• 제목/요약/키워드: parallel connection

검색결과 357건 처리시간 0.047초

직.병렬 조합에 의한 박막형 초전도 한류기의 퀜치특성 개선 (Improvement of Quench Properties of a Superconducting Fault Current Limiter Using YBCO Films by Serial and Parallel Combinations)

  • 최효상;김혜림;현옥배
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권7호
    • /
    • pp.315-319
    • /
    • 2003
  • We improved quench properties of a superconducting fault current limiter (SFCL) based on YBCO thin films by their serial and parallel combinations. The SFCL consisted of 6 switching elements fabricated of 4 inch-diameter YBCO thin films. The quench currents of the switching elements were distributed between 33.9 A and 35.6 A. Simple serial connection resulted in imbalanced power dissipation between switching elements even at the quench current difference of 0.6 A. On the other hand, $2{\times}2$ and $3{\times}2$ stack combinations produced simultaneous quenches. The $3{\times}2$ stack combination showed better simultaneous quench behavior than the $2{\times}2$ stacks. This is suggested to be because the currents between switching elements in parallel connection of the $3{\times}2$ stacks were more effectively redistributed than the $2{\times}2$ stacks.

물리적인 전력소자 모델을 이용한 직$\cdot$병렬운전 특성 해석 (Analysis of Series and Parallel Operation Characteristics using Physical Models of Power Devices)

  • 윤재학;박건태
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.213-217
    • /
    • 2002
  • Power devices for high power drivers that need high switching speed (IGCT, HVIGBT) have been continuously developed. However, serial and parallel connections using several much cheaper, lower power capacity of devices than an expensive high power device are very useful methods in the aspect of cost down and high power application. Even the current and voltage unbalance problem is occurred at each devices. This unbalance characteristics are mainly caused by the differences of physical characteristics of each devices and the line inductance (stray inductance) of bus bars that consist of current path. This paper deals simulation analysis of serial connection of IGCTs and parallel connection of IGCTs using physical model of devices. And also, introduces the method to reduce the voltage and current unbalance problem.

  • PDF

전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성 (Types of Misconceptions and their Consistencies of the Elementary School Teachers about the Characteristics of Currents according to the Connection Methods of Batteries in Simple Electric Circuits)

  • 현동걸;신애경
    • 과학교육연구지
    • /
    • 제38권2호
    • /
    • pp.331-343
    • /
    • 2014
  • 전지의 연결방법에 따른 전류의 특성에 대한 초등교사들의 오개념 유형과 그 일관성에 대하여 조사되었다. 초등교사들의 전지의 연결방법에 따른 전류의 특성에 대한 오개념은 3가지 유형으로 나타났다. 14명의 초등교사들을 대상으로 한 이 연구에서, 전지들의 직렬연결과 병렬연결시 전류의 특성을 연결하는 전지의 수에 초점을 맞추는 유형에는 2명의 초등교사가, 전지의 직렬연결에 대한 개념과 병렬연결에 대한 개념을 혼동하는 유형에는 8명의 초등교사가, 그리고 전지의 직렬연결과 병렬연결에 대한 개념을 저항의 직렬연결과 병렬연결에 대한 개념으로 혼동하는 유형에는 4명의 초등교사가 분포하였다. 초등교사들은 전지의 연결에 대한 학습개념이 적용되는 상황에서 뿐만 아니라 분화개념이 적용되어야 하는 상황에서도 그들의 오개념 유형을 일관성 있게 적용하고 있었다.

  • PDF

고레이놀즈수 유동 장치에서 Y형 이음의 유동 특성 (A FLOW CHARACTERISTICS FOR Y-CONNECTION IN HIGH-REYNOLDS-NUMBER FLOW SYSTEM)

  • 박정근;박종호;박용철
    • 한국전산유체공학회지
    • /
    • 제18권2호
    • /
    • pp.1-8
    • /
    • 2013
  • In nuclear power plant, the reactor cooling system has maintained high-Reynolds-number flow above 1E+07 to cool a heat generated by the reactor. To minimize uncertainty for flow calibration, it is necessary to simulate the high Reynolds' number flow. Y-connection is selected to connect four (4) parallel high flow circulation pumps for maintaining the high flow rate. This paper describes the characteristics for Y-connection by computer flow simulation. It was confirmed through the results that the pressure loss of the Y-connection was lower than that of T-connection. Also as the connection angle of Y-connection was small, as the pressure loss was low.

태양광 발전시스템의 그림자 영향을 고려한 PV 모듈의 재구성 (Reconfiguration of PV Module Considering the Shadow Influence of Photovoltaic System)

  • 고재섭;정동화
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.36-44
    • /
    • 2013
  • This paper proposes the reconfiguration of PV module considering shadow influence of photovoltaic system. The PV system is consisted series-parallel connection of PV module. The voltage and current between PV modules become unbalance when shadow occurs to PV module. If shadow occurs to the series connection PV module, the output current is limited to current of shaded PV module. Also if shadow occurs to the parallel connection PV module, the output voltage is limited to voltage of shaded PV module. These problems are caused power loss. Therefore, the PV module in this paper consist using the fixed module and variable module by shaded conditions. The reconfiguration of PV module can compensates the shadow influence by changing connection of a variable module when shadow is occurred to PV module. A validity of the reconfiguration of PV module proposed in this paper proves through comparing with performance of conventional PV module.

