• Title/Summary/Keyword: parallel connection

Search Result 357, Processing Time 0.035 seconds

Improvement of Quench Properties of a Superconducting Fault Current Limiter Using YBCO Films by Serial and Parallel Combinations (직.병렬 조합에 의한 박막형 초전도 한류기의 퀜치특성 개선)

  • 최효상;김혜림;현옥배
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.52 no.7
    • /
    • pp.315-319
    • /
    • 2003
  • We improved quench properties of a superconducting fault current limiter (SFCL) based on YBCO thin films by their serial and parallel combinations. The SFCL consisted of 6 switching elements fabricated of 4 inch-diameter YBCO thin films. The quench currents of the switching elements were distributed between 33.9 A and 35.6 A. Simple serial connection resulted in imbalanced power dissipation between switching elements even at the quench current difference of 0.6 A. On the other hand, $2{\times}2$ and $3{\times}2$ stack combinations produced simultaneous quenches. The $3{\times}2$ stack combination showed better simultaneous quench behavior than the $2{\times}2$ stacks. This is suggested to be because the currents between switching elements in parallel connection of the $3{\times}2$ stacks were more effectively redistributed than the $2{\times}2$ stacks.

Analysis of Series and Parallel Operation Characteristics using Physical Models of Power Devices (물리적인 전력소자 모델을 이용한 직$\cdot$병렬운전 특성 해석)

  • Yoon, Jae-Hak;Park, Gun-Tae
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.213-217
    • /
    • 2002
  • Power devices for high power drivers that need high switching speed (IGCT, HVIGBT) have been continuously developed. However, serial and parallel connections using several much cheaper, lower power capacity of devices than an expensive high power device are very useful methods in the aspect of cost down and high power application. Even the current and voltage unbalance problem is occurred at each devices. This unbalance characteristics are mainly caused by the differences of physical characteristics of each devices and the line inductance (stray inductance) of bus bars that consist of current path. This paper deals simulation analysis of serial connection of IGCTs and parallel connection of IGCTs using physical model of devices. And also, introduces the method to reduce the voltage and current unbalance problem.

  • PDF

Types of Misconceptions and their Consistencies of the Elementary School Teachers about the Characteristics of Currents according to the Connection Methods of Batteries in Simple Electric Circuits (전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성)

  • Hyun, Dong-Geul;Shin, Ae-Kyung
    • Journal of Science Education
    • /
    • v.38 no.2
    • /
    • pp.331-343
    • /
    • 2014
  • The types of misconceptions and their consistencies of the elementary school teachers about the characteristics of currents according to the connection methods of batteries in simple electric circuits were investigated. The misconceptions of the elementary school teachers about them could be divided into three types. Among the respondents of the 96 elementary school teachers for this study, the 2 elementary school teachers consistently understood the characteristics of currents on the basis of the misconception type of focusing only the number of batteries connected regardless of the connection methods of batteries, the 8 elementary school teachers did on the basis of the misconception type of confusing the series connection and the parallel connection of batteries, and the 4 elementary school teachers did on the basis of the misconception type of confusing the series and parallel connection of batteries with those of resistors. Also, they consistently applied these misconception types to not only the situations to use the learned concepts but the situations to use the differentiated concepts about the connection methods of batteries.

  • PDF

A FLOW CHARACTERISTICS FOR Y-CONNECTION IN HIGH-REYNOLDS-NUMBER FLOW SYSTEM (고레이놀즈수 유동 장치에서 Y형 이음의 유동 특성)

  • Park, Jung Gun;Park, Jong Ho;Park, Young Chul
    • Journal of computational fluids engineering
    • /
    • v.18 no.2
    • /
    • pp.1-8
    • /
    • 2013
  • In nuclear power plant, the reactor cooling system has maintained high-Reynolds-number flow above 1E+07 to cool a heat generated by the reactor. To minimize uncertainty for flow calibration, it is necessary to simulate the high Reynolds' number flow. Y-connection is selected to connect four (4) parallel high flow circulation pumps for maintaining the high flow rate. This paper describes the characteristics for Y-connection by computer flow simulation. It was confirmed through the results that the pressure loss of the Y-connection was lower than that of T-connection. Also as the connection angle of Y-connection was small, as the pressure loss was low.

Reconfiguration of PV Module Considering the Shadow Influence of Photovoltaic System (태양광 발전시스템의 그림자 영향을 고려한 PV 모듈의 재구성)

  • Ko, Jae-Sub;Chung, Dong-Hwa
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.2
    • /
    • pp.36-44
    • /
    • 2013
  • This paper proposes the reconfiguration of PV module considering shadow influence of photovoltaic system. The PV system is consisted series-parallel connection of PV module. The voltage and current between PV modules become unbalance when shadow occurs to PV module. If shadow occurs to the series connection PV module, the output current is limited to current of shaded PV module. Also if shadow occurs to the parallel connection PV module, the output voltage is limited to voltage of shaded PV module. These problems are caused power loss. Therefore, the PV module in this paper consist using the fixed module and variable module by shaded conditions. The reconfiguration of PV module can compensates the shadow influence by changing connection of a variable module when shadow is occurred to PV module. A validity of the reconfiguration of PV module proposed in this paper proves through comparing with performance of conventional PV module.

