• 제목/요약/키워드: path of water leakage

검색결과 20건 처리시간 0.026초

15년 경과한 PC아파트의 누수경로 조사결과 (Path of Water Leakage of PC Apartment House 15 Years Have Elapsed)

  • 이정훈;배기선;김상연;최성민;오상근
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.156-157
    • /
    • 2014
  • PC apartment house 15 years have elapsed have various deteriorations by water leakage in roof and wall. The prior investigation such as investigating of leakage repair history of PC apartment and the field investigation were carried out to solve the water leak problem in its structure. The path of water was analyzed on the parts of greatest water leak such as roof parapet, roof floor, side wall, corridor and balcony. As a result, the specific path of the water leakage was identified in various structure units.

  • PDF

수변구조물의 누수 경로 탐지를 위한 변형된 전기비저항 탐사 및 자료 해석 (Modified Electrical Resistivity Survey and its Interpretation for Leakage Path Detection of Water Facilities)

  • 이보미;오석훈
    • 지구물리와물리탐사
    • /
    • 제19권4호
    • /
    • pp.200-211
    • /
    • 2016
  • 횡단 전위 배열(cross potential array)과 동일열 전위배열(direct potential array) 자료를 뒷받침하여 다양한 수변 구조물의 누수 경로 예측을 가능하게 하는 배열을 제시하고 이를 D-Lux array 라고 명명하였다. 또한 D-Lux array 자료를 색으로 가시화한 하나의 행렬로 정리하여 D-Lux view라고 제시하고 D-Lux view에서 관찰되는 저 전위차 이상대의 위치로 누수 구역의 위치를 해석하였다. D-Lux view의 보다 직관적인 해석을 위해서 D-Lux array 자료와 동일열 전위 배열 자료를 함께 사용하여 각 지점들 사이의 전위차 자료를 각 지점의 전위값으로 역산하고 이를 이용하여 등전위 분포도를 작성하였다. 등전위 분포도는 그래프나 D-Lux view에서 알 수 없었던 누수의 유입구, 유출구 뿐만 아니라 경로까지 예측 가능하게 하였다. 수조 실험과 수치 해석으로 예비 탐사를 실시한 후 현장 탐사로 콘크리트 보와 필 댐에 대한 적용이 이루어졌다. 그 결과, 콘크리트 보와 필 댐에 대해 누수 경로 탐지가 가능함을 확인하였다.

Validation of a new magnetometric survey for mapping 3D subsurface leakage paths

  • Park, DongSoon;Jessop, Mike L.
    • Geosciences Journal
    • /
    • 제22권6호
    • /
    • pp.891-902
    • /
    • 2018
  • Techniques for more reliable detection of 3D subsurface flow paths are highly important for most water-related geotechnical projects. In this case study, a magnetometric resistivity method with a new approach and state-of-the-art technology ("Willowstick survey") was applied to the testbed dam (YD dam) site, and its applicability was validated by geotechnical investigation techniques including borehole drilling and sampling, Lugeon test, flow direction and velocity test, and seismic tomography. In addition to the magnetometric survey, a 3D electrical resistivity survey was performed independently and the results were compared and discussed. The electrical resistivity survey was effective in detecting groundwater levels, but it was limited in mapping leakage paths. On the other hand, the Willowstick magnetometric survey effectively detected geologic weaknesses (e.g., fault fracture) and potential leakage paths of the dam site foundation rocks. The results of this research are expected to be effective for water infrastructures where leakage is an important issue.

