• 제목/요약/키워드: pattern transfer

검색결과 795건 처리시간 0.02초

Some Aspects of Experimental in-Tube Evaporation

  • Ha, Sam-Chul
    • Journal of Mechanical Science and Technology
    • /
    • 제14권5호
    • /
    • pp.537-546
    • /
    • 2000
  • The heat transfer characteristics of refrigerant-oil mixture for horizontal in-tube evaporator have been investigated experimentally. A smooth copper tube and a micro-fin tube with nominal 9.5 mm outer diameter and 1500 mm length were tested. For the pure refrigerant flow, the dependence of the axial heat transfer coefficient on quality was weak in the smooth tube, but in the micro-fin tube, the coefficients were 3 to 10 times greater as quality increases. Oil addition to pure refrigerant in the smooth tube altered the flow pattern dramatically at low mass fluxes, with a resultant enhancement of the wetting area by vigorous foaming. The heat transfer coefficients of the mixture for low and medium qualities were increased at low mass fluxes. In the micro-fin tube, however, the addition of oil deteriorates the local heat transfer performance for most of the quality range, except for low quality. The micro-fin tube consequently loses its advantage of high heat transfer performance for an oil fraction of 5%. Results are presented as plots of local heat transfer coefficient versus quality.

  • PDF

7개 질병군 포괄수가제 도입에 따른 일개 대학병원의 진료행태 변화 모의실험 (Simulation on the Change of Practice Pattern after the Introduction of 7 Diagnosis-related Groups Prospective Payment System in a University Hospital)

  • 신삼철;강길원;김상원
    • 보건행정학회지
    • /
    • 제23권2호
    • /
    • pp.103-111
    • /
    • 2013
  • Seven diagnosis-related groups (DRGs) prospective payment system is going to expand to all hospitals including university hospitals this year. However there are few studies on the change of practice pattern under prospective payment system in the university hospital setting. So This study was intended to predict the practice pattern change after the introduction of 7 DRGs prospective payment system in a university hospital setting. To predict the change of practice pattern, this study used simulation technique. Five hundred and nineteen patients classified as 5 DRGs in a university hospital were selected for simulation. The change of practice pattern were predicted based on clinicians' opinion. We also predicted payment change by service items. Major findings of this study are as follows. First, the total medical payment was reduced by 14.4%. The drug payment change (8.8%) took most of total payment reduction. The followings are the change of treatment material cost (3.2%), the change of laboratory tests cost (1.8%), the change of room charge (0.5%), and other payment change (0.1%), respectively. Second, most of the reduction in total medical payment resulted from the decreased amount of medical services themselves. The transfer of medical services to outpatient setting took up only 4.9% of the total payment reduction. The change of unit price or composition took up 5.5% of the total payment reduction. In this study we found that it is possible to reduce the inpatient services through practice pattern change in university hospital setting. However, it needs to be careful to adjust DRG payment after the reduction of provided services, because most of reduction was not due to service transfer but to service volume reduction. It is desirable to utilize the saving from practice pattern change as incentive to improve quality of care.

High Utility Itemset Mining by Using Binary PSO Algorithm with V-shaped Transfer Function and Nonlinear Acceleration Coefficient Strategy

  • Tao, Bodong;Shin, Ok Keun;Park, Hyu Chan
    • Journal of information and communication convergence engineering
    • /
    • 제20권2호
    • /
    • pp.103-112
    • /
    • 2022
  • The goal of pattern mining is to identify novel patterns in a database. High utility itemset mining (HUIM) is a research direction for pattern mining. This is different from frequent itemset mining (FIM), which additionally considers the quantity and profit of the commodity. Several algorithms have been used to mine high utility itemsets (HUIs). The original BPSO algorithm lacks local search capabilities in the subsequent stage, resulting in insufficient HUIs to be mined. Compared to the transfer function used in the original PSO algorithm, the V-shaped transfer function more sufficiently reflects the probability between the velocity and position change of the particles. Considering the influence of the acceleration factor on the particle motion mode and trajectory, a nonlinear acceleration strategy was used to enhance the search ability of the particles. Experiments show that the number of mined HUIs is 73% higher than that of the original BPSO algorithm, which indicates better performance of the proposed algorithm.

