Partial Discharge Pattern Recognition of Cast Resin Current Transformers Using Radial Basis Function Neural Network

  • Chang, Wen-Yeau
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권1호
    • /
    • pp.293-300
    • /
    • 2014
  • This paper proposes a novel pattern recognition approach based on the radial basis function (RBF) neural network for identifying insulation defects of high-voltage electrical apparatus arising from partial discharge (PD). Pattern recognition of PD is used for identifying defects causing the PD, such as internal discharge, external discharge, corona, etc. This information is vital for estimating the harmfulness of the discharge in the insulation. Since an insulation defect, such as one resulting from PD, would have a corresponding particular pattern, pattern recognition of PD is significant means to discriminate insulation conditions of high-voltage electrical apparatus. To verify the proposed approach, experiments were conducted to demonstrate the field-test PD pattern recognition of cast resin current transformer (CRCT) models. These tests used artificial defects created in order to produce the common PD activities of CRCTs by using feature vectors of field-test PD patterns. The significant features are extracted by using nonlinear principal component analysis (NLPCA) method. The experimental data are found to be in close agreement with the recognized data. The test results show that the proposed approach is efficient and reliable.

수력 발전기 권선에서의 운전중 부분방전 측정기법 (On-line partial discharge measurement techniques of hydro-generator windings)

  • 황동하;김진봉;김용주;박명수;김택수
    • 대한전기학회논문지
    • /
    • 제45권2호
    • /
    • pp.294-300
    • /
    • 1996
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the endwinding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current and .DELTA.tan.delta. tests has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot dischages may not be found with off-line diagnoses. This paper introduces the on-line partial discharge measurement techniques using frequency spectrum analyzer(FSA) for the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF

전차선로용 폴리머 피뢰기(42kV 10kA Class3)의 전기적 특성 및 누설전류 특성 평가 (Evaluation of Electrical and Leakage Current Characteristics of Polymer Arrester(42kV 10kA Class3) for Railroad Line)

  • 김석수;최익순;박춘현;조이곤;박태곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.2
    • /
    • pp.1171-1174
    • /
    • 2004
  • Leakage current of the polymer arrester(42kV, 10kA, Class3) for railroad line applied actually field was observed and electrical characteristics of arrester before and after applied actually field were investigated. During applied actually field, leakage current of arresters were $610{\sim}647{\mu}A$ in AN SAN line and $500{\mu}A$ in YUNG DONG line. After applied actually field, electrical characteristics of arrester, such as insulation test, reference voltage test, leakage current test and partial discharge current test, wasn't variation as before applied actually field.

  • PDF

Partial Discharge Characteristics in LLDPE-Natural Rubber Blends: Correlating Electrical Quantities with Surface Degradation

  • Aulia, Aulia;Ahmad, Mohd Hafizi;Abdul-Malek, Zulkurnain;Arief, Yanuar Z.;Lau, KwanYiew;Novizon, Novizon
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권3호
    • /
    • pp.699-706
    • /
    • 2016
  • Partial discharges (PD) lead to the degradation of high voltage cables and accessories. PD activities occur due to the existence of impurities, voids, contaminants, defects and protrusions during the manufacture and installation of power cables. Commonly, insulation failures occur at cable joints and terminations, caused by inhomogeneous electric field distributions. In this work, a blend of natural rubber (NR) and linear low density polyethylene (LLDPE) was investigated, and the optimal formulation of the blend that could resist PD was discussed. The experiments were conducted under a constant high voltage stress test of 6.5 kV AC and the magnitude of partial discharge activities was recorded using the CIGRE method II. Pattern analysis of PD signals was performed along with the interpretation of morphological changes. The results showed that the addition of 10 wt% of NR and 5 wt% of Alumina Trihydrate (ATH) provided promising results in resisting PD activities. However, as the NR content increased, more micropores existed, thus resulting in increased PD activities within the samples.

대용량 발전기 고정자 권선의 절연열화 특성 (Characteristics of Insulation Aging in Large Generator Stator Windings)

  • 김희동;이영준;주영호
    • 전기학회논문지
    • /
    • 제58권7호
    • /
    • pp.1375-1379
    • /
    • 2009
  • Insulation tests have been performed on two generator stator bars under accelerated aging under a laboratory environment. Electrical stress was applied to stator bar No.1, and electrical and thermal stresses were applied to stator bar No.2. Nondestructive stator insulation tests including the ac current, dissipation factor($tan{\delta}$), and partial discharge tests have been performed on both bars as the bars were aged for 11460 hours. Experimental test results show that ${\Delta}I$, ${\Delta}tan{\delta}$, and partial discharge of No. 1 and No.2 stator bars increased with increased in aging time. It has been concluded from the test that the stator insulation of the two generators are in good condition.

