• 제목/요약/키워드: peak set

검색결과 590건 처리시간 0.026초

심자도의 P-Q 구간과 T-P 구간에서 설정한 베이스 라인의 효과에 대한 연구 (Effects of Baseline Selection on Magnetocardiography: P-Q and T-P Intervals)

  • 임현균;권혁찬;김태은;이용호;김진목;김인선;김기웅;박용기
    • Progress in Superconductivity
    • /
    • 제9권1호
    • /
    • pp.29-34
    • /
    • 2007
  • The baseline selection is the first and important step to analyze magnetocardiography (MCG) parameters. There are no difficulties to select the baseline between P- and Q-wave peak (P-Q interval) of MCG wave recorded from healthy subjects because the P-Q intervals of the healthy subjects do not much vary. However, patients with ischemic heart disease often show an unstable P-Q interval which does not seem to be appropriate for the baseline. In this case, T-P interval is alternatively recommended for the baseline. However, there has been no study on the difference made by the baseline selection. In this study, we studied the effect of the different baseline selection. MCG data were analyzed from twenty healthy subjects and twenty one patients whose baselines were alternatively selected in the T-P interval for their inappropriate P-Q interval. Paired T-test was used to compare two set of data. Fifteen parameters derived from the R-wave peak, the T-wave peak, and the period, $T_{max/3}{\sim}T_{max}$ were compared for the different baseline selection. As a result, most parameters did not show significant differences (p>0.05) except few parameters. Therefore, there will be no significant differences if anyone of two intervals were selected for the MCG baseline. However, for the consistent analysis, P-Q interval is strongly recommended for the baseline correction.

  • PDF

IGZO, ZnO, AZO OMO 구조의 Ag두께 변화에 따른 투과율과 에너지 밴드 갭의 변화 (Change in the Energy Band Gap and Transmittance IGZO, ZnO, AZO OMO Structure According to Ag Thickness)

  • 이승민;김홍배;이상렬
    • 한국전기전자재료학회논문지
    • /
    • 제28권3호
    • /
    • pp.185-190
    • /
    • 2015
  • In this study, we fabricated the indium gallium zinc oxide (IGZO), zinc oxide (ZnO), aluminum zinc oxide (AZO). oxide and silver are deposited by magnetron sputtering and thermal evaporator, respectively transparency and energy bandgap were changed by the thickness of silver layer. To fabricate metal oxide metal (OMO) structure, IGZO sputtered on a corning 1,737 glass substrate was used as bottom oxide material and then silver was evaporated on the IGZO layer, finally IGZO was sputtered on the silver layer we get the final OMO structure. The radio-frequency power of the target was fixed at 30 W. The chamber pressure was set to $6.0{\times}10^{-3}$ Torr, and the gas ratio of Ar was fixed at 25 sccm. The silver thickness are varied from 3 to 15 nm. The OMO thin films was analyzed using XRD. XRD shows broad peak which clearly indicates amorphous phase. ZnO, AZO, OMO show the peak [002] direction at $34^{\circ}$. This indicate that ZnO, AZO OMO structure show the crystalline peak. Average transmittance of visible region was over 75%, while that of infrared region was under 20%. Energy band gap of OMO layer was increased with increasing thickness of Ag layer. As a result total transmittance was decreased.

서킷 웨이트트레이닝이 노인들의 등속성 근력과 신체구성에 미치는 영향 (Effects of Circuit Weight Training on Isokinetic Muscle Strength and Body Composition in elderly)

