• 제목/요약/키워드: parallel structure analysis

검색결과 433건 처리시간 0.029초

Analysis of extended end plate connection equipped with SMA bolts using component method

  • Toghroli, Ali;Nasirianfar, Mohammad Sadegh;Shariati, Ali;Khorami, Majid;Paknahad, Masoud;Ahmadi, Masoud;Gharehaghaj, Behnam;Zandi, Yousef
    • Steel and Composite Structures
    • /
    • 제36권2호
    • /
    • pp.213-228
    • /
    • 2020
  • Shape Memory Alloys (SMAs) are new materials used in various fields of science and engineering, one of which is civil engineering. Owing to their distinguished capabilities such as super elasticity, energy dissipation, and tolerating cyclic deformations, these materials have been of interest to engineers. On the other hand, the connections of a steel structure are of paramount importance because of their vulnerabilities during an earthquake. Therefore, it is indispensable to find approaches to augment the efficiency and safety of the connection. This research investigates the behavior of steel connections with extended end plates equipped hybridly with 8 rows of high strength bolts as well as Nitinol superelastic SMA bolts. The connections are studied using component method in dual form. In this method, the components affecting the connections behavior, such as beam flange, beam web, column web, extended end plate, and bolts are considered as parallel and series springs according to the Euro-Code3. Then, the nonlinear force- displacement response of the connection is presented in the form of moment-rotation curve. The results obtained from this survey demonstrate that the connection has ductility, in addition to its high strength, due to high ductility of SMA bolts.

매립장 침출수 환경 재해에 관한 연구 (Analysis of Environmental Hazard by the Leachate from Disposal Waste)

  • 김준경;배효준;최오순
    • 한국방재학회 논문집
    • /
    • 제3권4호
    • /
    • pp.145-151
    • /
    • 2003
  • 생활폐기물 및 산업폐기물은 인간의 활동으로부터 배출되며 소각법 혹은 매립법 또는 2가지 방법을 동시에 이용하여 처리되고 있다. 특히 매립법은 침출수로 인하여 매립지가 있는 지역의 지하수계를 심각하게 오염시켜 환경재해를 발생시키고 있다. 따라서 오염지역의 침출수 오염특성을 3차원적으로 조사하여 환경재해를 최소화하는 것이 중요하다. 본 연구는 비위생 매립지인 충주시 노은 매립장의 3차원적 침출수 오염특성을 조사하였다. 조사를 위한 1개 측선의 방향은 주된 매립지 경계와 평행하도록 설치하였다. 노은 매립장을 탐사한 결과 가장 상부층은 안정화가 완전하게 진행되었으나 가장 하부층은 부분적으로 침출수가 일부 존재하는 것으로 분석되었다.

새로운 구조의 전광학적 WDM 출력 버퍼 (A novel all optical WDM output buffer)

  • 곽용석;송용훈;전창훈;정제명;신서용
    • 한국통신학회논문지
    • /
    • 제25권6A호
    • /
    • pp.862-869
    • /
    • 2000
  • 스위칭 시스템에서 버퍼는 라우팅시 신호간의 충돌을 방지하기 위해 반드시 필요하다. 광 스위칭 시스템에서도 단순한 광 교차 접속(OXC) 이상의 교환 및 라우팅을 수행하기 위해서는 광 버퍼를 필요로 한다. 오늘날 광전송 시스템 및 광 네트워크는 WDM을 기반으로 형성되어 가고 있으며 따라서 광 스위칭 역시 WDM 기술에 기반을 둘 것이고 이에 필요한 광 버퍼도 WDM 신호를 처리할 수 있어야 한다. WDM 스위칭 시스템에서 동시에 동일 가입자로 라우팅된 WDM 신호들을 순차적으로 출력시키기 위해 WDM 광 출력 버퍼를 필요로 한다. 본 논문에서는 기존의 발표된 WDM 광 출력 버퍼에 비해 구조, 하드웨어, SNR 및 BER 특성이 개선된 새로운 구조의 WDM 광 출력 버퍼를 제안한다. 제안한 버퍼에 대한 특성 분석결과, 새로운 구조의 버퍼는 버퍼를 구성하는 광 게이트(반도체 광 증폭기)의 이득 ON-OFF 비율(Contrast ratio)이 30dB인 경우, BER 10-9을 만족하면서 255개의 WDM셀을 저장할 수 있음을 알 수 있다.

  • PDF

개선된 자속구속형 전류제한기의 사고 시점에 따른 사고전류제한 특성 (Characteristics according to the spot at the beginning of the fault current)

  • 김용진;두호익;이동혁;한상철;이정필;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.189-189
    • /
    • 2010
  • The Improved flux-lock type superconducting fault current limiter(SFCL) is composed of a series transformer and superconducting unit of the YBCO coated conductor. The primary and secondary coils in the transformer were wound in series each other through an iron core and the YBCO coated conductor was connected with secondary coil in parallel. In a normal condition, the flux generated from a primary coil is cancelled out by its structure and the zero resistance of the YBCO thin films. When a fault occurs, the resistance of the YBCO coated conductor was generated and the fault current was limited by the SFCL. In this paper, we investigated the fault current limiting characteristics through the spot at the beginning of the fault current in the Improved flux-lock type SFCL. The experiment results that the fault current limiting characteristics was difference according to the point of a fault current started. Through the analysis, it was shown that shorter the time of a phase transition.

