• Title/Summary/Keyword: passive range

Search Result 731, Processing Time 0.029 seconds

Intra- and Inter-Rater Reliability of Measuring Passive Range of Shoulder Motion With Smartphone and Goniometer in Patients With Stroke (뇌졸중 환자의 수동적 어깨 관절 가동범위 측정에 관한 스마트폰과 측각기의 측정자내, 측정자간 신뢰도 연구)

  • Park, Il-Woo;Lim, One-Bin;Park, Kyue-Nam;Yi, Chung-Hwi
    • Physical Therapy Korea
    • /
    • v.21 no.1
    • /
    • pp.1-12
    • /
    • 2014
  • The purpose of this study were to determine the intra-rater and inter-rater reliability of shoulder passive range of motion measurement using the "Clinometer + bubble level", a smartphone application and to compare with the intra-rater and inter-rater reliability of measurement using a goniometer. Twenty six patients with stroke were recruited for this study. Two raters measured the passive range of motion of four types of shoulder movements (forward flexion; FF, abduction; ABD, external rotation at $90^{\circ}$ abduction; ER90 and internal rotation at $90^{\circ}$ abduction; IR90) using a goniometer and a smartphone to determine within-day inter-rater reliability. A retest session was performed thirty minutes later to determine within-day intra-rater reliability. The reliability was assessed using intraclass correlation coefficients (ICC) and the standard error of measurement (SEM). The ICC (2,1) for the inter-rater reliabilities of the goniometer and smartphone were good in FF and ABD [ICC (2,1)=.75~.87] and excellent in ER90 [ICC (2,1)=.90~.95]. The intra-rater reliabilities for the goniometer and smartphone were good or more than good, with an ICC (3,1) value >.75, the exception was IR90 measured by rater 2 on the smartphone. These results suggest that smartphone could be used as an alternative method tool for measurement of passive shoulder range of motion in patients with stroke.

The Immediate Effects of Unilateral Contract-Relax Stretching on Contralateral Knee Extension Range -A Preliminary Study- (한쪽 다리에 적용한 수축-이완 기법이 반대쪽 무릎관절 폄 범위에 미치는 효과 -예비연구-)

  • Shin, Seung-Sub
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.263-274
    • /
    • 2019
  • Purpose: This article was conducted to determine the immediate effects of unilateral contract-relax (CR) stretching on contralateral knee extension range and to compare both sides of the knee extension range between experimental and control groups. Methods: This study recruited 16 adult males and females with straight leg raising abilities below $90^{\circ}$. The subjects were randomly divided into an experimental group and a control group comprising 8 subjects each. The experimental group performed direct CR stretching on the right hamstring muscles with straight hip extension adduction, and the control group performed indirect CR stretching on the right hamstring muscles with straight hip flexion abduction. Each group performed CR stretching 4 times with 4 repetitions comprising 10 sec of contraction and a 10 sec break between repetitions. Before and after the CR stretching exercises, the subjects' passive knee extensions were measured at the hip in a $90^{\circ}$ flexed position. The subjects' peak force on the right leg and peak pressure on the left leg during each CR stretching exercise were also measured. Results: After doing CR stretching 4 times, each group showed a significantly increased passive knee extension range on both sides, and there was no difference in the passive knee extension ranges between the groups. The peak force on the right leg was significantly higher in the experimental group than the control group. There was no difference in peak pressure between the groups. Conclusion: After applying unilateral CR stretching, the study subjects experienced a significantly increased passive knee extension range on the contralateral side. For patients who find it difficult to apply stretching techniques to knee joints directly, the use of the proprioceptive neuromuscular facilitation technique of CR stretching may be useful in improving the range of the knee joint on the contralateral side without direct treatment.

