• Title/Summary/Keyword: patch test

Search Result 306, Processing Time 0.032 seconds

Allergic to Pool Water

  • Stenveld, Harma
    • Safety and Health at Work
    • /
    • v.3 no.2
    • /
    • pp.101-103
    • /
    • 2012
  • To identify the allergy problem of a 36-year old swimming instructor, who experiences heavy itching and rashes whenever she comes in contact with pool water. Patch tests were performed with European standard series and materials from the work floor. A positive patch test to aluminum chloride and flocculant was observed. Occupational dermatitis is, based on a contact allergy to aluminum chloride in the flocculant.

Higher-order assumed stress quadrilateral element for the Mindlin plate bending problem

  • Li, Tan;Qi, Zhaohui;Ma, Xu;Chen, Wanji
    • Structural Engineering and Mechanics
    • /
    • v.54 no.3
    • /
    • pp.393-417
    • /
    • 2015
  • In this paper an 8-node quadrilateral assumed stress hybrid Mindlin plate element with $39{\beta}$ is presented. The formulation is based on complementary energy principle. The proposed element is free of shear locking and is capable of passing all the patch tests, especially the non-zero constant shear enhanced patch test. To accomplish this purpose, special attention is devoted to selecting boundary displacement interpolation and stress approximation in domain. The arbitrary order Timoshenko beam function is successfully used to derive the boundary displacement interpolation. According to the equilibrium equations, an appropriate stress approximation is rationally derived. Particularly, in order to improve element's accuracy, the assumed stress field is derived by employing $39{\beta}$ rather than conventional $21{\beta}$. The resulting element can be adopted to analyze both moderately thick and thin plates, and the convergence for the very thin case can be ensured theoretically. Excellent element performance is demonstrated by a wide of experimental evaluations.

Multi-mode Noise Reduction of Smart Panels Using Piezoelectric Shunt Damping (압전션트 댐핑을 이용한 지능패널의 다중 모드 소음 저감)

  • 김준형;김재환
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.4
    • /
    • pp.300-307
    • /
    • 2003
  • This paper presents the multi-mode noise reduction of smart panels of which passive piezoelectric shunt damping is introduced. For the piezoelectric shunt damping, a passive shunt circuit composed of inductors and a load resistor is connected to the piezoelectric patch mounted on the panel structure. An electrical impedance model is introduced for the system based on the measured electrical impedance, and the criteria for maximum energy dissipation at the shunt circuit is used to find the optimal shunt parameters. For multi-mode shunt damping, the shunt circuit is modified by the introduction of a block circuit. Also the optimal location of the piezoelectric patch is studied by finite element analysis in order to cause the maximum admittance from the patch for each mode of the structure. An acoustic test is performed for the panels and a remarkable noise reduction is obtained in multiple modes of the panel structure.

Fatigue Characteristics of Aluminum Material Repaired by CFRP Composite (CFRP 복합재로 보수된 알루미늄 재료의 피로특성에 대한 연구)

  • Kim, Man-Tae;Rhee, Kyong-Yop
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.320-323
    • /
    • 2004
  • This work investigated fatigue characteristics of aluminum repaired by CFRP composites. Three specimens, cracked aluminum, cracked aluminum patched by CFRP, and plasma-treated aluminum patched by CFRP were used for the fatigue tests. The results showed that the fatigue crack growth behavior of cracked aluminum was improved by repairing the cracked area with composite patch. Specifically, the specimen repaired by composite patch showed about three times more fatigue life than the cracked aluminum. The plasma-treated aluminum repaired by composite patch showed about five times more fatigue life than the cracked aluminum.

  • PDF

Test Coverage Expansion-based Valid Patch Refinement (테스트 범위 확장 기반 유효 패치 강화)

  • Moon, Junhyeon;Lee, Eunseok
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2019.10a
    • /
    • pp.680-683
    • /
    • 2019
  • 개발자의 부담을 줄이고 소프트웨어의 품질을 향상시키기 위해 APR (Automated Program Repair) 기술을 개선해야 할 필요가 있다. 현재 사용되는 대부분의 APR 기술은 개발자가 수작업으로 작성한 테스트 케이스를 통과하는 유효 패치(Valid Patch)를 만드는 방식을 사용하기 때문에 QoP(Quality of Patch)는 많이 뒤떨어지는 단점을 가지고 있다. 본 논문에서는 테스트 범위가 충분히 높은 테스트 케이스를 자동으로 생성하는 기술을 이용하여 기존의 유효 패치를 강화하는 기술을 제안한다. 제안하는 내용을 Defects4J 의 일부 프로젝트에 적용하여 기존 기법 대비 FL 의 성능은 유지하면서 기존에 찾지 못했던 유효 패치를 추가적으로 찾을 수 있음을 확인하였다.

