• Title/Summary/Keyword: peak power

Search Result 2,626, Processing Time 0.032 seconds

Modeling of a Converter Utilizing Current Mode Control (전류모드제어 방식을 이용하는 컨버터의 모델링)

  • 정영석;이준영;강정일;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.275-278
    • /
    • 1998
  • The mathematical interpretation of a practical sampler which is useful to obtain the small signal models for the peak and average current mode controls is proposed. Due to the difficulties in applying the Shannon's sampling theorem to the analysis of sampling effects embedded in the current mode control, several different approaches have been reported. However, these approaches require the information of the inductor current in a discrete expression, which restricts the application of the reported method only to the peak current mode control. In this paper, the mathematical expressions of sampling effects on a current loop which can directly apply the Shannon's sampling theorem are newly proposed, and applied to the modeling of the peak current mode control. By the newly derived models of a practical sampler, the models in a discrete time domain and a continuous time domain are obtained. It is expected that the derived models are useful for the control loop design of power supplies. The effectiveness of the derived models are verified through the simulation and experimental results.

  • PDF

Simulation Study on Dynamic Analysis of Spring Type Needle Valve to Absorb Surge Pressure in Pneumatic Cushion Cylinder (공압 쿠션 실린더의 충격압 흡수를 위한 스프링형 니들밸브의 동특성에 관한 연구)

  • Lee J.G.;Xiaofei Qin;Lee J.;Lee J.C.;Shin H.M.
    • Transactions of The Korea Fluid Power Systems Society
    • /
    • v.2 no.1
    • /
    • pp.15-22
    • /
    • 2005
  • The purpose of this study is to find the effective dynamic characteristics of an improved pneumatic cushion cylinder with a spring type needle valve. The dynamic model represented the peak pressure control method when the pneumatic cushion cylinder is moving forward or backward in the horizontal direction. It was found from the simulation results that the peak pressure in the cushion chamber is affected by the spring, which helps to understand the performance of the pneumatic cushion cylinder and to improve or design a better cushion needle valve component. From the simulation results, the stability of pneumatic cushion cylinder with a spring type needle valve was superior and its cushion capability was also better than that without the spring.

  • PDF

Working Electrical Energy Forecasting for Peak Load Estimation of Distribution Transformer (주상변압기 최대부하 추정을 위한 수용가 사용전력량 예측)

  • Park, Chang-Ho;Cho, Seong-Soo;Kim, Jae-Cheol;Kim, Du-Bong;Yun, Sang-Yun;Lee, Dong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.929-931
    • /
    • 1998
  • This paper describes the peak load forecasting technique of distribution transformers with correlation equation. While customers are demanding safe energy supply, conventional correlation equation that is used for load management of distribution transformers in domestic has some problems. To get accurate correlation equation, se-correlation equation were examined using new collected using the measuring instrument dev for this study. It was recognized that the qua equation was the most accurate for peak forecasting from working electrical energy.

  • PDF

Electric Power Supply & Demand measures in korea (국내 전력수급 방안)

  • Lee, Ki-Seon
    • Journal of the Korean Professional Engineers Association
    • /
    • v.44 no.2
    • /
    • pp.29-33
    • /
    • 2011
  • In recent years, maximum electric power demand has been increasing steadily. But, Electric Power Supply & Demand problem is occurring due to lack of electric power reserve ratio caused by electric power peak. For this reason, I investigated the current status of the Electric Power Supply & Demand and established Electric Power Supply & Demand and established Electric Power Supply & Demand measures. I will expect that this paper will be contributed balanced and stable Electric Power Supply & Demand management.

  • PDF

A Study on the DR program operation method based on the pattern analysis (사용량 패턴분석을 통한 패턴분석 DR 프로그램 운영방안에 대한 연구)

  • Kang, Jung-Chul;Lee, Hyun-Woo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.2
    • /
    • pp.283-292
    • /
    • 2009
  • Recently the stable electric power supply is threaten by the rapid development of all the industries consuming a lot of electric power, thus KEPCO is trying to establish the countermeasures to cope with this circumstance of uprising power consumption by running the efficient and flexible 12-month s price policy for the base price and raisin the electric power price remarkably in peak power consumption period to suppress the maximal power demand of consumers. To resolve these problems, this study propose the method calculating hourly CBL based on the hourly amount at non-event using the pattern of the amount of power consumption and propose the operation method of DR Program.

  • PDF

A Simple Structure of Zero-Voltage Switching (ZVS) and Zero-Current Switching (ZCS) Buck Converter with Coupled Inductor

  • Wei, Xinxin;Luo, Ciyong;Nan, Hang;Wang, Yinghao
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1480-1488
    • /
    • 2015
  • In this paper, a revolutionary buck converter is proposed with soft-switching technology, which is realized by a coupled inductor. Both zero-voltage switching (ZVS) of main switch and zero-current switching (ZCS) of freewheeling diode are achieved at turn on and turn off without using any auxiliary circuits by the resonance between the parasitic capacitor and the coupled inductor. Furthermore, the peak voltages of the main switch and the peak current of the freewheeling diode are significantly reduced by the coupled inductor. As a result, the proposed converter has the advantages of simple circuit, convenient control, low consumption and so on. The detailed operation principles and steady-state analysis of the proposed ZVS-ZCS buck converter are presented, and detailed power loss analysis and some simulation results are also included. Finally, experimental results based on a 200-W prototype are provided to verify the theory and design of the proposed converter.

A Study on the Optimal Planning for Dispersed Fuel Cell Generation Systems in Power Systems (전력계통에 있어서 분산형 연료전지 발전시스템의 최적 도입계획에 관한 연구)

  • Rho, Dae-Seok;Shim, Hun;Oh, Yong-Taek;Choi, Jae-Seok;Cha, Jun-Min
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.50 no.6
    • /
    • pp.265-274
    • /
    • 2001
  • Recently, the operation of power systems has become more difficult because the peak demand load is increasing continuously and the daily load factor is getting worse and worse. Also, the consideration of deregulation and global environment in electric power industry is required. In order to overcome those problems, a study on the planning and operation in power systems of dispersed generating sources such as fuel cell systems, photovoltaic systems and wind power systems, has been performed energetically. This paper presents a method for determining an optimal operation strategy of dispersed co-generating sources, especially fuel cell generation systems, considering thermal supply as well as electric power supply. In other words, the optimal operation of those sources can be determined easily by the principle of equal incremental fuel cost and the thermal merit of those sources can be also evaluated quantitatively through Kuhn-Tucker's optimal conditions. In additions, an priority method using the comparison of total cost at the peak load time interval is presented in order ot select the optimal locations of those sources. The validity of the proposed algorithms is demonstrated using a model system.

  • PDF

Characteristic of Three-Phase Voltage Type Soft-Switching Inverter using the Novel Active Auxiliary Resonant DC Link Snubber (새로운 액티브 보조 공진 DC 링크 스너버를 이용한 3상 전압형 소프트 스위칭 인버터의 특성)

  • Sung, Chi-Ho;Heo, Young-Hwan;Mun, Sang-Pil;Park, Han-Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.65 no.2
    • /
    • pp.114-121
    • /
    • 2016
  • This paper is Instant space vector PWM(Pulse Width Modulation)power conversion devices in switching power semiconductors from my generation to losses and switching when the voltage surge and current surge of electronic noise(EMI: Electro Magnetic Interference / RFI: Radio Frequency Interference)to effectively minimize the power soft-switching power conversion circuit topologies of auxiliary resonant DC tank for the purpose of high performance realization of the electric power conversion system by the high-speed switching of a semiconductor device(AQRDCT simultaneously : an active auxiliary resonance using auxiliary Quasi-resonant DC tank)DC link snubber switch has adopted a three-phase voltage inverter. AQRDCL proposed in this paper can reduce the effective and current peak stress of the power semiconductors of the auxiliary resonant snubber circuit compared to the conventional active-resonant DC link snubber, it is not necessary to install the clamp switch of the auxiliary resonant DC link, DC the peak current and power loss of the bus line can be reduced.

A Study on Operating Characteristics of the CO2 Laser with Inductively Pulsed Power System (유도형(誘導型) Pulsed Power 전원을 이용한 CO2 레이저 동작 특성에 관한 연구)

  • Kim, Geun-Yong;Min, Byoung-Dae;Kim, Yong-Cheol;Lee, Yu-Soo;Chung, Hyun-Ju;Kim, Hee-Je
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1710-1713
    • /
    • 2002
  • Recently, the pulsed power system has been used to many applications. Such as remediation of environmental hazards, food sterilization, air pollution control E/P (Electrostatic Precipitator), DeNOx/DeSOx power system, ozone generator, high energy physics, and other power source applications. A pulse energy efficiency for load depends on the rising time, peak value. Pulse duration and impedance matching etc. The pulsed power system generally required for short pulse duration and high peak value was forced to consider its volume and economy. In this paper, we investigated operating characteristics of the CO2 laser using an inductively pulsed power system.

  • PDF

Development and Validation of HAUSAT-2 Nanosatellite EPS (HAUSAT-2 위성의 전력계 개발 및 검증)

  • Kim, Dong-Un;Jang, Yeong-Geun;Mun, Byeong-Yeong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.89-101
    • /
    • 2006
  • This paper addresses Electrical Power Subsystem(EPS) design and verification of HAUSAT-2 small satellite through energy balance analysis(EBA) depending on individual operation modes. GaAs solar cells are used for satellite power generation and digital peak power tracking is implemented for EPS architecture. One battery pack is consisted of 4 Li-Ion cells. Battery charge is accomplished by peak power tracker and battery charge regulator. Power conditioning assembly uses three DC-DC converters, and power distribution assembly which consists of commercial IC and MOSFET switch distributes power to subsystems and payloads. The altitude of 650km and sun-synchronous LEO with various local time ascending node(LTAN) are considered in EBA.