  • 장정훈;정동혁
    • The Journal of Korean Physical Therapy
    • /
    • 제15권4호
    • /
    • pp.398-411
    • /
    • 2003
  • The purpose of this study was to investigate the effects of circuit weight training(CWT) on isokinetic muscle strength and body composition in elderly. The subjects who engaged in this experiment exercised at $40\%$ of 1-RM, 12 repetitions, followed by 15 sec as the subject moved to the each break training program which was consist of the circuit of 10 stations performed on 3 set a day, circuits 3 days a week during 10 weeks. The assessment of isokinetic factor was in concentric flexors and extensors of right and left knee joint. Tests were performed on the Cybex 770 Isokinetic Dynamometer and body composition were estimated the three parts of chest, abdomen and anterior thigh by using skinfold caliper, calculated the average and followed by Seri and Brozek way. Statistical analysis were performed using analysis of variance paired t-test, accepting level for all significant was above ${\alpha}=.05$ and ${\alpha}=.01$. Following is as a result of 10 weeks circuit weight training. 1. At the $60_{\circ}$ /sec, the right and left knee isokinetic concentric flexors and extensors peak torque increased significantly(p<.01). 2. At the $180_{\circ}$ /sec, the right and left knee isokinetic concentric flexors and extensors peak torque increased significantly(p<.01). 3. At the $60_{\circ}$ /sec, the right and left knee isokenetic concentric flexors and extensors average power increased significantly(p<.05, p<.01) and at the $180_{\circ}$ /sec, the right extensors didn't show any statistical significant. 4. At the $60_{\circ}$ /sec, the right and left knee Isokinetic concentric flexors and extensors total work increased significantly(p<.05, p<.01) but at the $180_{\circ}$ /sec right concentric flexors didn't show any statistical significant. 5. The body composition changed significantly(p<.01). These results suggest that 10 weeks circuit weight training increases the peak torque, average power, total work significantly and decreases the $\%$body fat significantly.

  • PDF

Plugger temperature of cordless heat carriers according to the time elapsed

  • Chang, Hoon-Sang;Park, Se-Hee;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • 제43권1호
    • /
    • pp.12.1-12.7
    • /
    • 2018
  • Objective: The purpose of this study was to measure the temperature of the plugger tip of 3 cordless heat carriers set at $200^{\circ}C$. Materials and Methods: Pluggers of the same taper (0.06, 0.08, 0.10) and similar tip sizes (sizes of 50 and 55) from 3 cordless heat carriers, namely SuperEndo-${\alpha}^2$(B & L Biotech), Friendo (DXM), and Dia-Pen (Diadent), were used and an electric heat carrier, System B (SybronEndo), was used as the control. The plugger tips were covered with customized copper sleeves, heated for 10 seconds, and the temperature was recorded with a computerized measurement system attached to a K-type thermometer at room temperature (n = 10). The data were analyzed with 2-way analysis of variance at a 5% level of significance. Results: The peak temperature of the plugger tips was significantly affected by the plugger taper and by the heat carrier brand (p < 0.05). The peak temperature of the plugger tips was between $177^{\circ}C$ and $325^{\circ}C$. The temperature peaked at $207^{\circ}C-231^{\circ}C$ for the 0.06 taper pluggers, $195^{\circ}C-313^{\circ}C$ for the 0.08 taper pluggers, and $177^{\circ}C-325^{\circ}C$ for the 0.10 taper pluggers. Only 5 of the 12 plugger tips showed a temperature of $200^{\circ}C{\pm}10^{\circ}C$. The time required to reach the highest temperature or $200^{\circ}C{\pm}10^{\circ}C$ was at least 4 seconds. Conclusion: When using cordless heat carriers, clinicians should pay attention to the temperature setting and to the activation time needed to reach the intended temperature of the pluggers.

남항진 파랑 스펙트럼 정보를 이용한 대표 스펙트럼 매개변수 추정 및 분석 (Parameter Estimation and Fitting Error Analysis of the Representative Spectrums using the Wave Spectrum off the Namhangjin, East Sea)

  • 조홍연;정원무;오상호;백원대
    • 한국해안·해양공학회논문집
    • /
    • 제32권5호
    • /
    • pp.363-371
    • /
    • 2020
  • 우리나라 동해 남항진 해역에서 관측한 고파 파랑 스펙트럼 정보를 이용하여 수정 BM 스펙트럼과 JONSWAP 스펙트럼의 매개변수를 추정하였다. BM 스펙트럼의 매개변수 추정결과는 1.04, 0.27로 대푯값으로 제시된 1.098, 0.30과 유사하였으나 통계적으로는 유의미한 차이를 보였다. 한편 JONSWAP 스펙트럼의 경우에는 첨두증대계수의 값이 통상적으로 적용되는 값인 3.3보다 매우 작은 1.4로 추정되었다. 두 스펙트럼의 적합 RMS 오차 차이는 0.2 정도로 미미한 수준이었으나, 두 스펙트럼 모두 첨두주파수보다 큰 주파수 영역에서의 에너지가 표준 스펙트럼 형태에 비해 상대적으로 완만하게 감소하는 양상을 보였다.

