• Title/Summary/Keyword: peak signal to noise ratio

Search Result 493, Processing Time 0.027 seconds

ICI and Compensation Algorithm against Frequency Offset and Phase Noise in SC-FDMA System with Comb Type Pilot (Comb Type 파일럿을 갖는 SC-FDMA에서 주파수 옵셋과 위상 잡음에 의한 ICI와 보상 알고리즘)

  • Ryu, Sang-Burm;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.4
    • /
    • pp.399-407
    • /
    • 2010
  • SC-FDMA system uses DFT-spreading method for reducing the PAPR of OFDM signal, which improves the power efficiency. Block type pilot is used in SC-FDMA system. However, there are ICI due to the inevitable phase noise and frequency offset that can be generated from the Doppler frequency and inaccuracy between the transceiver oscillators. This ICI definitely degrades the BER performance. To overcome this problem and estimate the channel efficiently, we like to propose ICI compensation algorithm for the SC-FDMA system with comb type pilot. SLM method is additionally included for the PAPR reduction when pilot is assigned in comb type. Finally, it is confirmed that the ICI due to the phase noise and frequency offset is efficiently compensated by the suggested algorithm.

Signal to Noise Ratio of MR Spectrum by variation echo time : comparison of 1.5T and 3.0T (Echo time에 따른 MR spectrum의 SNR: 1.5T와 3.0T비교)

  • Kim, Sung-Gil;Lee, Kyu-Su;Rim, Che-Pyeong
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.401-407
    • /
    • 2011
  • The purpose of this study is to know the differences of MR spectra, obtained from normal volunteers by variable TE value, through the quantitative analysis of brain metabolites by peak integral and SNR between 1.5T and 3.0T, together with PRESS and STEAM pulse sequence. Single-voxel MR proton spectra of the human brain obtained from normal volunteers at both 3.0T MR system (Magnetom Trio, SIEMENS, Germany) and 1.5T MR system (Signa Twinspeed, GE, USA) using the STEAM and PRESS pulse sequence. 10 healthy volunteers (3.0T:3 males, 2 females; 1.5T : 3 males, 2 females) with the range from 22 to 30 years old (mean 26 years) participated in our study. They had no personal or familial history of neurological diseases and had a normal neurological examination. Data acquisition parameters were closely matched between the two field strengths. Spectra were recorded in the white matter of the occipital lobe. Spectra were compared in terms of resolution and signal-to-noise ratio(SNR), and echo time(TE) were estimated at both field strengths. Imaging parameters was used for acquisition of the proton spectrum were as follow : TR 2000msec, TE 30ms, 40ms, 50ms, 60ms, 90ms, 144ms, 288ms, NA=96, VOI=$20{\times}20{\times}20mm3$. As the echo times were increased, the spectra obtained from 3.0T and 1.5T show decreased peak integral and SNR at both pulse sequence. PRESS pulse sequence shows higher SNR and signal intensity than those of STEAM. Especially, Spectra in normal volunteers at 3.0T demonstrated significantly improved overall SNR and spectral resolution compared to 1.5T(Fig1). The spectra acquired at short echo time, 3T MR system shows a twice improvement in SNR compared to 1.5T MR system(Table. 1). But, there was no significant difference between 3.0Tand 1.5T at long TE It is concluded that PRESS and short TE is useful for quantification of the brain metabolites at 3.0T MRS, our standardized protocol for quantification of the brain metabolites at 3.0T MRS is useful to evaluate the brain diseases by monitoring the systematic changes of biochemical metabolites concentration in vivo.

Evaluation of Image Quality according to Insert Position and Thickness Change by Fabricating Modified ACR Phantom in Mammography (유방엑스선검사에서의 변형된 ACR 팬텀 제작을 통한 모조병소의 위치와 두께 변화에 따른 영상의 품질 평가)

  • Uhm, Hyon-Ja;Park, Chanrok
    • Journal of radiological science and technology
    • /
    • v.45 no.2
    • /
    • pp.103-109
    • /
    • 2022
  • To maintain improved image quality in mammography, the quality control process is performed using the ACR (American college of radiology) phantom. In addition, many studied were performed by fabricating the customized breast phantom to provide more information in mammography. Thus, the purpose of this study was to evaluate the image quality by designing the modified ACR phantoms. The five modified acrlylic ACR phantoms were designed by considering insert position and phantom thickness. The phantoms were consisted of 4.5, 3.0, and 1.5 cm in terms of phantom thickness, and 3.0, 2.0, and 0.5 cm in terms of insert position, respectively. The acquired images were evaluated by PSNR (peak signal to noise ratio), RMSE (root mean square error), CC (correlation coefficient), CNR (contrast to noise ratio), and COV (coefficient of variation). Based on the similarity analysis, the result is suitable between conventional and new designed phantoms. In addition, the CNR and COV results in terms of insert position showed that image quality for 0.5 cm was 2.3 and 27.4% improved compared with 2 and 3 cm, respectively. According to phantom thickness results, the CNR result for 1.5 cm and COV result for 4.5 cm were 50.1 and 62.7% improved compared with that those conditions. In conclusion, we confirmed that the image quality depends on the breast size and thickness through modified ACR phantom study.

