일반인솔, A형 인솔, B형 인솔)의 인솔착용 후 최대족저압력, 평균족저압력, 접촉면적, 압력중심점의 이동거리, 변위 및 최대범위의 평균값을 산출하였으며, 일원변량분석(one-way ANOVA)를 이용하여 인솔 종류간 평균을 비교하였다. 족저 압력 변인 중 최대족저압력은 중족부의 M3, 평균족저압력은 M2, M3, M4 영역에서, 접촉면적은 M2, M3, 그리고 M6 영역에서 통계적으로 유의한 차이를 보였으며, 압력중심점 변인 중 전후축과 좌우축에서 압력중심점의 이동거리에서 통계적으로 유의한 차이를 보였다. 족저압력 평가결과 아치 지지 기능을 가진 인솔을 삽입한 A와 B형 인솔에서 족궁지지 영역인 M3의 최대압력은 B형 인솔과 A형 인솔이 일반인솔과 비교했을 때 높게 나타났다. 좌우축, 전후축 압력중심점의 이동거리는 A형과 B형 인솔 모두 일반 인솔에 비해 짧게 나타났다.

Biomechanical Effectiveness of the Low-Dye Taping on Peak Plantar Pressure During Treadmill Walking Exercise in Subjects With Flexible Flatfoot

  • Lim, One-Bin;Kim, Jeong-Ah;Kwon, Oh-Yun;Yi, Chung-Hwi
    • 한국전문물리치료학회지
    • /
    • 제22권2호
    • /
    • pp.41-51
    • /
    • 2015
  • The purposes of this study were 1) to determine the effects of low-dye taping on peak plantar pressure following treadmill walking exercise, 2) to determine whether the biomechanical effectiveness of low-dye taping in peak plantar pressure was still maintained following removal of the tape during treadmill walking, and 3) to determine the trend towards a medial-to-lateral shift in peak plantar pressure in the midfoot region before and after application of low-dye taping. Twenty subjects with flexible flatfoot were recruited using a navicular drop test. The peak plantar pressure data were recorded during five treadmill walking sessions: (1) un-taped, (2) baseline-taped, (3) after a 10-minute treadmill walking exercise, (4) after a 20-minute treadmill walking exercise, and (5) after removal of the taping. The foot was divided into six parts during the data analysis. One-way repeated measures analysis of variance was performed to investigate peak plantar pressure variations in the six foot parts in the five sessions. This study resulted in significantly increased medial forefoot peak plantar pressure compared to the un-taped condition (p=.017, post 10-minute treadmill walking exercise) and (p=.021, post 20-minute treadmill walking exercise). The peak plantar pressure in the lateral forefoot showed that there was a significant decrease after sessions of baseline-taped (p=.006) and 10-minute of treadmill walking exercise (p=.46) compared to the un-taped condition. The tape removal values were similar to the un-taped values in the five sessions. Thus, the findings of the current study may be helpful when researchers and clinicians estimate single taping effects or consider how frequently taping should be replaced for therapeutic purposes. Further studies are required to investigate the evidence in support of biomechanical effectiveness of low-dye taping in the midfoot region.

압력보조 환기법으로 기계호흡 이탈시 최소압력보조(Minimal Pressure Support) 수준의 결정 (Determination of Minimal Pressure Support Level During Weaning from Pressure Support Ventilation)

  • 정복현;고윤석;임채만;이상도;김우성;김동순;김원동
    • Tuberculosis and Respiratory Diseases
    • /
    • 제45권2호
    • /
    • pp.380-387
    • /
    • 1998
  • 연구배경: 압력보조환기법은 기계호흡으로부터 이탈시 최근에 많이 이용되는 인공환기법으로 적절한 압력보조 수준이 이탈 과정에 중요하며 특히 최소압력보조 (minimal pressure support) 수준에서 환자의 환기 상태가 적절하면 치료자는 인공 호흡기로 부터 여탈 및 기관내 관을 발관할 수 있다. 그러나 부적절한 최소압력 보조 수준의 적용은 환기 이탈 기간의 장기화나 이탈 실패를 초래할 수 있다. 본 연구는 이탈기 환자들이 최소압력보조 치의 범위를 알아보고 또한 최대 흡기유량과 총환기계 저항의 곱으로 구한 최소압력보조치의 계산값과 환자의 기관내 관 끝에서 실측한 값 사이의 차이를 비교함으로써 유도식으로 계산된 최소압력 보조 값의 임상적 유용성을 예측하고자 하였다. 방 법: 기저 질환이 호전되어 기계호흡으로부터 이탈이 가능한 환자 16명을 대상으로 폐 감시기 (CP-100 pulmonary monitor, Bicore, USA)를 이용하여 부가된 호흡일을 구한 후 최소압력보조의 수준을 직접 측정하였고, 이들 중 9예에서는 또한 유도식 (peak inspiratory flow rate$\times$total ventilatory system resistance=minimal pressure support)을 이용하여 최소합력보조의 수준을 구하였다. 결 과: 대상환자 16명중 14명에서 측정한 최소압력보조의 실측치는 4~12.5 cm$H_2O$로써 환자에 따라 차이가 심하였다. 대상 환자 중 2명에서 각각 15, 21 cm$H_2O$로써 높게 측정되었으나 기관내 관을 발관 후 내강이 기도 분비물로 심한 폐쇄가 발견되었다. 실측치를 측정한 16명중 9명에서 유도식을 이용하여 최소압력 보조의 계산치를 구하였으며 실측치와 계산치의 비는 평균 0.81로 실측치 보다 높게 나타나는 경향을 보였으나 실측치와 계산치의 상관 계수는 0.88(p=0.002)로 통계학적으로 유의한 상관관계를 보였다. 결 론: 압력보조환기법에 의한 이탈 시도시 최소압력보조 수준의 결정은 유도식을 이용하여 계산된 값을 적용하는 것이 치료자가 임의적으로 일정한 값을 적용하는 것보다 더 나을 것으로 사료된다.

