수술 후 갑상선기능저하가 동반된 고도비만환자의 펜터민염산염/토피라메이트의 저용량 오프라벨 사용 (Low-Dose Off-Label Use of Phentermine/Topiramate in the Individual with Morbid Obesity and Postoperative Hypothyroidism)

  • 박정하
    • 비만대사연구학술지
    • /
    • 제1권1호
    • /
    • pp.43-45
    • /
    • 2022
  • Intensive lifestyle modifications and anti-obesity medications are essential for obesity treatment. Antiobesity medications should be selected according to the patient's comorbidities, symptoms, and preferences. This case report describes the treatment of a morbidly obese patient with a history of depression, who complained of tingling and numbness after total thyroidectomy for papillary thyroid cancer. Very low-dose controlled-release phentermine/topiramate was prescribed and intensive lifestyle modifications were encouraged. As a result, the patient effectively lost weight and reached a near-normal weight without adverse drug effects. This implies that even an off-label anti-obesity medication low dose may be better for some patients, and the most important factor in obesity treatment is patient-tailored treatment.

전신방사선조사(Total Body Irradiation) 시 Beam Spoiler와 환자 간의 거리에 관한 고찰 (Analysis of Surface Dose Refer to Distance between Beam Spoiler and Patient in Total Body Irradiation)

  • 최종환;김종식;최지민;신은혁;송기원;박영환
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.51-54
    • /
    • 2007
  • 목 적: 골수 또는 주변 줄기세포 이식을 목적으로 시행하는 전신방사선 조사시, 표면선량의 증가를 위하여 사용되어지는 산란판(beam spoiler)과 환자간의 거리에 따른 표면선량 변화를 측정하여 적정거리를 찾고자 한다. 대상 및 방법: 본 연구를 위해 6 MV X선을 사용하였으며, 조직등가고체팬텀($30{\times}30{\times}30cm^3$)과 평형평판형 전리함 및 전위계를 사용하였다. 선원에서 기준이 되는 팬텀 중심까지의 거리를 400 cm로 위치시키고 조사야 $40{\times}40cm^2$에서 얻은 측정치를 기준값으로 하였다. 또한 평형평판형 전리함을 고체팬텀의 선원 쪽 표면과 선원 반대쪽 표면에 각각 위치시켜 입사지점 선량과 출구지점 선량을 측정하였다. 산란판과 환자와의 적정 거리를 연구하기 위하여 조직 등가 고체 팬텀과 산란판 간의 거리를 $1{\sim}200cm$ 까지 변화시켜 가며 표면 선량을 측정하였다. 이때 조직등가 고체 팬텀은 고정시키고 산란판을 선원방향으로 일정한 간격으로 변화시켜 입사지점 선량과 출구지점 선량을 측정하였으며 이 값을 기측정된 팬텀 중심부 선량으로 나누어 백분율로 분석하였다. 각각의 경우에 대해 MU는 300씩 조사하였다. 결 과: 기준이 되는 체내 중심 선량을 처방 선량으로 간주하였고 산란판의 유무에 관계없이 체내 중심 선량과 출구 선량은 각각 10.7 cGy, 6.7 cGy로 측정되었다. 조직 등가 고체 팬텀과 산란판 사이의 간격이 $50{\sim}60cm$일 때 입사지점 선량 값은 $14.58{\sim}14.92cGy$로 측정되어 기준점 대비 $99.4{\sim}101%$ 범위를 보임에 따라 표면 선량값이 처방선량에 가장 근접한 값으로 측정되었다. 결 론: 본 실험 결과 전신방사선조사시, 조직등가 고체팬텀과 산란판 사이의 간격이 $50{\sim}60cm$일 때 표면선량을 처방선량에 가장 근접하게 조사할 수 있다는 것을 확인 할 수 있었다. 산란판과 환자와의 거리를 $50{\sim}60cm$에 위치시켜 표면선량의 over dose나 under dose의 발생 방지를 위한 주의가 반드시 필요하겠다.

