• Title/Summary/Keyword: panoramic

Search Result 880, Processing Time 0.024 seconds

Effective dose of cone-beam computed tomography for orthodontic analysis in pediatric patient (소아환자에서 교정분석을 위한 콘빔CT 촬영시 유효선량에 관한 연구)

  • Kim, Eun-Kyung
    • The Journal of the Korean dental association
    • /
    • v.53 no.8
    • /
    • pp.558-568
    • /
    • 2015
  • Objective: The objectives of this study were to measure pediatric organ and effective doses of cone-beam computed tomography (CBCT) for orthodontic analysis and to compare them to those of panoramic and lateral cephalometric radiography, the conventional radiography for orthodontic analysis. Materials and Methods: Alphard VEGA for CBCT, Planmeca Proline XC for panoramic radiography and Orthophos CD for cephalometric radiography were used for this study. Thermoluminescent dosimeter (TLD) chips were located at 24 anatomic sites of 10-year-old anthropomorphic phantom and exposed during CBCT (C-mode; $200{\times}179mm$ FOV), panoramic and lateral cephalometric radiographic procedures at the clinical exposure settings for 10-year-old patient. Pediatric organ and effective doses were measured and calculated using ICRP 2007 tissue weighting factors. Results: Effective doses of CBCT, panoramic radiography and lateral cephlometric radiography in pediatric clinical exposure settings were $292.5{\mu}Sv$, $19.3{\mu}Sv$, and $4.4{\mu}Sv$ respectively. The thyroid gland contributed most significantly to the effective dose in all the radiographic procedures. Conclusion: Effective dose of CBCT was about 12 times to conventional radiographic procedures for orthodontic analysis in pediatric patient. The use of CBCT for orthodontic analysis should be fully justified over conventional radiography and dose optimization to decrease thyroid dose is needed in pediatric patients.

A STUDY ON SIALOGRAPHIC IMAGE OF NORMAL PAROTID GLANDS BY PANORAMIC VIEW (Panorama 촬영술에 의한 정상 성인 이하선 조영상에 관한 연구)

  • Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.26 no.2
    • /
    • pp.7-17
    • /
    • 1996
  • This study was performed to determine the postitional relationships of two lobes of parenchyma and to analysis the anatomical feature and its variations of duct on the panoramic views of the normal parotid glands in adults. Materials included 66 panoramic views and anterioposterior views of sialograms of selected persons and the radiograms of the gland experimentally reproduced on dry skull with lead foil and the reference images of computed tomograms of normal persons. Results were as follows : 1. On panoramic view of sialogram, the superficial lobe was revealed with totally being superimposed with the mandibular ramus and condyle and its tail portion superimposed with mandibular angle area, the deep lobe was revealed between the posterior border of the ramus and the mastoid process, and the isthmus was begin from the marked furcation off main duct and superimposed partially with the medial part of the deep lobe. 2, The mean length and the lateral extension of parenchyma was 63.18±8.05mm and 21.78±4.87mm respectively on panoramic view and showed no statistical relationship between them. 3. The main duct was generally perpendicular to the posterior border of ramus at middle portion and its configurations revealed 57,58% of curvilinear type, 21.21% sigmoid type, 15.15% reverse sigmoid type. 4, The interlobular ducts of the deep lobe showed relatively well defined features between the mandibular ramus and the mastoid process.

  • PDF

Prediction of osteoporosis using fractal analysis et cetera on panoramic radiographs (파노라마 방사성사진에서 프랙탈 분석 등을 이용한 골다공증 예측)

