• Title/Summary/Keyword: peak power

Search Result 2,626, Processing Time 0.038 seconds

Earthquake risk assessment of concrete gravity dam by cumulative absolute velocity and response surface methodology

  • Cao, Anh-Tuan;Nahar, Tahmina Tasnim;Kim, Dookie;Choi, Byounghan
    • Earthquakes and Structures
    • /
    • v.17 no.5
    • /
    • pp.511-519
    • /
    • 2019
  • The concrete gravity dam is one of the most important parts of the nation's infrastructure. Besides the benefits, the dam also has some potentially catastrophic disasters related to the life of citizens directly. During the lifetime of service, some degradations in a dam may occur as consequences of operating conditions, environmental aspects and deterioration in materials from natural causes, especially from dynamic loads. Cumulative Absolute Velocity (CAV) plays a key role to assess the operational condition of a structure under seismic hazard. In previous researches, CAV is normally used in Nuclear Power Plant (NPP) fields, but there are no particular criteria or studies that have been made on dam structure. This paper presents a method to calculate the limitation of CAV for the Bohyeonsan Dam in Korea, where the critical Peak Ground Acceleration (PGA) is estimated from twelve sets of selected earthquakes based on High Confidence of Low Probability of Failure (HCLPF). HCLPF point denotes 5% damage probability with 95% confidence level in the fragility curve, and the corresponding PGA expresses the crucial acceleration of this dam. For determining the status of the dam, a 2D finite element model is simulated by ABAQUS. At first, the dam's parameters are optimized by the Minitab tool using the method of Central Composite Design (CCD) for increasing model reliability. Then the Response Surface Methodology (RSM) is used for updating the model and the optimization is implemented from the selected model parameters. Finally, the recorded response of the concrete gravity dam is compared against the results obtained from solving the numerical model for identifying the physical condition of the structure.

Wind-excited stochastic vibration of long-span bridge considering wind field parameters during typhoon landfall

  • Ge, Yaojun;Zhao, Lin
    • Wind and Structures
    • /
    • v.19 no.4
    • /
    • pp.421-441
    • /
    • 2014
  • With the assistance of typhoon field data at aerial elevation level observed by meteorological satellites and wind velocity and direction records nearby the ground gathered in Guangzhou Weather Station between 1985 and 2001, some key wind field parameters under typhoon climate in Guangzhou region were calibrated based on Monte-Carlo stochastic algorithm and Meng's typhoon numerical model. By using Peak Over Threshold method (POT) and Generalized Pareto Distribution (GPD), Wind field characteristics during typhoons for various return periods in several typical engineering fields were predicted, showing that some distribution rules in relation to gradient height of atmosphere boundary layer, power-law component of wind profile, gust factor and extreme wind velocity at 1-3s time interval are obviously different from corresponding items in Chinese wind load Codes. In order to evaluate the influence of typhoon field parameters on long-span flexible bridges, 1:100 reduced-scale wind field of type B terrain was reillustrated under typhoon and normal conditions utilizing passive turbulence generators in TJ-3 wind tunnel, and wind-induced performance tests of aero-elastic model of long-span Guangzhou Xinguang arch bridge were carried out as well. Furthermore, aerodynamic admittance function about lattice cross section in mid-span arch lib under the condition of higher turbulence intensity of typhoon field was identified via using high-frequency force-measured balance. Based on identified aerodynamic admittance expressions, Wind-induced stochastic vibration of Xinguang arch bridge under typhoon and normal climates was calculated and compared, considering structural geometrical non-linearity, stochastic wind attack angle effects, etc. Thus, the aerodynamic response characteristics under typhoon and normal conditions can be illustrated and checked, which are of satisfactory response results for different oncoming wind velocities with resemblance to those wind tunnel testing data under the two types of climate modes.

Review paper: Application of the Pulsed Eddy Current Technique to Inspect Pipelines of Nuclear Plants

  • Park, D.G.;Angani, C.S.;Kishore, M.B.;Vertesy, G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.18 no.3
    • /
    • pp.342-347
    • /
    • 2013
  • Local wall thinning in pipelines affects the structural integrity of industries, such as nuclear power plants (NPPs). In the present study, a development of pulsed eddy current (PEC) technology that detects the wall thinning of pipelines covered with insulation is reviewed. The methods and experimental results, which have two kinds of probe with a single and double core, were compared. For this purpose, the single and double core probes having one and two excitation coils have been devised, and the differential probe with two Hall sensors has been fabricated to measure the wall thinning in insulated pipelines. The test sample is a stainless steel having different thickness, laminated by plastic insulation to simulate the pipelines in NPPs. The excitation coils in the probe is driven by a rectangular current pulse, the difference of two Hall sensors has been measured as a resultant PEC signal. The peak value of the detected signal is used to describe the wall thinning. The double core probe has better performance to detect the wall thinning covered with insulation; the single core probe can detect the wall thinning up to an insulation thickness of 18 mm, whereas the double probe can detect up to 25 mm. The results show that the double core PEC probe has the potential to detect the wall thinning in an insulated pipeline of the NPPs.

