• Title/Summary/Keyword: peak effect

Search Result 3,459, Processing Time 0.029 seconds

Effect of the difference in spectral outputs of the single and dual-peak LEDs on the microhardness and the color stability of resin composites (Single-peak LED와 dual-peak LED의 출력 파장 차이가 복합 레진 미세 경도와 색 안정성에 미치는 영향)

  • Park, Hye-Jung;Son, Sung-Ae;Hur, Bock;Kim, Hyeon-Cheol;Kwon, Yong-Hoon;Park, Jeong-Kil
    • Restorative Dentistry and Endodontics
    • /
    • v.36 no.2
    • /
    • pp.108-113
    • /
    • 2011
  • Objectives: To determine the effect of the spectral output of single and dual-peak light emitting diode (LED) curing lights on the microhardness and color stability of commercial resin composites formulated with camphorquinone and alternative photoinitiators in combination. Materials and Methods: Three light-polymerized resin composites (Z100 (3M ESPE), Tetric Ceram (Ivoclar Vivadent) and Aelite LS Posterior (Bisco)) with different photoinitiator systems were used. The resin composites were packed into a Teflon mold (8 mm diameter and 2 mm thickness) on a cover glass. After packing the composites, they were light cured with single-peak and dual-peak LEDs. The Knoop microhardness (KHN) and color difference (${\Delta}E$) for 30 days were measured. The data was analyzed statistically using a student's t-test (p < 0.05). Results: All resin composites showed improved microhardness when a third-generation dual-peak LED light was used. The color stability was also higher for all resin composites with dual-peak LEDs. However, there was a significant difference only for Aelite LS Posterior. Conclusions: The dual-peak LEDs have a beneficial effect on the microhardness and color stability of resin composites formulated with a combination of camphorquinone and alternative photoinitiators.

Texture Profile Analysis of Acorn Flour Gels (도토리묵의 물리적 특성)

  • Kim, Young-A;Rhee, Hei-Soo
    • Korean Journal of Food Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.345-349
    • /
    • 1985
  • The textural properties of acorn flour gels were investigated with the variations in the concentraction, storage time and storage temperature by the use of Instron Universal Testing Machine. The experimental design was $3^3$ factorial experiment. TPA curves of acorn flour gels showed two sharp peaks in the first bite and no negative peak. The hardness and brittleness of acorn flour gels were very significantly affected by concentration, storage time and storage temperature. For the height difference between first peak and second peals, the main effects for concentration and storage temperature were very significant and the main effect for storage time was not negligible. For bend, the effect of concentration was more significant than the effect of storage temperature, and storage time effect was negligible. Springiness was affected only by the concentration.

  • PDF

An Experimental Study on Water-Hammer Effect for Spacecraft Propulsion System (인공위성 추진계통 관로내의 수격효과에 관한 실험적 연구)

  • Kwon, Ki-Chul;Lee, Eun-Sang;Park, Sang-Min;Kang, Shin-Jae;Rho, Byung-Joon
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.288-293
    • /
    • 2001
  • This paper presents the water-hammer effect due to the rapid opening and closing of isolation valve and thruster valve in the spacecraft propulsion system. The single propellant feed system was modeled to investigate the maximum peak pressure due to the water-hammer effect. The test parameters are tank supply pressure, shape and throat length of orifice and line length. Kerosene was used as the inert simulant propellant liquid instead of hydrazine. As downstream line length after isolation valve increased from 1.5 to 2.5m, the maximum line-filling water-hammer peak pressure decreased, but the average time interval between peak pressures increased. The maximum line-filling water-hammer peak pressure with orifice was lower than without orifice, and the maximum line-filling water-hammer peak pressure with orifice at the back of isolation valve was lower than with orifice in front of isolation valve. Without orifice, the maximum water-hammer peak pressure due to the rapid opening and closing of the thruster valve was about 126% of tank supply pressure. With orifice, it decreased. As orifice throat length increased, it decreased. The maximum water-hammer peak pressure due to the rapid closing of the thruster valve with converging-diverging orifice was lower than normal orifice. It was found that the orifice as a means of pressure drop was very effective to reduce the water hammer peak pressure at the thruster valve. The results of this study can be used for the design of spacecraft liquid propulsion feed system.