  • PDF

정상 보행의 속도와 경사에 따른 족저압 분포의 특성 (The Characteristics of Foot Pressure Distribution According to Walking Speeds of Normal Gait and Ground Inclinations)

  • 홍완성;김기원
    • 대한물리치료과학회지
    • /
    • 제11권4호
    • /
    • pp.29-37
    • /
    • 2004
  • Measurements of plantar pressure provide an indication of foot and ankle function during gait and other functional activities because the foot and ankle provide necessary support and flexibility for weight bearing and weight shifting while people are performing these activities. Plantar pressure is being increasingly used in both research and clinical practice to measure the effects of various footwear and physical therapy intervention. The influence of walking speed and ground inclination on plantar pressure parameters However has not been evaluated in detail. So, in this study to determine the effect of changes in walking speed and ground inclination on plantar pressure treadmills with different walking speeds and inclination were used. Plantar pressure parameters were measured with the Parotec system using the walking and running in 20 healthy participants(10 male, 10 female) aged $20{\sim}28$(mean 22.22, S.D.2.26 years) when slow walking and running. The result of this study with increased die walking speed, the peak pressure of 1st, 5th metatarsal head and total contact time and impulse total at the forefoot was affected by walking speed; however, die peak pressure, contact time and impulse total at the forefoot was not affected by ground inclination.

  • PDF

생체조직내 레이저 광 밀도 향상을 위한 압력 인가형 저출력 레이저 프로브 (A Pressure Applied Low-Level Laser Probe to Enhance Laser Photon Density in Soft Tissue)

  • 여창민;박정환;손태윤;이용흠;정병조
    • 대한의용생체공학회:의공학회지
    • /
    • 제30권1호
    • /
    • pp.18-22
    • /
    • 2009
  • Laser has been widely used in various fields of medicine. Recently, noninvasive low-level laser therapeutic medical devices have been introduced in market. However, low-level laser cannot deliver enough photon density to expect positive therapeutic results in deep tissue layer due to the light scattering property in tissue. In order to overcome the limitation, this study was aimed to develop a negative pressure applied low-level laser probe to optimize laser transmission pattern and therefore, to improve photon density in soft tissue. In order to evaluate the possibility of clinical application of the developed laser probe, ex-vivo experiments were performed with porcine skin samples and laser transmissions were quantitatively measured as a function of tissue compression. The laser probe has an air suction hole to apply negative pressure to skin, a transparent plastic body to observe variations of tissue, and a small metallic optical fiber guide to support the optical fiber when negative pressure was applied. By applying negative pressure to the laser probe, the porcine skin under the metallic optical fiber guide is compressed down and, at the same time, low-level laser is emitted into the skin. Finally, the diffusion images of laser in the sample were acquired by a CCD camera and analyzed. Compared to the peak intensity without the compression, the peak intensity of laser increased about $2{\sim}2.5$ times and FWHM decreased about $1.67{\sim}2.85$ times. In addition, the laser peak intensity was positively and linearly increased as a function of compression. In conclusion, we verified that the developed low-level laser probe can control the photon density in tissue by applying compression, and therefore, its potential for clinical applications.

