• Title/Summary/Keyword: patch type

Search Result 496, Processing Time 0.029 seconds

Critical Elastic Buckling Load Investigation of Aluminium Alloy A6082-T6 Square plate Subjected to Patch Loading (패치 로딩을 받는 알루미늄 합금 A6082-T6 사각형 판의 임계 탄성좌굴하중 검토)

  • Oh, Young-Cheol;Ko, Jae-Yong
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.4
    • /
    • pp.451-460
    • /
    • 2014
  • In this paper, we examined the problem of the structural stability according to the patch load of a rectangular plate that reflects the material properties of A6082-T6 is used primarily for marine plant structure. it applied to the four patch loading shapes, the effect of aspect ratio, a boundary condition and calculated the critical elastic buckling load. Calculating the critical elastic buckling load, During the eigenvalue buckling analysis it is applied to the shell181 as 4 node shell element. when the plate subjected to patch loading compare to the plate under a uniform axial compression load, it is possible observed to occur the different elastic buckling behaviour and it could be confirmed that it is affected significantly on a variable position and type of loadings, such as the effect of the aspect ratio. Also, Critical elastic buckling load according to th patch loading type in simply supported rectangular plate a/b=1.0, ${\gamma}b$=200mm are calculated 67%(Loading type I), 119 %(Loading type II), 76 %(Loading type III), 160 %(Loading type IV), respectively. Loading type I and III could be determined with the strong elastic buckling behavior much more than Loading type II and IV.

A Study on Color Code Control Connected with Sound Source and Sensitivity of PA Speaker facility attachable LED Patch (PA스피커 시설물 부착형 LED패치의 음원감성 연계형 컬러코드 제어에 관한 연구)

  • Kim, Youngmin;Shin, Jaekwon;Cha, Jaesang
    • Journal of Satellite, Information and Communications
    • /
    • v.10 no.3
    • /
    • pp.22-25
    • /
    • 2015
  • This paper performs Color Code Control Connected with Sound Source and Sensitivity of PA Speaker facility attachable LED patch. PA speaker delivers the technology to control the color code of LED patch along the present PA speakers for the facility-attached, LED the development of the patch. PA speakers facility attachable color code control technology of LED patch detects the sound from the PA speaker using a check, and if the analog signal source is detected (sound source)by converting the digital signal passes to the main controller can control the color and pattern of LED patches. In this paper, based on the PA speakers LED color control system, sound emotional linkage-type, and follow the lead of the PA speakers through the feelings can effectively channel LED linked to the source type and proceed to experiment with color and emotion control, whether or not they offer via the color control technology LED patch availability. PA speaker facility attachble color code control technology of LED patch connected with the source and future research directions in the field, and as the application is expected to be able to be widely utilized.

Studies on Cultural Characteristics and Pathogenicity of Rhizoctonia spp. and Effect of Fungicides (Rhizoctonia균의 배양특성 및 잔디에 대한 병원성과 살균제의 효과)

  • 이두형;유왕근;한경숙
    • Asian Journal of Turfgrass Science
    • /
    • v.6 no.2
    • /
    • pp.89-98
    • /
    • 1992
  • Cultural characteristics and pathogenicity on the isolates of Rhizoctonia oryzae, R. oryzae-sativae and anastomosis group of R. solani and evaluation of selected fungicides on brown patch disease of creeping bentgrass and large patch disease of zoysia grass were studied comparatively. From effect of temperature on the rate of mycelia growth, the result indicated that the temperature groups were separated into four types : isolates of R. oryzae and R. oryzae-sativae had an optimum temperature of $30~35^{\circ}C$. Anastomosis groups of R. solani were separated into three temperature types as followings : high temperature type had an optimum temperature from 25 to $30^{\circ}C$, moderate type had grown from 20 to $25^{\circ}C$ for optimum and low temperature type had an optimum temperature of $20^{\circ}C$ but at $35^{\circ}C$ did not grow. Inoculation tests showed that AG-1( I A), AG-1( I B), bentgrass isolate of R. solani and R. oryzae were strongly pathogenic on creeping bentgrass, followed by AG-2-1, AG-4, AG-5 and AG-2-2 isolates of R. solani moderately to weakly. Zoysia grass isolate of R. solani and R. oryzae were strongly pathogenic on zoysia grass but AG-1( I B) and AG-5 isolates of R. solani showed moderately pathogenic. Capro(iprodione oxine-copper) and mytan(myclobutanil) were extremely effective against brown patch disease of creeping bentgrass and large patch disease of zoysia grass followed by thiopan (thiopanate-methyl) and pencycuron for brown patch disease and tolos(tolclofos-methyl) and thiopan for large patch disease.