  • PDF

투시 조영 검사 시 확대율에 따른 피폭선량에 관한 고찰 (Study on Radiation dose in according to Magnification's rate in fluoroscopy)

  • 강경미;홍선숙;성민숙;손운흥
    • 대한디지털의료영상학회논문지
    • /
    • 제15권2호
    • /
    • pp.39-44
    • /
    • 2013
  • Purpose : The purpose of this study is the magnification rates depending on the area of patient dose (DAP) and glass dosimeter see the change of the dose according to the dose characteristics of low-magnification aims to raise standards. Materials and Method : Direct DR equipment Sonialvision DAR-8000f, Shimadzu was used, the patient entrance dose measurements to the surface of the Rando Phantom of the neck and the abdomen was placed on the Xi unfors. glass dosimeter for measuring organ doses at the same time the Rando Phantom of the major organs in place by inserting a 9 ", 12", 15 ", 17" and 30 seconds for each magnification were measured according in fluoroscopy. DAP meter area of the patient dose was measured. Result : Esophagography at 17" 143% than 9"magnification the average area dose was increased. Organ dose of Esophagography at 17" was decreased 25.32% than 9" magnification. UGI at 17" was increased 129.73% DAP than 9" magnification. Organ dose of UGI at 17" was decreased 23.32% than 9" magnification. Where the major organs of magnification at 17" were decreased(lung -25.96%, stomach -33.09%, spleen -27.81%, liver -4.92%) than 9" magnification. Conclusion : Expected to get better quality image While using the proper magnification, and have recognition that difference Organ doses and DAP meter in fluoroscopy.

  • PDF

Practical Implementation of Patient-Specific Quality Assurance for Small and Multiple Brain Tumors in CyberKnife with Fixed Collimators

  • Lee, Eungman;Park, Kwangwoo;Kim, Jin Sung;Kim, Yong Bae;Lee, Ho
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.53-58
    • /
    • 2018
  • This paper evaluates patient-specific quality assurance (PSQA) in the treatment of small and multiple tumors by the CyberKnife system with fixed collimators, using an ion chamber and EBT3 films. We selected 49 patients with single or multiple brain tumors, and the treatment plans include one to four targets with total volumes ranging from 0.12 cc to 3.74 cc. All PSQA deliveries were performed with a stereotactic dose verification phantom. The A16 microchamber (Standard Imaging, WI, USA) and Gafchromic EBT3 film (Ashland ISP Advanced Materials, NJ, USA) were inserted into the phantom to measure the point dose of the target and the dose distribution, respectively. The film was scanned 1 hr after irradiation by a film digitizer scanner and analyzed using RIT software (Radiological Imaging Technology, CO, USA). The acceptance criteria was <5% for the point dose measurement and >90% gamma passing rate using 3%/3 mm and relative dose difference, respectively. The point dose errors between the calculated and measured dose by the ion chamber were in the range of -17.5% to 8.03%. The mean point dose differences for 5 mm, 7.5 mm, and 10 mm fixed cone size was -11.1%, -4.1%, and -1.5%, respectively. The mean gamma passing rates for all cases was 96.1%. Although the maximum dose distribution of multiple targets was not shown in the film, gamma distribution showed that dose verification for multiple tumors can be performed. The use of the microchamber and EBT3 film made it possible to verify the dosimetric and mechanical accuracy of small and multiple targets. In particular, the correction factors should be applied to small fixed collimators less than 10 mm.

F-18 FDG를 이용한 핵의학 검사에서 주변 선량의 안전성 평가 (The Safety Assessment of Surrounding Dose on Nuclear Medicine Test by Use The F-18 FDG)

  • 곽병준;지태정;민병인
    • 한국안전학회지
    • /
    • 제24권6호
    • /
    • pp.157-162
    • /
    • 2009
  • Radioactive medicines are used a lot owing to the increase of a PET-CT examination using glucose metabolism useful for the early diagnosis of diseases. Therefore, the spatial dose that is generated from patients and their surroundings causes the patients' guardians and health professional to be exposed to radiation. However, they get unnecessarily exposed to radiation because medical institutions lack in space for isolation and recognition of the examination. This research intended to examine the spatial dose rates by measuring the dose emitted from the patient for 48 hours to whom F-18 FDG was administered. The spatial dose rates that were measured 100cm away from the patient's body after F-18 FDG was injected were $65.88{\mu}$Sv/hr at 60-minute point, $45.13{\mu}$Sv/hr at 90-minute point, $9.88{\mu}$Sv/hr at 6-hour point, and $1.24{\mu}$Sv/hr at 12-hour point. When the dose that the guardian and health professional got was converted into the annual(240-day working) accumulative dose, it was examined that the guardian received 81.56 mSv/yr and health professional received 49.36mSv/yr. In addition, the result has revealed that the dose that the patient received from one time of PET-CT examination was 3.75mSv/yr, which is 1.5 times more when compared with the annual natural radiation exposure dose.

