• 제목/요약/키워드: peak load effects

검색결과 166건 처리시간 0.026초

Effect of Mixing Method on Mechanical Properties of Fiber Reinforced Concrete

  • Kim, Hyun Wook;Lee, Chang Joon
    • 한국건축시공학회지
    • /
    • 제15권3호
    • /
    • pp.351-357
    • /
    • 2015
  • Fiber reinforced concrete (FRC) has been successfully used to enhance the flexural toughness of concrete. As fibers are randomly oriented in FRC, they sometimes produce clumps that reduce the mechanical performance, and a properly chosen mixing protocol can be a way to minimize this problem. In this research, the effects of mixing method on the mechanical properties of FRC were investigated. The compressive strength, flexural strength, and flexural toughness were measured using three different mixing methods. It was shown from the results that the compressive strength and peak flexural load were not affected by changes in mixing method. However, in terms of flexural toughness, the changes in mixing method clearly affected the flexural toughness of FRC. The truck-mixed FRC outperformed two pan-mixed FRCs.

대형트럭 구동계의 저진동 설계 시스템의 개발연구 (A study on an analysis of torsional vibration of a driveline of heavy duty truck)

  • 황원걸;김기세
    • 한국정밀공학회지
    • /
    • 제13권3호
    • /
    • pp.132-140
    • /
    • 1996
  • This paper developes a torsional vibration model of heavy duty truck drive line for simulation of a driving rattle, which causes very annoying noise to driver at the full load driving condition. Test results show a peak in the fit plots at the frequency of the 2nd harmonics of propeller shaft revolution. A 10 d.o.f. lumped parameter nonlinear torsional vibration model is constructed and engine torque variation is calculated from P- .theta. diagram. Time responses are simulated and compared with the test results, which show fairly good agreement. The effects of paramenter change are investigated, and the optimum configuration is proposed.

  • PDF

냉방용 가스사용을 중심으로 추정한 냉방전력수요 평가 (A Study on the Evaluation of Cooling Demand using Cooling Gas Sales)

  • 김창수;이창호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.660-662
    • /
    • 2004
  • Cooling demand in Korea has increased constantly. Furthermore, an evaluation and savings of cooling demand has impacted on summer DSM and investment in Korea. Absorbed cooling system uses gas. It could achieve reductions in summer peak load and increase gas demand simultaneously. However its efficiency rate is lower than electric system. Gas cooling system uses separate meter. Therefore we could analyze monthly cooling demand and derive annual uses pattern. This paper analyzes demand pattern of gas cooling and its effects on electricity savings. Also this paper presents the course of policy in electricity sector on spreading of gas cooling measures.

  • PDF

M501J 가스터빈 연소기 단별 연료비율이 연소상태에 미치는 영향 고찰 (Effects of Combustor Stages on M501J Gas Turbine Combustion)

  • 유원주;정진도
    • 대한안전경영과학회지
    • /
    • 제21권2호
    • /
    • pp.1-8
    • /
    • 2019
  • Most of gas turbine combined cycle power plants are located in urban areas to provide peak load and district heating. However, NOx(nitrogen oxides) of exhaust gas emission from the power plants cause additional fine dust and thus it has negative impact on the urban environment. Although DLN(dry low NOx) and multi-stage combustors have been widely applied to solve this problem, they have another critical problem of damages to combustors and turbine components due to combustion dynamic pressure. In this study, the effect of different fuel ratio on NOx emission and pressure fluctuation was investigated regarding two variable conditions; combustor stages and power output on M501J gas turbine.

수종강심약물(數種强心藥物)과 부자(附子)"부타놀" 분획(分劃)이 심장근(心臟筋)의 기계적(機械的) 성질(性質)에 미치는 영향(影響) (Effects of Aconiti tuber butanol fraction and several cardiotonics on the mechanical properties of cat papillary muscle preparation)

