• Title/Summary/Keyword: patch-tests

Search Result 96, Processing Time 0.025 seconds

Study on Changes of Hair and Scalp Characteristics by Keratin Peptides (케라틴 펩타이드에 의한 모발 및 두피 특성 변화 연구)

  • Nam, Gaewon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.45 no.4
    • /
    • pp.353-361
    • /
    • 2019
  • Using Fervidobacterium islandicum AW-1, keratin peptides were produced and confirmed factors related to the scalp and hair. The cytotoxicity and proliferation tests as a function of the concentration of the keratin peptide did not show toxicity and effect on the cellular proliferation in the immortalized human hair dermal papilla cell line. Hair shampoos and hair essences containing keratin peptides were produced, and conducted human patch test. Result showed no skin irritation. The shampoo and the essence were apploed to 2 groups of 30 healthy adults for 4 weeks and showed statistically significant positive results for gloss, hair loss, scalp trouble, and hair roughness by visual assessment. The scalp water content was significantly increased after 2 and 4 weeks compared to before using the shampoo or the essence. Trans-epidermal water loss (TEWL) and the sebum secretion amount in the scalp were significantly decreased after 4 weeks compared to before. The frictional force against combing before and after using the hair shampoo and the essence for normal hair tress and damaged hair tress was significantly changed. The combing force was increased for normal hair tress and decreased for damaged hair tress. In conclusion, we suggest that keratin peptides are appropriated as cosmetic ingredients to be used in hair and scalp related products.

Tensile Strength of Composite Laminate Repaired Using Heat-blanket and a Novel Pressurization System (히트블랑켓과 새롭게 개발된 가압장치를 이용해 수리한 복합재 적층판의 인장강도 연구)

  • Chae, Song-Su;Lee, Gwang-Eun;Ahn, Hyonsu;Choi, Jin-Ho;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • In the case of a conventional composite patch repair using a heat blanket, the adhesive is pressurized using only a vacuum bag. In this study, however, a pressurization system has been developed to apply additional air pressure on the vacuum bag. In order to verify the performance of the developed system, the composite laminates were repaired with scarf patches and then tested under tensile load to be compared with the strength of the defect-free laminate. Tensile tests were also conducted on specimens with the same configuration but bonded in an autoclave. As a result of the test, the tensile strengths of the specimens repaired using the heat blanket with vacuum only without external pressure, the specimens repaired with additional pressure by the developed system, and the specimens repaired with the same external pressure in an autoclave, showed the strength recovery ratios of 74.9, 81.0, and 78.2%, respectively. The results of the tensile test after moisture saturation and the dried fatigue test also showed that the strength recovery ratios of the specimens repaired under the external pressure of 1 atm using the developed system are slightly higher than that of specimens bonded in autoclave.

Effect of Micro-bolt Reinforcement for Composite Scarf Joint (복합재 스카프 조인트에서의 마이크로 볼트 보강에 대한 타당성 연구)

  • Lee, Gwang-Eun;Sung, Jung-Won;Kweon, Jin-Hwe
    • Composites Research
    • /
    • v.32 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • The reinforcement effect of micro-bolt for a bonded scarf joint was investigated. Three scarf ratios of 1/10, 1/20, and 1/30 were considered to examine the effect of scarf patch configuration on joint strength. To maintain the same density of micro-bolt, 16, 32, and 48 bolts were installed in the scarf joint specimens with scarf ratios of 1/10, 1/20, and 1/30, respectively. Tests were also carried out on the joints that are bonded with only adhesive and that are fastened with only micro-bolts to obtain reference values. The average failure loads of the adhesive joints with scarf ratios of 1/10, 1/20, and 1/30 were 29.7, 39.6, and 44.8 kN, respectively. In case of micro-bolt reinforcement, the failure loads at the same scarf ratios were 28.4, 37.2, and 40.1 kN, respectively, which corresponds to 96, 94, and 90% of the pure adhesive joint failure loads. In the case of using only micro-bolts, the failure loads were only 13-25% of the average failure loads of pure adhesive joints. Fatigue test was also conducted for the joints with scarf ratio of 1/10. The results show that the fatigue strength of hybrid joints using both adhesive and microbolts together slightly increased compared to the fatigue strength of adhesive joint, but the rate of increase was small to 2-3%. Through this study, it was confirmed that the reinforcement effect of micro-bolt is negligible in the scarf joints where shear stress is dominating the failure, unlike in the structure where peel stress is dominant.

