• 제목/요약/키워드: passive range

검색결과 735건 처리시간 0.026초

Effect of Phosphoric Acid on the Electronic and Diffusion Properties of the Anodic Passive Layer Formed on Pb-1.7%Sb Grid of Lead-acid Batteries

  • El-Rahman, H.A. Abd;Salih, S.A.;El-Wahab, A.M. Abd
    • Journal of Electrochemical Science and Technology
    • /
    • 제2권2호
    • /
    • pp.76-84
    • /
    • 2011
  • Potentiostatic oxidation of Pb-1.7%Sb alloy used in the manufacture of grids of lead-acid batteries over the potential range from -1.0V to 2.3V in 5M $H_2SO_4$ in the absence and the presence of 0.4M $H_3PO_4$ and the self-discharge characteristics of the oxide layer formed is studied by electrochemical impedance spectroscopy (EIS). Depending on the potential value, sharp variations in resistance and capacitance of the alloy are recorded during the oxidation and they can be used for identification of the various substances involved in passive layer. Addition of $H_3PO_4$ is found to deteriorate the insulating properties of the passive layer by the retardation of the formation of $PbSO_4$. $H_3PO_4$ completely inhibits the current and impedance fluctuations recorded in $H_3PO_4$-free solutions in the potential range 0.5 V-1.7 V. These fluctuations are attributed to the occurrence of competitive redox processes that involve the formation of $PbSO_4$, $PbOSO_4$, PbO and $PbO_2$ and the repeated formation and breakdown of the passive layer. Self-discharge experiments indicate that the amount of $PbO_2$ formed in the presence of $H_3PO_4$ is lesser than in the $H_3PO_4$-free solutions. The start of transformation of $PbSO_4$ into $PbO_2$ is greatly shortened. $H_3PO_4$ facilitates the diffusion process of soluble species through the passive layer ($PbSO_4$ and basic $PbSO_4$) but impedes the diffusion process through $PbO_2$.

만성 뇌졸중 환자의 보행속도와 보행 비대칭에 영향을 미치는 무릎근력과 발목 관절가동범위 (Knee Strength and Ankle Range of Motion Influencing Gait Velocity and Gait Asymmetry in Patients With Chronic Stroke)

  • 원종임;안창만
    • 한국전문물리치료학회지
    • /
    • 제22권2호
    • /
    • pp.1-10
    • /
    • 2015
  • The common features of walking in patients with stroke include decreased gait velocity and increased asymmetrical gait pattern. The purpose of this study was to identify important factors related to impairments in gait velocity and asymmetry in chronic stroke patients. The subjects were 30 independently ambulating subjects with chronic stroke. The subjects' impairments were examined, including the isokinetic peak torque of knee extensors, knee flexors, ankle plantarflexors, and ankle dorsiflexors. Passive and active ranges of motion (ROM) of the ankle joint, ankle plantarflexor spasticity, joint position senses of the knee and ankle joint, and balance were examined together. In addition, gait velocity and temporal and spatial asymmetry were evaluated with subjects walking at their comfortable speed. Pearson correlations and multiple regressions were used to measure the relationships between impairments and gait speed and impairments and asymmetry. Regression analyses revealed that ankle passive ROM and peak torque of knee flexors were important factors for gait velocity ($R^2=.41$), while ankle passive ROM was the most important determinant for temporal asymmetry ($R^2=.35$). In addition, knee extensor peak torque was the most significant factor for gait spatial asymmetry ($R^2=.17$). Limitation in ankle passive ROM and weakness of the knee flexor were major contributors to slow gait velocity. Moreover, limited passive ROM in the ankle influenced the level of temporal gait asymmetry in chronic stroke patients. Our findings suggest that stroke rehabilitation programs aiming to improve gait velocity and temporal asymmetry should include stretching exercise for the ankle joint.

