• Title/Summary/Keyword: peak frequency

Search Result 2,163, Processing Time 0.034 seconds

A Study on Characteristic of Ceramic Tube for Ozone Generation (오존발생용 세라믹 방전관 특성에 관한 연구)

  • Cho, Kook-Hee;Kim, Young-Bae;Lee, Hong-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1724-1726
    • /
    • 2002
  • A novel ozonizer has been developed using a high-frequency surface discharge and a high purity alumina ceramic as its dielectric component. A thin ceramic layer, cylindrical in form, is adhered by a film-like induction electrode. An ac exciting voltage of frequency to 0.6 kHz from 1.0 kHz and $6{\sim}9kV$ peak-to-peak is applied between the electrodes to produce a stable high-frequency silent discharge for generation of ozone. A substantial reduction of the exciting voltage is also enabled by using a thin alumina ceramic layer. As a result, the ozonizer can easily produce ozone concentration($128g/m^2$ for oxygen) and power efficiency(360g/kWh for oxygen) without using a special enrichment means.

  • PDF

Input Current Ripple Reduction Algorithm for Interleaved DC-DC Converter (다상 DC-DC 컨버터의 입력 전류 리플 저감 제어 알고리즘)

  • Joo, Dong-Myoung;Kim, Dong-Hee;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.220-226
    • /
    • 2014
  • Input current ripple and harmonic components of the power device are main causes of electromagnetic interference (EMI). Although the discontinuous conduction mode (DCM) operation can reduce harmonic components of the power device by reducing reverse recovery current of diode and turn-off voltage spikes of the switch, input current ripple increases due to high peak to peak inductor current. Therefore, in this paper, frequency control algorithm is proposed to reduce the input current ripple of DCM operated interleaved boost converter. In the proposed algorithm, duty ratio is fixed either 0.33 or 0.67 to minimize the input current ripple and the switching frequency is controlled according to operating conditions. 600 W 3-phase interleaved boost converter prototype system is built to verify proposed algorithm.

An Improved Design Method of FIR Quadrature Mirror-Image Filter Banks (개선된 FIR QMF 뱅크의 설계 방법)

  • 조병모;김영수
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.2C
    • /
    • pp.213-221
    • /
    • 2004
  • A new method for design of two-channel finite-impulse response(FIR) quadrature mirror-image filter(QMF) banks with low reconstruction delay using weighting function is proposed. The weighting function used in this paper is calculated from the previous updated filter coefficients vector which is adjusted from iteration to iteration in the design of QMF banks. In this paper, passband and stopband edge frequency are used in design of QMF banks with low delay characteristic in time domain instead of specific frequency interval where the artifacts occur in conventional design method. The investigation of specific frequency interval where artifacts occur can not be required by using passband and stopband edge frequency. Some comparisons of performance are made with other existing design method to demonstrate the proposed method for QMF bank design. and it was observed that the proposed method using the weighted function and passband and stopband edge frequency improves the peak reconstruction error by 0.001 [dB], the peak-to-peak passband ripple by 0.003[dB], SNR with a white noise by 7[dB] and SNR with a step input by 32[dB], but with a reduction of the computational efficiency because of updating the weighting function over the conventional method in Ref [11].

A search-based high resolution frequency estimation providing improved convergence characteristics in power system (전력계통에서 수렴성 향상을 위한 탐색기반 고분해능 주파수 추정기법)

  • An, Gi-Sung;Seo, Young-Duk;Chang, Tae-Gyu;Kang, Sang-Hee
    • Journal of IKEEE
    • /
    • v.22 no.4
    • /
    • pp.999-1005
    • /
    • 2018
  • This paper proposed a search-based high resolution frequency estimation method in power systme. The proposed frequency estimation method adopts a slope-based adaptive search as a base of adaptive estimation structure. The architectural and operational parameters in this adaptive algorithm are changed using the information from context layer analysis of the signals including a localized full-search of spectral peak. The convergence rate of the proposed algorithm becomes much faster than those of other conventional slope-based adaptive algorithms by effectively reducing search range with the application of the localized full-search of spectrum peak. The improvements in accuracy and convergence rate of the proposed algorithm are confirmed through the performance comparison with other representative frequency estimation methods, such as, DFT(discrete Fourier transform) method, ECKF(extended complex Kalman filter), and MV(minimum variable) method.