A study on non-local image denoising method based on noise estimation (노이즈 수준 추정에 기반한 비지역적 영상 디노이징 방법 연구)

  • Lim, Jae Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.518-523
    • /
    • 2017
  • This paper proposes a novel denoising method based on non-local(NL) means. The NL-means algorithm is effective for removing an additive Gaussian noise, but the denoising parameter should be controlled depending on the noise level for proper noise elimination. Therefore, the proposed method optimizes the denoising parameter according to the noise levels. The proposed method consists of two processes: off-line and on-line. In the off-line process, the relations between the noise level and the denoising parameter of the NL-means filter are analyzed. For a given noise level, the various denoising parameters are applied to the NL-means algorithm, and then the qualities of resulting images are quantified using a structural similarity index(SSIM). The parameter with the highest SSIM is chosen as the optimal denoising parameter for the given noise level. In the on-line process, we estimate the noise level for a given noisy image and select the optimal denoising parameter according to the estimated noise level. Finally, NL-means filtering is performed using the selected denoising parameter. As shown in the experimental results, the proposed method accurately estimated the noise level and effectively eliminated noise for various noise levels. The accuracy of noise estimation is 90.0% and the highest Peak Signal-to-noise ratio(PSNR), SSIM value.

Optimized Sigma-Delta Modulation Methodology for an Effective FM Waveform Generation in the Ultrasound System (효율적인 주파수 변조된 초음파 파형 발생을 위한 최적화된 시그마 델타 변조 기법)

  • Kim, Hak-Hyun;Han, Ho-San;Song, Tai-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.3
    • /
    • pp.429-440
    • /
    • 2007
  • A coded excitation has been studied to improve the performance for ultrasound imaging in term of SNR, imaging frame rate, contrast to tissue ratio, and so forth. However, it requires a complicated arbitrary waveform transmitter for each active channel that is typically composed of a multi-bit Digital-to-Analog Converter (DAC) and a linear power amplifier (LPA). Not only does the LPA increase the cost and size of a transmitter block, but it consumes much power, increasing the system complexity further and causing a heating-up problem. This paper proposes an optimized 1.5bit fourth order sigma-delta modulation technique applicable to design an efficient arbitrary waveform generator with greatly reduced power dissipation and hardware. The proposed SDM can provide a required SQNR with a low over-sampling ratio of 4. To this end, the loop coefficients are optimized to minimize the quantization noise power in signal band while maintaining system stability. In addition, the decision level for the 1.5 bit quantizer is optimized for a given input waveform, which results in the SQNR improvement of more than 5dB. Computer simulation results show that the SQNR of a FM(frequency modulated) signal generated by using the proposed method is about 26dB, and the peak side-lobe level (PSL) of its compressed waveform on receive is -48dB.

The Design Method of GNSS Signal Using the Analysis Result of Receiver Performance (수신 성능 분석을 이용한 위성항법 신호 설계 방안)

  • Jin, Mi-Hyun;Choi, Heon-Ho;Kim, Kap-Jin;Park, Chan-Sik;Ahn, Jae-Min;Lee, Sang-Jeong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37 no.6C
    • /
    • pp.502-511
    • /
    • 2012
  • As the importance of GNSS system increases, the necessity of independent system is increased also. When the independent GNSS system is required, GNSS signal design is necessary with requirement definition. This paper suggests the design method of GNSS signal using the analysis result of receiver performance. First, the candidates are defined based on the design elements. Then the receiver performance of the candidates is analyzed based on the performance evaluation parameters. The weights of performance evaluation parameter are defined in order to consider the receiver performance in a various aspects. Finally, the calculation of normalized performance evaluation parameters and weights are derived to obtain the compared value for signal selection. Spreading code, modulation method and carrier frequency are considered as design parameters. Also, correlation width, DLL PLL thermal noise jitter, frequency bandwidth and side lobe peak ratio are considered as performance evaluation parameters. And positioning performance, robustness to noise, bandwidth efficiency are considered as the performance aspects. This paper analyzes the performance of each candidate using software based simulator and suggest the method to compare objectively the performance of each candidates.