물리치료사에 의해서 실시되는 도수수동 운동이 자율신경계에 미치는 영향 (The Effects of Manual Passive Exercise Performed by Physical Therapists on Autonomic Nervous System)

  • 김인배;김충유;김은경;신한기;강종호
    • 대한물리의학회지
    • /
    • 제10권1호
    • /
    • pp.9-14
    • /
    • 2015
  • PURPOSE: The purpose of this study was to investigate the effects of ten minutes of manual passive exercise performed by physical therapists on autonomic nervous system. METHODS: Thirty-five healthy adults, both male and female, were chosen as subjects for this study. The autonomic nervous system was measured by heart rate variability (HRV),before and after passive exercise using the following measurements: mean heart rate (mean HRT), low frequency (LF) and high frequency (HF) components, the LF/HF ratio, root mean square of the successive differences (RMSSD), and the HRV index. The exercise was performed on the subjects by a physical therapist with seven years of experience specializing in the nervous system. The exercise was conducted at the mid-range of motion on the upper and lower limbs of the subjects for two minutes and thirty seconds and for a total of ten minutes. RESULTS: There was a significant increase in the LF component. The mean HRT and the LF/HF ratio both increased, but these increases were not significant. The HF component, RMSSD, and HRV index all decreased, but these decreases were not significant. CONCLUSION: In conclusion, mid-range manual passive exercise does not induce stress on the autonomic nervous system. It can safely be performed by a physical therapist.

심해에서의 장거리 다중입출력 수중통신 (Long-range multiple-input-multiple-output underwater communication in deep water)

  • 김동현;김대환;김재수;한주영
    • 한국음향학회지
    • /
    • 제40권5호
    • /
    • pp.417-427
    • /
    • 2021
  • 심해 장거리 통신의 경우, 제한된 대역폭으로 인해 데이터 전송률이 낮아지는 한계가 있다. 본 논문에서는 데이터 전송률을 향상시킬 수 있는 방법인 다중입출력 수중통신 연구 결과를 제시한다. 단일 음원 환경과 달리 다중음원 환경의 경우 다른 음원에 의한 간섭으로 통신 성능이 저하되며, 이를 제거하기 위해 적응형 수동 시역전 처리가 주로 사용되고 있다. 2018년 10월 포항 동방 수심 1,000 m 이상의 심해 해역에서 장거리 수중음향통신 해상실험이 수행되었다. 해상실험 동안 수직 선 배열이 활용되었으며, 512 sps의 binary phase shift keying와 quadrature phase shift keying 변조 신호가 송신되었다. 다중입출력 환경을 모사하기 위해 26 km와 30 km 거리의 데이터를 합성한다. 재래식과 적응형 수동 시역전 처리를 이용한 데이터 분석 및 비교를 통해, 적응형 신호 처리를 적용했을 때 다른 음원에 의한 간섭이 제거되어 0 %의 비트 오류율과 출력 신호 대 잡음비 증가의 효과를 확인하였다. 따라서 두 개의 음원을 가진 다중입출력 통신 성능 분석을 통해 두 배의 데이터 전송률 (1,024 sps)을 획득하였다.

수종 임플랜트 금속의 내식성에 관한 전기화학적 연구 (AN ELECTROCHEMICAL STUDY ON THE CORROSION RESISTANCE OF THE VARIOUS IMPLANT METALS)