Preliminary Study on the Comparison of Calcaneus Taping and Arch Taping Methods for Flexible Flatfoot Subjects

  • Jinteak Kim;Byeongsoo Kim;Jongduk Choi
    • 한국전문물리치료학회지
    • /
    • 제30권4호
    • /
    • pp.281-287
    • /
    • 2023
  • Background: The flexible flatfoot is characterized by a flattening of the foot arch due to excessive bodyweight. The use of shoe insoles or taping methods has been identified as effective in realigning the navicular or calcaneus bones and addressing supination in pronated feet. Objects: This study aimed to analyze the difference between the arch taping attachment method, introduced in a previous study, and a novel taping method designed to provide support to the inner aspect of the heel bone in cases of flexible flatfoot. Methods: A navicular drop test was performed to discriminate flexible flatfoot. To analyze the differences in pressure distribution during walking for each taping method, the subjects underwent testing in the barefoot state with no attachments. The procedure included a sequence of arch taping and heel taping. Subsequent analysis of pressure distribution during walking utilized the GaitRite® system (GAITRite Gold, CIR Systems Inc.). Results: Arch taping and calcaneus taping significantly reduced the integrated pressure over time and peak pressure on the medial side of the midfoot for both feet compared to the barefoot state. Conclusion: The findings of this study suggest that supporting the inside of the heel through calcaneus taping, without direct stimulation to the longitudinal arch and navicular bone, is an effective intervention for flexible flatfoot.

Research on the deformation characteristics and support methods of the cross-mining roadway floor influence by right-angle trapezoidal stope

  • Zhaoyi Zhang;Wei Zhang
    • Geomechanics and Engineering
    • /
    • 제37권3호
    • /
    • pp.293-306
    • /
    • 2024
  • Influenced by the alternating effects of dynamic and static pressure during the mining process of close range coal seams, the surrounding rock support of cross mining roadway is difficult and the deformation mechanism is complex, which has become an important problem affecting the safe and efficient production of coal mines. The paper takes the inclined longwall mining of the 10304 working face of Zhongheng coal mine as the engineering background, analyzes the key strata fracture mechanism of the large inclined right-angle trapezoidal mining field, explores the stress distribution characteristics and transmission law of the surrounding rock of the roadway affected by the mining of the inclined coal seam, and proposes a segmented and hierarchical support method for the cross mining roadway affected by the mining of the close range coal seam group. The research results indicate that based on the derived expressions for shear and tensile fracture of key strata, the ultimate pushing distance and ultimate suspended area of a right angle trapezoidal mining area can be calculated and obtained. Within the cross mining section, along the horizontal direction of the coal wall of the working face, the peak shear stress is located near the middle of the boundary. The cracks on the floor of the cross mining roadway gradually develop in an elliptical funnel shape from the shallow to the deep. The dual coupling support system composed of active anchor rod support and passive U-shaped steel shed support proposed in this article achieves effective control of the stability of cross mining roadways, which achieves effective control of floor by coupling active support and preventive passive support to improve the strength of the surrounding rock itself. The research results are of great significance for guiding the layout, support control, and safe mining of cross mining roadways, and to some extent, can further enrich and improve the relevant theories of roof movement and control.

A Comparative Study on the Effects of Three Types of Pillows on Head-neck Pressure Distribution and Cervical Spine Alignment

  • Kyeong-Ah Moon;Ji-Hyun Kim;Ye Jin Kim;Joo-Hee Park;Hye-Seon Jeon
    • 한국전문물리치료학회지
    • /
    • 제31권1호
    • /
    • pp.8-17
    • /
    • 2024
  • Background: Sleep accounts for approximately one-third of a person's lifetime. It is a relaxing activity that relieves mental and physical fatigue. Pillows of different sizes, shapes, and materials have been designed to improve sleep quality by achieving an optimal sleep posture. Objects: This study aimed to determine which pillow provides the most comfortable and supports the head and neck during sleep, which may enhance sleep quality. Methods: Twenty-eight healthy adults (19 males and 9 females) with an average age of 29 years participated in this cross-sectional study. This experiment was conducted while the participants laid down for 5 minutes in four different pillow conditions: (1) no pillow (NP), (2) neck support foam pillow (NSFP), (3) standard microfiber filled pillow (SFP), and (4) hybrid foam pillow (HFP). The head-neck peak pressure, cranio-vertebral angle in supine (CVAs), cranio-horizontal angle in supine (CHAs), chin-sternum distance (CSD), and muscle tone of sternocleidomastoid were analyzed using one-way repeated measures analysis of variance (ANOVA). The significance level was set at p < 0.05. Results: The head-neck peak pressure was the highest in the NSFP condition, followed by the NP, SFP, and HFP conditions. The CVAs, CHAs, and CSD of the SFP were lower than those of the other pillows. Muscle tone was the highest in the NP condition, followed by the of NSFP, HFP, and SFP conditions. The participants subjective comfort level in both the supine and side-lying postures was highest in the HFP condition, followed by the SFP and NSFP conditions. Conclusion: This study can be used to establish the importance of pillow selection for high-quality sleep. The results of this study, suggest that a hybrid pillow with a good supportive core and appropriate fluffiness can maintain comfort and correct cervical spine alignment during sleep.