견갑면에서의 견관절 외전정도에 따른 등속성회전운동의 근력 평가 (An Evaluation for Isokinetic Strength During Shoulder Rotation Movement in the Scapular Plane with Various Abduction)

  • 최재원;김수민;김현애;김경;황보각;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제12권2호
    • /
    • pp.95-105
    • /
    • 2000
  • Glenohumeral internal and external rotation with shoulder abducted in the frontal plane often causes impingement of the supraspinatus tendon. whereas similar activity in scapular plane does not cause impingement. The Purpose of this study was to determine if assessment among the three positions as 30 degrees, 60 degrees, 90 degrees abduction in the sitting position of the scapular plane could be affected the comparison between intemal and external peak torque, total work, average power. In this study, Isokinetic shoulder rotational strength was evaluated in twenty healthy male university students, using the Cybex NORMTM System (CYBEX Division of LUMEX, Inc., Ronkonkoma, New York). Test data was gathered in the plane of the scapular, 30 degrees of horizontal flexion anterior to coronal plane, and the subjects performed the test with the arm 30, 60, and 90degrees abducted in the sitting position. also, test speed was set at deg/sec. Statistical analysis was performed using SPSS 7.5 for Windows software and mean and standard deviations were calculated. ANOVA was used to analyze the difference of the values in the three test positions. A paired t-test was used of examining the difference in the means peak torque between external and internal rotation. Not any significant difference was found among three abduction positions in scapular plane, even though there was a consistent pattern of greater strength in the abducted position of 60 degrees. Internal relation strength peak torque and total work were greater than those of external rotation in every test positions.

  • PDF

몽골의 가정용 PV-ES 하이브리드 시스템 개발을 위한 연구 (The Study on Development of PV-ES hybrid system for Mongolian Household)

  • ;;박준형
    • 전기학회논문지
    • /
    • 제66권12호
    • /
    • pp.1905-1912
    • /
    • 2017
  • In recent years, Ulaanbaatar, a capital of Mongolia has witnessed major problem that air quality reaches hazardous level during the winter season. Coal combustion for heating of every house in "Ger" district is main reason. One way to reduce the air pollution is mass usage of electric heater. However, there are several difficulties such as overload and degradation of transformers and other equipment used in distribution and transmission systems as well as power shortage occurrence in evening peak period due to residential consumption. This study aims to contribute for solving the air pollution and power shortage problem in Mongolia. One possible solution could be distributed generation (DG) with photovoltaic (PV) penetration. In this study, PV with energy storage (ES) hybrid system to reduce peak load is analyzed. We proposed the suitable structure of PV-ES hybrid for Mongolian household, and suggested several operation scenarios. Optimal operation algorithm is carried out based on a comparison aspect from economical, grid impact and PV penetration possibility. The economic analyse shows annual income of 520USD, and has a payback period of 8 years for selected scenario. The proposed PV-ES system structure is verified by experimentation set on the building rooftop in city center. The suggested scenario is planned to apply for system in further research.