Effects of Alcohol on Psychomotor Performance and Subjective Assessments In Normal Adults with Variation of Acetaldehyde Dehydrogenase I (정상성인에서 ALDH-I의 변이가 알콜의 정신운동성 수행과 주관적 평가에 미치는 영향)

  • Yoon, Bo Hyun;Yoon, Jin Sang
    • Korean Journal of Biological Psychiatry
    • /
    • v.3 no.2
    • /
    • pp.222-239
    • /
    • 1996
  • The purpose of this study was to evaluate the effects of alcohol on the psychomotor performance and subjective assessment in healthy Korean adults with acetaldehyde dehydrogenase I(ALDH-I) isozyme variance. A total of 20 male subjects, half with active ALDH-I and the other half with inactive ALDH-I, were selected through both a self-reporting questionnaire examining alcohol sensitivity and the Higuchi's ethanol patch test detecting ALDH-I deficiency. In a doule-blind, placebo-controlled cross-over design, each subject consumed four doses of alcohol(0.25, 0.5, 0.75, 1.0g/kg) and placebo on five separate occasions at weekly intervals, Treatment order was fully balanced using a $5{\times}5$ Latin square, Psychomotor performance tests[coritical flicker fusion threshold(CFF) and choice reaction time(CRT)] and self-estimate questionnaires were conducted at baseline and at time points of 20, 40, 60, 90, 120, 150, 180 minutes after consuming the test drug for 20 minutes, Blood alcohol concentrations(BACs) using breath analyzer were measured at baseline and at time points of 10, 20, 30, 40, 50, 60, 75, 90, 105, 120, 150, 180 minutes after drinking, The BACs and the mean changes in the psychomotor performances and subjective assessments from pre-alcohol baseline, were compared between the two groups. The findings were summarized as follows : 1) BACs were tended to be higher in the inactive group than the active in all of the four alcohol doses. However significant group differences were only after the 0.5g/kg dose of alcohol. 2) The inactive group showed significant impairment in CFFT at most time points alter 0.75 and 1.0g/kg doses of alcohol. 3) In CRT, total reaction time(TRT) significantly prolonged in the inactive group than the active group at 20 minutes after 0.25 and 1.0g/kg doses of alcohol and at 40, 60, 90 minutes alter 0.75g/kg dose of alcohol. In the inactive group, recognition time component significantly increased at 20, 60, 90 minutes after 1.0g/kg dose of alcohol, while movement time component significantly increased at 40, 60 minutes after 0.75g/kg dose of alcohol. 4) Subjective evaluation of the effect of alcohol revealed that physical and mental conditions as well as a self-estimate of the effects of alcohol on performance were significantly worse in the inactive group than the active at some time points alter all of the lour alcohol doses, wihch were more pronounced after 0.75 and 1.0g/kg doses of alcohol. 5) Most of the group differences mentioned above, still remained statistically significant after BAC was entered as a covariate, These findings demonstrated that the alcohol sensitivity is higher in individuals with inactive ALDH-I than those with active ALDH-I both on the subjective assessments and the objective psychomotor performances. Furthermore, these results suggest thai the alcohol sensitivity may be determined by acetaldehyde concentration rather than BAC per se. In future studies, after more accurate genotyping for ALDH-I, the relationships between BAC, acetaldehyde concentration and alcohol sensitivities should be clearly defined.

  • PDF

Development of an Eye Patch-Type Biosignal Measuring Device to Measure Sleep Quality (수면의 질을 측정하기 위한 안대형 생체신호 측정기기 개발)