  • PDF

The Effect of Rear Foot Wedge Angle on Peak Plantar Pressures on the Forefoot During Walking (Rear Foot Wedge 각도가 보행시 전족저 최대압력에 미치는 영향)

  • Kwon, Oh-Yun;Jung, Do-Young;Park, Kyoung-Hee
    • Physical Therapy Korea
    • /
    • v.9 no.3
    • /
    • pp.11-21
    • /
    • 2002
  • The purpose of this study was to find the effect of rear foot wedge angle on peak plantar pressures on the forefoot during walking. Twenty normal healthy subjects (10 female, 10 male) were recruited. Peak plantar pressure was measured using pressure distribution platforms (MatScan system) in medial forefoot (under the first, second metatarsal head) and lateral forefoot (under the third, fourth, fifth metatarsal head). The subjects walked at the comfortable velocity under seven conditions; bare footed, $5^{\circ}$, $10^{\circ}$ and $15^{\circ}$ wedges under the medial and lateral sides of the hindfoot. The three averaged peak plantar pressures were collected at each condition at stance and toe off phases. The results showed that a significant increase in lateral forefoot plantar peak pressure investigated in the medial wedge and a significant decrease in lateral forefoot plantar peak pressure investigated in lateral wedge at stance phase (p<.05). These results suggest that rear foot wedge may be useful to modify the peak plantar pressure on the forefoot.

  • PDF

Analysis of Meridians Potential as Ground Condition for Objectification of Acupuncture Effect (침술 효과의 객관화를 위한 접지조건에 따른 경락전위분석)

  • Lee, Yong-Heum;Lee, Qyoun-Jung;Kim, Eun-Geun;Kim, Han-Sung;Shin, Tae-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.56 no.2
    • /
    • pp.436-441
    • /
    • 2007
  • Background: As patients are positioned at insulated bed and practitioner are positioned at insulated floor or shoes, it could be a cause of lessening effect in acupuncture practice. We investigated how Ground connection could influence on the electrical meridian potential between practitioner and patient during acupuncture practice. Method: We treated 30 normal healthy subjects with acupuncture and measured changes in the electrical potential between the stomach meridian points ST-39 and ST-37 in response to light touch after insertion of a needle at ST-36. At first, we stimulated needle and measured electrical potentials for non ground, patient ground only, practitioner ground only, all ground, respectively. Result: All ground subject elicited positive mean potential $44.6{\pm}19.2{\mu}V$ and showed $181.4{\pm}59.7{\mu}V$ peak to peak potential. practitioner ground only showed negative mean potential $-51.5{\pm}9.3{\mu}V\;and\;367.4{\pm}27.8{\mu}V$ of peak to peak potential. Patient ground only revealed no mean potential as $2.9{\pm}1.3{\mu}V,\;16.4{\pm}11.9{\mu}V$ of peak to peak potential. All ground showed no mean potential as $1.6{\pm}0.7{\mu}V,\;3.3{\pm}1.9{\mu}V$ of peak to peak potential. respectively.

The Effects of Lift-Off from Wall Thinning Signal in Pulsed Eddy Current Testing

  • Park, Duck-Gun;Angani, C.S.;Kishore, M.B.;Kim, C.G.;Lee, D.H.
    • Journal of Magnetics
    • /
    • v.17 no.4
    • /
    • pp.298-301
    • /
    • 2012
  • In order to know the effect of surface irregularity in the detection of local wall thinning of pipeline using pulsed eddy current (PEC), the lift-off effects on PEC signal have been investigated. Three kinds of parameters in the PEC signal, which is "peak amplitude", "time to peak amplitude" and "time to zero crossing" are analyzed to separate the lift-off effects in the PEC signal. The distance from sensor to the bottom of sample which is the total thickness of combined insulator and sample is kept constant. The magnitude of the differential peak amplitude is increased with increasing sample thickness, the time to peak amplitude is increased with increasing the sample thickness. To determine the effect of lift-off, a number of balanced transient responses combining wall thinning locations and lift-off distances were plotted.