Q-factor Estimation of Seismic Trace Including Random Noise using Peak Frequency-Shift Method (무작위 잡음이 포함된 탄성파 트레이스로부터 Peak Frequency-Shift 방법을 이용한 Q-factor 추정)

  • Kwon, Junseok;Chung, Wookeen;Ha, Jiho;Shin, Sungryul
    • Geophysics and Geophysical Exploration
    • /
    • v.21 no.1
    • /
    • pp.54-60
    • /
    • 2018
  • The data acquired from seismic exploration can be used to detect the existence of oil and gas resources through appropriate processing and interpretation. The seismic attributes indicating the existence of resources are extracted from amplitude information, where the Q-factor representing intrinsic attenuation plays an useful role of hydrocarbon indicator. So, the accuracy of Q-factor estimation is very important to investigate the existence of resources. In this study, we calculated the Q-factor and analyzed the error rate through a numerical example. To mimic real data, random noise was added to the synthetic data. With the noise-added data, the Q-factor was estimated and the error rate was analyzed by using the spectral ratio method (SRM) and peak frequency shift method (PFSM). Both methods provided a relatively accurate Q-factor when the signal-to-noise ratio was 90 dB. However, the peak frequency shift method (PFSM) produced better results than the spectral ratio method (SRM) as the level of random noise increased.

A Study on the Correlation Between Sasang Constitution and Sound Characteristics Used Harmonics and Formant Bandwidth (Harmonics(배음)와 Formant Bandwidth(포먼트 폭)를 이용한 음성특성(音聲特性)과 사상체질간(四象體質間)의 상관성(相關性) 연구(硏究))

  • Park, Sung-Jin;Kim, Dal-Rae
    • Journal of Sasang Constitutional Medicine
    • /
    • v.16 no.1
    • /
    • pp.61-73
    • /
    • 2004
  • This study was prepared to investigate the correlation between Sasang constitutional groups and voice characteristics using voice analysis system(in this study, CSL). I focused on the voice characteristics in terms of harmonics, Formant frequency and Formant Bandwidth. The subjects were 71 males. I classified them into three groups, that is Soeumin group, Soyangin group and Taeumin group. The classification method of Constitution used two ways, QSCCII(Questionnarie for the Sasang Constitution Classification II) and Interview with a specialist in Sasang Constitution. So 71 people were categorized into 31 Soeumin(people), 18 Soyangin(people) and 22 Taeumin(people). Pitch is approximately similar to the fundamental frequency(F0) in voices. Shimmer in dB gives an evaluation of the period-to-period variability of the peak-to-peak amplitude within the analyzed voice sample. FFT(Fast Fourier Transform) method in CSL can display sampled voices into harmonics. H1 is the first peak and h2 is the second peak in the harmonics. The amplitude difference of h1 and h2(h1-h2) can be explained as the speaker's phonation type, And Formant frequency and bandwidth can be explained as the speaker's vocal tract. So I checked the harmonics and Formant frequency and Bandwidth as the voice parameters. First I have captured /e/ voices from all subjects using microphone. And then I analyzed /e/ voices with CSL. Power Spectrum and Formant History is the menu in the CSL which can display harmonics and Formant frequency and bandwidth. The results about the correlation between Sasang Constitutional Groups and voice parameters are as follows; 1. There is no significant amplitude difference of harmonics(h1-h2) among three groups. 2. There is the significant difference between Soeumin Group and Soyangin Group in Formant Frequency 1 and Formant Bandwidth 1(p<0.05). Any other parameters have no significance. I assume that Soyangin Group has clearer and brighter voice than Soeumin Group according to the Formant Bandwidth difference. And I think its result has coincidence with the context of "Dongyi Suse Bowon" and "Sasangimhejinam".

  • PDF

Evaluation of Wave Characteristics and JONSWAP Spectrum Model in the Northeastern Jeju Island on Fall and Winter (제주도 북동부 연안에서 추동계 파랑특성과 JONSWAP 스펙트럼의 적용성 평가)

  • Kang, Dong-Hyub;Lee, Byung-Gul
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.17 no.2
    • /
    • pp.63-69
    • /
    • 2014
  • Analysis frequency spectrum through observed wave data in northeastern shore, jeju island, during winter and fall, and review wave characteristics. In order to compute maximum wave height, we calculate the ratio of significant wave height to maximum wave height using the linear regression equation. In addition, for calculating JONSWAP spectrum, we assumed ${\gamma}$ value using significant wave height and peak frequency in the observation area. Consequently, the highest frequency is below 1 m in the case of significant wave height and during the first observation, the mean of height was estimated at 0.523 m and during the scend observation, it was 0.423 m. Furthermore, in peak frequency, the highest frequency was 0.12 Hz~0.15 Hz (period is nearly 6.67s~8.33s), the results of ${\gamma}$ from using significant wave height and peak frequency is 2.72 and the significant wave height calculated by straight linear regression equation was $1.635H_s$.

