• Title/Summary/Keyword: particle removal efficiency

Search Result 348, Processing Time 0.025 seconds

A study on the removal of particulate matters using unidirectional flushing (단방향 플러싱에 의한 입자성 물질의 제거에 관한 연구)

  • Kim, Dooil;Cheon, Subin;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.371-380
    • /
    • 2015
  • Particulate matters in a water distribution system are main causes of turbidity and discoloration of tap water. They could be removed by conventional or uni-directional flushing in a water distribution system. The behaviors and required flow velocity of particles are not well known for their flushing. A model water main and hydrant were made from transparent acrylic pipe of 30mm and 16mm in diameter, respectively. We analyzed the effect of flushing velocity, particle density, and particle diameter. We found that the existence of break-though velocities at which particles begin to be removed, and which are affected by their physical properties. The removal efficiencies seemed to be influenced by resuspension capabilities related to their upward movement from the bottom. Heavy particles like scale were hard to remove through upflow hydrant because the falling velocity, calculated using Stokes' law, was higher. Particle removal efficiencies of upward hydrant and downward drain showed minor differences. Additionally, the length between hydrant and control valve affected flushing efficiency because the particulate matters were trapped in this space by inertia and recirculating flow.

Development of Tungsten CMP (Chemical Mechanical Planarization) Slurry using New Abrasive Particle (새로운 연마입자를 이용한 텅스텐 슬러리 개발)

  • Yu, Young-Sam;Kang, Young-Jae;Kim, In-Kwon;Hong, Yi-Koan;Park, Jin-Goo;Jung, Seok-Jo;Byun, Jung-Hwan;Kim, Moon-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.571-572
    • /
    • 2006
  • Tungsten CMP needs interconnect of semiconductor device ULSI chip and metal plug formation, CMP technology is essential indispensable method for local planarization. This Slurry development also for tungsten CMP is important, slurry of metal wiring material that is used present is depending real condition abroad. It is target that this research makes slurry of efficiency that overmatch slurry that is such than existing because focus and use colloidal silica by abrasive particle to internal production technology development. Compared selectivity of slurry that is developed with competitor slurry using 8" tungsten wafer and 8" oxide wafer in this experiment. And removal rate measures about density change of $H_2O_2$ and Fe particle. Also, corrosion potential and current density measure about Fe ion and Fe particle. As a result, selectivity find 83:1, and expressed similar removal rate and corrosion potential and current density value comparing with competitor slurry.

  • PDF

Performance Prediction of a Grease Filter for Kitchen Ventilation (주방환기용 그리스 필터의 성능예측)

  • Kim Ki-Jung;Bae Gwi-Nam;Kim Youngil;Hur Nahmkeon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.313-316
    • /
    • 2002
  • A grease filter is used to remove grease generated from a cooking appliance in a kitchen. This numerical study has been conducted to investigate the particle collection characteristics of a grease filter having nominal flowrate of $100m^{3}/h$. The flow field and particle trajectories in the grease filter with a flow chamber were simulated by using the commercial code of STAR-CD. The pressure drop of a grease filter rapidly increases with increasing the air flowrate. The numerical values of the pressure drop are slightly lower than the experimental values when the air flowrates are 50, 75, and $100m^{3}/h$. The particle collection efficiency of a grease filter increases with increasing the particle diameter and the air flowrate, which means that the inertial impaction is a dominant particle removal mechanism in a grease filter The cut-off diameter of the tested grease filter representing $50-{\%}$ collection efficiency is about $11.6{\mu}m$ for water droplets at $100m^{3}/h$.

  • PDF

Optimal Operating Condition of Vortex Separator for Combined Sewer Overflows Treatment (합류식 하수관거 월류수 처리를 위한 와류형 분리장치의 최적 운전조건)

  • Han, Jung-kyun;Joo, Jae-young;Lee, Bum-joon;Na, Ji-hun;Park, Chul-hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.557-564
    • /
    • 2009
  • A combined sewer system can quickly drain both storm water and sewage, improve the living environment and resolve flood measures. A combined sewer system is much superior to separate sewer system in reduction of the non-point source pollutant load. However, during rainfall. it is impossible in time, space and economic terms to cope with the entire volume of storm water. A sewage system that exceeds the capacity of the sewer facilities drain into the river mixed with storm-water. In addition, high concentration of CSOs by first-flush increase pollution load and reduce treatment efficiency in sewage treatment plant. The aim of this study was to develope a processing unit for the removal of high CSOs concentrations in relation to water quality during rainfall events in a combined sewer. The most suitable operational design for processing facilities under various conditions was also determined. With a designed discharge of 19.89 m/min, the removal efficiency was good, without excessive overflow, but it was less effective in relation to underflow, and decreased with decreasing particle size and specific gravity. It was necessary to lessen radius of vortex separator for increasing inlet velocity in optimum range for efficient performance, and removal efficiency was considered to high because of rotation increases through enlargement of comparing height of vortex separator in diameter. By distribution of influent particle size, the actual turbulent flow and experimental results was a little different from the theoretical removal efficiency due to turbulent effect in device.