Cavity-Length Detuning Characteristics of a Hybridly Mode-Locked Ultrashort Pulse Dye Laser (결합형 모드록킹 극초단 색소레이저의 공진기 길이변화 특성)

  • 서정철;정영붕;김동호
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.1
    • /
    • pp.22-27
    • /
    • 1990
  • The cavity-length detuning characteristics of the hybridly mode-locked dye laser have been studied with a collinear autocorrelator. In the optimum condition, the pulse width is 0.65 ps about three times as short as that of the synchronously mode-locked dye laser. As the cavity length is increased, the pulse width becomes broader than that at the optimum cavity length because of the effect of spontaneous emission. Also, the spectrum width becomes broad, therefore the time bandwidth product ($\Deltat\Deltav$) is increased. The peak power of autocorrelation is maximum at $\Deltat=5.0\umm$ longer than the optimum cavity length. On the other hand, as the cavity length is decreased, the pulse width becomes broader and the satellite pulses appear because of the gain recovery. Also the spectrum width becomes narrower than that at the optimum cavity length. In particular, at the mismatched cavity length the center of the lasing spectrum moves to shorter wavelengths. ngths.

  • PDF

A study on corrosion resistance and surface properties of AZ31 alloy according to Ca-GP addition during PEO treatment (PEO 처리시 Ca-GP첨가에 따른 AZ31합금의 내식성 및 표면특성에 관한 연구)

  • Lee, Jun-Su;Park, Je-Shin;Park, Il-Song
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.5
    • /
    • pp.238-247
    • /
    • 2021
  • PEO (plasma electrolytic oxidation) was applied to modify the surface of AZ31 magnesium alloy in this study. The mixed solution of sodium hydroxide (NaOH) and sodium silicate (Na2SiO3) was used as the electrolyte, and 0 - 0.05 g/L of Ca-GP (Glycerol Phosphate Calcium salt) was added in the electrolyte as an additive. PEO treatment was conducted at a current density of 30mA/cm2 for 5 minutes using a DC power supply. The surface properties were identified by SEM, XRD and surface roughness analyses, and the corrosion resistance was evaluated by potentiodynamic polarization and immersion tests. In addition, the biocompatibility was evaluated by immersion test in SBF solution. As the concentration of Ca-GP was increased, the surface morphology was denser and more uniform, and the amount of Ca and the thickness of oxide layer increased. Only Mg peak was observed in XRD analysis due to very thin oxide layer. The corrosion resistance of PEO-treated samples increased with the concentration of Ca-GP in comparision with the untreated sample. In particular, the highest corrosion resistance was identified at the group of 0.04g Ca-GP through potentiodynamic polarization and immersion tests in saline solution (0.9 wt.%NaCl). During the immersion in saline solution, pH rapidly increased at the beginning of immersion period due to rapid corrosion, and then increase rate of pH decreased. However, the pH value in the SBF temporarily increased from 7.4 to 8.5 during the day, then decreased due to the inhibition of corrosion with HA(hydroxyapatite) formation.

Design and Fabrication of an L-Band Digital TR Module for Radar (레이다용 L대역 디지털 송수신모듈 설계 및 제작)

  • Lim, Jae-Hwan;Park, Se-Jun;Jun, Sang-Mi;Jin, Hyung-Suk;Kim, Kwan-Sung;Kim, Tae-Hun;Kim, Jae-Min
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.11
    • /
    • pp.857-867
    • /
    • 2018
  • Active array radar is evolving into digital active array radar. Digital active array radar has many advantages for making several simultaneous radar beams from the digital receive data of each element. A digital-type transceiver(TR) module is suitable for this goal in radar. In this work, the design results of an L-band digital TR module are presented to verify the possibility of fabrication for a digital active array antenna. This L-band digital TR module consists of a gallium-nitride-type HPA to achieve a more than 350-W peak output power and one-chip transceivers that include a digital waveform generator and analog digital converter. The receiving gain was 47 dB, the noise figure was less than 2 dB, and the final output type of the four channel receiving paths was one optic signal.

A Low-Voltage Self-Startup DC-DC Converter for Thermoelectric Energy Harvesting (열에너지 수확을 위한 저전압 자율시동 DC-DC 변환기)

  • Jeong, Hyun-Jin;Kim, Dong-Hoon;Kim, Hoe-Yeon;Yoon, Eun-Jung;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.520-523
    • /
    • 2016
  • This paper describes a DC-DC converter with MPPT control for thermoelectric energy harvesting. The designed circuit converts low voltage harvested from a thermoelectric generator into higher voltage for powering a load. A start-up circuit supplies VDD to a controller, and the controller turns on and off a NMOS switch of a main-boost converter. The converter supplies the boosted voltage to the load through the switch operation. Bulk-driven comparators can do the comparison under low voltage condition and are used for voltage regulation. Also, bulk-driven comparators raise system's efficiency. A peak conversion efficiency of 76% is achieved. The proposed circuit is designed in a 0.35um CMOS technology and its functionality has been verified through simulations. The designed chip occupies $933um{\times}769um$.