COMPARATIVE ACCURACY OF THE SPLINTED AND UNSPLINTED IMPRESSION METHODS FOR INTERNAL CONNECTION

  • Choi, Jung-Han;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jin
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.352-362
    • /
    • 2005
  • Statement of problem. Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems. Purpose. The purpose of this study was to compare the accuracy of two fixture-level impression techniques in two conditions (parallel and divergent) and to assess the effect of tightening sequences and forces on stresses generated on superstructures in internal connection implant system (Astra Tech). Material and methods. Two metal master frameworks made from two abutments (Cast-to Abutment ST) each and a corresponding, passively fitting, dental stone master cast with four fixture replicas (Fixture Replica ST) were fabricated. Ten dental stone casts for each impression techniques (direct unsplinted & splinted technique) were made with vinyl polysiloxane impressions from the master cast. Strain gauges for each framework were fixed midway between abutments to measure the degree of framework deformation on each stone cast. Pairs of strain gauges placed opposite each other constituted one channel (half Wheatstone bridge) to read deformation in four directions (superior, inferior, anterior, and posterior). Deformation data were analyzed using one-way ANOVA and the Tukey test at the .01 level of significance. And the effect of tightening sequences (right-to-left and left-to-right) and forces (10 Ncm and 20 Ncm) were assessed with ten stone casts made from parallel condition by the splinted technique. Deformation data were analyzed using paired t-test at the .01 level of significance. Conclusions. Within the limitations of this study, the following conclusions could be drawn. 1. Frameworks bent toward the inferior side on all casts made by both direct unsplinted and splinted impression techniques in both parallel and divergent conditions. 2. There was no statistically significant difference of accuracy between the direct unsplinted and splinted impression techniques in both parallel and divergent conditions (P>.01). 3. There was no statistically significant difference of stress according to screw tightening sequences in casts made by the splinted impression technique in parallel condition (P>.01). 4. Greater tightening force resulted in greater stress in casts made by the splinted impression technique in parallel condition (P<.01).

Characteristics of 15 kVA Superconducting Fault Current Limiters Using Thin Films (15 kVA급 박막형 초전도 전류제한기의 한류특성)

  • 최효상;현옥배;김혜림;황시돌
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1058-1062
    • /
    • 2000
  • We investigated resistive superconducting fault current limites (SFCLs) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 A$\_$peak/, was produced and successfully tested at a 220 V$\_$rms/circuit. From the resistance increase, we estimated that the film temperature increased to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V$\_$rms/.

  • PDF

Connection Control and Network Management of OBS with GSMP Open Interface (GSMP 개방형 인터페이스 기반의 OBS 연결 제어 및 망 관리 메커니즘)

  • Choi In-Sang;Kim Choon-Hee;Cha Young-Wook;Kwon Tae-Hyun
    • Journal of Korea Multimedia Society
    • /
    • v.9 no.1
    • /
    • pp.89-100
    • /
    • 2006
  • The introduction of GSMP open interface to OBS network can materialize to separate the transport plane and the control plane in OBS network. This makes the implementation of OBS switches simple and provides various flexibility. However, the introduction of open interface will cause the connection setup delay because of the additional processing overhead of open interface protocol. Also, in GSMP based network, the location of network management functions are not defined explicitly and the research result about the OBS network management is almost nothing. This paper proposes a parallel connection setup mechanism using centralized connection control server to minimize connection setup delay in OBS network with GSMP open interface and defines managed objects to support connection, configuration, performance, and fault management for the management of OBS network with GSMP open interface. This paper also proposes a distributed network management model, in which the above managed objects are distributed in a controller and an OBS switch according to network management functions. We verify the possibility of OBS control and network management by implementing network management function using proposed parallel connection setup mechanism and distributed network management model.

  • PDF

Winding Connection Changing Converter for Traction SRM (견인용 SRM의 운전특성개선을 위한 권선전환컨버터)

  • Kim, Tae-Hyoung;Lee, Dong-Hee;An, Young-Joo;Ahn, Jin-Woo
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.659-660
    • /
    • 2008
  • This paper presents a hybrid winding connection method for torque characteristics improving of a traction SRM. In order to get a high torque in wide speed range and torque ripple reduction, series and parallel winding connection are changed according to operating speed. From the analysis of torque character operation mode and efficiency, the proposed control scheme is verified.

  • PDF