변압기내 부분방전 탐지 및 위치검출 (Detection and Location of Partial Discharge in Transformers)

  • 곽희노;김재철;황선주;권태원;윤용범
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제6권4호
    • /
    • pp.53-59
    • /
    • 1992
  • This paper describes an instrument for the detection and geometric location of partial discharge (PD) source in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulses and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used for detecting and locating PD in the transformer.

  • PDF

로고스키 코일과 초음파 센서를 이용한 변압기내 부분방전 탐지 및 위치검출 (Detection and Location of Partial discharge in Transformers Using Logoski coil and Ultrasonic sensor)

  • 곽희로;김재철;김웅상;한민구;권태원;윤용범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.279-282
    • /
    • 1990
  • This paper describes an nstrument for the detection and geometric location of partial discharge(PD) sources in transformers. This instrument measures electric current pulses and ultrasonic pulses simultaneously, counts the number of electrical pulse and determines the geometric location of PD in transformers. It was found that there is a relationship between partial discharge magnitude and pulse repetition rate when the applied test voltage and oil temperature were varied. Through the laboratory test using model transformer, it was clarified that this detector could be used, satisfactory for detecting and locating of PD in the transformer.

  • PDF

고압전동기 고정자 권선의 온도변화에 따른 절연특성 분석 (Analysis of the Temperature Influence on Insulation Characteristics in High Voltage Motor Stator Windings)

  • 공태식;주영호;김희동;박태성
    • 한국전기전자재료학회논문지
    • /
    • 제25권10호
    • /
    • pp.786-790
    • /
    • 2012
  • A variety of diagnostic tests are widely applied in the field in industry to evaluate the condition of high voltage (HV) motor stator insulation. In this paper, the influence of temperature on the stator insulation diagnostic tests such as the insulation resistance, AC current, dissipation factor, and partial discharge measurements are studied and reported. The tests are performed with the HV motor stator winding temperature set between $40^{\circ}C$ to $80^{\circ}C$ in $10^{\circ}C$ intervals. It is shown that the AC current, dissipation factor, and partial discharge magnitude steadily increase with temperature, which suggests that temperature must be taken into account in the interpretation of the test results.

대형 회전기의 절연진단결과와 경년 특성과의 상관관계에 관한 연구 (A Study on the Correlation between the Lapse of Time and Diagnostic Test Results of Large Rotating Machine Windings)

  • 김광화;조연옥;선종호;김영배;류희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.966-968
    • /
    • 1992
  • We have done the insulation diagnostic test of generators in domestic five power plants since 1987 and tested A.C. current increasing rate($\Delta$I), $\Delta$tan$\delta$ and partial discharge in generator winding insulation. This study is described the correlation between nondestructive result(A.C. current increasing rate, $\Delta$tan$\delta$ and partial discharge) and lapse of time in generators.

  • PDF

수력 발전기의 운전중 부분방전 측정기법에 대한 신뢰성 평가 (Evaluation of On-Line Partial Discharge Measurement Techniques on Hydro-Generator)

  • 황돈하;김진봉;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1526-1529
    • /
    • 1994
  • In hydro-generator, a groundwall insulation of stator windings gradually deteriorates due to mechanical, thermal, electrical and environmental stresses. These stresses combine to result in loose windings, delamination of the stator insulation and/or electrical tracking of the end winding, all of which can lead to stator insulation failures. Conventionally, off-line tests such as partial discharge measurement, DC/AC current test and ${\Delta}tan{\delta}$ test has been used for estimation of winding condition. However, off-line test requires large power supply and generator outage. In addition, major cause of insulation problems such as loose wedges and slot discharges may not be found with off-line diagnoses. This paper describes the on-line partial discharge measurement techniques in the generator stator windings. The experimental results from the UIAM #1 hydro-generator confirms a optimistic application of on-line generator diagnosis method as a reliable tool for evaluation of winding condition.

  • PDF