• Title/Summary/Keyword: partial heating

Search Result 154, Processing Time 0.029 seconds

Screening of Lactobacilli Derived from Fermented Foods and Partial Characterization of Lactobacillus casei OSY-LB6A for Its Antibacterial Activity against Foodborne Pathogens

  • Chung, Hyun-Jung;Yousef, Ahmed E.
    • Preventive Nutrition and Food Science
    • /
    • v.14 no.2
    • /
    • pp.162-167
    • /
    • 2009
  • Various fermented foods were screened in search of food-grade bacteria that produce bacteriocins active against Gram-negative pathogens. An isolate from a mold-ripened cheese presented antibacterial activity against Gram-positive and Gram-negative bacteria. The most active isolate was identified as Lactobacillus casei by a biochemical method, ribotyping, and membrane lipid analysis, and was designated as OSY-LB6A. The cell extracts of the isolate showed inhibition against Escherichia coli p220, E. coli O157, Salmonella enerica serovar Enteritidis, Salmonella Typhimurium, and Listeria monocytogenes. The antibacterial nature of the cell extract from the isolate was confirmed by eliminating the inhibitory effects of acid, hydrogen peroxide, and lytic bacteriophages. The culture supernatant and cell extract retained antibacterial activity after heating at $60{\sim}100^{\circ}C$ for $10{\sim}20$ min. The activity of the cell extract from Lb. casei was eliminated by pronase and lipase. Finally, the cell extract showed a bactericidal mode of action against E. coli in phosphate buffer solution, but it was bacteriostatic in broth medium and food extracts.

Thermal Performance of a Heat Sink According to Insulated Gate Bipolar Transistor Array and Installation Location (IGBT 배열과 설치 위치에 따른 히트 싱크 방열 성능)

  • Park, Seung-Jae;Yoon, Youngchan;Lee, Tae-Hee;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.30 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Thermal performance of a heat sink for an inverter power stack was analyzed in terms of array and installation location of an Insulated Gate Bipolar Transistor (IGBT). Thermal flow around the heat sink was calculated with a numerical model that could simulate forced convection. Thermal performance was calculated depending on the array and location of high- and low-power IGBTs considering the maximum temperature of IGBT. The optimum array and installation location were found and causes were analyzed based on results of numerical analysis. For the numerical analysis, experiment design considered the installation location of IGBT, ratio of heat generation rates of high- and low-power IGBTs, and velocity of the inlet air as design variables. Based on numerical results, a correlation that could calculate thermal performance of the heat sink was suggested and the maximum temperature of the IGBT could be predicted depending on the installation method.

Preparation of Bismuth Thin Films by RF Magnetron Sputtering and Study on Their Electrical Transport Properties (RF 마그네트론 스퍼터링을 이용한 Bismuth 박막의 제조와 그 전기적 특성 연구)

  • Kim Dong-Ho;Lee Gun-Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.38 no.1
    • /
    • pp.7-13
    • /
    • 2005
  • Bismuth thin films were prepared on glass substrate with RF magnetron sputtering and effects of substrate temperature on surface morphology and their electrical transport properties were investigated. Grain growth of bismuth after nucleation and the onset of coalescense of grains at 393 K were observed with field emission secondary electron microscopy. Continuous thin films could not be obtained above 473 K because of grain segregation and island formation. Hall effect measurements showed that substrate heating yields the decrease of carrier density and the increase of mobility. Resistivity of bismuth film has its minimum (about 0.7 x 10/sup -3/ Ωcm) in range of 403~433 K. Annealing of bismuth films deposited at room temperature was carried out in a radiation furnace with flowing hydrogen gas. The change of resistivity was not significant due to cancellation of the decrease of carrier density and the increase of mobility. The abrupt change of electrical properties of film annealed above 523 K was found to be caused by partial oxidation of bismuth layer in x-ray diffraction analysis.