Design and Implementation of Microstrip Quadrature Coupler and High Power Transmitting/Receiving Switch Using Dynamic Loading Technique for 1-Tesal MRI System (동적 부하 기술을 이용한 1-Tesla 자기공명 영상 시스템용 마이크로 스트립 quadrature coupler 및 고출력 송수신 스위치의 설계 및 제작)

  • 류웅환;이미영;이흥규;이황수;김정호
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.36D no.3
    • /
    • pp.1-11
    • /
    • 1999
  • It is now common practice to utilize the quadrature RF coils to improve the signal-to-noise ratio (SNR) in the Magnetic Resonance Imaging (MRI) System. In addition, to make such an available SNR improvement, it is mandatory to use a well-designed quadrature coupler, which facilitates a perfect 3-dB coupling and quadrature-phase shift. However, the four ports matching condition has to be well considered during the RF excitation and the signal detection period. This work investigates the effects of such a mismatching condition (especially, due to patient) from the analysis, simulation, and real implementation and firstly proposes dynamic loading technique for a quadrature coupler and transmitting/receiving switch module to minimize a patient mismatching and enhance a system reliability. Also, we designed and implemented the quadrature coupler and transmitting/receiving switch module using microstrip. As a result, the SNR of our MRI system using the microstrip quadrature coupler and transmitting/receiving switch module with dynamic load increases 3 dB compared with the old one using USA quadrature switch. Also, the power capability of quadrature coupler and transmitting/receiving switch module is 5-kw peak power. Considering power loss and reduction of size, we used a RT/duroid 6010 substrate with high permittivity and for simulation we use Compact Software.

  • PDF

A Fast Fractal Image Decoding Using the Minimizing Method of Domain Region by the Limitation of Searching Regions (탐색영역 제한에 의한 정의역 최소화 기법을 이용한 고속 프랙탈 영상복원)

  • 정태일;강경원;문광석;권기룡;김문수
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.2
    • /
    • pp.13-19
    • /
    • 2001
  • The conventional fractal decoding was required a vast amount computational complexity, since every range blocks was implemented to IFS(iterated function system). In order to improve this, it has been suggested that each range block was classified to iterated and non-iterated regions. Non-iterated regions is called data dependency region, and if data dependency region extended, IFS regions are contractive. In this paper, a searched region of the domain is limited to the range regions that is similar with the domain blocks, and the domain region is more overlapped. As a result, data dependency region has maximum region, that is IFS regions can be minimum region. The minimizing method of domain region is defined to minimum domain(MD) which is minimum IFS region. Using the minimizing method of domain region, there is not influence PSNR(peak signal-to-noise ratio). And it can be performed a fast decoding by reducing the computational complexity for IFS in fractal image decoding.

  • PDF

A Method of Coupling Expected Patch Log Likelihood and Guided Filtering for Image De-noising

  • Wang, Shunfeng;Xie, Jiacen;Zheng, Yuhui;Wang, Jin;Jiang, Tao
    • Journal of Information Processing Systems
    • /
    • v.14 no.2
    • /
    • pp.552-562
    • /
    • 2018
  • With the advent of the information society, image restoration technology has aroused considerable interest. Guided image filtering is more effective in suppressing noise in homogeneous regions, but its edge-preserving property is poor. As such, the critical part of guided filtering lies in the selection of the guided image. The result of the Expected Patch Log Likelihood (EPLL) method maintains a good structure, but it is easy to produce the ladder effect in homogeneous areas. According to the complementarity of EPLL with guided filtering, we propose a method of coupling EPLL and guided filtering for image de-noising. The EPLL model is adopted to construct the guided image for the guided filtering, which can provide better structural information for the guided filtering. Meanwhile, with the secondary smoothing of guided image filtering in image homogenization areas, we can improve the noise suppression effect in those areas while reducing the ladder effect brought about by the EPLL. The experimental results show that it not only retains the excellent performance of EPLL, but also produces better visual effects and a higher peak signal-to-noise ratio by adopting the proposed method.

Copyright Protection for the Video image with Coded Watermarking (암호화 워터마킹을 사용한 비디오 영상의 저작권 보호)

  • Park, Young;Kim, Hang-Rae;Rhu, Ho-Joon;Kim, Jae-Won
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2003.11a
    • /
    • pp.120-123
    • /
    • 2003
  • In this paper, a digital watermarking scheme whichis effective in protecting a copyright of video image under an image transformation and impulse noise is proposed. The proposing scheme is to use a coded watermark that insert the personal ID of copyrighter. The recovery ability is improved by the coded watermark. Also the coded watermark is abel to trace the illegal distributors. Binary image is used as watermark image, the value of PSNR and recovered rates of watermark are obtained in order to confirm the required invisibility and robustness in watermark system. The experimental results show that image quality is less degraded as the PSNR of 98.21 ㏈. It is also observed that excellent watermark recovery is achieved under the image transformation and impulse noise.

  • PDF