  • Kim, Joo-Yeon;Nah, Kyung-Soo
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.79-82
    • /
    • 2007
  • Purpose: The purpose of this study was to investigate whether panoramic radiographs were useful in predicting osteoporosis. Materials and Methods: 50 postmenoposal women between the age of 41.8 and 78.5 were classified as normal and osteoporosis groups according to the bone mineral density of lumbar vertebrae. Panoramic radiographs were taken. Age, body mass index, remaining mandibular teeth, mandibular cortical thickness and morphology, and fractal dimensions at periapical areas of mandibular first molars were evaluated to differentiate the two groups. Results: The age of osteoporotic group was statistically significantly higher than that of normal group (p<0.05), but not the body mass index or number of remaining mandibular teeth. The mean fractal dimension of osteoporotic group was $1.391{\pm}0.085$, and was significantly lower than that of the normal group, which was $1.523{\pm}0.725$ (p<0.01). Thick mandibular cortical thickness was common in normal group, whereas thin or very thin mandibular cortical thickness was common in osteoporotic group and the difference was significant (p < 0.05). C2 pattern was common in normal group followed by C1, whereas C2 was common in osteoporotic group followed by C3. The difference was statistically significant (p< 0.0 1). Conclusion: Age, mandibular cortical thickness and shape, fractal dimension on panoramic radiographs were useful in predicting osteoporosis.

  • PDF

Absorbed and effective dose from newly developed cone beam computed tomography in Korea (최근 개발된 cone beam computed tomography의 흡수선량 및 유효선량 평가)

  • Lee, Jong-Nyeong;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.37 no.2
    • /
    • pp.93-102
    • /
    • 2007
  • Purpose: Cone beam computed tomography (CBCT) provides a lower dose and cost alternative to conventional CT, promising to revolutionize the practice of oral and maxillofacial radiology. The purpose of this study was to evaluate the absorbed and effective doses of Implagraphy and VCT (Vatech Co., Hwasung, Korea) and compare them with those of panoramic radiography. Materials and Methods: Thermoluminescent dosimeter (TLD) chips were placed at 27 sites throughout the layers of Female ART Head and Neck Phantom for dosimetry. Implagraphy, VCT units, and Planmeca Proline XC panoramic unit were used for radiation exposures. Radiation weighted doses and effective doses were measured and calculated using 1990 and 2005 ICRP tissue weighting factors. Results: Effective doses in Sv (ICRP 2005, ICRP 1990) were 90.19, 61.62 for Implagraphy at maxillay molar area, 123.20, 90.02 for Implagraphy at mandibular molar area, 183.55, 139.26 for VCT and 40.92, 27.16 for panoramic radiography. Conclusion: Effective doses for VCT and Implagraphy were only about 2.2 to 4.5 times greater than those for panoramic radiography. VCT and Implagraphy, CBCT machines recently developed in Korea, showed moderately low effective doses.

  • PDF

Radiographic changes of mandibular cortical bone in bisphosphonate drug holiday

  • Lee, Dae-Hoon;Seo, Ja-In;Song, Seung-Il;Lee, Jeong-Keun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.48 no.4
    • /
    • pp.219-224
    • /
    • 2022
  • Objectives: There have been few studies to date on the residual effect of bisphosphonate. This study investigated the radiographic changes of mandibular cortical thickness upon bisphosphonate drug holiday. Materials and Methods: This retrospective study includes 36 patients diagnosed with MRONJ (medication-related osteonecrosis of the jaw) at Ajou University Dental Hospital in 2010-2021. All patients stopped taking bisphosphonate under consultation with the prescribing physicians. Panoramic radiographs were taken at the start of discontinuation (T0), 12 months after (T1), and 18 months after (T2) discontinuation of bisphosphonate, respectively. Mental index and panoramic mandibular index were calculated using Ledgerton's method. Paired t-tests were used to analyze differences over time. Results: The difference in indices (mental index and panoramic mandibular index) between T0 and T1 was not statistically significant (paired t-test, P>0.05). However, the difference in these indices between T1 and T2 was statistically significant (paired t-test, P<0.05). Conclusion: The cortical thickness of the mandible decreased in the late stage (after 18 months) as observed by panoramic radiograph.