Analysis of the Mandibular Movements in Patients with Internal Derangement of the Temporomandibular Joint According to Diagnostic Subgroups (측두하악관절내장 환자의 진단분류에 따른 하악운동 특성의 분석)

  • 김병연;기우천;최재갑
    • Journal of Oral Medicine and Pain
    • /
    • v.23 no.1
    • /
    • pp.21-36
    • /
    • 1998
  • The purpose of this study was analyse the mandibular movements in patients with internal derangement of the temporomandibular joint according to diagnostic subgroups. The author classified patients with internal derangement of the temporomandibular joint into 4 diagnostic subgroups by means of the magnet resonance imagings, and evaluated the clinical signs and the mandibular movements with Mandibular Kinesiograph(MKG) in each subgroups. The mandibular movements, measured in this study, were the types of movement in frontal and sagittal plane, velocities in opening and closing movement, and the opening and closing movement, and the opening and closing velocity pattern. The data were compared between the 5 groups including the normal group. The results were as follows : 1. Pain was more frequently observed in the anterior disc displacement without reduction group than in the anterior disc displacement with reduction group. Sound of joint was more frequently observed in the anterior disc displacement with reduction group, and limitation of mandibular opening movement was more frequently observed in the anterior disc displacement without reduction group. Duration of the anterior disc displacement without reduction group was significantly short compared to that of the anterior disc displacement with reduction group, and duration of the unilateral anterior disc displacement without reduction group was shortest in the experimental group. The frequency of Angle's classifications had not significant correlations between the experimental groups. 2. Active and passive range of the opening movement, maximum protrusive movement, maximum lateral movement toward left side were significantly decreased in the experimental groups compared to the control group, but there was no significant difference in the range of the maximum lateral movement toward right side between the control and experiment groups. In unilateral anterior disc displacement without reduction group, the range of maximum lateral movement toward unaffected side was no significant difference in the range of the maximum lateral movement between toward affected side and toward unaffected side. 3. Maximum opening velocity, maximum closing velocity, average opening velocity, average closing velocity and maximum velocity of terminal tooth contact were significantly decreased in the experimental groups compared to control group. There was no significant difference in maximum opening velocity and maximum velocity of Terminal tooth contact between the subgroups of the experimental group each other, but there was significant difference in maximum closing velocity, average opening velocity and average closing velocity between the subgroups each other. 4. In the frontal plane of the MKG, the frequency of complex deviation type(F-2)pattern was significantly increased in the anterior disc displacement with out reduction group compared to the anterior disc displacement with reduction group and the control group. In the sagittal plane, the frequency of coincident type(S-1)was decreased in the same group. 5. In the maximum opening velocity pattern, the frequency of no-peak type (OV-3)in the unilateral anterior disc displacement with reduction group was significantly increased compared to the control group. The frequency of 1-peak type (OV-1) and 2-peak type (OV-2) was decreased in the anterior disc displacement with out reduction group, but the frequency of no-peak type (OV-3)was increased in the same group. In the maximum closing velocity pattern, the frequency of no-peak type (CV-3) was significantly increased in the anterior disc displacement without reduction group. Compared to the anterior disc displacement with reduction group and the control group. The frequency of 1-peak type (CV-1) and 2-peak type (CV-2) in the anterior disc displacement with reduction group was decreased than that in the control group.

  • PDF

Detection of Ultrasonic Characteristics of Oil Corona by Wide-Band AE Sensor (광대역 AE 센서에 의한 유중코로나의 초음파 특성)

  • Kim, In-Sik;Lee, Sang-U;Lee, Dong-In;Lee, Gwang-Sik;Kim, Lee-Guk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.44-51
    • /
    • 2000
  • In this paper, using a wide-band AE sensor with the frequency range from 100[kHz] to 1.5[kHz], the frequency spectra of AE signals generated from the corona discharges of the needle-plane gap and from the partial discharges of an epoxy void were analyzed to determine the proper ultrasonic sensor with optimum frequency range according to the patterns of corona discharges. We also examined the propagation characteristics of AE signals in oil and the relationship between the magnitude of corona discharge and the magnitude of AE signals in peak-to-peak value under the application of 60[Hz] ac high-voltage. From these results, the main frequency spectra of AE signals emitted from the corona discharges of the needle-plane gap were about 130[kHz] by the fast fourier transform, but the main frequency spectra appeared to be 230[kHz] in the partial discharges of an epoxy void. The magnitude of AE signals was proportional to the magnitude of corona discharge and discharge current pulse with increasing the applied voltages.

  • PDF

Optimal Hysteresis Control for CCM Driving of a Single-Stage PFC Flyback Converter for LED Lightings (LED 구동용 단일단 PFC CCM 플라이백 컨버터의 히스테리시스 최적 제어)

  • Kim, Choon-Tack
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.586-592
    • /
    • 2016
  • The current control of Continuous Conduction Mode(CCM) can be implemented by several methods: peak current control; average current control; and hysteresis control. Among these methods, the hysteresis current control is popularly applied in various converter applications because of its simplicity of implementation, fast current control response and inherent peak current limiting capability. However, a current controller with conventional hysteresis band which multiplies the current reference has the disadvantage that the modulation frequency varies in one cycle of the input voltage and, as a result, generates high switching frequency in the low input voltage section. Also it is complicated to design the input filter due to varying switching frequency. This paper proposed an optimum hysteresis-band current control method where the band is generated by using both multiplication method and sum method to maintain the modulation frequency to be nearly constant. This approach can solve the high switching frequency in the low input voltage section, and achieve easy design of input filter. The performance of the proposed converter is verified with the simulation and the experimental works.