해금 몸체의 음향학적 특성에 관한 연구 (Acoustic Characteristics of the Haegeum Body)

  • 노정욱;박상하;성굉모
    • 한국음향학회지
    • /
    • 제26권7호
    • /
    • pp.317-322
    • /
    • 2007
  • 본 논문은 한국의 전통 찰현(擦絃)악기인 해금의 음향학적 특성을 연구하는 과정의 첫 단계로서, 우선 무향실에서 해금 몸체의 전달함수를 충격응답 방법을 이용하여 측정하였다. 측정 결과로 얻은 전달함수로부터 해금 몸체의 주요 공진 특성들을 살펴보고, 각 공진점이 해금 몸체의 어느 부분과 각각 관계가 있는지를 알아내기 위해 복판의 클라드니 패턴 실험, 해금 몸체 내 공동(空洞, air cavity)의 음향학적 모델링을 통한 공진 주파수 계산 등의 과정을 수행하였다. 그 결과, 해금 몸체의 주요 공진 특성과 몸체 각 부분들 간의 상관 관계를 밝혀낼 수 있었다.

환상이중원관에서 R-113의 비등열전달에 관한 연구 (A Study on the Boiling Heat Transfer of R-113 in a Concentric Annular Tube)

  • 김명환;김철환;오철;윤석훈;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권5호
    • /
    • pp.12-23
    • /
    • 1994
  • The two-phase flow is observed in power plants, chemical process plants, and refrigeration systems etc., and it is very important to solve the heat transfer mechanism of a boiler, an automic reactor, a condenser and various types of evaporators. Recently, the problem of two phase heat transfer is braught up in many regions with development of energy saving technique. In flow boiling system it is necessary to store data in each condition because the heat transfer characteristics of flow boiling region vary by the change of flow pattern and the magnetude of heat flux to tube length, and be subtly affected by the flow and heating condition. So basic study for knowing flow pattern in heat transfer region and the relation between heat transfer characteristic and flow condition is desired to accumulate data in wide variety of liquid and flow system in the study of heat transfer of two phase flow. In this study R-113 was selected as working fluid whose properties were programmed by least square method, and experiment was conducted in the region of mass flow $1.628{\times}10^6$~$4.884{\times}10^6$/kg/$m^2$hr with inlet subcooling 10~3$0^{\circ}C$, sustaining test section inlet pressure to 1.5kg$_f$/$cm^2$abs.

  • PDF

저속 영역에서 루버휜이 장착된 평판관형 알루미늄 열교환기의 공기측 전열 성능에 대한 실험적 연구 (Air-side Performance of Louver-Finned Flat Aluminum Heat Exchangers at a Low Velocity Region)

  • 조진표;오왕규;김내현;윤백
    • 대한기계학회논문집B
    • /
    • 제26권12호
    • /
    • pp.1681-1691
    • /
    • 2002
  • The heat transfer and pressure drop characteristics of heat exchangers with louver fins were experimentally investigated. The samples had small fin pitches (1.0 mm to 1.4 mm), and experiments were conducted up to a very low frontal air velocity (as low as 0.3 m/s). At a certain Reynolds number (critical Reynolds number), the flattening of the heat transfer coefficient curve was observed. The critical Reynolds number was insensitive to the louver angle, and decreased as the louver pitch to fin pitch ratio (L$_{p}$F$_{p}$) decreased. Existing correlations on the critical Reynolds number did not adequately predict the data. It is suggested that, for proper assessment of the heat transfer behavior, the louver pattern in addition to the flow characterization need to be considered. The heat transfer coefficient increased as the fin pitch decreased. At low Reynolds numbers, however, the trend was reversed. Possible explanation is provided considering the louver pattern between neighboring fins. Different from the heat transfer coefficient, the friction factor did not show the flattening characteristic. The reason may be attributed to the form drag by louvers, which offsets the decreased skin friction at a low Reynolds number. The friction factor increased as the fin pitch decreased and the louver angle increased. A new correlation predicted 92% of the heat transfer coefficient and 90% of the friction factor within $\pm$10%.10%.