  • 전진영;김영수
    • 대한치과보철학회지
    • /
    • 제31권3호
    • /
    • pp.423-446
    • /
    • 1993
  • Titanium and its alloys are finding increasing use in medical devices and dental implants. The strong selling point of titanium is its resistance to the highly corrosive body fluids in which an implant must survive. This corrosion resistance is due to a tenacious passive oxide or film which exists on the metal's surface and renders it passive. Potentiodynamic polarization measurement is one of the most commonly used electro-chemical methods that have been applied to measure corrosion rates. And the potentiodynamic polarization test supplies detailed information such as open circuit, rupture, and passivation potential. Furthermore, it indicates the passive range and sensitivity to pitting corrosion. This study was designed to compare the corrosion resistance of the commonly used dental implant materials such as CP Ti, Ti-6A1-4V, Co-Cr-Mo alloy, and 316L stainless steel. And the effects of galvanic couples between titanium and the dental alloys were assessed for their useful-ness-as. materials for superstructure. The working electrode is the specimen , the reference electrode is a saturated calomel electrode (SCE), and the counter electrode is made of carbon. In $N_2-saturated$ 0.9% NaCl solutions, the potential scanning was performed starting from -800mV (SCE) and the scan rate was 1 mV/sec. At least three different polarization measurements were carried out for each material on separate specimen. The galvanic corrosion measurements were conducted in the zero-shunt ammeter with an implant supraconstruction surface ratio of 1:1. The contact current density was recorded over a 24-hour period. The results were as follows : 1. In potential-time curve, all specimens became increasingly more noble after immersion in the test solution and reached between -70mV and 50mV (SCE) respectively after 12 hours. 2. The Ti and Ti alloy in the saline solution were most resistant to corrosion. They showed the typical passive behavior which was exhibited over the entire experimental range. Therefore no breakdown potentials were observed. 3. Comparing the rupture potentials, Ti and Ti alloy had the high(:st value (because their break-down potentials were not observed in this study potential range ) followed by Co-Cr-Mo alloy and stainless steel (316L). So , the corrosion resistance of titanium was cecellent, Co-Cr-Mo alloy slightly inferior and stainless steel (316L) much less. 4. The contact current density sinks faster than any other galvanic couple in the case of Ti/gold alloy. 5. Ag-Pd alloy coupled with Ti yielded high current density in the early stage. Furthermore, Ti became anodic. 6. Ti/Ni-Cr alloy showed a relatively high galvanic current and a tendency to increase.

  • PDF

Analysis and Implementation of a New Single Switch, High Voltage Gain DC-DC Converter with a Wide CCM Operation Range and Reduced Components Voltage Stress

  • Honarjoo, Babak;Madani, Seyed M.;Niroomand, Mehdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제18권1호
    • /
    • pp.11-22
    • /
    • 2018
  • This paper presents a single switch, high step-up, non-isolated dc-dc converter suitable for renewable energy applications. The proposed converter is composed of a coupled inductor, a passive clamp circuit, a switched capacitor and voltage lift circuits. The passive clamp recovers the leakage inductance energy of the coupled inductor and limits the voltage spike on the switch. The configuration of the passive clamp and switched capacitor circuit increases the voltage gain. A wide continuous conduction mode (CCM) operation range, a low turn ratio for the coupled inductor, low voltage stress on the switch, switch turn on under almost zero current switching (ZCS), low voltage stress on the diodes, leakage inductance energy recovery, high efficiency and a high voltage gain without a large duty cycle are the benefits of this converter. The steady state operation of the converter in the continuous conduction mode (CCM) and discontinuous conduction mode (DCM) is discussed and analyzed. A 200W prototype converter with a 28V input and a 380V output voltage is implemented and tested to verify the theoretical analysis.

Effect of postural change on shoulder joint internal and external rotation range of motion in healthy adults in their 20s

  • Kim, Beom-Ryong;Yi, Dong-Hyun;Yim, Jong-Eun
    • Physical Therapy Rehabilitation Science
    • /
    • 제8권3호
    • /
    • pp.152-157
    • /
    • 2019
  • Objective: We aimed to investigate differences of range of motion in measuring shoulder internal rotation (IR) and external rotation (ER) resulting from posture change in manual scapular stabilization in prone, hook-lying, sitting, and standing positions in healthy young adults. Design: Cross-sectional study. Methods: This study included healthy young adults who agreed to participate after a thorough explanation about the study purpose and methods. A clinometer was used to measure shoulder rotation. Measurements of shoulder rotation according to postural change were performed in prone, hook-lying, sitting, and standing positions. The repeated measures analysis of variance was used to compare between-group differences in postural change. Results: The lower the posture, the greater the average value of IR angle. In contrast, the higher the posture, the greater the average value of the external rotation angle. In active and passive IR with posture change, there was difference in average value but with no statistical significance. In active and passive ER, there was a statistically significant difference between prone and sitting, prone and standing, hook-lying and sitting, hook-lying and standing, and sitting and standing position (p<0.05). Conclusions: Our findings suggest that postural change should be considered in order to increase the strength or range of motion of the internal and external rotation of the patient's shoulder joint.