Estimation of Mobilized Passive Earth Pressure Depending on Wall Movement in Sand (모래지반에서 벽체의 변위에 따른 수동측토압 산정)

  • Kim, Tae-O;Park, Lee-Keun;Kim, Tae-Hyung
    • Journal of the Korean Geotechnical Society
    • /
    • v.36 no.11
    • /
    • pp.51-60
    • /
    • 2020
  • Estimation of passive earth pressure is an important factor in anchor block, temporary retaining wall and support block of raker that resist lateral earth pressure. In practice, due to ease of use, it is common to estimate the earth pressure using the theory of Coulomb and Rankine, which assumes the failure plane as a straight line. However, the passive failure plane generated by friction between the wall surface and the soil forms a complex failure plane: a curve near the wall and a flat plane near the ground surface. In addition, the limit displacement where passive earth pressure is generated is larger compared to where the active earth pressure is generated. Thus, it is essential to calculate the passive earth pressure that occurs at the allowable displacement range in order to apply the passive earth pressure to the design for structural stability reasons. This study analyzed the mobilized passive earth pressured to various displacement ranges within the passive limit displacement range using the semi-empirical method considering the complex failure plane.

Numerical Study of Passive Control with Slotted Blading in Highly Loaded Compressor Cascade at Low Mach Number

  • Ramzi, Mdouki;Bois, Gerard;Abderrahmane, Gahmousse
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.97-103
    • /
    • 2011
  • With the aim to increase blade loadings and stable operating range in highly loaded compressors, this article has been conducted to explore, through a numerical parametric study, the potential of passive control using slotted bladings in cascade configurations. The objective of this numerical investigation is to analyze the influence of location, width and slope of the slots and therefore identify the optimal configuration. The approach is based on two dimensional cascade geometry, low speed regime, steady state and turbulent RANS model. The results show the efficiency of this passive technique to delay separation and enhance aerodynamic performances of the compressor cascade. A maximum of 28.3% reduction in loss coefficient have been reached, the flow turning is increased with approximately $5^0$ and high loading over a wide range of angle of attack have been obtained for the optimized control parameter.

Passive Films on Chromium Studied by Three-parameter Ellipsometry

  • 이경희;백운기
    • Bulletin of the Korean Chemical Society
    • /
    • v.16 no.3
    • /
    • pp.214-216
    • /
    • 1995
  • Passive films formed on chromium surface in citrate buffer solution were investigated by means of three-parameter ellipsometry. The citrate buffer was found to be a suitable medium in which oxide film on chromium could be removed by cathodic treatment, providing a reference surface for the optical study. The passive film effectively protecting the chromium surface from corrosion was found to have thicknesses in the range 0.65 to 1.25 nm depending on the potential in the range of -0.20 to 0.60 V (0.1M KCl calomel electrode). The complex refractive index of the passive film did not show significant potential-dependent changes, indicating that the composition of the film material does not depend on potential.

Immediate Effects of Various Contract-Relax Techniques on the Peck Force and Range of Motion of Knee Extension -A Pilot Study- (수축-이완 기법 방법에 다른 최대 힘과 무릎관절 가동 범위에 미치는 즉각적인 효과 비교 -예비연구-)

  • Shin, Seung-Sub
    • PNF and Movement
    • /
    • v.16 no.2
    • /
    • pp.229-238
    • /
    • 2018
  • Purpose: This study aimed to compare the immediate effects of various contract-relax (CR) techniques on the peck force and passive range of motion (ROM) of knee extension. Methods: This study recruited 17 adult males and females who obtained below $90^{\circ}$ in straight leg raising. The subjects randomly performed one of three different CR techniques (direct CR, indirect CR, and modified CR) on the right knee extension four times per day for three days. The subjects' peck force during each CR and their passive knee extension on the hip at a $90^{\circ}$ flexed position before and after each CR were measured. Results: The peck force was significantly higher in the direct and modified CR than in the indirect CR. The ROM in the passive knee extension significantly increased after direct and indirect CR. Comparing between each CR, the passive knee extension range was significantly more improved in the direct and indirect CR than in the modified CR. Conclusion: Direct and indirect CR are more effective than modified CR in the ROM of passive knee extension. The study results suggest that the modified CR did not have the same effect on the ROM of the knee extension as the direct and indirect CR and that further research is needed to recruit more subjects and to determine the effects on different muscles after modified CR.

