• 제목/요약/키워드: peak areas

검색결과 585건 처리시간 0.024초

기능적 하지길이 차이에 따른 동적 족저압의 분석 (The Analysis of Dynamic Foot Pressure on Difference of Functional Leg Length Inequality)

  • 공원태;김중휘;김태호
    • The Journal of Korean Physical Therapy
    • /
    • 제21권4호
    • /
    • pp.43-49
    • /
    • 2009
  • Purpose: This study examined the dynamic peak plantar pressure under the foot areas in those with a functional leg length inequality. Methods: The dynamic peak plantar pressure under the foot areas in an experimental group with a functional leg length inequality (n=20) and a control group (n=20) was assessed a using the Mat-Scan system (Tekscan, USA). The peak plantar pressure under the hallux, 1st, 2nd, 3-4th and 5th metatarsal head (MTH), mid foot, and heel was measured while the subject was walking on the Mat-Scan system. Results: The experimental group had significantly higher peak plantar pressure under all foot areas when the dynamic peak plantar pressure in the short leg and long leg sides was compared. The control group had a significantly higher peak plantar pressure under the 1st, 2nd, 3-4th, and 5th MTH when the dynamic peak plantar pressure in the short leg and long leg sides were compared. The experimental group showed a significantly larger difference in the dynamic peak plantar pressure under the hallux, 1st, 2nd, 3-4th and 5th MTH, mid foot and heel than the control group. Conclusion: A functional leg length inequality leads to an increase in the weight distribution and dynamic peak plantar pressure in the side of the short leg.

  • PDF

관통형과 단부형 필로티 천장부의 피크풍압계수 특성 분석 (Analysis of Peak Wind Pressure Coefficients of Penetration Type and End Type Pilotis)

  • 유장열;김근호;채명진;김영문;유기표
    • 한국공간구조학회논문집
    • /
    • 제18권2호
    • /
    • pp.59-67
    • /
    • 2018
  • Various pilotis are installed in the lower part of high rise buildings. Strong winds can generate sudden airflow around the pilotis, which can cause unexpected internal airflow changes and may cause damage to the exterior of the piloti ceiling. The present study investigates the characteristics of peak wind pressure coefficient for the design of piloti ceiling exteriors by conducting wind pressure tests on high rise buildings equipped with penetration-type and end-type pilotis in urban and suburban areas. The minimum peak wind pressure coefficient for penetration-type piloti ceilings ranges from -2.0 to -3.3. Minimum peak wind pressure coefficient in urban areas was 30% larger than in suburban areas. In end-type piloti ceilings, maximum peak wind-pressure coefficient ranges from 0.5 to 1.9, and minimum peak wind-pressure coefficient ranges from -1.3 to -3.6. With changes in building height, peak wind pressure coefficient decreases as the aspect ratio increases. Peak wind-pressure coefficient increases with taller pilotis. On the other hand, when piloti height decreases, the absolute value of the minimum peak wind pressure coefficient increases.

토지이용에 따른 강우-유출 특성 변화(농지조성 및 농어촌정비) (Variations of Rainfall-Runoff Characteristics with Landuse)

  • 임상준;서춘석;박승우
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.72-77
    • /
    • 2000
  • The purpose of this study were to monitor rainfall and runoff data from paddy blocks and forest areas at the Balan Experimental Watershed, and to investigate the variations of runoff characteristics with different land use. Field data showed that the total runoff from paddies and forest areas are not significantly different in volume. The peak discharge from forest areas was less than that from paddies for lighter storms, but became greater for heavier storms. The results demonstrate that paddies play an important role to reduce peak discharge from heavy storms as compared to forest.

  • PDF

첨단교통체계(ITS)에 의한 도시고속도록의 Ramp Metering 시스템 구축에 관한 연구 (The Ramp Metering System Construction of Urban Freeway by the Intelligent Transportation System (ITS) Technology)