  • PDF

도체 두께를 가진 결합선로를 이용하여 강한 결합특성을 갖는 1/4파장 역방향 방향성 결합기의 설계 (Design of Tight Coupled 1/4 Wavelength Backward-Wave Directional Coupler using Coupled Lines with Finite Metallization Thickness)

  • 홍익표;윤남일;육종관
    • 한국전자파학회논문지
    • /
    • 제14권10호
    • /
    • pp.1004-1010
    • /
    • 2003
  • 본 논문에서는 유한한 도체 두께를 갖는 결합선로를 이용하여 1/4파장 역방향 방향성 결합기를 설계하였다. 방향성 결합기를 구성하는 유한 도체 두께를 갖는 결합선로를 해석하기 위한 방법으로 간단하고 빠른 수치해석 방법인 모드정합법을 사용하였다. 본 논문의 해석 결과는 도체 두께를 고려한 역방향 방향성 결합기의 설계가, 도체 두께를 고려하지 않고 설계한 경우 기존에 알려졌던 단점들인 약한 결합특성, 낮은 지향성, 그리고 비현실적인 결합선로의 폭을 극복할 수 있음을 보여준다. 또한, 수치해석 결과로부터 l/4파장 역방향 방향성 결합기에서는 도체 두께의 고려로 강한 결합특성을 만드는 것이 가능하지만, 결합길이가 약간 길어진다는 사실을 확인하였다. 본 논문에서 해석한 유한한 도체 두께는 역방향 방향성 결합기의 새로운 설계 변수로서 사용이 가능하며, 아울러 다양한 마이크로파 집적회로의 설계에도 응용이 가능함을 보여준다.

성인 체중을 고려한 로봇의 지능형 발을 위한 6축 힘/모멘트센서 개발 (Development of 6-Axis Force/Moment Sensor Considered Adult Weight for a Humanoid Robot's Foot)

  • 김갑순;윤정원
    • 한국정밀공학회지
    • /
    • 제24권7호
    • /
    • pp.90-97
    • /
    • 2007
  • This paper describes the development of 6-axis force/moment sensor considered adult weight far an intelligent foot of humanoid robot. In order to walk on uneven terrain safely, the foot should perceive the applied forces Fx, Fy, Fz and moments Mx, My, Mz to itself and control the foot using the forces and moments. The applied forces and moments should be measured from a 6-axis force/moment sensor attached to the foot, which is composed of Fx sensor, Fy sensor, Fz sensor, Mx sensor, My sensor and Mz sensor in a body. Each sensor should get the deferent rated load, because the applied forces and moments to foot in walking are deferent. Therefore, one of the important things in the sensor is to design each sensor with the deferent rated load and the same rated output. In this paper, a 6-axis force/moment sensor (rated load of Fx and Fy are 500Nm and Fz sensor is 1000N, and those of Mx and My are 18Nm, Mz sensor is 8Nm) for perceiving forces and moments in a humanoid robot's foot was developed using many PPBs (parallel plate-beams). The structure of the sensor was newly modeled, and the sensing elements (plate-beams) of the sensor were designed using by ANSYS software (FEM (Finite Element Method) program). Then, a 6-axis force/moment sensor was fabricated by attaching strain-gages on the sensing elements, and the characteristic test of the developed sensor was carried out. The rated outputs from FEM analysis agree well with that from the characteristic test.

PARSEC을 이용한 TILE-Gx36 다중코어 프로세서의 성능 평가 및 분석 (Performance evaluation and analysis of TILE-Gx36 many-core processor with PARSEC benchmark)

  • 이보선;김한이;유헌창;서태원
    • 컴퓨터교육학회논문지
    • /
    • 제17권1호
    • /
    • pp.107-115
    • /
    • 2014
  • 본 논문은 다중코어의 성능을 평가하고 분석하기 위해 TILE-Gx36(Gx36) 다중코어 프로세서를 사례로 연구하였다. Gx36의 성능 평가는 비교적 최신 병렬 벤치마크인 PARSEC을 이용하였고, 성능 분석을 돕기 위한 비교 시스템으로 인텔의 Core i7 (i7)과 Atom을 사용하였다. 실험결과 2의 제곱으로 동시에 수행 가능한 스레드를 발생시켰을 때, Gx36은 i7보다 평균 2.73배 낮은 성능을 보였으며, Atom보다는 평균 1.93배 높은 성능을 보였다. Gx36은 비교 프로세서보다 상대적으로 큰 Last-Level Cache(LLC)를 갖고 있음에도 불구하고, 가장 많은 LLC miss를 발생시켰다. 이는 Gx36이 기대치 이하의 성능을 보이는 주된 이유로 판단되며, DDC가 일반적 고성능 컴퓨팅을 위한 캐시구조로 적절하지 않음을 보여준다. 다중코어 시스템의 실측을 통한 성능평가는 향후 다중코어 구조개선 및 올바른 방향 설정을 위한 객관적인 자료를 제공한다.

