• Title/Summary/Keyword: particle size analyzer

Search Result 359, Processing Time 0.027 seconds

Variations of Aerosol Size Distribution on Ambient Air (대기중 에어로졸 입경분포의 변화)

  • 김신도;안기석;김종호;김태식
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 1999.10a
    • /
    • pp.83-84
    • /
    • 1999
  • 시정악화나 광화학 스모그를 비롯하여 지구 온난화에 부유 입자상 물질이 미치는 영향 등을 파악하기 위해선 중량농도, 화학적 성분분석 등과 함께 그 입경별 크기 분포도 반드시 고려되어야만 한다. 입경분포 측정을 위하여 다단식 임팩터(Cascade Impactor)나 광학입자계수기(OPC, Optical Particle Counter), Aerosizer, SMPS (Scanning Mobility Particle Sizer), EAA(Electrical Aerosol Analyzer) 등 이주로 사용되고 있다.(중략)

  • PDF

Dispersion of Alloy 625 Nanoparticles in Ethanol

  • Lee, Eun-Hee;Lee, Min-Ku;Rhee, Chang-Kyu
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.673-674
    • /
    • 2006
  • The influence of several experimental parameters on the formation of stable Alloy 625 nanoparticles dispersion in ethanol was investigated. Several analyzing methods were applied, like transmission profiles measured by Turbiscan, transmission electron microscopy, X-ray diffraction, gas chromatography, and particle size analyzer. The correlation among the increase of particle sizes, caused by nanoparticle coalescence and collision, concentration of dispersant and time was presented and discussed. The optimum conditions for the formation of stable dispersion are evaluated.

  • PDF

Measurement of the Particle Current Changes Associated with the Flatness of Deflector Mesh Surface in Particle Beam Mass Spectrometer System

  • Kim, Dongbin;Kim, TaeWan;Jin, Yinhua;Mun, Jihun;Lim, In-Tae;Kim, Ju-Hwang;Kim, Taesung;Kang, Sang-Woo
    • Applied Science and Convergence Technology
    • /
    • v.25 no.2
    • /
    • pp.25-27
    • /
    • 2016
  • The surface flatness of metal meshes in a deflector of particle beam mass spectrometer (PBMS) required ideally flat, and this can specify the particle trajectories which goes through the detector. In this research, charged particle current was measured using the different surface roughness deflectors. NaCl particles were generated monodispersed in its size by using differential mobility analyzer and the whole processes were followed the way calibrating PBMS. The results indicate that the mesh surface morphology in the deflector can affect to the particle size and the concentration errors, and sensitivity of PBMS.

Phase Doppler Measurements and Probability Density Functions in Liquid Fuel Spray (연료분무의 위상도플러 측정과 확률밀도함수의 도출)

  • 구자예
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.4
    • /
    • pp.1039-1049
    • /
    • 1994
  • The intermitternt and transient fuel spray have been investigated from the simultaneous measurement of droplet sizes and velocities by using Phase/Doppler Particle Analyzer(PDPA). Measurement have been done on the spray axis and at the edge of the spray near nozzle at various gas-to-liquid density ratios(.rho./sub g//.rho./sub l/) that ranges from those found in free atmospheric jets to conditions typical of diesel engines. Probability density distributions of the droplet size and velocity were obtained from raw data and mathematical probability density functions which can fit the experimental distribations were extracted using the principle of maximum likelihood. In the near nozzle region on the spray axis, droplet sizes ranged from the lower limit of the measurement system to the order of nozzle diameter for all (.rho./sub g/ /.rho./sub l/) and droplet sizes tended to be small on the spray edge. At the edge of spray, average droplet velocity peaked during needle opening and needle closing. The rms intensity is greatly incresed as the radial distance from the nozzle is increased. The probability density function which can best fit the physical breakage process such as breakup of fuel drops is exponecially decreasing log-hypebolic function with 4 parameters.

A Study of Two-Phase Swirl Spray Characteristics on Dual Airblast Velocity Ratio (이중공기공급 속도비에 따른 이류체 선회분무 특성 연구)

  • Kang, S.J.;Oh, J.H.;Song, K.J.;Rho, B.J.
    • Journal of ILASS-Korea
    • /
    • v.5 no.3
    • /
    • pp.27-36
    • /
    • 2000
  • In this study, spray characteristics of a dual airblast atomizer are addressed. Three dimensional characteristics of a dual airblast atomizer with air swirl are measured to provide the significant data. The liquid flow rate was fixed at 0.06 kg/min, and atomizing air was controlled at the liquid-air mass ratio of 4.0. The performance of the spray with co-swirl and counter-swirl flow was investigated at each point in the developed spray region using a three-component phase Doppler particle analyzer. This instrument was also used to evaluate the concentration profiles. The three dimensional mean velocity were investigated of present flow characteristics of the dual airblast atomizer. In addition, drop size distributions, mean droplet size profile, and droplet concentration were analyzed to understand atomization characteristics. This experimental results can be conveniently utilized for the preliminary design of gas turbine engines for aircraft.