Temperature Rise Analysis of Sliding Contact Surfaces in Lubrication Considering Elastic Deformation (탄성변형을 고려한 윤활 상태에서 거친 표면의 미끄럼 접촉온도 해석)

  • Cho Yong-Joo;Kim Byoung-Sun;Lee Sang-Don
    • Tribology and Lubricants
    • /
    • v.22 no.3
    • /
    • pp.137-143
    • /
    • 2006
  • The sliding contact interface of machine components such as bearings, gears frequently operates in lubrication at the inception of sliding failure under high loads, speed and slip. The surface temperature at the interface of bodies in a sliding contact is one of the most important factors influencing the behavior of machine components. Most surface failure in sliding contact region result from frictional heat generation. However, it is difficult to measure temperature rise experimentally. So the calculation of the surface temperature at a sliding contact interface has long been an interesting and important subject for tribologist. The surface temperature rise is related in contact pressure, sliding speed, material properties and lubrication thickness. Though roughness, load, ect all of the condition, are same, film thickness varies with velocity. In this study, surface temperature rise due to frictional heating in lubrication is calculated with various velocities. Surface film shearing and dry solid asperity contact are used to simulate the change of frictional heat in lubricated contact

Surgical Treatment of Cervical Salivary Mucocele in a Pit Bull Terrier (피쁠견에서 경추타액점액류의 외과적치료)

  • 정순욱;정월순;박수현
    • Journal of Veterinary Clinics
    • /
    • v.16 no.1
    • /
    • pp.210-213
    • /
    • 1999
  • A 15 months old male pit bull terrier was shown submandibular swelling, which was extended from left submandibular area through mandibular symphysis to right submandibular area and toward around left neck. In history taking, recurrence of swelling was recorded after conservative surgical incision, drainage and dressing. Palpation revealed no pain and heating, partial flutuation and hardness. By paracentesis, it was showed blood-tinged tenacious exudate without bad-smelling. Left submandibular salivary gland was able to be movable freely and the size decreased to half of that of right submandibular salivary gland. It was diagnosed as cervical salivary mucocele. In operation, rostral portion of left sublingual salivary gland was observed to be damaged transversely, showed black color and leaked saliva. Submandibular gland and rostral portion of sublingual salivary gland were resected, after ligation of ducts of submandibular and sublingual salivary glands. At 15 days postoperation, serosanguineous exudate from operation wound was dramatically decreased and stable granulation tissue mass at this area was first palpated. At 39 days after operation, outline of left and right mandibular was appeared normal and skin tenderness of mandibular area was equal to that of the other body wall.

  • PDF

Heterotrophic Bacterial Growth on Hoses in a Neonatal Water Distribution System

  • Buffet-Bataillon, Sylvie;Bonnaure-Mallet, Martine;De La Pintiere, Armelle;Defawe, Guy;Gautier-Lerestif, Anne Lise;Fauveau, Severine;Minet, Jacques
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.4
    • /
    • pp.779-781
    • /
    • 2010
  • After preliminary tests indicated an increased number of heterotrophic bacteria, we investigated possible sources of contamination in a neonatal intensive care unit (NICU) water distribution system. Scanning electron microscopic examination of flexible metallic hoses associated with the system revealed the presence of a biofilm; partial 16S rDNA sequencing revealed that the biofilm contained Blastomonas natatoria. Purgation of the water system three times a day, reinforced faucet cleaning, decreasing the cold water temperature to $12^{\circ}C$, and six repeated chlorinations at concentrations as high as 2 mg/l were not sufficient to eradicate the bacterial contamination. Replacing all of the rubber-interior flexible metallic hoses with teflon-lined hoses, followed by heating the water to $70^{\circ}C$, successfully controlled the bacteria.

Effects of Phosphorus and in-situ Post-heat Pulse Conditions on Resistance Spot Weldability of High Si DP980 Steel Sheet (고Si DP980강 스폿 용접 특성에 미치는 Phosphorus (P) 및 in-situ 후열처리 펄스 조건의 영향)

  • Choi, Du-Youl
    • Journal of Welding and Joining
    • /
    • v.33 no.6
    • /
    • pp.21-26
    • /
    • 2015
  • Recently, application of UHSS(Ultra High Strength Steels) whose tensile strength is over 1000MPa to car body structure are growing due to great needs for light weighting and improved crash worthiness. However, their poor weldability is one of obstacles to expand selecting to car body. In this study, effect of Phosphorus contents on resistance spot weldability of high elongation DP980 steel whose Si content is over 1% was investigated. The cross tension strength (CTS) was decreased showing partial interface fracture as Phosphorus content increase because of solidification segregation of Phosphorus. In order to improve resistance spot weldability by modification of welding condition, in-situ post-weld heating pulse was introduced after main pulse. The optimum cooling time between main and post pulse and post-pulse current condtion were determined through FEM welding simulation and DOE tests. The CTS was increased about 1.5 time showing plug fracture. The decrease of Phosphorus segregation was found to be a major reason for weld ductility and CTS improvement.

