• 제목/요약/키워드: passive damper connection

검색결과 10건 처리시간 0.023초

빌딩간 연결을 통한 복합제어시스템의 최적설계 (Optimal Design of Hybrid Control System through Inter-Building Connection)

  • 박관순;옥승용
    • 한국안전학회지
    • /
    • 제32권6호
    • /
    • pp.81-88
    • /
    • 2017
  • This study deals with the optimal design of a hybrid control system composed of a combination of active control system and passive control system for effective seismic performance improvement of two adjacent structures. The proposed hybrid control system adopts a configuration of installing an active control device in one building and connecting two adjacent structures with a passive control device so that the one-side active control force can be bi-directionally applied to both buildings through the passive connecting devices. In order to derive the optimal performance of the proposed system, the design parameters of the passive and active control systems were searched using the genetic algorithm. Numerical simulations of 10-story and 8-story buildings have been performed to verify the effectiveness of the proposed technique. For the purpose of comparison, the conventional independent control system with two identical active control systems being installed separately for each structure was also optimally designed and its seismic response has been evaluated as well. From the comparative results of the two control systems, it is demonstrated that the proposed hybrid control system requires larger control force for its one-side active control device than the conventional independent control system does for each of both-side active devices, but quite less than the total control force required for both-side devices of the independent control system, while maintaining similar seismic performance. Therefore, the proposed system is more economical and reliable than the conventional independent control system with two identical active devices.

마찰 슬라이딩 거동을 보이는 건물 내 중량 설비의 내진성능 향상을 위한 감쇠기 연결 방안 (Damper Configuration for Seismic Performance Improvement of Heavy Facilities with Frictional Sliding Behavior inside Building)

  • 옥승용;박관순;이지호
    • 한국안전학회지
    • /
    • 제35권1호
    • /
    • pp.53-61
    • /
    • 2020
  • This study proposes a new damper configuration for seismic performance improvement of heavy sliding facilities inside a building. For this purpose, we deal with two connection types of control system, and the parametric study has been performed to investigate their comparative seismic performances according to the variations of the control capacity. In order to simulate the seismic responses of the proposed system, we employed a recently-developed seismic response analysis method that can deal with the two-mass system with nonlinear frictional sliding behavior. The numerical results demonstrate that the typical method of diagonal bracing damper connection can exhibit effective control performance both on structure and the heavy sliding facilities, whereas the structure-facilities connection method does not show any control effect on both responses. On the other hand, the typical method has some limitations that it can adversely cause excessive sliding of the facilities, depending upon the frequency characteristics of structure and earthquake. On the contrary, the structure-facilities connection method is very effective in reducing the sliding displacement of the heavy facilities, even with small amount of control capacity. Thus, the following potential expectations can be inferred from these results: The typical diagonal bracing damper connection method will have some promising benefits in controlling the sliding facilities inside the building as well as the building itself, and the structure-facilities connection method can be a cost-effective way of protecting the internal heavy important facilities inside the structure already designed with sufficient seismic performance.

Smart passive control of buildings with higher redundancy and robustness using base-isolation and inter-connection

  • Murase, Mitsuru;Tsuji, Masaaki;Takewaki, Izuru
    • Earthquakes and Structures
    • /
    • 제4권6호
    • /
    • pp.649-670
    • /
    • 2013
  • It is known that a base-isolated building exhibits a large response to a long-duration, long-period wave and an inter-connected system without base-isolation shows a large response to a pulse-type wave. To compensate for each deficiency, a new hybrid passive control system is investigated in which a base-isolated building is connected to another building (free wall) with oil dampers. It is demonstrated that the present hybrid passive control system is effective both for pulse-type ground motions and long-duration and long-period ground motions and has high redundancy and robustness for a broad range of disturbances.

Two-level control system of toggle braces having pipe damper and rotational friction damper

  • Ata Abdollahpour;Seyed Mehdi Zahrai
    • Structural Engineering and Mechanics
    • /
    • 제86권6호
    • /
    • pp.739-750
    • /
    • 2023
  • This study examines the two-level behavior of the toggle brace damper within a steel frame having a yielding pipe damper and rotational friction damper. The proposed system has two kinds of fuse for energy dissipation in two stages. In this mechanism, rotational friction damper rather than hinged connection is used in toggle brace system, connected to a pipe damper with a limited gap. In order to create a gap, bolted connection with the slotted hole is used, such that first a specific movement of the rotational friction damper solely is engaged but with an increase in movement, the yielding damper is also involved. The performance of the system is such that at the beginning of loading the rotational friction damper, as the first fuse, absorbs energy and with increasing the input load and further movement of the frame, yielding damper as the second fuse, along with rotational friction damper would dissipate the input energy. The models created by ABAQUS are subjected to cyclic and seismic loading. Considering the results obtained, the flexibility of the hybrid two-level system is more comparable to the conventional toggle brace damper. Moreover, this system sustains longer lateral displacements. The energy dissipation of these two systems is modeled in multi-story frames in SAP2000 software and their performance is analyzed using time-history analysis. According to the results, permanent relocations of the roof in the two-level system, in comparison with toggle brace damper system in 2, 5, and 8-story building frames, in average, decrease by 15, 55, and 37% respectively. This amount in a 5-story building frame under the earthquakes with one-third scale decreases by 64%.

