• 제목/요약/키워드: peak power

검색결과 2,626건 처리시간 0.035초

전류모드제어 방식을 이용하는 컨버터의 모델링 (Modeling of a Converter Utilizing Current Mode Control)

  • 정영석;이준영;강정일;윤명중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.275-278
    • /
    • 1998
  • The mathematical interpretation of a practical sampler which is useful to obtain the small signal models for the peak and average current mode controls is proposed. Due to the difficulties in applying the Shannon's sampling theorem to the analysis of sampling effects embedded in the current mode control, several different approaches have been reported. However, these approaches require the information of the inductor current in a discrete expression, which restricts the application of the reported method only to the peak current mode control. In this paper, the mathematical expressions of sampling effects on a current loop which can directly apply the Shannon's sampling theorem are newly proposed, and applied to the modeling of the peak current mode control. By the newly derived models of a practical sampler, the models in a discrete time domain and a continuous time domain are obtained. It is expected that the derived models are useful for the control loop design of power supplies. The effectiveness of the derived models are verified through the simulation and experimental results.

  • PDF

공압 쿠션 실린더의 충격압 흡수를 위한 스프링형 니들밸브의 동특성에 관한 연구 (Simulation Study on Dynamic Analysis of Spring Type Needle Valve to Absorb Surge Pressure in Pneumatic Cushion Cylinder)

  • 이재구;;이준;이재천;신현명
    • 유공압시스템학회논문집
    • /
    • 제2권1호
    • /
    • pp.15-22
    • /
    • 2005
  • The purpose of this study is to find the effective dynamic characteristics of an improved pneumatic cushion cylinder with a spring type needle valve. The dynamic model represented the peak pressure control method when the pneumatic cushion cylinder is moving forward or backward in the horizontal direction. It was found from the simulation results that the peak pressure in the cushion chamber is affected by the spring, which helps to understand the performance of the pneumatic cushion cylinder and to improve or design a better cushion needle valve component. From the simulation results, the stability of pneumatic cushion cylinder with a spring type needle valve was superior and its cushion capability was also better than that without the spring.

  • PDF

주상변압기 최대부하 추정을 위한 수용가 사용전력량 예측 (Working Electrical Energy Forecasting for Peak Load Estimation of Distribution Transformer)

  • 박창호;조성수;김재철;김두봉;윤상윤;이동준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.929-931
    • /
    • 1998
  • This paper describes the peak load forecasting technique of distribution transformers with correlation equation. While customers are demanding safe energy supply, conventional correlation equation that is used for load management of distribution transformers in domestic has some problems. To get accurate correlation equation, se-correlation equation were examined using new collected using the measuring instrument dev for this study. It was recognized that the qua equation was the most accurate for peak forecasting from working electrical energy.

  • PDF

국내 전력수급 방안 (Electric Power Supply & Demand measures in korea)

  • 이기선
    • 기술사
    • /
    • 제44권2호
    • /
    • pp.29-33
    • /
    • 2011
  • In recent years, maximum electric power demand has been increasing steadily. But, Electric Power Supply & Demand problem is occurring due to lack of electric power reserve ratio caused by electric power peak. For this reason, I investigated the current status of the Electric Power Supply & Demand and established Electric Power Supply & Demand and established Electric Power Supply & Demand measures. I will expect that this paper will be contributed balanced and stable Electric Power Supply & Demand management.

  • PDF

사용량 패턴분석을 통한 패턴분석 DR 프로그램 운영방안에 대한 연구 (A Study on the DR program operation method based on the pattern analysis)

  • 강중철;이현우
    • Journal of the Korean Data and Information Science Society
    • /
    • 제20권2호
    • /
    • pp.283-292
    • /
    • 2009
  • 최근 전반적인 산업의 급진적인 발전으로 인해 전력사용량도 급속도로 증가하고 있다. 그래서 (주)한국전력에서도 기본요금의 12개월 연동제를 실시하여 전기요금을 피크전력 중심으로 대폭 인상하여 전력사용 수용가의 최대 수요전력을 억제하는 요금정책을 시행하는 등 꾸준히 증가하고 있는 전력수요에 효율적인 대응전략을 수립하고 있다. 본 연구에서는 이러한 전략중의 하나인 DR프로그램을 효율적으로 운영하기 위해서 필수적으로 사용되는 CBL방법을 실제 전력 사용량의 분석을 통해 비교분석하고, 이를 바탕으로 효율적인 DR프로그램의 운영방안을 제시 하고자 한다.