Real-time multiple face recognition system based on one-shot panoramic scanning (원샷 파노라믹 스캐닝 기반 실시간 다수 얼굴 인식 시스템)

  • Kim, Daehwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.553-555
    • /
    • 2022
  • This paper is about a real-time automatic face recognition system based on one-shot panoramic scanning. It detects multiple faces in real time through a single panoramic scanning process and recognizes pre-registered faces. Instead of recognizing multiple faces within a single panoramic image, multiple faces are recognized using multiple images obtained in the scanning process. This reduces the panorama image creation time and stitching error, and at the same time can improve the face recognition performance by using the accumulated information of multiple images. It is expected that it can be used in various applications such as a multi-person smart attendance system with only a simple image acquisition device.

  • PDF

Image quality evaluation for panoramic radiography (임상가를 위한 특집 2 - 파노라마방사선영상의 화질관리)

  • Lee, Sam-Sun
    • The Journal of the Korean dental association
    • /
    • v.52 no.3
    • /
    • pp.139-146
    • /
    • 2014
  • The quality assurance program of a panoramic radiography is been discussed in two ways: phantom image tests and clinical image quality assurance tests. Methods and standards of each of the test are presented, which efforts guarantee a proper quality of image, improve standard of dental care and decrease radiation exposure.

Panoramic Video Generation Method Based on Foreground Extraction (전경 추출에 기반한 파노라마 비디오 생성 기법)

  • Kim, Sang-Hwan;Kim, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.2
    • /
    • pp.441-445
    • /
    • 2011
  • In this paper, we propose an algorithm for generating panoramic videos using fixed multiple cameras. We estimate a background image from each camera. Then we calculate perspective relationships between images using extracted feature points. To eliminate stitching errors due to different image depths, we process background images and foreground images separately in the overlap regions between adjacent cameras by projecting regions of foreground images selectively. The proposed algorithm can be used to enhance the efficiency and convenience of wide-area surveillance systems.

The relationship among reference lines used for taking the extraoral radiography (구외 방사선사진 촬영에 사용되는 기준선의 상호 관계)

  • Lee Sul-Mi;Choi Hang-Moon
    • Imaging Science in Dentistry
    • /
    • v.31 no.4
    • /
    • pp.205-207
    • /
    • 2001
  • Purpose : The aim of present study is to estimate the relationship among reference lines used for taking the extraoral radiography and panoramic radiography. Materials and Methods: Lateral cephalographs of 40 adults, aged 22 to 30 years were taken. Angles between reference lines (Frankfort line, canthomeatal line, infraorbitomeatal line, and occlusal plane) were measured. Results: Angles between Frankfort line and canthomeatal line, Frankfort line and infraorbitomeatal line, Frankfort line and occlusal plane, canthomeatal line and infraorbitomeatal line, canthomeatal line and occlusal plane, and infraorbitomeatal line and occlusal plane were 16.1° (±2.2), 5.8° (±2.4), 8.7° (±3.5), 10.3° (±1.3), 24.8° (±4.0), and 14.5° (±4.4),respectively. Conclusion: Angle between frankfort and canthomeatal line is very different with commonly known angle. Frankfort horizontal reference lines used for panoramic radiography need an exact definition and more accurate standard is needed for the taking of panoramic radiograph.

  • PDF

Position of the mental foramen in a Moroccan population: A radiographic study

  • Chkoura, Ahmed;Wady, Wafaa El
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.71-75
    • /
    • 2013
  • Purpose: This study was performed to determine the position of the mental foramen relative to the apices of the teeth based on panoramic radiographs in a Moroccan population. We also analyzed gender differences and the symmetry of location within individuals. Materials and Methods: Seven hundred ninety-four panoramic radiographs were evaluated with regard to the location and symmetry of the mental foramina in male and female subjects. The results were analyzed using Pearson's ${\chi}^2$ and Fisher's exact test. Results: Of the 794 panoramic radiographs, 377 met the inclusion criteria for at least one side. The mental foramen was located just below the apex of the second premolar in 62.7% of the patients and between the first and second premolars in 30%. It was symmetrically located in 79%. No statistically significant differences were found between males and females in the position and symmetry of the mental foramen. Conclusion: The most common position for the mental foramen in this sample was in line with the second premolar.