  • PDF

Fatigue Behavior of Cracked Al 6061-T6 Alloy Structures Repaired with Composite Patch

  • Yoon, Young-Ki;Park, Jong-Joon;Kim, Guk-Gi;Yoon, Hi-Seak
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.3
    • /
    • pp.5-10
    • /
    • 2001
  • Due to the development of high-strength fibers and adhesives, it is now possible to repair cracked metallic plates by bonding reinforced patches to the plate over the crack. In this study, pre-cracked aluminum 6061-T6 alloy plates repaired with bonded carbon/epoxy composite patch are applied to investigate the effect of various patch shapes on the tensile strength and the fatigue behavior of the structure. A non-patch-boned cased and 2 type-50$\times$50, 40$\times$20 mm-composite patch-bonded cases were tested to obtain fracture loads and fatigue crack growth rate. The results showed that the patch-bonded repair improves the static strength by 17% and the fatigue life by 200% compared to non-repaired case. It means that patch-boned repair is more effective in the fatigue life. It was also revealed that the patching method along crack growth direction is more efficient in cost and weight reduction. By observing the fractography, patch-bonded repair specimens demonstrated zigzag fracture patterns compared with the non-patched specimens, which shows a typical ductile fracture.

  • PDF

Clinical Outcomes of Diverse Patch Grafts (광범위 회전근개 파열의 봉합술에서 Patch Graft 종류별 임상적 결과)

  • Lho, Taewoo;Chung, Seok Won
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.472-483
    • /
    • 2021
  • With increased development of patch graft, the number of repair using patch graft in massive rotator cuff tear has increased. Understanding characteristics of various patch graft might be helpful for selection of type of patch, and to improve the outcomes for the treatment of massive rotator cuff tears using patch grafts. Therefore, this paper reviews various studies dealing with clinical outcomes of rotator cuff repair using diverse patch grafts in massive rotator cuff tears.

Directivity Gain Improvement Method for UWB Coplanar Patch Antenna (UWB 평면 패치안테나의 지향성이득의 향상 방법)

  • Joo, Chang-Bok
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.49 no.6
    • /
    • pp.63-70
    • /
    • 2012
  • This paper discussed on the directive gain improvement method of the U-type ultra wide-band(UWB) planar patch antenna model with CPW feeding. For directive gain improvement, the U-type printed patch antenna model with CPW feeding is reconstructed as a microstrip structure by adding a reflection plane with aperture slot. The reflection coefficient of the reconstructed antenna is less than -6.5 dB(VSWR < 3.3) to the characteristic impedance of $50.08{\Omega}$ and showed the directive radiation patterns with the directive gain of 7.5 dBi ~ 10.1 dBi, the front-back ratio of 17.8 dB ~ 28.7 dB and the range of -3dB radiation angle over ${\pm}30^{\circ}$ to the main beam direction of ${\theta}=0^{\circ}$.

Adhesive Polyurethane-based Capacitive Electrode for Patch-type Wearable Electrocardiogram Measurement System (패치형 웨어러블 심전도 측정 시스템을 위한 접착성 폴리우레탄 기반의 용량성 전극)

  • Lee, Jeong Su;Lee, Won Kyu;Lim, Yong Gyu;Park, Kwang Suk
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.203-210
    • /
    • 2014
  • Wearable medical device has been a resurgence of interest thanks to the development of technology and propagation of smart phone in recent years. Various types of wearable devices have been introduced and available in market. Capacitive coupled electrode which measures electrocardiogram over cloth is able to be applied wearable device. In previous approaches of capacitive electrode, they need proper pressure for stable contact of the electrode to body surface. However, wearable device that gives pressure on body surface is not suitable for long-term monitoring. In this study, we proposed adhesive polyurethane-based capacitive electrode for patch-type wearable electrocardiogram (ECG) monitoring device. Self-adhesive polyurethane make the electrode and whole system be adhered to the surface of skin without any pressure. The patch-type system is consisted of analog filter, analog-to-digital converter and wireless transmission module and designed to be attached on the body as a patch. To validate the feasibility of the developed system, we measured ECG signal in stable and active state and extracted heart rate. Therefore, we observed skin response after long-term attachment for biocompatibility of the adhesive polyurethane and adhesive strength of it. The result shows the possibility of applying the developed system for ECG monitoring in real-life.