  • PDF

$\lambda$/4 Hairpin 공진기를 이용한 2.4 GHz 대역 LTCC 대역통과 필터의 설계 (The Design of 2.4 GHz Band LTCC Bandpass Filter using $\lambda$/4 Hairpin Resonators)

  • 성규제
    • 마이크로전자및패키징학회지
    • /
    • 제11권4호
    • /
    • pp.7-11
    • /
    • 2004
  • 본 논문에서는 $\lambda$/4 헤어핀 공진기를 2.4 GHz 대역의 LTCC(Low Temperature Co-fire Ceramic) 대역통과 필터의 설계에 적용하였다. $\lambda$/4 헤어핀 공진기는 전송선로의 폭을 일정하게 유지한 상태로 특성임피던스를 변화시킬 수 있어, 등가적으로 SIR(Stepped Impedance Resonator)로 동작한다. $\lambda$/4 헤어핀 공진기는 평행결합 선로와 전송선로 부분으로 구성된다. 따라서 공진기의 두 부분의 특성임피던스는 서로 다른 값을 갖는다. 또한 공진기 사이의 결합량을 조절하기 위하여 사용하는 부가적인 결합 패턴은 결합위치에 따라 결합량을 다르게 할 수 있다. 평행 결합선로의 결합 구조와 부가적인 결합 패턴을 모두 고려한 대역통과 필터를 설계하기 위해서 두 결합구조의 등가회로를 하나의 인버터로 통합하는 과정을 제시하였다. 2.4GHz 대역에서 150 MHz 대역폭의 대역통과 필터를 적층 구조로 설계하여 설계 결과와 잘 일치하는 특성을 얻었다.

  • PDF

In-memory data grid 기술을 활용한 택시 애플리케이션 성능 향상 기법 연구 (Enhancing the performance of taxi application based on in-memory data grid technology)

  • 최치환;김진혁;박민규;권가은;정승현;프란코 나자레노;조완섭
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권5호
    • /
    • pp.1035-1045
    • /
    • 2015
  • 최근 빅데이터 분야에서 데이터를 메모리에 적재 후 빠르게 처리하는 인메모리 컴퓨팅 기술이 새롭게 부각되고 있다. 인메모리 컴퓨팅 기술은 과거 대용량 메모리와 다중 프로세서를 탑재한 고성능서버에 적용 가능하였지만, 점차 일반 컴퓨터를 초고속 네트워크로 연결하여 분산 병렬처리가 가능한 구조로 변화하고 있다. 본 논문은 In-memory data grid (IMDG) 기술을 택시 애플리케이션에 접목하여 기존의 데이터베이스의 변경 없이 성능을 향상시키는 기법을 제안한다. IMDG 기술을 적용한 경우 기존의 데이터베이스 기반의 웹서비스에 비해 처리속도와 처리량이 평균 6~9배정도 증가하며, 또한 부하량에 따른 처리량 변화의 폭이 매우 작음을 확인 하였다.

아치형 단동하우스의 풍력계수 분포에 관한 연구 (Distribution of Wind Force Coefficients on the Single-span Arched House)

  • 이석건;이현우
    • 생물환경조절학회지
    • /
    • 제1권1호
    • /
    • pp.28-36
    • /
    • 1992
  • The wind pressure distributions were analyzed to provide fundamental criteria for the structural design on e single-span arched house according to the wind directions through the wind tunnel experiment. In order to investigate the wind force distributions, the variation of the wind force coefficients, the mean wind force coefficients, the drag force coefficients and the lift force coefficients were estimated by using the experimental data. The results obtained are as follows: 1. When the wind direction was normal to the wall, the maximum positive wind pressure along the height of the wall occurred approximately at two-thirds of the wall height because of the effects of boundary layer flow. 2. When the wind direction was 30$^{\circ}$ to the wall, the maximum positive wind force occurred at the windward edge of the wall. When the wind direction was parallel to the wall, the maximum negative wind force occurred at the windward edge of the wall. 3. The maximum negative wind force along the width of the roof appeared around the width ratio, 0.4, and that along the length of the roof appeared around the length ratio, 0.5. 4. According to the results of the mean wind force coefficients analysis, the maximum negative wind force occurred on the roof at the wind direction of 30$^{\circ}$. 5. The wind forces at the wind direction of 30$^{\circ}$ instead of 0$^{\circ}$ are recommended in the structural design of supports for a house. 6. To prevent partial damage of a house structure by wind forces, the local wind forces should be considered to the structural design of a house.

  • PDF