유리선량계를 이용한 투과선량 기반 환자선량 평가 시스템 개발을 위한 가능성 연구 (Feasibility Study for Development of Transit Dosimetry Based Patient Dose Verification System Using the Glass Dosimeter)

  • 정성훈;윤명근;김동욱;정원규;정미주;최상현
    • 한국의학물리학회지:의학물리
    • /
    • 제26권4호
    • /
    • pp.241-249
    • /
    • 2015
  • 방사선치료는 수술, 항암치료와 함께 암의 3대 치료방법으로써 많은 암환자들이 방사선치료를 받게 된다. 최대한 많은 방사선을 암에 집중시키고 최대한 적은 방사선을 주변 정상 조직에 가해주기 위해 치료 전 치료계획을 철저히 세우고 품질 관리를 시행하지만 방사선치료가 잘못 시행되어 의도치 않은 방사선이 환자에게 전달되는 의료사고가 발생하기도 한다. 이를 해결하기 위해 환자 내부의 선량을 검증하기 위한 방법을 투과선량 측정을 통한 환자 내부선량의 역추정 방법이 제시되고 있다. 본 연구에서 제시한 투과선량을 이용한 환자선량 계산 방법을 거리역자승법칙, 심부선량백분율, scatter factor를 이용한 방법으로써 실제 환자 선량 평가 가능성에 대해 균질한 물등가 팬텀을 이용한 연구이다. 투과선량에 대한 이온함과 유리선량계의 교정 결과 유리선량계의 신호값이 이온함으로 측정한 선량값에 비해 6 MV에서 0.824, 10 MV에서 0.736배인 것으로 나타났고 scatter factor는 평균적으로 1.4정도인 것으로 확인되었다. 심부선량백분율 데이터를 사용하기 위해 Mayneord F factor를 적용하였으며 위의 정보들을 이용하여 균질한 팬텀에서 알고리즘을 검증한 결과 최대 오차 약 1.65%로 계산이 정확하게 실시됨을 확인하였다.

비인두암 토모테라피 시 체중 감소에 따른 피부선량 변화 분석 (Analysis of Changes in Skin Dose During Weight Loss when Tomotherapyof Nasopharynx Cancer)

  • 장준영;김대현;최천웅;김보희;박철수
    • 한국자기학회지
    • /
    • 제26권3호
    • /
    • pp.99-104
    • /
    • 2016
  • 항암요법과 방사선치료를 병행하여 두경부암을 치료하는 환자의 경우 항암요법과 방사선치료를 거듭할수록 구토, 메스꺼움, 식욕부진 등의 이유로 환자의 체중 감소가 생기게 된다. 체중 감소는 목의 두께 변화로 나타날 수 있으며 이로 인해 치료하고자 하는 t 타겟과 주위 정상조직의 선량 전달에도 영향을 미치며 방사선이 전달되는 방향에 위치한 피부선량의 변화가 나타날 것으로 사료된다. 특히 비인두암 환자의 경우 비인두 구조가 다른 장기보다 복잡한 구조를 지니고 있고 치료방법인 토모테라피는 수 mm 차이로 급격한 선량 변화가 발생하므로 이러한 체중 감소의 변화에 주의 깊은 관찰이 필요하다. 현재 토모테라피의 경우 매 회 치료 전 정확한 자세 재현을 위한 영상 검증을 통해 이러한 움직임을 확인하고 그 값을 보정하여 치료를 수행한다. 그러나 환자의 체중 감소로 인하여 피부선량에 전달되는 선량 변화의 검증은 되지 않고 있다. 환자의 피부선량이 증가함으로써 나타나는 부작용은 환자의 삶의 질에 영향을 미칠 뿐 만 아니라 2차 암 발생률을 높일 수 있다. 이에 환자의 체중 감소로 인하여 나타나는 환자의 목 두께를 휴먼 팬톰에 볼루스를 올리고 두께를 조절해가며 변화시켜 필름을 이용하여 피부선량의 변화가 어떻게 나타나는지 분석해보고자 한다.

방사성요오드(I-131) 격리병실 치료 관리를 위한 환자의 체외방사선량률과 상주 보호자의 피폭선량평가 (Evaluation of Caregivers' Exposed Dose and Patients' External Dose Rate for Radioactive Iodine (I-131) Therapy Administration in Isolated Ward)