Paenibacillus elgii SD17 as a Biocontrol Agent Against Soil-borne Turf Diseases

  • Kim, Dal-Soo;Rae, Cheol-Yong;Chun, Sam-Jae;Kim, Do-Hyung;Choi, Sung-Won;Choi, Kee-Hyun
    • The Plant Pathology Journal
    • /
    • v.21 no.4
    • /
    • pp.328-333
    • /
    • 2005
  • Paenibacillus elgii SD17 (KCTC $10016BP^T$=NBRC $100335^T$) was recently reported as a new species. Based on its inhibitory activity to Thanatephorus cucumeris AG1-1, strain SD17 was further evaluated for its potential as a biocontrol agent against soil-borne diseases of turf grasses in Korea. P. elgii SD17 showed a broad spectrum of antimicrobial activity in vitro test and suppressed development of turf grass diseases; Pythium blight caused by Pythium aphanidermatum and brown patch caused by T. cucumeris AG1-1 on creeping bentgrass (Agrostis palustris) in the growth chamber tests. Under a condition for massive culture in a 5,000 L fermenter, P. elgii SD17 reached $6.4{\times}10^8$ spores/ml that resulted in approximately $1.0{\times}10^7$ cfu/g when formulated into a granule formulation (GR) using the whole culture broth instead of water. Using the GR formulation, biocontrol activity of P. elgii SD17 was confirmed. In the growth chamber tests, the GR formulation was effective against brown patch and Pythium blight with similar level of disease severity compared to each of the standard fungicides at the application rates of 10 g/$m^2$ or above. In the field tests, compared to each untreated control, the GR formulation also effectively controlled Pythium blight, brown patch and large patch at all the application rates of 5, 10 and 20 g/$m^2$, respectively, without significant response by the application rates. However its performance was inferior to each of the standard chemical fungicides. Based on these results, we consider this GR formulation of P. elgii SD17 as an effective biocontol agent to suppress Pythium blight, brown patch and large patch of turf grasses in Korea.

Safety Evaluation of Topical Valproate Application

  • Choi, Sun Young;Seop, Song Yi;Hyun, Moo Yeol;Yoo, Kwang Ho;Kim, Beom Joon;Kim, Myeung Nam;Cho, Jae-We
    • Toxicological Research
    • /
    • v.29 no.2
    • /
    • pp.87-90
    • /
    • 2013
  • The potential role of topical valproate (VPA) in hair regrowth has been recently suggested. However, safety reports of VPA as a topical formulation are lacking. Therefore, in the present study, we investigated whether VPA causes skin irritation in humans. We first performed a cell viability test and showed that VPA did not exhibit toxicity toward HaCaT keratinocytes, fibroblasts, and RBL-3H mast cells. We then performed clinical patch test and skin irritation test through transdermal drug delivery with the help of microneedle rollers. No significant findings were obtained in the clinical patch test. In the skin irritation test, only 1 patient showed erythema at 1 hr, but the irritation reaction faded away within a few hours. Erythema and edema were not observed at 24 hr. We concluded that VPA has minimal potential to elicit skin irritation. Therefore, we consider that VPA can safely be applied to human skin.

A Study on Fatigue Crack Growth Analysis of Inclined Cracked Plate with Composite Patched Repair (경사균열을 갖는 복합재료 보강판의 피로균열 성장에 관한 연구)

  • Chung, Ki-Hyun;Yang, Won-Ho;Kim, Cheol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.12
    • /
    • pp.2091-2099
    • /
    • 2001
  • Fatigue crack growth behavior of inclined cracked Al 6061-T6 thick aluminum plate(6mm) repaired with the bonded composite patch was studied. A 0°inclined crack bonded reinforced composite patch and 15°, 30°, 45°, 60°inclined crack plates were tested. The effect of patch and inclined angle were studied and compared to each other. Also we investigated to the crack propagation direction and debonding behavior during the fatigue crack growth test. In this paper. a study was con(ducted to get an fatigue life, fatigue crack growth ratio and crack growth direction. Finally, the effectiveness of composite patch on inclined cracked plate was investigated. The results demonstrated thats there was a definite variation in fatigue life and fatigue crack growth behavior depending on the inclined crack angle.

Pipe Wall Thinning Evaluation through the Arrival Time Delay of A0 Lamb Wave Using Magnetostrictive Patch Transducers

  • Cho, Seung-Hyun;Kwon, Hyu-Sang;Ahn, Bong-Young;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.6
    • /
    • pp.512-518
    • /
    • 2008
  • Guided wave technology is advantageous for fast inspection of pipe wall thinning since the guided wave propagates long distance. In this investigation, the method to evaluate gradual wall thinning in a pipe based on the arrival time delay with magnetostrictive patch transducers is presented. Low frequency A0 Lamb waves were generated and measured by the present transducer and it was applied to arrival time delay measurement experiments on a test pipe having gradual wall thinnings artificially manufactured. From experiments, consistent results that wall thinning increases the arrival time delay of A0 waves were obtained. Consequently, the feasibility of the magnetostrictive patch transducers to evaluate wall thinning was verified.

Dismantled PD diagnosis on 6.6kV Stator Winding by Using Spiral Patch Antenna Sensor (분리된 6.6kV급 고정자 권선의 부분방전 측정을 위한 Spiral 패치 안테나 센서 적용 연구)

  • Lwin, Kyaw Soe;Shin, Dong-Hoon;Lim, Kwang-Jin;Yang, Hoon;Kong, Tae-Sik;Kim, Hee-Dong;Park, Noh-Joon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.211-212
    • /
    • 2007
  • There have three kinds of partial discharge diagnosis testing: online, offline and dismantled testing on high voltage rotating machine. Our lab testing is dismantled testing, taking off pieces into individual parts of stator coil of high voltage rotating machine in laboratory. We investigate internal discharge, slot discharge, corona discharge and normal state on pre-made stator winding by using spiral patch antenna sensor. In this lab test we compare the experimental results of our spiral patch antenna sensor and reference commercial HFCT sensor.

  • PDF