  • PDF

Effects of Plasma on the Surface of Protein Chip Plates (단백질 칩 기판의 플라즈마 효과)

  • Hyun, J.W.;Kim, N.Y.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.549-554
    • /
    • 2008
  • Nickel Chloride coated protein chip plates were developed by using a spin coating method after $H_2$ plasma treatment. The adsorption ability of histidine tagged protein was investigated at various times of plasma treatment. The properties of the nickel chloride and protein on the surface of the slides were assayed using particle size analysis and the extent of the protein adsorption was determined by using a bio imaging analyzer system. The results show that the ability of protein adsorption decreased as increasing the time of $H_2$ plasma treatment. The mechanism on the ability of protein adsorption at the plate surface is discussed on results and discussions. The results also suggest that the surface stabilization of protein chip plates treated by plasma technology may be applicable in biosensor markets.

Characterization of (La,Sr))$MnO_3/Gd_{0.2}Ce_{0.8}O_{1.9}$ Interface with Citric Acid Contents and Sintering Temperature (시트르산의 양과 소결온도에 따른 (La,Sr)$MnO_3/Gd_{0.2}Ce_{0.8}O_{1.9}$ 계면특성)

  • 윤일영;윤희성;김병호
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.11 no.1
    • /
    • pp.18-25
    • /
    • 1998
  • G $d_{0.2}$C $e_{0.8}$ $O_{1.9}$(CGO) for electrolyte and L $a_{0.5}$S $r_{0.5}$Mn $O_3$(LSM50) for cathode in Solid Oxide Fuel Cells(SOFC) were synthesized by citrate process. Specimens were prepared with sintering temperatures at 110$0^{\circ}C$, 120$0^{\circ}C$ and 130$0^{\circ}C$, which were fabricated by slurry coating with citric acid contents. Interfacial resistance was measured between cathode and electrolyte using AC-impedance analyzer. With various citric acid content, the degree of agglomeration for the initial particles changed. Also sintering temperature changed the particle size and the degree of densification of cathode. Factors affecting the interfacial resistance were adherent degree of the electrolyte and cathode, distribution of TPB(three phase boundaries, TPB i.e., electrolyte/electrode/gas phase area) and porosity of cathode. By increasing the sintering temperature, particle size and densification of the cathode were increased. And then, TPB area which occurs catalytic reaction was reduced and so interfacial resistance was increased.sed.sed.d.

  • PDF

Chemical Constitution, Morphological Characteristics, and Biological Properties of ProRoot Mineral Trioxide Aggregate and Ortho Mineral Trioxide Aggregate

  • Kum, Kee Yeon;Yoo, Yeon Jee;Chang, Seok Woo
    • Journal of Korean Dental Science
    • /
    • v.6 no.2
    • /
    • pp.41-49
    • /
    • 2013
  • Purpose: This study sought to compare the elemental constitution, morphological characteristics, particle size distribution, biocompatibility, and mineralization potential of Ortho MTA (OMTA) and ProRoot MTA (PMTA). Materials and Methods: OMTA and PMTA were compared using energy-dispersive spectrometry, particle size analysis, and scanning electron microscopy. The biocompatibility and mineralization-related gene expression (osteonectin and osteopontin) of both MTAs were also compared using methylthiazol tetrazolium assay and reverse transcription-polymerization chain reaction analysis, respectively. The results were analyzed by Kruskal-Wallis test with Bonferroni correction. P-value of <0.05 was considered significant. Result: The morphology of OMTA powders was similar to that of PMTA. The constituent elements of both MTAs were calcium, silicon, and aluminum. The mean particle sizes of OMTA and PMTA were 4.60 and 3.34 mm, respectively. Both MTAs had equally favorable in vitro biocompatibility and affected the messenger RNA expression of osteonectin and osteopontin. Conclusion: Within the limitations of this study, OMTA could be a promising biomaterial in clinical endodontics.

A Study on Evaluation for Sampling and Analytical Methods of Diatomaceous Earth Dust (규조토 분진 측정 및 분석 방법의 비교에 관한 연구)

  • Lim, Hyun Sul;Kim, Ji Yong;Cheong, Hoe Kyeong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.5 no.2
    • /
    • pp.212-225
    • /
    • 1995
  • This study was performed in a diatomite factory located at Pohang City, Kyeongsangbuk-Do. The major objectives were to evaluate sampling and analytical methods of diatomaceous earth dust. Concentrations of total and respirable diatomaceous earth dust were measured. Size distribution of dust was analyzed by a personal cascade impactor and the particle size analyzer which is an application of multiple diffraction method. Also crystalline silica in respirable and total dust samples was analyzed quantitatively by X-ray diffraction and Fourie Transform Infrared Spectroscopy(FTIR). The results were as follows: The airborne total and respirable dust concentrations, particle size distribution, and cristalline silica(quartz) concentrations showed approximately a log-normal distribution. The means of totaldust concentrations at flour maufacturing, fire brick grinding and packaging processes exceeded the Korean and American Conference of Governmental Industrial Hygienists standards, $10mg/m^3$. The size distribution of diatomaceous earth dust was log-normal and identified as the rspirable particle mass and thoracic particle mass. The crystalline silica in respirable and total dust samples was identified to quartz and contained about 10 % in those samples. Finally, it is necessary to study the applicability of multiple diffraction for particle size distribution to compare the ACGIH's size selective sampling with other materials containing crystalline silica. Also, advanced quantitative study to X-ray diffraction and FTIR methods shoud be carried out 10 verify general and specific characteristics for respirable crystalline silica.

  • PDF