Design and Fabrication of Array antenna in the WLAN Band (무선랜 대역의 배열 안테나 설계 및 제작)

  • Park, Yong-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.2
    • /
    • pp.779-783
    • /
    • 2012
  • In this paper, we studied the design and fabrication of $2{\times}2$ array-type microstrip patch antenna to be used in wireless communication systems operating at around 5GHz band. To obtain wide bandwidth and high gain, antenna parameters such as patch size, inter patch space are simulated by HFSS(High Frequency Structure Simulator). From these parameters, the $2{\times}2$ array-type microstrip patch antenna is fabricated using FR-4 substrate. The measured results of the antenna are as follows: The center frequency of 5.06GHz, insertion loss of -44dB, bandwidth of 200MHz, and VWSR of 1.1.

Miniaturization of Microstrip Antenna using Iris (Iris를 이용한 마이크로스트립 안테나의 소형화)

  • Seo Jeong-Sik;Woo Jong-Myung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.10 s.89
    • /
    • pp.922-930
    • /
    • 2004
  • In this paper, the 3-dimensional microstrip antenna, where the lis is attached near the patch, on the pound and both patch and ground in zigzag, is designed and fabricated to miniaturize size of antenna. The path of surface current and permittivity in patch are increased because of attached Iris near the patch, on the pound and patch and found. In particula., the maximum size reduction effect among the three-type of $79.1\%$(17 mm$\times$90 mm) was presented in zigzag-type compared with the rectangular microstrip patch antenna(MPA) with a height of 9 mm at the resonant frequency of 1.575 GHz. The gain showed -1.15 dBd, -10 dB bandwidth showed 6.2$\%$(98 MHz), and HPBW of E-plane showed $154^{\circ}$. As that result we could confirm that the 3-dimensional structure with attached Irises is the proper form for the miniaturization of microstrip antenna.

Clinical Results of Surgical Treatment of an Isolated Complete Atrioventricular Septal Defect (완전방실중격결손증의 외과적 요법에 관한 임상적 고찰)

  • 이정상
    • Journal of Chest Surgery
    • /
    • v.24 no.2
    • /
    • pp.123-134
    • /
    • 1991
  • Twenty eight patients had undergone repair of an isolated complete atrioventricular septal defect between April 1986 and September 1990 in Seoul National University Children`s Hospital. The group comprised 13 male and 15 female patients. They ranged in age from 2 months to 8 years[mean 18.6months] and in weight from 3. 4kg to 23kg[mean 9.0$\pm$4.6kg]. They were analysed as Rastelli type A in 17 patients, Rastelli type B in 2 patients, and Rastelli type C in 9 patients. Seven patients had concomitant Down`s syndrome. All patients had large left-to-right shunt[mean pulmonary to systemic flow ratio 3.5 $\pm$2.2 ranging from 0.68 to 10.0] and high pulmonary systolic pressure[mean 74$\pm$18.8mmHg, ranging from 35 to 110]. In 11 patients, one patch technique was used to close the atrial and ventricular septal defect and 16 patients were undergone by two patch technique. We urgently managed only one patient by pulmonary artery banding whose anatomy was Rastelli type C and severe mitral regurgitation was identified. Postoperative complete A - V block was noted in 3 patients, two of whom were dead in operating room due to combined LVOTO and myocardial failure, and one patient with Rastelli type C was undergone by VVI type permanent pacemaker insertion 1wk later after two patch technique, but we had to manage him by modified Konno operation and total correction due to LVOTO and VSD leakage and severe mitral regurgitation 3 years later. Another two reoperation cases due to severe mitral regurgitation after two patch technique were undergone, one of whom we managed by mitral annuloplasty 3 months later but aggravated mitral regurgitation made us to control him by MVR 3 months later. Another one case of VSD leakage and tricuspid regurgitation was managed by total correction but she died of respiratory insufficiency 14 days later. We experienced pulmonary hypertensive crisis in 3 patients, who were dead in two cases comparing with one control case. So operative mortality is 9/27[33.6%], in one patch group of 3/11[29.2%] comparing with two patch group of 6/16[37.5%]. In summary, causes of death were pump weaning failure, myocardial failure and low cardiac output syndrome and pulmonary hypertensive crisis, resp. failure, complete AV block. Mean follow up period is 15.8$\pm$10.7 months[ranging from 3months to 37 months]

  • PDF