Reaction of Natural Manganese Dioxide with Hydrogen Sulfide at High-Temperature (고온에서 천연산 망간광석과 황화수소의 반응특성)

  • Shon, Byung-Hyun;Oh, Kwang-Joong;Kim, Young-Sick
    • Clean Technology
    • /
    • v.2 no.1
    • /
    • pp.69-79
    • /
    • 1996
  • Sulfur emission control in coal gasification plants implies the removal of $H_2S$ from the fuel gas in the gas clean-up system. In this study, the effects of particle size of sorbents, temperature of sulfidation and sorbent characteristics on the $H_2S$ removal efficiency of manganese ore were investigated. Experimental results showed that the removal efficiency of $H_2S$ was optimum when the temperature was about $700^{\circ}C$. And that the smaller particle size, the higher the $H_2S$ removal efficiency, but that was not effective very much. As the temperature increases, the reactivity of sorbents has lowered because agglomeration of sorbents increased the intraparticle transport resistance. This phenomenon was confirmed by SEM photographs. The equilibrium ratio ($P_{H_2O}/P_{H_2S}$) obtained by experiments is represented as a ${\log}(P_{H_2O}/P_{H_2S})=5653/T-3.7909$. It was showed that the natural manganese ore could be used as a sorbent because its capacity for $H_2S$ removal is equivalent to the eariler developed sorbents.

  • PDF

Performance Analysis of a Hydrodynamic Separator for Treating Particulate Pollutants in Highway Rainfall Runoff

  • Yu, Jianghua;Yi, Qitao;Kim, Young-Chul
    • Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.262-269
    • /
    • 2009
  • This study examined the separation characteristics of particles in the rainfall runoff from paved roads using a ${\varphi}7.5$ cm hydrocyclone. The volume fraction and total suspended solids concentrations in the overflow and underflow from the hydrocyclone, as well as the separation efficiency were determined. The results indicated that the overflow volume increased with increasing operational pressure, but decreased with decreasing ratio of underflow outlet to inlet sizes ($D_u/D_i$), while the underflow to overflow volumes showed contrary behavior. The total suspended solid (TSS) concentration ratio between the overflow and inflow ($TSS_{over/in}$) decreased as a function of the operational pressure, while the corresponding ratio of underflow to inflow ($TSS_{under/in}$) increased. There was no visible difference in the $TSS_{over/in}$ with increasing $D_u/D_i$ ratio, but the $TSS_{under/in}$ decreased sharply. The particle removal efficiency was mainly affected by the particle size.

Numerical Study on the Flow Characteristics of Uniflow Cyclone (단방향 사이클론의 유동 특성에 관한 수치해석적 연구)

  • Yan, Zheng-Qi;Zhang, Shuo;Shin, Weon Gyu
    • Journal of the Korean Society of Visualization
    • /
    • v.18 no.3
    • /
    • pp.77-83
    • /
    • 2020
  • A uniflow cyclone has simple structure with a single channel in one direction. The one directional particle removal enables the uniflow cyclone to have compact size and low pressure drop. However, it has low collection efficiency compared to conventional cyclones. In this study, the effect of primary geometry on the performance of a uniflow cyclone with swirl vane is numerically investigated for the design of high performance uniflow cyclone. It is found that as the vortex finder diameter is increased, the pressure drop and the collection efficiency are decreased. Also, the same trend is predicted when the vortex finder height is increased. The best collection efficiency is predicted to be obtained when the vortex finder height is equal to the diameter of a cyclone. Reducing the body height by half will increase the pressure drop by 41%. When the body height is decreased, the collection efficiency is first increased and then decreased. The best collection efficiency is obtained when the body height is 4~5 times the cyclone diameter. Overall, the particle collection efficiency is highest when the Dν/D is equal to 0.3. But, the pressure drop is as high as 1592 Pa. Considering both collection efficiency and pressure drop, the best design is when Dν/D, Hν/D, and Hb/D are equal to 0.5, 1, and 5, respectively.