  • 윤충
    • 대한약리학회지
    • /
    • 제12권1호
    • /
    • pp.45-55
    • /
    • 1976
  • The effect of positive inotropic agents on the contractile properties of myocardial muscle were studied in the cat papillary muscle preparation. For the purpose, the effects of ouabain $(1{\times}10^{-6}g/ml)$, norepinephrine (0.05r/m1) and Aconiti tuber butanol fraction (AF(5), $1{\times}10^{-4}$, $5{\times}10^{-4}$, $1{\times}10^{-3}$, $2{\times}10^{-3}g/ml$) on the contractile dynamics of the papillary muscle preparation isolated from right ventricle of cat were observed in terms of the characteristics of isometric twitch and the lengh-tension relation, the force-velocity relation and the load-extension relation of the series elastic component of contractile model of A.V. Hill. All the studied inotropic drugs similary increased the rate and the intensity of the developed isometric tension, while shortened the time from onset of contraction to peak tension and the total duration of contraction. In the afterloaded simultaneous isotonic and isometric contraction, they also similary increased the maximal velocity of shortening accompanied with the increasing the maximum developed force. In the load-extension relation all the drugs, however, had no appreciable influence on the properties of the series elastic component. Increasing the concentration, Aconiti tuber butanol fraction produced more pronounced effect on all the studied parameters of isometric and isotonic contraction of cat papillary muscle preparation. From the aspect of contractile dynamics, it seemed that the positive inotropic effect of ouabain, norepinephrine and Aconiti tuber butanol fraction are similary achieved through an influence on the behavior of the contractile component only.

  • PDF

Constitutive Modeling of Confined Concrete under Concentric Loading

  • Lee, Cha-Don;Park, Ki-Bong;Cha, Jun-Sil
    • KCI Concrete Journal
    • /
    • 제13권1호
    • /
    • pp.69-78
    • /
    • 2001
  • The inelastic behavior of a reinforced concrete columns is influenced by a number of factors : 1) level of axial load, 2) tie spacing, 3) volumetric ratio of lateral steel, 4) concrete strength, 5) distribution of longitudinal steel, 6) strength of lateral steel, 7) cover thickness, 8) configuration of lateral steel, 9) strain gradient, 10) strain rate, 11) the effectively confined concrete core area, and 12) amount of longitudinal steel. A new constitutive model of a confined concrete is suggested in order to investigate the nonlinear behavior of the reinforced concrete columns under concentric loading. The developed constitutive model for the confined concrete takes into account the effects of effectively confined area as well as the horizontal and longitudinal distributions of the confining pressures. None of the existing models incorporated these two main effects at the same time. A total of different six constitutive models for the behavior of the confined concrete under concentric compression were compared with the sixty-one test results reported by different researchers. The superiority of the developed model in its accuracy is demonstrated by evaluating the error function, which compares the weighted averages for the sum of squared relative differences in peak compressive strength and corresponding strain, stress at strain equal to 0.015, and total area under stress-strain curve up to strain equal to 0.015.

  • PDF

Mechanical behavior of sandstones under water-rock interactions

  • Zhou, Kunyou;Dou, Linming;Gong, Siyuan;Chai, Yanjiang;Li, Jiazhuo;Ma, Xiaotao;Song, Shikang
    • Geomechanics and Engineering
    • /
    • 제29권6호
    • /
    • pp.627-643
    • /
    • 2022
  • Water-rock interactions have a significant influence on the mechanical behavior of rocks. In this study, uniaxial compression and tension tests on different water-treated sandstone samples were conducted. Acoustic emission (AE) monitoring and micro-pore structure detection were carried out. Water-rock interactions and their effects on rock mechanical behavior were discussed. The results indicate that water content significantly weakens rock mechanical strength. The sensitivity of the mechanical parameters to water treatment, from high to low, are Poisson ratio (𝜇), uniaxial tensile strength (UTS), uniaxial compressive strength (UCS), elastic modulus (E), and peak strain (𝜀). After water treatment, AE activities and the shear crack percentage are reduced, the angles between macro fractures and loading direction are minimized, the dynamic phenomenon during loading is weakened, and the failure mode changes from a mixed tensile-shear type to a tensile one. Due to the softening, lubrication, and water wedge effects in water-rock interactions, water content increases pore size, promotes crack development, and weakens micro-pore structures. Further damage of rocks in fractured and caved zones due to the water-rock interactions leads to an extra load on the adjoining coal and rock masses, which will increase the risk of dynamic disasters.