RTM 공정의 실시간 제어에 관한 연구 (A Study on Real Time Control of Resin Transfer Molding)

  • 이도훈;박윤희;이우일;엄문광;변준형
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 추계학술발표대회 논문집
    • /
    • pp.79-82
    • /
    • 2003
  • In case of performing resin transfer molding (RTM), race track effects and non-uniform fiber volume fraction may cause undesirable resin flow pattern and thus result in dry spots, which affect the mechanical properties of the finished parts. In this study, a real time RTM control strategy to reduce these unfavorable effects is proposed. Through numerical simulations and experiments, the validity of the proposed scheme is demonstrated.

  • PDF

전사 인쇄에 의한 3D와 다층의 Pt 전극의 CO가스 흡착 (CO Adsorption on Three-Dimensional and Multilayered Platinum Electrode Prepared through Transfer Printing)

  • 정윤서;최유정;신정희;정영훈;박종후;윤대호;조정호
    • 센서학회지
    • /
    • 제29권4호
    • /
    • pp.232-236
    • /
    • 2020
  • Three-dimensional (3D) multilayered Pt electrodes were fabricated to develop a porous electrode using a pattern-transfer printing process. The Pt thin films were deposited using a transferred sputtering pattern having a 250 nm line width on the substrate, and the uniform line patterns were efficiently transferred using our proposed method. Temperature-programmed desorption (TPD) analyses were used to evaluate the porosity of the electrodes. It was possible to distinguish between two resolved maxima at 168 and 227 ℃, which could be described in terms of desorption reactions on the Pt (111) planes. The results of the TPD analysis of the 3D and multilayered Pt electrodes prepared through transfer printing were compared to those of an electrode fabricated through screen printing using a commercial Pt-carbon paste commonly used as porous electrodes. It was confirmed that the 3D multilayered electrodes exhibited a desorption concentration approximately 100 times higher than that of the Pt-carbon composite electrode, and the desorption concentration increased by approximately 0.02 mg/mol per layer. The 3D multilayered electrode effectively functions as a porous electrode and a catalyst.

이상 유동 비등 시 마이크로 채널에서의 열전달 특성과 유동양식 조사 (Heat transfer characteristic and flow pattern investigation in micro-channels during two-phase flow boiling)

  • 최용석;임태우
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제39권7호
    • /
    • pp.696-701
    • /
    • 2015
  • 본 연구에서는 깊이 0.2 mm, 폭 0.45 mm, 길이 60mm 그리고 채널의 개수는 15개인 마이크로 채널에서 이상 유동비등에 관한 실험을 수행하였다. 작동유체로는 FC-72가 사용되었으며, 실험은 질량유속과 열유속 각각 $200-400kg/m^2s$, $5-40kW/m^2$ 범위와 증기 건도 0.1-0.9 범위에서 수행되었다. 열전달 계수는 낮은 열유속에서는 급격하게 감소하였으며, 일정 열유속 이상에서는 거의 일정하게 유지되었다. 측정된 열전달 계수로부터 기존의 방법을 이용하여 기포류, 슬러그류, 천류 그리고 파형/환상류의 유동양식으로 분류하였다. 또한 분류한 유동양식의 결과를 파형/환상류 영역으로의 천이 기준과 비교하였다. 하지만 기존의 천이 기준으로는 본 연구의 실험결과를 만족스럽게 예측하지 못하였다.

수평관내 R-113 냉매의 비등열전달에 관한 연구 (A study on the boiling heat transfer of R-113 in a horizontal tube)

  • 최병철;김원녕;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.67-77
    • /
    • 1986
  • The information on the heat transfer characteristics, flow pattern and pressure drop, are very important for the desing of general heat exchanger, refrigerating system, air conditioning system and energy recovery system. In these systems, water or lubricating oil contained in working fluid affects greatly the flow and heat transfer condition and this phenomena must be considered in the practical design. An experiment has been performed for studying the flow and heat transfer characteristics of the forced convective horizontal flow of R-113 under the range of the liquid single phase state to the boiling flow state. Basic experimental results are obtained in the case that water or lubricating oil does not contaminate in the test fluid. Experimental results are as follows; (1) The local heat transfer coefficients in the nucleate boiling region and transition boiling region are almostly ten times as large as that of liquid single phase flow. (2) The measured heat transfer coefficient in the present experimental range is relatively agreed well with the predicted value from the various experimental results for the boiling flow.

  • PDF