한국주변 어장에서의 수동어탐에 관한 연구 ( I ) - 이론적 고찰 - (A Study on Passive Fish Finder in the Fishing Grounds near the Korean Peninsula - The Theoretical Study for Passive Fish Finder -)

  • 김성부;장지원
    • 수산해양기술연구
    • /
    • 제22권1호
    • /
    • pp.6-10
    • /
    • 1986
  • 우리 나라 주변어장에서의 주요 어자원중 조기류가 수동어탑을 위한 대표적 어종으로 부각되었다. 음원수준을 150~180dB로 가정했을 때 선배열 형의 수동어탐기에 탐지될 수 있는 거리는 최저 3km에서 최대 20km 이상으로 추정되어 어탐거리의 획기적 증대가 기대된다. 뿐만 아니라 조기류가 내는 700~800Hz 사이의 tocal noise의 특성은 수동형 어탐기에 의한 어종식별 거리 및 정밀도를 보다 향상시킬 것임이 분명하다. 다만, 이 수동소나를 조기류외에 대형어군을 이루는 멸치, 칼치, 명태류, 쥐취류, 오징어 등에 적용 여부를 가늠하기에는 보다 많은 정량적 자료가 수집된 연후에 가능할 것으로 믿어진다.

  • PDF

A new hybrid vibration control methodology using a combination of magnetostrictive and hard damping alloys

  • Buravalla, Vidyashankar R.;Bhattacharya, Bishakh
    • Smart Structures and Systems
    • /
    • 제3권4호
    • /
    • pp.405-422
    • /
    • 2007
  • A new hybrid damping technique for vibration reduction in flexible structures, wherein a combination of layers of hard passive damping alloys and active (smart) magnetostrictive material is used to reduce vibrations, is proposed. While most conventional vibration control treatments are based exclusively on either passive or active based systems, this technique aims to combine the advantages of these systems and simultaneously, to overcome the inherent disadvantages in the individual systems. Two types of combined damping systems are idealized and studied here, viz., the Noninteractive system and the Interactive system. Frequency domain studies are carried out to investigate their performance. Finite element simulations using previously developed smart beam elements are carried out on typical metallic and laminated composite cantilever beams treated with hybrid damping. The influence of various parameters like excitation levels, frequency (mode) and control gain on the damping performance is investigated. It is shown that the proposed system could be used effectively to dampen the structural vibration over a wide frequency range. The interaction between the active and passive damping layers is brought out by a comparative study of the combined systems. Illustrative comparisons with 'only passive' and 'only active' damping schemes are also made. The influence and the mode dependence of control gain in a hybrid system is clearly illustrated. This study also demonstrates the significance and the exploitation of strain dependency of passive damping on the overall damping of the hybrid system. Further, the influence of the depthwise location of damping layers in laminated structures is also investigated.

조기 수동적 하지 관절운동이 뇌졸중 후 편마비 환자의 하지 관절가동범위와 발부종에 미치는 효과 (Effects of Early Passive ROM Exercise on ROM of Lower Extremities and Foot Edema in Hemiplegia Patients with Stroke)

  • 이주선;이은옥;이은주;김행수
    • 임상간호연구
    • /
    • 제17권1호
    • /
    • pp.81-89
    • /
    • 2011
  • Purpose: The purpose of this study was to examine the effects of early passive range of motion (ROM) exercise on ROM of lower extremities and foot edema in hemiplegic patients after stroke. Methods: The data were collected between August 2009 and April 2010 from 11 patients in the experimental group and 13 in the control group. The passive ROM exercise was performed twice a day for 2 weeks. Results: In the experimental group, ROM of lower extremities (flexion of hip, flexion of knee and ankle) increased significantly compared to that of the control group. There was no significant difference in foot edema between the two groups. Conclusion: The results indicated that the early passive ROM exercise can improve the ROM of lower extremities, but not the foot edema in patients after stroke.