  • Changsun Ahn;Jaekwan Lim;Bongsu Jung;Youngjoo Kim
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.12 no.5
    • /
    • pp.171-180
    • /
    • 2023
  • The three major sleep disorders in Korea are snoring, sleep apnea, and insomnia. Lack of sleep is the root of all diseases. Some of the most serious potential problems associated with sleep deprivation are cardiovascular problems, cognitive impairment, obesity, diabetes, colitis, prostate cancer, etc. To solve these problems, the Korean government provided low-cost national health insurance benefits for polysomnography tests in July 2018. However, insomnia patients still have problems getting treated in terms of time, space, and economic perspectives. Therefore, it would be better for insomnia patients to be allowed to test at home. The measuring device can measure six biosignals (eye movement, tossing and turning, body temperature, oxygen saturation, heart rate, and audio). A gyroscope sensor (MPU9250, InvenSense, USA) was used for eye movement, tossing, and turning. The input range of the sensor was in 258°/sec to 460°/sec, and the data range was in the input range. Body temperature, oxygen saturation range, and heart rate were measured by a sensor (MAX30102, Analog Devices, USA). The body temperature was measured in 30 ℃ to 45 ℃, and the oxygen saturation range was 0% for the unused state and 20 % to 90 % for the used state. The heart rate measurement range was in 40 bpm to 180 bpm. The measurement of audio signal was performed by an audio sensor (AMM2742-T-R, PUIaudio, USA). The was -42 dB ±1 dB frequency range was 20 Hz to 20 kHz. The measured data was successfully received in wireless network conditions. The system configuration was consisted of a PC and a mobile app for bio-signal measurement and data collection. The measured data was collected by mobile phones and desktops. The data collected can be used as preliminary data to determine the stage of sleep and perform the screening function for sleep induction and sleep disturbances. In the future, this convenient sleep measurement device could be beneficial for treating insomnia.

The Effects of Autologous Blood Pleurodesis in the Pneumothorax with Persistent Air Leak (지속성 기흉에서 자가혈액을 이용한 흉막유착술의 효과)

  • Yoon, Su-Mi;Shin, Sung-Joon;Kim, Young-Chan;Shon, Jang-Won;Yang, Seok-Chul;Yoon, Ho-Joo;Shin, Dong-Ho;Chung, Won-Sang;Park, Sung-Soo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.6
    • /
    • pp.724-732
    • /
    • 2000
  • Background : In patients with severe chronic lung diseases even a small pneumothorax can result in life-threatening respiratory distress. It is important to treat the attack by chest tube drainage until the lung expands. Pneumothorax with a persistent air leak that does not resolve under prolonged tube thoracostomy suction is usually treated by open operation to excise or oversew a bulla or cluster of blebs to stop the air leak. Pleurodesis by the instillation of chemical agents is used for the patient who has persistent air leak and is not good candidate for surgical treatment. When the primary trial of pleurodesis with common agent fails, it is uncertain which agent should be used f or stopping the air leak by pleurodesis. It is well known that inappropriate drainage of hemothorax results in severe pleural adhesion and thickening. Based on this idea, some reports described a successful treatment with autologous blood instillation for pneumothorax patients with or without residual pleural space. We tried pleurodesis with autologous bood for pneumothorax with persistent air leak and then we evaluated the efficacy and safety. Methods : Fifteen patients who had persistent air leak in the pneumothorax complicated from the severe chronic lung disease were enrolled. They were not good candidates for surgical treatment and doxycycline pleurodesis failed to stop up their air leaks. We used a mixture of autologous blood and 50% dextrose for pleurodesis. Effect and complications were assessed by clinical out∞me, chest radiography and pulmonary function tests. Results : The mean duration of air leak was 18.4${\pm}$6.16 days before ABP (autologous blood and dextrose pleurodesis) and $5.2{\pm}1.68$ days after ABP. The mean severity of pain was $2.3{\pm}0.70$ for DP(doxycycline pleurodesis) and $1.7{\pm}0.59$ for ABDP (p<0.05). There was no other complication except mild fever. Pleural adhesion grade was a mean of $0.6{\pm}0.63$. The mean dyspnea scale was $1.7{\pm}0.46$ before pneumothrax and $2.0{\pm}0.59$ after ABDP (p>0.05). The mean $FEV_1$ was $1.47{\pm}1.01$ before pneumothorax and $1.44{\pm}1.00$ after ABDP (p>0.05). Except in 1 patient, 14 patients had no recurrent pneumothorax. Conclusion : Autologous blood pleurodesis (ABP) was successful for treatment of persistent air leak in the pneumothorax. It was easy and inexpensive and involved less pain than doxycycline pleurodesis. It did not cause complications and severe pleural adhesion. We report that ABP can be considered as a useful treatment for persistent air leak in the pneumothorax complicated from the severe chronic lung disease.

  • PDF