  • PDF

A Simple Structure of Zero-Voltage Switching (ZVS) and Zero-Current Switching (ZCS) Buck Converter with Coupled Inductor

  • Wei, Xinxin;Luo, Ciyong;Nan, Hang;Wang, Yinghao
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1480-1488
    • /
    • 2015
  • In this paper, a revolutionary buck converter is proposed with soft-switching technology, which is realized by a coupled inductor. Both zero-voltage switching (ZVS) of main switch and zero-current switching (ZCS) of freewheeling diode are achieved at turn on and turn off without using any auxiliary circuits by the resonance between the parasitic capacitor and the coupled inductor. Furthermore, the peak voltages of the main switch and the peak current of the freewheeling diode are significantly reduced by the coupled inductor. As a result, the proposed converter has the advantages of simple circuit, convenient control, low consumption and so on. The detailed operation principles and steady-state analysis of the proposed ZVS-ZCS buck converter are presented, and detailed power loss analysis and some simulation results are also included. Finally, experimental results based on a 200-W prototype are provided to verify the theory and design of the proposed converter.

전력계통에 있어서 분산형 연료전지 발전시스템의 최적 도입계획에 관한 연구 (A Study on the Optimal Planning for Dispersed Fuel Cell Generation Systems in Power Systems)

  • 노대석;심헌;오용택;최재석;차준민
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권6호
    • /
    • pp.265-274
    • /
    • 2001
  • Recently, the operation of power systems has become more difficult because the peak demand load is increasing continuously and the daily load factor is getting worse and worse. Also, the consideration of deregulation and global environment in electric power industry is required. In order to overcome those problems, a study on the planning and operation in power systems of dispersed generating sources such as fuel cell systems, photovoltaic systems and wind power systems, has been performed energetically. This paper presents a method for determining an optimal operation strategy of dispersed co-generating sources, especially fuel cell generation systems, considering thermal supply as well as electric power supply. In other words, the optimal operation of those sources can be determined easily by the principle of equal incremental fuel cost and the thermal merit of those sources can be also evaluated quantitatively through Kuhn-Tucker's optimal conditions. In additions, an priority method using the comparison of total cost at the peak load time interval is presented in order ot select the optimal locations of those sources. The validity of the proposed algorithms is demonstrated using a model system.

  • PDF

새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성 (Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber)

  • 성치호;허영환;문상필;박한석
    • 전기학회논문지P
    • /
    • 제65권2호
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

유도형(誘導型) Pulsed Power 전원을 이용한 CO2 레이저 동작 특성에 관한 연구 (A Study on Operating Characteristics of the CO2 Laser with Inductively Pulsed Power System)

  • 김근용;민병대;김용철;이유수;정현주;김희제
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1710-1713
    • /
    • 2002
  • Recently, the pulsed power system has been used to many applications. Such as remediation of environmental hazards, food sterilization, air pollution control E/P (Electrostatic Precipitator), DeNOx/DeSOx power system, ozone generator, high energy physics, and other power source applications. A pulse energy efficiency for load depends on the rising time, peak value. Pulse duration and impedance matching etc. The pulsed power system generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, we investigated operating characteristics of the CO2 laser using an inductively pulsed power system.

  • PDF

HAUSAT-2 위성의 전력계 개발 및 검증 (Development and Validation of HAUSAT-2 Nanosatellite EPS)

  • 김동운;장영근;문병영
    • 한국항공우주학회지
    • /
    • 제34권4호
    • /
    • pp.89-101
    • /
    • 2006
  • 본 논문에서는 HAUSAT-2 전력계의 설계와 각 모드별로 에너지 평형 해석을 통한 전력계 설계의 타당성을 검증하였다. 태양전지판은 GaAs 셀을 사용하였고 디지털 방식의 최대 전력 추적기를 채택하였다. 배터리 팩은 4개의 Li-Ion 셀로 구성하였고 최대 전력 추적기와 배터리 충전 조절기로 배터리 충전 기능을 구현하였다. 전력 제어기는 DC-DC 변환기로 요구되는 전압을 출력하고 상용 IC 및 MOSFET으로 이루어진 전력 분배기가 서브시스템 및 탑재체에 전력을 분배시킨다. 전력생성 분석은 다양한 승교점 지방시(LTAN)를 가지는 궤도를 고려하여 수행하였으며, 이 중 HAUSAT-2의 임무 수행에 적합한 궤도를 선정하여 모드별 전력 사항을 반영하여 에너지 평형 해석(EBA)을 진행하였다.