취약대가 존재하는 제방의 누수 탐지를 위한 전기비저항 탐사의 적용성 연구 (A Study on Application of Electrical Resistivity Survey to Detect the Leakage of Embankment with Weak Zone)

  • 박삼규;김재홍
    • 한국지반환경공학회 논문집
    • /
    • 제14권4호
    • /
    • pp.5-13
    • /
    • 2013
  • 댐 및 저수지 제방의 누수현상은 통관 주변에서 주로 일어나며 평상 시에는 제방에 큰 영향을 미치지 않지만, 호우나 장마철과 같이 저수지 수위가 상승하면 제방의 붕괴 위험을 가져온다. 따라서 이러한 수맥과 경로를 조사하는 것은 재해 예방과 제방 관리의 측면에서 매우 중요하다. 본 연구에서는 수치적인 방법과 실험적인 방법을 사용하여 통관이 취약대로 작용하는 댐 및 제방에서의 누수현상을 분석하였다. 누수탐지에는 전기비저항 탐사를 사용하여 그 유용성을 검토하였다. 수치해석의 결과에서는 취약대의 크기와 위치에 따라 전극 간격의 설정이 중요함을 보여주었고, 모형제방의 누수실험에서는 전극간격을 0.3m로 쌍극자 배열을 사용하는 것이 가장 좋은 결과를 얻을 수 있을 것으로 판단되었다. 누수현상의 분석을 통하여 댐 및 제방시설물의 누수탐지에 전기 비저항 탐사가 유용함을 확인하였다.

지온탐사에 의한 저수지 제방의 누수 조사 (Delineation of water seepage in a reservoir embankment from ground temperature measurements)

  • 박삼규
    • 자원환경지질
    • /
    • 제32권2호
    • /
    • pp.169-175
    • /
    • 1999
  • The water leakage of reservoir embankment usually occurs through water vein, which gives little influence on the embankment in a normal state. However, the embankment can be destroyed when the water level of reservoir increases with heavy rain in summer. Investigating the water vein and its path is therefore very important from the viewpoint of disater prevention and embankment protection. This paper presents survey results of one-meter-depth ground temperature and multi-point temperature logging in an embankment in Japan to delineate water veins and permeable formations. Four water veins have been predicted in the embankment by comparing measured one-meter-depth ground temperatures with the background ones which have no effect of water vein. The multi-point temperature logging was carried out in the borehole drilled at one of the predicted water veins. Depth and thickness of the permeable formation in the borehole can be determined from temperature restoration ratios with elapsed time. From these results we can find that the water leakage of reservoir embankment mainly occurs in sandy soil formation in the embankment.

  • PDF

Sequential optimization for pressure management in water distribution networks

  • Malvin S. Marlim;Doosun Kang
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2023년도 학술발표회
    • /
    • pp.169-169
    • /
    • 2023
  • Most distributed water is not used effectively due to water loss occurring in pipe networks. These water losses are caused by leakage, typically due to high water pressure to ensure adequate water supply. High water pressure can cause the pipe to burst or develop leaks over time, particularly in an aging network. In order to reduce the amount of leakage and ensure proper water distribution, it is important to apply pressure management. Pressure management aims to maintain a steady and uniform pressure level throughout the network, which can be achieved through various operational schemes. The schemes include: (1) installing a variable speed pump (VSP), (2) introducing district metered area (DMA), and (3) operating pressure-reducing valves (PRV). Applying these approaches requires consideration of various hydraulic, economic, and environmental aspects. Due to the different functions of these approaches and related components, an all-together optimization of these schemes is a complicated task. In order to reduce the optimization complexity, this study recommends a sequential optimization method. With three network operation schemes considered (i.e., VSP, DMA, and PRV), the method explores all the possible combinations of pressure management paths. Through sequential optimization, the best pressure management path can be determined using a multiple-criteria decision analysis (MCDA) to weigh in factors of cost savings, investment, pressure uniformity, and CO2 emissions. Additionally, the contribution of each scheme to pressure management was also described in the application results.