The Thermal conductivity analysis on the pavement applying geothermal snow melting system (지열 융설시스템을 적용한 포장체에서의 열전도 분석)

  • Lee, Seok-Jin;Kim, Bong-Chan;Seo, Un-Jong;Lee, Seung-Ha;Lee, Joo-Ho
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.03a
    • /
    • pp.221-228
    • /
    • 2010
  • A sliding accident on the road have a high percentage by road freezing, especially, it is often appeared at bridges and Tunnel of freezing areas. Thus, the stability of road operations is enhanced by preventing a partial freezing phenomenon. According to the geothermal snow melting system analysis, a pattern of thermal conductivity is found out about pavement materials of concrete and asphalt when it is buried. The thermal conductivity study is essential that be applied the geothermal snow melting system according to heating exchanger pipe laying of lower pavements. The model tests are conducted on low temperature in freezer using the manufactured test model which is equal to pavement materials. And Many variables are discovered from numerical analyzes of the same conditions with model test.

  • PDF

Construction History of the Old House "IMCHEONGGAK" in Andong and Estimation of its Original Structure -Focused on the 'Inner chamber' and the 'Sarang section'- (안동 "임청각(臨淸閣)"의 건축 이력과 원형 가구(架構) 추정 -사랑채와 안채를 중심으로-)

  • Lee, Jong-Seo
    • Journal of architectural history
    • /
    • v.25 no.2
    • /
    • pp.31-44
    • /
    • 2016
  • Imcheong-gak[臨淸閣] was a familial residence constructed in the early half of the Joseon dynasty period. It was partially destroyed by a fire during the 1590s war[壬辰倭亂] with the Japanese, and another fire that was caused between 1631 and 1634. The inner chamber[An-chae] and the Sarang section[Sarang-chae] today is the result of a partial reconstruction that took place back in 1626 and again around 1634. The residence also went through some changes because the new Ondol[溫突] heating system had to be applied to the structure. Based upon sections that remain in their original forms, we can presume that the Imcheong-gak residence originally had an inner chamber which was composed of the following elements: A main structure which was built upon a foundation featuring a Matbae[맞배] roof, two "Ik'rang[翼廊, flank]" sections on the East and West sides of the inner chamber, and a "Haeng'rang[行廊, passage]" structure on the opposite side of the main structure. Unlike the main structure, other portions of the inner chamber were all built directly upon the ground, and showed multiple stories, with Matbae roofs of their own. We can also assume that the Sarang section in the south would have been a pre-Ondol[溫突] bedroom, with a Board platform[板房] and a Gomi-ceiling[Gomi-banza] fashion.

A study on the Analysis of Combustion Gas and its Flow Induced by Fire in an Enclosure (밀폐공간내 화재에 의해 생성된 연소가스 분석 및 유동에 관한 연구)

  • 추병길;조성곤
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.1
    • /
    • pp.77-93
    • /
    • 1997
  • The natural convection and combined heat transfer induced by fire in a rectangular enclosure is numerically studied. The model for this numerical analysis is partially opened, it is divided by a vertical baffle projecting from ceiling. The solution procedure Includes the standard k- $\varepsilon$ model for turbulent flow and the discrete ordinates method (DOM ) is used for the calculation of radiative heat transfer equation. In this study, numerical simulation on the combined naturnal convection and radiation is carried out in a partial enclosure filled with absorbed-emitted gray media, but is not considered scattering problem. The velocity vectors, streamlines, and isothermal lines are compared the results of pure convection with those of the combined convection-radiation, the combined heat transfer. Comparing the results of pure convection with those of the combined convection-radiation, the combined heat transfer analysis shows the stronger circulation than those of the pure convection. Three different locations of heat source are considered to observe the effect of heat source location on the heat transfer phenomena. As the results, the circulation and the heat transfer In the left region from heating block are much more influenced than those in the right region. It is also founded that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF