• 제목/요약/키워드: peak oil

검색결과 277건 처리시간 0.023초

Incorporation of n-3 Long-chain Polyunsaturated Fatty Acids into Duck Egg Yolks

  • Chen, Tian-Fwu;Hsu, Jenn-Chung
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권4호
    • /
    • pp.565-569
    • /
    • 2003
  • The objective of this experiment was to determine the effects of different levels of refined cod liver oil (RCLO) on laying performance, n-3 polyunsaturated fatty acids composition (n-3 PUFAs) and the organoleptic evaluation of duck egg yolks. A total of 180 30 wk old laying Tsaiya ducks, at the beginning of peak production, were allotted into 6 treatments with 3 replicates each. Ducks were fed one of the 6 experimental diets, supplemented with 2% tallow (control) and graded levels of RCLO at 2, 3, 4, 5, and 6% to a corn-soybean diets, respectively, for 6 wks. All of the experimental diets were formulated to be both isocaloric and isonitrogenous. Feed and water were supplied ad libitum throughout the experimental period. The results indicated that the RCLO supplementation levels did not affect (p>0.05) egg production, egg mass, feed intake, feed efficiency or body weight change. Egg weight was the lightest when the ducks received the 6% RCLO diet. The eicosapentaenoic acid, docosahexaenoic acid, and total n-3 PUFAs contents in the yolks increased with increasing RCLO supplementation. The taste and general acceptability of the hard-boiled eggs were not significantly different among the treatments. However, a fishy flavor was much higher when ducks were fed diets supplemented with 5% and 6% RCLO diets.

Characterization of Bacteria Isolated from the Traditional Steeping Process and Their Application as Starters for the Production of Yugwa, a Korean Traditional Snack

  • Chang, Hyun-Joo;Lee, Seung-Jun;Lee, Myung-Ki;Cho, Yong-Jin;Kim, Hyun-Jung;Kim, Chong-Tae;Chun, Hyang-Sook
    • Food Science and Biotechnology
    • /
    • 제16권3호
    • /
    • pp.355-360
    • /
    • 2007
  • During the traditional production process of yugwa, a Korean traditional oil-puffed snack, three bacterial isolates, 12, 37, and B1 from waxy rice slurry were characterized by using the molecular techniques, and the quality of the yugwa prepared by using three isolates was examined in relation to physical and sensory properties. Isolates 37 and B1 were identified as Lactobacillus sp. by 16S rDNA sequence analysis, while isolate 12 was as Bacillus amyloliquefaciens by gyrA sequence analysis. Waxy rice inoculated with isolate 12 demonstrated the lowest hardness and the highest peak and [mal viscosity. Yugwa prepared from isolate 12-inoculated waxy rice indicated the lowest hardness and the highest volume expansion, the key characteristics of yugwa. This result presents the possibility for the use of a starter in the commercial production of yugwa and other rice-based snacks.

변압기 권선변형 진단에 적용하기 위한 LVI 시험기 개발 (The development of LVI tester for application of transformers winding deformation diagnosis)

  • 조국희;김광화
    • 조명전기설비학회논문지
    • /
    • 제16권5호
    • /
    • pp.97-103
    • /
    • 2002
  • 본 논문은 LVI 시험기를 개발하여 모델 변압기 및 유입식 변압기에 적용해 LVI 시험 분석기술을 개발하였다. LVI시험기는 본체, 터미널 박스 및 케이블로 구성하였고, ANSI규격에서 요구하는 출력특성을 갖도록 설계 제작하였다. 모델 변압기는 탭들을 만들어 변압기의 권선변형 모델을 만들 수 있도록 하였고, 유입식 변압기는 실제 현장에서 사용되는 3상 변압기이다. LVI 시험기는 펄스폭이 1000 ㎱ 이하의 파두 시간과 펄스 최대 전압 500 V로 제작되었다. LVI 시험기로써 실험을 실시하여 성능을 평가한 결과 측정된 파형 분석으로 권선의 축방향과 반경방향으로의 움직임을 구별할 수 있어 변압기 예방 진단에도 효과가 기대된다.

Parametric study on dynamic behavior of rectangular concrete storage tanks

  • Yazdanian, Mohsen;Fu, Feng
    • Coupled systems mechanics
    • /
    • 제6권2호
    • /
    • pp.189-206
    • /
    • 2017
  • Tanks are used to store a wide variety of liquids such as oil, gasoline and water. It is reported that, a large number of tanks have been damaged during severe earthquakes. Therefore, understanding their behavior under earthquake is an important subject for structural engineers. In this paper, a comprehensive study is presented on dynamic response of tanks. A parametric study has been completed on the rectangular storage tanks with aid of finite element method (FEM). Various parameters are investigated, such as; liquid height, density and earthquake with different peak ground acceleration (PGA). When investigating these parameters, modal and time history method is used. Six different earthquake records are used for time history analysis. The analysis results show that when the PGA increases by 10.7 times, the maximum displacements, stress, sloshing and base shear increase by 11.4, 22.6, 5.46 and 17.8 times, respectively and when the liquid height increases by two times, the absolute maximum values of stress, displacements, base shear and sloshing increase 1.65, 2.04, 2.05 and 1.34. Furthermore, values of sloshing increase with decrease in density.

저압 유도전동기에서 미소 부분방전 측정에 관한 연구 (A Study on the Measurement of Small Partial Discharges in a Low-voltage Induction Motor)

  • 길경석;송재용;서황동;황돈하;강동식;김용주
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.960-964
    • /
    • 2005
  • In this paper, we dealt with a partial discharge(PD) measurement method that has been accepted as an effective and non-destructive technique to estimate insulation performance of low-voltage electric and electronic devices. The PD measurement system Is composed of a coupling network, a low noise amplifier, and associated electronics. h shielded box Is adopted to make a better measurement environment against around noise. A low cut-off frequency of the coupling network estimated by a sinusoidal wave input was 125 kHz (-3 dB). Calibration tests on laboratory set-up have shown that the PD measurement system has a stable sensitivity of 10 mV/pC. In an application test oil a low-voltage three phase Induction motor (5 HP), we could detect 0.53 pC level of partial discharge at the applied voltage of AC 650 $V_{peak}$.

액체절연체(실리콘유) 유전정접의 온도및 주파수의존성 (The Dependence of Temperature and Frequency for the Dissipation Factor in Liquid Dielectrics)

  • 이돈희;소병문;이수원;김왕곤;홍진웅
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1993년도 추계학술대회 논문집
    • /
    • pp.85-89
    • /
    • 1993
  • Silicone oil exhibits the properies of both organic and inorganic substances and, thus, it has many superior properties such as higher thermal resistance and lower thermal oxidation level when compared to other dielectric liquids. In order to investigate the dielectric characteristics, dielectric liquids of viscosity 1 [cSt] is chosen as the specimen and experiment is performed in the temperature range of 20∼65 [$^{\circ}C$] and frequency range of 30∼1${\times}$10$\^$6/ [Hz] respectively. As a result, the observed linear decrease in dissipation factor at the frequency range below 3 [kHz] is due to the influence of frequency, whereas the increase in dissipation factor at higher frequency range is contributed by electrode's resistance. At a fixed frequency of 30 [kHz], increasing temperature results in higher peak value and wide width of the absorption curve. This is due to the increase in dipole and viscosity. As temperature increases, dipole moment is decreased from 0.98 to 0.64 [debye]. The activation energy which causes the relaxation and loss of dielectric is obtained about 15 [kcal/mole].

  • PDF

Clamping-diode Circuit for Marine Controlled-source Electromagnetic Transmitters

  • Song, Hongxi;Zhang, Yiming;Gao, Junxia;Zhang, Yu;Feng, Xinyue
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.395-406
    • /
    • 2018
  • Marine controlled-source electromagnetic transmitters (MCSETs) are important in marine electromagnetic exploration systems. They play a crucial role in the exploration of solid mineral resources, marine oil, and gas and in marine engineering evaluation. A DC-DC controlled-source circuit is typically used in traditional MCSETs, but using this circuit in MCSETs causes several problems, such as large voltage ringing of the high-frequency diode, heating of the insulated-gate bipolar transistor (IGBT) module, high temperature of the high-frequency transformer, loss of the duty cycle, and low transmission efficiency of the controlled-source circuit. This paper presents a clamping-diode circuit for MCSET (CDC-MCSET). Clamping diodes are added to the controlled-source circuit to reduce the loss of the duty ratio and the voltage peak of the high-frequency diode. The temperature of the high-frequency diode, IGBT module, and transformer is decreased, and the service life of these devices is prolonged. The power transmission efficiency of the controlled-source circuit is also improved. Saber simulation and a 20 KW MCSET are used to verify the correctness and effectiveness of the proposed CDC-MCSET.

무선통신을 이용한 배전용 변압기 모니터링 및 진단 장치 개발에 관한 연구 (The Study on the Monitoring and Diagnostic System for Distribution Transformer Using Wireless Communication)

  • 문종필;김재철;최준호;김언석;윤용한;민경래
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.214-216
    • /
    • 2001
  • In this paper, we developed the on-line Diagnostic & Monitoring system of distribution transformers using wireless communication. The Diagnostic system consists of the top oil temperature sensing, ambient temperature sensing. load current sensing, acoustic emission peak-value sensing, acoustic emission pulse counter and wireless communication part. The Monitoring system consists of the communication setting, online monitoring and database construction part. The Diagnostic system send the date acquired from the some sensors of the distribution transformers to the host PC. The Monitoring program of the host PC store the data to database. And the Monitoring system estimates the loss of life from the DB. Thus it could be managed the career and the functional lifetime of the transformer more efficiently than existing methodologies.

  • PDF

대형 디젤 엔진의 연료 분사 노즐 형상이 NOx 발생량 및 연료소비율에 미치는 영향 연구 (A Study on the Optimization of Fuel Injection Nozzle Geometry for Reducing NOx Emission in a Large Diesel Engine)

  • 김기두;하지수;윤욱현
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권7호
    • /
    • pp.1123-1130
    • /
    • 2004
  • Numerical simulations have been carried out to investigate the effect of nozzle hole geometry on the combustion characteristics of the large diesel engine. 6S90MC-C. Spray and combustion phenomena were examined numerically using FIRE code. Wane breakup and Zeldovich models were adopted to describe the atomization characteristics and NOx formation processes. Predictions on the cylinder peak pressure and NOx emission were first verified with the experimental data to confirm the reliability of numerical calculations. The comparison results showed good agreements within the range of 0.64% and 4.6% respectively. Finally, the effects of fuel spray angle and diameter on the engine performance were investigated numerically to find the optimum nozzle hole geometry considering fuel consumption, NOx emission and heat flux of the combustion chamber wall. It was concluded that the combustion gas recirculation in cylinder by changing fuel injection direction is an effective method to reduce NOx emission by about 10% with increasing fuel oil consumption, 1.4% in a large diesel engine.

A Study on the Assignment of the Vibration Classes to the Power Transformers in Operation (154[kV])

  • Kim, Young-Dal
    • 조명전기설비학회논문지
    • /
    • 제23권11호
    • /
    • pp.52-60
    • /
    • 2009
  • High reliability is essential for power transformers, and their fault causes are reportedly more related to mechanical causes than electrical ones. The transformer soundness judgment currently depends only on the electrical insulation characteristic and the chemical test of the insulation oil, so that there are few fundamental measures against the frequent mechanical damages and failures in transformers. The mechanical soundness judgment techniques are conducted through processes that include structural analysis and vibration resistance treatment during the manufacturing process of each manufacturer, but the vibration is not tested during the design, manufacturing, and operating processes since there are no detailed technical standards and procedures on the vibration problem, which are important in terms of maintenance. Therefore, in this study, vibration phenomena were measured from the 32 power transformers in operation in the substations under the Daejeon Power Transmission District Office of the Korean Electric Power Corporation (KEPCO). The vibration was measured at 24 sections ($6{\times}4$) on one side, and only the maximum values were selected from the measured vibration values. This was because the maximum vibration values more significantly affect the soundness of the transformer than the average vibration values. The vibration classes were given considering the maximum vibration based on ISO 10016-1 (2001).