COMPARATIVE ACCURACY OF THE SPLINTED AND UNSPLINTED IMPRESSION METHODS FOR INTERNAL CONNECTION

  • Choi, Jung-Han;Kim, Chang-Whe;Jang, Kyung-Soo;Lim, Young-Jin
    • 대한치과보철학회지
    • /
    • 제43권3호
    • /
    • pp.352-362
    • /
    • 2005
  • Statement of problem. Accurate impression is essential to success of implant prostheses. But there have been few studies about the accuracy of fixture-level impression techniques in internal connection implant systems. Purpose. The purpose of this study was to compare the accuracy of two fixture-level impression techniques in two conditions (parallel and divergent) and to assess the effect of tightening sequences and forces on stresses generated on superstructures in internal connection implant system (Astra Tech). Material and methods. Two metal master frameworks made from two abutments (Cast-to Abutment ST) each and a corresponding, passively fitting, dental stone master cast with four fixture replicas (Fixture Replica ST) were fabricated. Ten dental stone casts for each impression techniques (direct unsplinted & splinted technique) were made with vinyl polysiloxane impressions from the master cast. Strain gauges for each framework were fixed midway between abutments to measure the degree of framework deformation on each stone cast. Pairs of strain gauges placed opposite each other constituted one channel (half Wheatstone bridge) to read deformation in four directions (superior, inferior, anterior, and posterior). Deformation data were analyzed using one-way ANOVA and the Tukey test at the .01 level of significance. And the effect of tightening sequences (right-to-left and left-to-right) and forces (10 Ncm and 20 Ncm) were assessed with ten stone casts made from parallel condition by the splinted technique. Deformation data were analyzed using paired t-test at the .01 level of significance. Conclusions. Within the limitations of this study, the following conclusions could be drawn. 1. Frameworks bent toward the inferior side on all casts made by both direct unsplinted and splinted impression techniques in both parallel and divergent conditions. 2. There was no statistically significant difference of accuracy between the direct unsplinted and splinted impression techniques in both parallel and divergent conditions (P>.01). 3. There was no statistically significant difference of stress according to screw tightening sequences in casts made by the splinted impression technique in parallel condition (P>.01). 4. Greater tightening force resulted in greater stress in casts made by the splinted impression technique in parallel condition (P<.01).

15 kVA급 박막형 초전도 전류제한기의 한류특성 (Characteristics of 15 kVA Superconducting Fault Current Limiters Using Thin Films)

  • 최효상;현옥배;김혜림;황시돌
    • 한국전기전자재료학회논문지
    • /
    • 제13권12호
    • /
    • pp.1058-1062
    • /
    • 2000
  • We investigated resistive superconducting fault current limites (SFCLs) fabricated using YBCO thin films on 2-inch diameter sapphire substrates. Nearly identical SFCL units were prepared and tested. The units were connected in series and parallel to increase the current and voltage ratings. A serial connection of the units showed significantly unbalanced power dissipation between the units. This imbalance was removed by introducing a shunt resistor to the firstly quenched unit. Parallel connection of the units increased the current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current rating. An SFCL module of 4 units in parallel, each of which has minimum quench current 25 A$\_$peak/, was produced and successfully tested at a 220 V$\_$rms/circuit. From the resistance increase, we estimated that the film temperature increased to 200 K in 5 msec, and 300 K in 120 msec. Successive quenches revealed that this system is stable without degradation in the current limiting capability under such thermal shocks as quenches at 220 V$\_$rms/.

  • PDF

GSMP 개방형 인터페이스 기반의 OBS 연결 제어 및 망 관리 메커니즘 (Connection Control and Network Management of OBS with GSMP Open Interface)

  • 최인상;김춘희;차영욱;권태현
    • 한국멀티미디어학회논문지
    • /
    • 제9권1호
    • /
    • pp.89-100
    • /
    • 2006
  • OBS 망을 위한 GSMP 개방형 인터페이스 도입은 OBS 망의 전달평면과 제어평면의 분리를 실현하여 OBS 스위치의 구현을 단순화시키고, 망의 다양한 융통성을 제공한다. 그러나 GSMP 프로토콜의 실행 오버헤드로 인하여 연결설정이 증가하는 단점이 있다. 또한 GSMP 개방형 인터페이스에서 망 관리의 위치가 제어기인지, 스위치인지 명확하게 규정되어 있지 않으며, OBS에 대한 망 관리의 연구결과는 전무한 상태이다. 본 논문에서는 GSMP 개방형 인터페이스 기반의 OBS 망에서 연결설정 지연을 최소화하기 위하여 중앙집중형 연결제어 서버를 이용한 병렬형 연결설정 메커니즘을 제안한다. 또한 GSMP 개방형 인터페이스가 적용된 OBS 망의 연결, 구성, 성능 및 장애관리를 위한 관리객체를 정의하고, 이들 관리 정보가 관리 기능별로 OBS 스위치와 제어기에 분산되어 탑재되는 분산 망 관리 모델을 제안한다. 제안한 병렬형 연결설정 메커니즘 및 분산 망 관리 모델을 이용한 망 관리 기능의 구현을 통하여 OBS 제어 및 망 관리의 실현성을 확인하였다.

  • PDF

견인용 SRM의 운전특성개선을 위한 권선전환컨버터 (Winding Connection Changing Converter for Traction SRM)

  • 김태형;이동희;안영주;안진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.659-660
    • /
    • 2008
  • This paper presents a hybrid winding connection method for torque characteristics improving of a traction SRM. In order to get a high torque in wide speed range and torque ripple reduction, series and parallel winding connection are changed according to operating speed. From the analysis of torque character operation mode and efficiency, the proposed control scheme is verified.

  • PDF