Image Blurring Estimation and Calibration with a Joint Transform Correlator

  • Jeong, Man Ho
    • Journal of the Optical Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.472-476
    • /
    • 2014
  • The Joint Transform Correlator (JTC) has been the most suitable technique for real time optical pattern recognition and target tracking applications. This paper proposes a new application of the JTC system for an analysis of the blurring effect of the optical images caused by a defocused lens. We present the relation between the correlation peak, optical transfer function (OTF), and the amount of blurring caused by focusing error. Moreover, we show a possibility of calibrating the blurred image by simply measuring the correlation peak.

Effect of irrigation reservoir, antecedent soil moisture condition and Huff time distribution on peak discharge in a basin (농업용 저수지, 선행토양함수조건 및 Huff 시간 분포가 유역의 첨두홍수량에 미치는 영향 분석)

  • Kwon, Minsung;Ahn, Jae-Hyun;Jun, Kyung Soo;Kim, Tae-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.5
    • /
    • pp.417-424
    • /
    • 2018
  • This study analyzed the effect of irrigation reservoirs, antecedent soil moisture conditions (AMC) and Huff time distribution on peak discharge using Monte Carlo simulation. The peak discharge was estimated for four different cases in combination of irrigation reservoir capacity, AMC, and Huff time distribution. Applying 100% reservoir capacity or AMC-III, the peak discharges corresponding return periods of 50~300 years were overestimated by 25~30% compared to those of cases that considered the probability of occurrence for individual condition. Applying the 3rd quantile huff distribution, the peak discharges were overestimated by 5% over the peak discharge that considered the probability of occurrence. The overall results indicated that the effect on the peak flood of Huff distribution was less than AMC and reservoir storage.

Temperature Dependence of Photoluminescence in $SiO_2$ (실리콘산화막의 광루미니센스 온도의존성에 관한 연구)

  • 이재희
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.2
    • /
    • pp.247-251
    • /
    • 2001
  • Photoluminescence(PL) were observed from room temperature to 8K on $Si^+$-implanted silicon-oxide films. The PL intensities are increased from room temperature to 50~80K and decreased below 50K. The blue-shift occurs during the increasing of PL intensity. Also, temperature-dependent PL were measured at peak wavelengths. The first peak is the most sensitive to the measuring temperature. The experimental results are explained by quantum size effect of O rich defects or(and) Si rich defects rather than nanocrystal silicon.

  • PDF

Effect of Steady-State Oxidation on Tensile Failure of Zircaloy Cladding

  • Kim, Taeho;Choi, Kyoung Joon;Yoo, Seung Chang;Lee, Yunju;Kim, Ji Hyun
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.20 no.2
    • /
    • pp.161-170
    • /
    • 2022
  • The effect of oxidation time on the characteristics and mechanical properties of spent nuclear fuel cladding was investigated using Raman spectroscopy, tube rupture test, and tensile test. As oxidation time increased, the Raman peak associated with the tetragonal zirconium oxide phase diminished and merged with the Raman peak associated with the monoclinic zirconium oxide phase near 333 cm-1. Additionally, the other tetragonal zirconium oxide phase peak at 380 cm-1 decreased after 100 d of oxidation, whereas the zirconium monoclinic oxide peak became the dominant peak. The oxidation time had no effect on the tube rupture pressure of the oxidized zirconium alloy tube. However, the yield and tensile stresses of the oxidized nuclear fuel cladding tube decreased after 100 d of oxidation. The results of the scanning electron microscopy and transmission electron microscopy were represented with the in-situ Raman analysis result for the oxide characteristics generated on the cladding of spent nuclear fuel.