Vibration mitigation of stay cable using optimally tuned MR damper

  • Huang, Hongwei;Sun, Limin;Jiang, Xiaolu
    • Smart Structures and Systems
    • /
    • 제9권1호
    • /
    • pp.35-53
    • /
    • 2012
  • Mechanical dampers have been proved to be one of the most effective countermeasures for vibration mitigation of stay cables in various cable-stayed bridges over the world. However, for long stay cables, as the installation height of the damper is restricted due to the aesthetic concern, using passive dampers alone may not satisfy the control requirement of the stay cables. In this connection, semi-active MR dampers have been proposed for the vibration mitigation of long stay cables. Although various studies have been carried out on the implementation of MR dampers on stay cables, the optimal damping performance of the cable-MR damper system has yet to be evaluated. Therefore, this paper aims to investigate the effectiveness of MR damper as a semi-active control device for the vibration mitigation of stay cable. The mathematical model of the MR damper will first be established through a performance test. Then, an efficient semi-active control strategy will be derived, where the damping of MR damper will be tuned according to the dynamic characteristics of stay cable, in order to achieve optimal damping of cable-damper system. Simulation study will be carried out to verify the proposed semi-active control algorithm for suppressing the cable vibrations induced by different loading patterns using optimally tuned MR damper. Finally, the effectiveness of MR damper in mitigating multi modes of cable vibration will be examined theoretically.

동일한 인접구조물의 효율적 진동제어방안 (Efficient Vibration Control Approach of Two Identical Adjacent Structures)

  • 옥승용
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.56-63
    • /
    • 2014
  • This study proposes a new control approach for efficient vibration suppression of two identical adjacent structures. The conventional control approach of two adjacent structures is to interconnect the two structures with passive, semi-active or active control devices. However, when the two adjacent structures are identical to each other, their dynamical behaviors such as frequency and damping properties are also the same. In this case, the interconnected control devices cannot exhibit the dissipative control forces on the both structures as expected since the relative displacements and velocities of the devices become close to zero. In other words, the interconnection method does not work for the twin structures as enough as expected. In order to solve this problem, we propose several new control approaches to effectively and efficiently reduce the identically-fluctuating responses of the adjacent structures with minimum control efforts. In order to demonstrate the proposed control systems, the proposed several control systems are optimally designed and their control performances are compared with that of the conventional optimal control system where each TMD(tuned mass damper) is installed in each structure for independent control purpose. The simulated results show that one of the proposed control systems(System 04) is able to guarantee enhanced control performance compared with the conventional system.

스카이훅 시스템에의 능동 서스펜션 제어 이론 적용에 관한 연구 (A Study on Adopting Active Suspension Control in Sky Hook System)

  • 박중현;장승재
    • 한국정보통신학회논문지
    • /
    • 제10권5호
    • /
    • pp.950-955
    • /
    • 2006
  • 본 논문에서는 스카이훅댐퍼 시스템의 해석 및 설계에 능동 서스펜션 제어 이론을 적용하여 현가장치설계에 응용 할 수 있는 이론 및 실험 적 제어장치 적용에 관한 연구를 수행하였다. 최근의 현가장치설계에서는 강성과 감쇠를 능동적으로 제어하는 기술의 적용이 일반화되고 있으며, 다른 차량안정성 제어장치와의 연계성이 높아짐에 따라, 제어 시스템설계에서 보다 내구성 이 강하고 제어효과의 응답성이 빠르며 정도 또한 높은 제어장치의 필요성이 요구되고 있다. 본 연구는 댐퍼의 위치관계에 따른 스카이훅시스템을 해석하여 위와 같은 빠른 응답성과 높은 정도의 제어가 가능한 제어시스템을 해석, 설계하기 위하여 강인제어시스템의 적용에 관한 고찰을 하였다. 그리고 제어대상시스템에 대한 강인제어시스템을 설계하기 위한 모델링 및 적용방법을 수식적으로 해석하였으며, 스카이훅현가장치의 제어시 스템설계에 중요한 내외란성 향상을 위한 강인제어시스템설계에 적용하는 방법에 관해 고찰하였다.