  • 김태곤
    • 한국항만학회지
    • /
    • 제13권2호
    • /
    • pp.333-350
    • /
    • 1999
  • Today freeway is thought to be a very important transportation facility carrying tremendous traffic flow as the main corridor within the area of between the areas. However freeway is experiencing severe congestion and accidents by increased entrance ramp flow especially at peak time period. Ramp meters on the freeway entrance ramps that supply traffic to the freeway in a measured or appropriately regulated amount are needed for alleviating freeway congestion. Because ramp meters can be operated to discharge traffic at a measured or regulated rate thus maintaining more uniform speed on the mainline section maximizing the throughput to the freeway within the capacity of a downstream bottleneck and reducing the congestion related accidents. Thus the objectives in this study were to analyze the traffic characteristics on the freeway I-94 with ramp metering system before/after ITS technology in Detroit (Michigan) area compare shifts of the traffic characteristics on the freeway I-94 before/after ITS technology and finally suggest a better ramp metering strategy for the freeway system The following results were obtained: i)Flow occupancies and speeds on the mainline merge section of freeway were shown to be a big difference depending on the peak periods areas and directions based on the distribution of traffic flow characteristics on the freeway. ii)Reduced speed was shown to be more than 5 mph and ramp flow was also shown to be more than 240 vph at peak periods if there was the ramp metering system constructed on the freeway. iii)Ramp metering system was shown to be optimally operated on the freeway if ramp flow could be maximized within the range of over 900 vph and reduced occupancy could be also maximized by no more than 2 percent at peak periods. iv)The average flows on the freeway after the ITS technology were shown to be a decrease of over 20% depending on the peak periods areas and directions when compared with those flow on the freeway before the ITS technology. over 20% depending on the peak periods areas and directions when compared with those speeds on the freeway before the ITS technology. vi)The average metering rates on the freeway after the ITS technology were shown to be an increase of over 10% depending on the peak periods areas and directions when compared with those metering rates on the freeway before the ITS technology.

  • PDF

토지이용별에 따른 초기강우 유출량의 비점오염물 특성 분석 (Nonpoint Pollutants Sources Characteristics of Initial Surface Runoff on the Land Use Types)

  • 최윤영;정세영;최정우
    • 한국환경과학회지
    • /
    • 제20권3호
    • /
    • pp.417-426
    • /
    • 2011
  • This study was conducted to investigate runoff characteristics of non-point pollutants source at the urban and rural zones in sangju area. The monitoring was conducted with seven events for ten months and Event mean Concentration(EMC) and First Flush Effect(FFE) of SS and BOD were calculated on the result of the water quality parameters. During rainfall event, the peak concentrations of SS and BOD were observed after 3~4 hours of rainfall in rural areas. Whereas, the peak concentrations occurred within 1~2 hours after rainfall and then the highest concentration of NPS pollutants sharply decreased, showing strong first flush effect in urban areas. The cumulative load curves for NPS pollutants showed above the $45^{\circ}$ straight line, indicating that fist flush effect occurred in urban areas. The mean SS EMC values of rural areas ranged from 0.9~3.3mg/L, it was higher value when compare to urban areas. While the mean BOD values of urban areas were shown the highest values.

Evaluation of peak-fitting software for magnesium quantification through k0-instrumental neutron activation analysis

  • Dasari, Kishore B.;Cho, Hana;Jacimovic, Radojko;Park, Byung-Gun;Sun, Gwang-Min
    • Nuclear Engineering and Technology
    • /
    • 제54권2호
    • /
    • pp.462-468
    • /
    • 2022
  • The selection and effective utilization of peak-fitting software for conventional gamma-ray spectrum analysis is significant for accurate determination of the mass fraction of elements, particularly in complex peak regions. Majority of the peak-fitting programs can derive similar peak characteristics for singlet peaks, but very few programs can deconvolute multi-peaks in a complex region. The deconvolution of multi-peaks requires special peak-fitting functions, such as left and right-skew distributions. In the this study, 843.76 keV (27Mg) peak area from the complex region (840 keV-850 keV) determined and compared using four different peak-fitting programs, namely, GammaVision, Genie2000, HyperLab, and HyperGam. The 843.76 keV peak interfered with 841.63 keV (152mEu) and 846.81 keV (56Mn). The total Mg concentration was determined through k0-instrumental neutron activation analysis by applying the isotopic interference correction factor 27Al(n,p)27Mg through the simultaneous determination of Al concentration. HyperLab and HyperGam peak-fitting programs reported consistent peak areas, and resultant concentrations agreed with the certified values of matrix-certified reference materials.

밀폐공간에서 가스폭발에 의한 개구발생 후의 압력변화에 대한 해석 (Analysis of the Pressure Behavior with the Partial Rupture in Closed Vessel During Gaseous Explosion)

  • 윤재건;조한창;신현동
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.40-47
    • /
    • 1999
  • A numerical study on gaseous explosion was carried out to predict the transient pressure behavior with the partial rupture in confined vessels. Equations, assumptions and solutions for central ignition of premixed gases in closed spherical vessels are proposed with various equivalence ratios of gas fuel, as $CH_4$ and $C_3H_8$, vent areas and vent opening pressures. Given vent opening pressure in a vessel, the magnitude of second peak pressure results from the vent areas and burning velocity, varied by equivalence ratio of gas fuel. In a living room of an apartment, the higher second peak pressure than the vent pressure is not appeared due to its large window areas. As vent opening pressure is higher, the larger damage by gaseous explosion is expected and the larger vent area is necessary for relieving the damage. In the same concentration, the gaseous explosion by propane rather than methane shows the larger damage due to its higher adiabatic flame temperature and equivalence ratio.