Concurrent Validity of a Universal Goniometer and a Double Meter Inclinometer for Passive Range of Motion in Beagle Dogs

  • Heo, Su-Young;Park, Yun-Sik;Lee, Hae-Beam
    • Journal of Veterinary Clinics
    • /
    • v.34 no.4
    • /
    • pp.241-244
    • /
    • 2017
  • The purpose of this study was to evaluate the concurrent validity of the double meter inclinometer (DMI) for passive joint range of motion (ROM) in beagle dogs and to compare these results to a universal plastic goniometer (UPG). Fifteen beagle dogs were recruited for this study. Joint ROM was evaluated twice with each device to calculate the intraobserver reliability. The intraclass correlation coefficient (ICC) values of the UPG were good to excellent (> 0.75) for all joint ROM tests. Similar results were obtained with the DMI. The ICC values of the DMI were good to excellent (> 0.75) except in extension of the tarsal joint (ICC = 0.69). The majority of the ICC results between each device were poor (< 0.50) with the exception of six joints. Our findings suggest that the inclinometer can be used for passive joint ROM in veterinary medicine. However, caution should be taken when comparing measured values of passive joint ROM obtained utilizing both the DMI and UPG.

Passive homing performance improvement in the terminal engagement phase (종말단계에서의 수동호밍 성능개선연구)

  • 송택렬
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.351-354
    • /
    • 1996
  • A new target adaptive guidance (TAG) algorithm is proposed to engage the aim point formed by adding a bias to the information from an infrared (IR) seeker for improving passive homing guidance effectiveness. The TAG algorithm utilizes an observability enhancing mid-course guidance algorithm to obtain convergent estimates of state variables involved particularly in range channel otherwise unavailable from passive sensors. Simulation results indicate that the TAG algorithm provides improved terminal effectiveness without computational complexities.

  • PDF

An Experimental Study on Feasibility of Actively Tuned Passive Control in a Liquid Ramjet Engine (액체 램제트 엔진에서 Actively Tuned Passive Control 가능성의 실험적 연구)

  • Song, Jae-Cheon;Song, Jin-Kwan;Hwang, Jeong-Jae;Yoon, Young-Bin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2009.05a
    • /
    • pp.107-110
    • /
    • 2009
  • Combustion oscillations are caused by a coupling between acoustic waves and unsteady heat release. They can be eliminated using passive controller such as a helmholtz resonator. But, helmholtz resonator is normally only effective over a narrow frequency range. In this work, helmholtz resonator is applied for reducing the combustion oscillations and we vary the helmholtz resonator volume using piston in oder to tune in the wide range of operating conditions. As the result, it is found that the dominant combustion oscillations can be reduced by optimizing the size of resonator volume. Also, from these results, we investigate feasibility of actively tuned passive control

  • PDF

Directivity Pattern Design of a Vehicle Tag Antenna for Improvement of the Readable Range (인식 거리 개선을 위한 차량용 태그 안테나의 지향성 설계)

  • Park, Dae-Hwan;Min, Kyeong-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.8
    • /
    • pp.872-879
    • /
    • 2010
  • This paper describes the design for radiation pattern directivity of vehicle license plate RFID tag antenna to improve the readable range. Directivity pattern of the proposed passive antenna is decided by the meander line position and the bumper size attached to the tag antenna. In order to prove the verification of the calculated directivity pattern and readable range of the proposed antenna, the tag antenna has been fabricated and measured at the anechoic chamber. It is shown that the maximum directivity gain of the measured radiation pattern of active and passive tag antenna were observed 2.32 dBi and 3.1 dBi, respectively. The maximum readable range of passive tag antenna was measured about 8.5 m at ${\pm}45^{\circ}$ beam direction on the basis of the driving car direction($0^{\circ}$ of azimuth angle).