  • 강석진;이두현;소영;이정우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.347-353
    • /
    • 2022
  • In this study, the radiation dose rate was measured by time and distance and evaluated whether radiation dose rate was suitable for domestic and international discharge criteria. In addition, the radiation dose emitted from the patient was measured with a glass dosimeter to evaluate the exposure dose if the caregiver stays in the isolated ward by placing a humanoid phantom instead of the caregiver at a distance of 1 m from the patient, on the second day of treatment. After 23 hours of isolation, the radiation dose rates at a distance of 1 m were 20.54 ± 6.21 µSv/h at 2.96 GBq administration and 27.94 ± 12.33 µSv/h at 3.70 GBq administration. The radiation dose rates at a distance of 1 m were 25.90 ± 2.21 µSv/h when 2.96 GBq was administered and 34.22 ± 10.06 µSv/h when 3.70 GBq was administered after 18 hours of isolation. However, if the isolation period is short may cause unnecessary radiation exposure to the third person. The reading of the attached dosimeter from the morning of the second day of treatment until removal was 0.01 to 0.95 mSv, which is a surface dose determined by the International Commission on Radiation Units and Measurements. And the depth dose was 0.01 to 0.99 mSv. On the second day of treatment, even if the patient caregivers stayed in the isolation ward, the exposure dose of the patient family did not exceed the effective dose limit of 5 mSv recommended by the ICRP and NCRP.

PET-CT 검사 환자의 외부 방사선량률 변화 (Changes in External Radiation Dose Rate for PET-CT Test Patients)

  • 김수진;한은옥
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.103-107
    • /
    • 2012
  • PET-CT 검사 환자의 피폭선량 감소를 위한 기초자료 제공의 일환으로 PET-CT 검사 환자의 방사선량률의 변화를 분석하고자 하였다. PET-CT 검사 환자의 방사선량률을 측정한 결과 이론과 같이 방사성의약품이 투여된 환자로부터 거리가 멀수록, 시간이 지날수록 방사선량률은 감소되는 것을 볼 수 있었다. 특히 신체부위에 따라서는 방사성의약품 정맥 주사 즉시인 약 4.17분에서는 흉부, PET-CT 검사 전 배뇨 후인 약 77.47분 이후부터는 두부가 가장 높게 나타났다. 일반화되어 있는 정보와 같이 PET-CT 검사 환자로부터 받는 방사선 피폭량을 감소시키기 위해서는 보호자나 방사선작업종사자가 환자로부터 거리를 멀리하거나 방사능이 감소된 이후의 시간부터 접촉하는 것이 바람직하다. 불가피한 접촉이 필요하다면 가능한 거리는 200 cm이상을 확보하는 것이 바람직하다. 또한 초기에는 흉부, 방사성의약품 투여 후 약 77분 이후부터는 두부에 방사선량률이 높기 때문에 환자 신체적 특징을 고려한 접촉도 함께 이루어진다면 최적화 달성에 도움이 될 것이라고 보여 진다. 본 연구에서 도출된 PET-CT 검사 환자의 거리, 시간, 신체부위에 따른 방사선량률 변화를 알 수 있다는 점에서 연구에 의의가 있다고 본다. 향후 연구에서는 본 연구에서 도출된 결과를 바탕으로 환자 개인특성에 따른 방사선량률의 변화 차이를 분석하여 환자, 보호자, 종사자의 피폭선량 감소에 활용할 수 있도록 지속적인 연구가 수행되는 것이 필요하다고 본다.

Fetal dose from Head and Neck Tomotherapy Versus 3D Conformal Radiotherapy

  • Park, So Hyun;Choi, Won Hoon;Choi, Jinhyun
    • Journal of Radiation Protection and Research
    • /
    • 제44권4호
    • /
    • pp.156-160
    • /
    • 2019
  • Background: To compare the dose of radiation received by the fetus in a pregnant patient irradiated for head and neck cancer using helical tomotherapy and three-dimensional conformal radiation therapy (3DCRT). Materials and Methods: The patient was modeled with a humanoid phantom to mimic a gestation of 26 weeks. Radiotherapy with a total dose of 2 Gy was delivered with both tomotherapy (2.5 and 5.0 cm jaw size) and 3DCRT. The position of the fetus was predicted to be 45 cm from the field edge at the time of treatment. The delivered dose was measured according to the distance from the field edge and the fetus. Results and Discussion: The accumulated dose to the fetus was 1.6 cGy by 3DCRT and 2 and 2.3 cGy by the 2.5 and 5 cm jaw tomotherapy plans. For tomotherapy, the fetal dose with the 2.5 cm jaw was lower than that with the 5 cm jaw, although the radiation leakage was greater for 2.5 cm jaw plan due to the 1.5 fold longer beam-on time. At the uterine fundus, tomotherapy with a 5 cm jaw delivered the highest dose of 2.4 cGy. When the fetus moves up to 35 cm at the 29th week of gestation, the resultant fetal doses for 3DCRT and tomotherapy with 2.5 and 5 cm jaws were estimated as 2.1, 2.7, and 3.9 cGy, respectively. Conclusion: For tomotherapy, scattering radiation was more important due to the high monitor unit values. Therefore, selecting a smaller jaw size for tomotherapy may reduce the fetal dose. however, evaluation of risk should be individually performed for each patient.