  • PDF

PAPR Improvement of OFDM-CQAM System Through Optimum Position Impulse Insertion Scheme in Frequency Domain (주파수영역 최적 위치 임펄스 삽입기법에 의한 OFDM-CQAM 시스템의 PAPR 개선)

  • Kwak, Jae-Min
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.3
    • /
    • pp.258-263
    • /
    • 2019
  • OFDM is popular digital communication method due to its immunity to multipath fading and capability of high speed data transmission, but it has disadvantage of high PAPR in transmission signal when many subcarrier modulated signal are added to the same phase. When frequency domain high amplitude impulse is inserted before IFFT in OFDM transmitter, the PAPR of OFDM signal in tme domain can be effectively reduced. In this paper, the degree of PAPR improvement of OFDM communication system with CQAM subcarrier modulation is analysed by adopting impulse insertion technique before IFFT of transmitter. Furthermore, it is verified that additional PAPR performance improvement can be obtained by finding optimum position of impulse insertion for maximizing PAPR reduction. Through computer simulation, the degree of PAPR improvement according to amplitude and position of inserted impulse is superior to conventional technique in OFDM-CQAM system.

Oxygenation Index in the First 24 Hours after the Diagnosis of Acute Respiratory Distress Syndrome as a Surrogate Metric for Risk Stratification in Children

  • Kim, Soo Yeon;Kim, Byuhree;Choi, Sun Ha;Kim, Jong Deok;Sol, In Suk;Kim, Min Jung;Kim, Yoon Hee;Kim, Kyung Won;Sohn, Myung Hyun;Kim, Kyu-Earn
    • Acute and Critical Care
    • /
    • v.33 no.4
    • /
    • pp.222-229
    • /
    • 2018
  • Background: The diagnosis of pediatric acute respiratory distress syndrome (PARDS) is a pragmatic decision based on the degree of hypoxia at the time of onset. We aimed to determine whether reclassification using oxygenation metrics 24 hours after diagnosis could provide prognostic ability for outcomes in PARDS. Methods: Two hundred and eighty-eight pediatric patients admitted between January 1, 2010 and January 30, 2017, who met the inclusion criteria for PARDS were retrospectively analyzed. Reclassification based on data measured 24 hours after diagnosis was compared with the initial classification, and changes in pressure parameters and oxygenation were investigated for their prognostic value with respect to mortality. Results: PARDS severity varied widely in the first 24 hours; 52.4% of patients showed an improvement, 35.4% showed no change, and 12.2% either showed progression of PARDS or died. Multivariate analysis revealed that mortality risk significantly increased for the severe group, based on classification using metrics collected 24 hours after diagnosis (adjusted odds ratio, 26.84; 95% confidence interval [CI], 3.43 to 209.89; P=0.002). Compared to changes in pressure variables (peak inspiratory pressure and driving pressure), changes in oxygenation (arterial partial pressure of oxygen to fraction of inspired oxygen) over the first 24 hours showed statistically better discriminative power for mortality (area under the receiver operating characteristic curve, 0.701; 95% CI, 0.636 to 0.766; P<0.001). Conclusions: Implementation of reclassification based on oxygenation metrics 24 hours after diagnosis effectively stratified outcomes in PARDS. Progress within the first 24 hours was significantly associated with outcomes in PARDS, and oxygenation response was the most discernable surrogate metric for mortality.

Operating characteristics of a superconducting DC circuit breaker connected to a reactor using PSCAD/EMTDC simulation

  • Kim, Geon-woong;Jeong, Ji-sol;Park, Sang-yong;Choi, Hyo-sang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.23 no.3
    • /
    • pp.51-54
    • /
    • 2021
  • The DC system has less power loss compared to the AC system because there is no influence of frequency and dielectric loss. However, the zero-crossing point of the current is not detected in the event of a short circuit fault, and it is difficult to interruption due to the large fault current that occurs during the opening, so the reliability of the DC breaker is required. As a solution to this, an LC resonance DC circuit breaker combined a superconducting element has been proposed. This is a method of limiting the fault current, which rises rapidly in case of a short circuit fault, with the quench resistance of the superconducting element, and interruption the fault current passing through the zero-crossing point through LC resonance. The superconducting current limiting element combined to the DC circuit breaker plays an important role in reducing the electrical burden of the circuit breaker. However, at the beginning of a short circuit fault, superconducting devices also have a large electrical burden due to large fault currents, which can destroy the element. In this paper, the reactor is connected to the source side of the circuit using PSCAD/EMTDC. After that, the change of the fault current according to the reactor capacity and the electrical burden of the superconducting element were confirmed through simulation. As a result, it was confirmed that the interruption time was delayed as the capacity of the reactor connected to the source side increased, but peak of the fault current decreased, the zero-crossing point generation time was shortened, and the electrical burden of the superconducting element decreased.