  • PDF

인삼성분(人蔘成分)의 추출(抽出)에 관한 연구 -제1보 인삼(人蔘)의 지역별(地域別) 및 가공중(加工中) Saponin구성성분(構成成分)의 변화- (Studies on the Extraction of Korean Ginseng Component -Part 1. Differences of Saponins in Korean Ginseng by Cultivation Area and Processing-)

  • 유주현;김해중;변유량;남성희
    • 한국식품과학회지
    • /
    • 제9권4호
    • /
    • pp.313-316
    • /
    • 1977
  • The patterns of saponins of lateral gingengs cultivated different areas and various ginseng products were investigated by quantitative thin-layer chromatography. In the case of ginseng cultivated in the Kum San and Gang Hwa area, some parts of the panaxatriol series of the saponins (peak 6 and 7.8.9) were higher in concentration than in ginseng grown in other areas while the other ingredients were almost the same. In the process of heat treatment the quantity of peak 2 was generally decreased. However, in the case of red and white ginseng, one part of the panaxatriol saponins, peak 6 was increased. This tendency was also found in honeyed ginseng and ginseng tea which were not exposed to sunlight, but the increase was much less. The change in the red and white ginseng which were exposed to sunlight was very substantial. Therefore we can assume that the increase of peak 6 comes about due to the combination of heat treatment and exposure to sunlight, especially due to exposure to sunlight.

  • PDF

강우시 시화호 농촌 및 공단유역의 비점오염물질 유출특성 (Characteristics of Non-point Source Pollutants Runoff from Agricultural and Industrial Areas in Lake Sihwa Watershed)

  • 김세원;최광순;김동섭;이미경
    • 한국물환경학회지
    • /
    • 제25권5호
    • /
    • pp.768-777
    • /
    • 2009
  • The characteristics of stormwater runoff was examined on distinct types of agricultural and industrial area in Lake Sihwa watershed. During rainfall event, the peak concentrations of SS, $COD_{Mn}$, and TP were observed after 6~11 hours of rainfall in agricultural areas. Whereas, the peak concentrations occurred within the first one hour after rainfall and then the highest concentration of NPS pollutants sharply decreased, showing strong first flush effect in industrial areas. The strong first flush effect of suspended solid was apparent in agricultural areas, while those of organic matters and nutrients were clear in industrial areas. The cumulative load curves for NPS pollutants showed above the $45^{\circ}$ straight line, indicating that first flush effect occurred in industrial areas. The mean SS EMC values of agricultural areas ranged from 60~598 mg/L (Avg. 285 mg/L), it was higher value when compare to other areas. While the mean $COD_{Mn}$, TN, and TP EMCs values of industrial areas were shown the highest values as 67.7 mg/L, 12.1 mg/L and 2.1 mg/L respectively.

한반도 남서부의 상시미동 HVSR 연구 I: 정점주파수와 증폭효과의 특성 (The Microtremor HVSRs in the SW Korean Peninsula I: Characteristics of the HVSR Peak Frequency and Amplification)

  • 정희옥;김형준;조봉곤;박남률
    • 한국지구과학회지
    • /
    • 제31권6호
    • /
    • pp.541-554
    • /
    • 2010
  • 한반도 남서부 지역의 상시미동의 특성을 알아보기 위하여, 해안 지역(군산 136 지점)과 내륙 지역(전주 117 지점)에서 15분 씩 상시미동 자료를 획득하여 수평 대 수직 스펙트럼 비(HVSR, Horizontal to Vertical Spectral Ratio) 분석을 실시하였다. 상시미동의 에너지 스펙트럼은 내륙 지역에 비해 해안 지역에서 저주파 대역의 에너지가 크다. 이것은 서해의 파랑과 조류, 군산의 북쪽을 지나는 금강의 영향으로 보인다. 상시미동을 24시간 관측한 결과, 인간 활동과 연관된 상시미동 에너지는 변하나 상시미동 HVSR의 정점주파수($F_0$)는 변함이 없어, 하루 중 어느 시간에 관측해도 $F_0$의 안정된 값을 구할 수 있음을 시사한다. 관측점의 상시미동 피크를 싱글피크(single peak), 더블피크(double peak), 브로드피크(broad peak), 노피크(no peak)의 4 종류로 분류한 결과, 전체 관측점의 90 % 이상에서 정점주파수를 구할 수 있었다. 상시미동 $F_0$ 분포도는 기반암의 깊이가 얕은 구릉지에서 높은 주파수를, 하천 부근과 매립지에서 낮은 주파수를 보여 지형과 높은 상관관계를 보였다. 상시미동 $F_0$의 진폭($A_0$)은 전주지역에서는 하천의 하류에서 약 4 정도, 군산지역의 최근 매립지에서 대단히 높은 값(10 이상)을 나타낸다. 지진 발생시 매립지의 피해를 줄이기 위해서는 매립지의 부지반응에 대한 연구와 이에 따른 재해대책이 요구된다.