센서위치를 고려한 능동 서스펜션 강인제어에 관한 연구 (A Study on Active Suspension Robust Control with Sensor and Actuator Location)

  • 박중현;장승재
    • 한국정보통신학회논문지
    • /
    • 제10권6호
    • /
    • pp.1147-1152
    • /
    • 2006
  • 본 논문에서는 스카이훅댐퍼 시스템의 해석 및 설계에 능동 서스펜션 강인제어 이론을 적용하여 현가장치설계에 응용 할 수 있는 이론 및 실험적 제어 장치 적용에 관한 연구를 수행하였다. 최근의 현가장치설계에서는 강성과 감쇠를 능동적으로 제어하는 기술의 적용이 일반화되고 있으며, 다른 차량안정성제어장치와의 연계성이 높아짐에 따라, 제어시스템설계에서 보다 내구성이 강하고 제어효과의 응답성이 빠르며 정도 또한 높은 제어장치의 필요성이 요구되고 있다. 본 연구는 센서의 위치 관계에 따른 능동현가시스템을 해석하여 위와 같은 빠른 응답성과 높은 정도의 제어가 가능한 제어시스템을 해석, 설계하기 위하여 강인제어시스템의 적용에 관한 고찰을 하였다. 그리고 제어대상시스템에 대한 강인제어시스템을 설계하기 위한 모델링 및 적용방법을 수식적으로 해석하였으며, 스카이훅현가장치의 제어시스템설계에 중요한 내외란성 향상을 위한 강인제어 시스템설계에 적용하는 방법에 관해 고찰하였다.

승차감 향상을 위한 차체 상하.피칭 능동 현가제어에 관한 연구 (A Study on Active Suspension Control System in Vehicle Bouncing and Pitching Vibration for Improving Ride Comfort)

  • 박중현
    • 한국컴퓨터정보학회논문지
    • /
    • 제12권2호
    • /
    • pp.325-331
    • /
    • 2007
  • 본 논문에서는 능동 현가장치의 해석 및 설계에 강인제어 이론을 적용하여 현가장치설계에 응용 할 수 있는 이론 및 실험적 제어장치 적용에 관한 연구를 수행하였다. 최근의 현가장치설계에서는 강성과 감쇠를 능동적으로 제어하는 기술의 적용이 일반화 되고 있으며, 다른 여러 종류의 차량 안정성제어 장치와의 연계성이 높아짐에 따라, 제어 시스템설계에서 보다 내구성이 강하고 제어효과의 응답성이 빠르며 정도 또한 높은 제어장치의 필요성이 요구되고 있다. 본 연구는 전륜 및 후륜의 위치와 주행속도관계에 따른 능동현가시스템을 해석하여 위와 같은 빠른 응답성과 높은 정도의 제어가 가능한 제어시스템을 해석, 설계하기 위하여 능동 현가 제어시스템의 적용에 관한 고찰을 하였다. 그리고 제어대상시스템에 대한 능동 제어시스템을 설계하기위한 모델링 및 적용방법을 수식적으로 해석하였으며, 능동 현가장치의 제어시스템설계에 중요한 내외란성 향상을 위한 강인제어시스템설계에 적용하는 방법에 관해 고찰하였다.

  • PDF

능동 현가장치에의 지능형 제어시스템 적용에 관한 연구 (A Study on Adopting Intelligent Control System in Active Suspension Equipment)

  • 박중현
    • 한국컴퓨터정보학회논문지
    • /
    • 제12권3호
    • /
    • pp.287-293
    • /
    • 2007
  • 본 논문에서는 능동 현가장치의 해석 및 설계에 지능형 강인제어 이론을 적용하여 현가장치설계에 응용 할 수 있는 이론 및 실험적 제어장치 적용에 관한 연구를 수행하였다. 최근의 현가장치설계에서는 강성과 감쇠를 능동적으로 제어하는 기술의 적용이 일반화되고 있으며, 다른 차량안정성제어장치와의 연계성이 높아짐에 따라, 제어시스템설계에서 보다 내구성이 강하고 제어효과의 응답성이 빠르며 정도 또한 높은 제어장치의 필요성이 요구되고 있다. 본 연구는 전륜 및 후륜의 위치와 주행속도관계에 따른 능동현가시스템을 해석하여 위와 같은 빠른 응답성과 높은 정도의 제어가 가능한 제어시스템을 해석, 설계하기 위하여 지능형 제어시스템의 적용에 관한 고찰을 하였다. 그리고 제어대상시스템에 대한 지능형 제어시스템을 설계하기 위한 모델링 및 적용방법을 수식적으로 해석하였으며, 능동 현가장치의 제어시스템설계에 중요한 내외란성 향상을 위한 지능형 강인제어시스템설계에 적용하는 방법에 관해 고찰하였다.

  • PDF