  • PDF

흙댐의 누수구역 판별을 위한 온도 모니터링 자료의 해석 (Analysis of temperature monitoring data for leakage detection of earth dam)

  • 오석훈;서백수
    • 산업기술연구
    • /
    • 제28권B호
    • /
    • pp.39-45
    • /
    • 2008
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old earth fill dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

댐 침투수 탐지를 위한 멀티 채널 온도 모니터링 연구 (A Study on multi-channel temperature monitoring for the detection of leakage or seepage in dam body)

  • 오석훈;김중열;박한규;김형수;김유성
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1211-1218
    • /
    • 2005
  • Temperature variation according to space and time on the inner parts of engineering constructions(e.g.: dam, slope) can be a basic information for diagnosing their safety problem. In general, as constructions become superannuated, structural deformation(e.g.: cracks, defects) could be occurred by various factors. Seepage or leakage of water through these cracks or defects in old dams will directly cause temperature anomaly. Groundwater level also can be easily observed by abrupt change of temperature on the level. This study shows that the position of seepage or leakage in dam body can be detected by multi-channel temperature monitoring using thermal line sensor. For this, diverse temperature monitoring experiments for a leakage physical model were performed in the laboratory. In field application of an old dam, temperature variations for water depth and for inner parts of boreholes located at downstream slope were measured. Temperature monitoring results for a long time at the bottom of downstream slope of the dam showed the possibility that temperature monitoring can provide the synthetic information about flowing path and quantity of seepage of leakage in dam body.

  • PDF

소듐 분위기에서 물누출에 의한 5Cr-1Mo Ferrite강 구멍의 막힘과 재개방 현상 (Plugging and Re-opening Phenomena of the 5Cr-1Mo Steel Leak Hole by Water Leakage in Sodium Atmosphere)

  • 정경채;김태준;최종현;박진호;황성태
    • 공업화학
    • /
    • 제9권5호
    • /
    • pp.674-679
    • /
    • 1998
  • 액체금속로 증기발생기 전열관 재질로 사용이 예상되는 ferrite steel 시편을 사용해서 소듐분위기에서 미량의 물 누출 실험을 수행하였다. 누출경로는 소듐-물 반응생성물 및 부식생성물에 의한 self-plugging 현상과 열적인 transient 및 전열관의 vibration에 의한 re-opening 메카니즘으로 설명이 가능하였다. 실험결과, 600 Psig의 injection 압력으로 5 g $H_2O$를 소듐분위기 속의 시편으로 누출시킨 경우, 누출초기와 약 70분 경과 후에 약간의 누출 흔적이 보였으나, self-plugging되었던 누출경로는 129분이 경과되자 완전 re-opening된 것으로 확인되었다. 누출시편의 re-opening shape은 2중으로 되어 있었으며, 소듐부위에서 시편 표면에 나타난 re-opening size 약 2 mm의 직경을 나타내었다.

  • PDF

흙댐의 누수구역 판별을 위한 물리탐사와 온도 모니터링 자료의 해석 (An Analysis of Geophysical and Temperature Monitoring Data for Leakage Detection of Earth Dam)

  • 오석훈;서백수;김중열
    • 한국지구과학회지
    • /
    • 제31권6호
    • /
    • pp.563-572
    • /
    • 2010
  • 흙댐에서의 누수 구역을 판별하기 위해 다채널 연속 온도 모니터링을 수행하고 이를 검증하기 위해 전기비저항 물리탐사를 함께 수행하였다. 일반적으로 댐이나 사면과 같은 인공구조물의 내부는 시간과 위치에 따라 상이한 온도 분포를 갖는 것으로 여겨진다. 이와 같은 분포는 구조물의 안전성을 판단하는 데 매우 중요한 기본 자료로 이용될 수 있으며, 특히 댐 구조물의 경우 과도 침투수나 누수에 의한 위험 대역을 파악할 수 있는 기술로 이용될 수 있다. 그러나 기존의 온도 측정 방식은 대형 구조물의 온도를 연속적으로 동시에 측정할 수 없는 단점을 가지고 있다. 본 연구에서는 이를 극복한 새로운 온도 모니터링 장비를 이용하여 댐의 상부 및 하부에 걸쳐, 여러 지점에서 동시에 온도 분포를 측정하였으며, 실내 시험을 통해 누수 대역이 온도 분포의 이상을 충분히 반영하고 있음을 관측하였다. 또한 대상 댐의 전 구역에 걸쳐 전기비저항 조사를 수행한 결과와 온도 모니터링 자료를 비교 분석하여 누수구역의 판별력을 높일 수 있는 방법을 제시하고자 하였다.