A Study on Treatment of CSOs by Vortex Separator and Continuous Fiber-Filter System (Vortex separator와 연속식 섬유사여과를 이용한 CSOs 처리연구)

  • Lee, Bum-Joon;Na, Ji-Hoon;Kim, Jin-Sung;Joo, Jae-Young;Bae, Yoon-Sun;Jung, In-Ho;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.4
    • /
    • pp.443-451
    • /
    • 2010
  • This study was conducted to confirm the CSOs characteristics, and to estimate treatment efficiency of CSO treatment process. Flowrate was average $53,500m^3$/d, maximum $58,100m^3$/d during dry season, but after rain-fall, the flowrate was increased more than twice that of the dry season. And, water pollution concentrations, such as $COD_{Cr}$, SS, $BOD_5$, TN and TP of after rain-fall, were also increased. Thus, for more efficient treatment of pollutants during rainy season, The vortex separator and continuous fiber filter devices were used. From the results on particle range, removal efficiency of particle was 99.7% at the particle size range of $40{\sim}100{\mu}m$ but decreased as 55-80% at the below $40{\mu}m$. The removal efficiencies of $COD_{Cr}$, SS, TN and TP were approx. 70, 60, 70 and 50, respectively during the dry season and approx. 50, 50, 8 and 18% during the rainy season. Also, when compared with the primary sediment basin, $COD_{Cr}$, SS, TN and TP removal efficiencies were high. especially, at the case of TN and TP, TN was more removed than TP because of higher conversion factor value. But we needed more study for the injection of a coagulants to get more stable treatment efficiency for soluble pollutants. Consequently, This process can be used for CSOs treatment as well as replace the primary sedimentation basin during the dry season.

Application of Gas to Particle Conversion Reaction to increase the DeSOx/DeNOx Efficiency under Pulsed Corona Discharge (DeSOx/DeNOx 효율 개선을 위한 펄스 코로나 방전하에서 기체미립자 전환반응의 적용)

  • Choi, Yu-ri;Kim, Dong-Joo;Kim, Kyo-Seon
    • Journal of Industrial Technology
    • /
    • v.18
    • /
    • pp.249-258
    • /
    • 1998
  • In this paper, we investigated the post-combustion removal of nitrogen oxide($NO_x$) and sulfur oxide($SO_x$) which is based on the gas to particle conversion process by the pulsed corona discharge. Under normal pressure, the pulsed corona discharge produces the energetic free electrons which dissociate gas molecules to form the active radicals. These radicals cause the chemical reactions that convert $SO_x$ and $NO_x$ into acid mists and these mists react with $NH_3$ to form solid particles. Those particles can be removed from the gas stream by conventional devices such as electrostatic precipitator or bag filter. The reactor geometry was coaxial with an inner wire discharge electrode and an outer ground electrode wrapped on a glass tube. The simulated flue gas with $SO_x$ and $NO_x$ was used in the experiment. The corona discharge reactor was more efficient in removing $SO_x$ and $NO_x$ by adding $NH_3$ and $H_2O$ in the gas stream. We also measured the removal efficiency of $SO_x$ and $NO_x$ in a cylinder type corona discharge reactor and obtained more than 90 % of removal efficiency in these experimental conditions. The effects of process variables such as the inlet concentrations of $SO_x$, $NH_3$ and $H_2O$, residence time, pulse frequencies and applied voltages were investigated.

  • PDF

A Study on the Adsorption Effect of Korean zeolite "Clinoptilolite" as Cigarette Cavity Filter Additive. (한국산 Zeolite의 필터첨가제로서의 흡착효과에 관하여)

  • Yang, Gwang-Gyu;Song, Chi-Hyeon;Kim, Chan-Ho
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.2 no.1
    • /
    • pp.8-16
    • /
    • 1980
  • The cavity of triple filter was filled with the mixture of clinoptilolite and charcoal(1:1, V/V). The particle size of clinoptilolite was 30$\pm$5 A.S.T.M mesh. The reduction effects of the important gaseous components by this mixture were obtained as follows: 1) In comparison with the normal cellulose acetate niter, the contents of nicotine and T.P.M. were reduced about 35% and 22% respectively. 2) Many aliphatic and cyclic compounds were also substantially reduced in an average of 60%. 3) In contrast with the charcoal, the removal efficiency of clinoptilolite was revealed as higher (15-20%) in case of aliphatic compounds than the one (10-15%) of cyclic compounds. The above results showed us that the removal function of gaseous components was quite complementary each other (charcoal and clinoptilolite).

  • PDF