Load carrying capacity of CFRP retrofitted broken concrete arch

  • Wang, Peng;Jiang, Meirong;Chen, Hailong;Jin, Fengnian;Zhou, Jiannan;Zheng, Qing;Fan, Hualin
    • Steel and Composite Structures
    • /
    • 제23권2호
    • /
    • pp.187-194
    • /
    • 2017
  • To reuse a broken plain concrete (PC) arch, a retrofitting method was proposed to ensure excellent structural performances, in which carbon fiber reinforced polymers (CFRPs) were applied to repair and strengthen the damaged PC arch through bonding and wrapping techniques. Experiments were carried out to reveal the deformation and the load carrying capacity of the retrofitted composite arch. Based on the experiments, repairing and strengthening effects of the CFRP retrofitted broken arch were revealed. Simplified analysing model was suggested to predict the peak load of the CFRP retrofitted broken arch. According to the research, it is confirmed that absolutely broken PC arch can be completely repaired and reinforced, and even behaves more excellent than the intact PC arch when bonded together and strengthened with CFRP sheets. Using CFRP bonding/wrapping technique a novel efficient composite PC arch structure can be constructed, the comparison between rebar reinforced concrete (RC) arch and composite PC arch reveals that CFRP reinforcements can replace the function of steel bars in concrete arch.

Investigating the load-displacement restorative force model for steel slag self-stressing concrete-filled circular steel tubular columns

  • Feng Yu;Bo Xu;Chi Yao;Alei Dong;Yuan Fang
    • Steel and Composite Structures
    • /
    • 제49권6호
    • /
    • pp.615-631
    • /
    • 2023
  • To investigate the seismic behavior of steel slag self-stressing concrete-filled circular steel tubular (SSSCFCST) columns, 14 specimens were designed, namely, 10 SSSCFCST columns and four ordinary steel slag (SS) concrete (SSC)-filled circular steel tubular (SSCFCST) columns. Comparative tests were conducted under low reversed cyclic loading considering various parameters, such as the axial compression ratio, diameter-thickness ratio, shear-span ratio, and expansion ratio of SSC. The failure process of the specimens was observed, and hysteretic and skeleton curves were obtained. Next, the influence of these parameters on the hysteretic behavior of the SSSCFCST columns was analyzed. The self stress of SS considerably increased the bearing capacity and ductility of the specimens. Results indicated that specimens with a shear-span ratio of 1.83 exhibited compression bending failure, whereas those with shear-span ratios of 0.91 or 1.37 exhibited drum-shaped cracking failure. However, shear-bond failure occurred in the nonloading direction. The stiffness of the falling section of the specimens decreased with increasing shear-span ratio. The hysteretic curves exhibited a weak pinch phenomenon, and their shapes evolved from a full shuttle shape to a bow shape during loading. The skeleton curves of the specimens were nearly complete, progressing through elastic, elastoplastic, and plastic stages. Based on the experimental study and considering the effects of the SSC expansion rate, shear-span ratio, diameter-thickness ratio, and axial compression ratio on the seismic behavior, a peak displacement coefficient of 0.91 was introduced through regression analysis. A simplified method for calculating load-displacement skeleton curves was proposed and loading and unloading rules for SSSCFCST columns were provided. The load-displacement restorative force model of the specimens was established. These findings can serve as a guide for further research and practical application of SSSCFCST columns.

네 가지 형태의 비우식성 치경부 병소의 3차원 유한요소법적 응력분석 (Effects of occlusal load on the stress distribution of four cavity configurations of noncarious cervical lesions: A three-dimensional finite element analysis study)

  • 전상제;박정길;김현철;우성관;김광훈;손권;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제31권5호
    • /
    • pp.359-370
    • /
    • 2006
  • 본 연구의 목적은 네 가지 형태의 비우식성 치경부 병소에 과다한 교합하중을 가했을 때 각 와동에 나타나는 응력 분포를 3차원적으로 조사하고자 하였다. 임상적으로 많이 관찰되는 다양한 형태의 병소 중 4가지 형태의 서로 다른 병소를 대표적으로 선택하여 발치된 상악 제2소구치에 3차원 유한요소 모형을 제작하였다. 형성된 모형에 협측교두와 설측교두에 500 N의 하중을 가한 후 치경부병소 첨부와 수직 절단면의 주 응력을 분석하여 다음과 같은 결과를 얻었다. 1 서로 다른 네 가지 형태의 와동에서 응력분포 양상은 비슷했지만 응력의 크기가 서로 달랐다. 2. 최대치 응력은 근심협측 우각부에서 나타났으며, 또한 병소의 첨부에 응력의 집중을 보였다. 3. 하중 A에서는 주된 응력이 압축 응력이었고 하중 B에서는 주된 응력이 인장 응력이었다. 4. 이러한 하중 하에서 수복치료를 하지 않으면 와동의 크기는 점차 커지고 치아구조에는 유해하게 작용하리라 생각된다.