전기화학법을 이용한 DNA Hybridization 검출 센서의 개발 및 특성 해석 (Development of DNA Hybridization Detection Sensors and Analysis of Characteristics Using Electrochemical methods)

  • 옥진영;김도균;장정수;권영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.260-262
    • /
    • 2002
  • The determination of DNA hybridization can apply the molecular biology research. clinic diagnostics. bioengineering, environment monitoring, food science and other application area. So, The determination of hybridization is very important for the improvement of DNA detection system. In this study, we report the characterization of the DNA hybridization by the electricalchemical methods. The probe oligonucleotide was used to determine the amount of target oligonucleotide in solution using Methylen Blue(MB) as the electrochemical indicators. The cathodic peak currents($I_{peak}$) of MB were linearly related to the concentration of the target oligonucleotide sequence in the range $1[{\mu}M]{\sim}0.1[{\mu}M]$. The detection limit of this approach was 0.01[nM]. As a result, the match oligonucleotide(CR-1) was most stable state and the peak of redox current measured by DNA hybridization detection sensors by using electrochemical method seem to be similar to 1-mer terminal mismatch oligonucleotide(MR-3). The MR-2, MR-3, MR-22 and MR-33 have each mismatching sequence of central and terminal. With this set the role of point mutations was to be investigated. Terminal mismatch oligonucleotide (MR-3, 33) is shown more stable state than central mismatch oligonucleotide(MR-2, 22). And 1-mer mismatch oligonucleotide(MR-2 or 3) is shown more stable state than 2-mer mismatch oligonucleotide(MR-22 or 33).

  • PDF

Vertical Ground Reaction Force Asymmetry in Prolonged Running

  • Ryu, Ji-Seon
    • 한국운동역학회지
    • /
    • 제28권1호
    • /
    • pp.29-35
    • /
    • 2018
  • Objective: The purpose of this study was to determine the asymmetry of vertical ground reaction force (GRF) components between dominant and non-dominant legs in rested and fatigued states in prolonged running. Method: Twenty healthy men, heel strikers, were included (age: $24.00{\pm}5.0years$; height: $176.1{\pm}6.0cm$; body mass: $69.0{\pm}6.0kg$) in this study. Subjects ran on an instrumented treadmill for 130 minutes. During treadmill running, GRF data (1,000 Hz) were collected for 20 strides at five minutes (rested) and 125 minutes (fatigued) running while they were unaware of collecting data. Asymmetry indexes (ASI) were calculated to quantify the asymmetry magnitude in rested and fatigued states. Paired t-test was used to verify the differences between dominant and non-dominant legs in rested and fatigued states. In addition, one-way repeated measure analysis of variance was applied for comparison of ASI of both states. The level of significance was set at p < .05. Results: Passive force peak magnitude, loading rate, and impulse affecting the development of running injury were found significantly greater in dominant leg than in non-dominant leg at rested state (p < .05). However, passive force peak time and active force peak magnitude were found significantly different between legs in fatigued state (p < .05). To determine changes in percentage of asymmetry between legs in both states, ASI was used. ASI for all variables increased in fatigued state; however, no significant differences were found between both states. Conclusion: This study found that fatigue did not affect differences in vertical GRF between dominant and non-dominant legs and asymmetry changes.

Optimal wind-induced load combinations for structural design of tall buildings

  • Chan, C.M.;Ding, F.;Tse, K.T.;Huang, M.F.;Shum, K.M.;Kwok, K.C.S.
    • Wind and Structures
    • /
    • 제29권5호
    • /
    • pp.323-337
    • /
    • 2019
  • Wind tunnel testing technique has been established as a powerful experimental method for predicting wind-induced loads on high-rise buildings. Accurate assessment of the design wind load combinations for tall buildings on the basis of wind tunnel tests is an extremely important and complicated issue. The traditional design practice for determining wind load combinations relies partly on subjective judgments and lacks a systematic and reliable method of evaluating critical load cases. This paper presents a novel optimization-based framework for determining wind tunnel derived load cases for the structural design of wind sensitive tall buildings. The peak factor is used to predict the expected maximum resultant responses from the correlated three-dimensional wind loads measured at each wind angle. An optimized convex hull is further developed to serve as the design envelope in which the peak values of the resultant responses at any azimuth angle are enclosed to represent the critical wind load cases. Furthermore, the appropriate number of load cases used for design purposes can be predicted based on a set of Pareto solutions. One 30-story building example is used to illustrate the effectiveness and practical application of the proposed optimization-based technique for the evaluation of peak resultant wind-induced load cases.