• Title/Summary/Keyword: panel test.

Search Result 1,780, Processing Time 0.029 seconds

Field Application of a Precast Concrete-panel Retaining Wall Adhered to In-situ Ground (원지반 부착식 판넬옹벽의 현장 적용성 평가)

  • Min, Kyoung-Nam;Lee, Jae-Won;Lee, Jung-Gwan;Kang, In-Kyu;Ahn, Tae-Bong
    • The Journal of Engineering Geology
    • /
    • v.26 no.1
    • /
    • pp.51-61
    • /
    • 2016
  • New building methods are needed to aid increased inner-city redevelopment and industrial construction. A particular area of improvement is the efficient use of cut slopes, with the minimization of associated problems. A retaining wall of precast panels can resist the horizontal earth pressure by increasing the shear strength of the ground and reinforcing it through contact with the panels. Precast panels allow quick construction and avoid the problem of concrete deterioration. Other problems to be solved include the digging of borrow pits, the disposal of material cut from the slope, and degradation of the landscape caused by the exposed concrete retaining wall.This study suggest the methods of improvement of an existing precast panel wall system by changing the appearance of the panels to that of natural rock and improving the process of adhering the panel to a vertical slope. The panels were tested in the laboratory and in the field. The laboratory test verified their specific strength and behavior, and the field test assessed the panels' ground adherence at a vertical cutting. Reinforcement of the cutting slope was also measured and compared with the results of 3D numerical analysis. The results of laboratory test, identified that the shear bar increase the punching resistance of panel. And as a results of test construction, identified the construct ability and field applicability of the panel wall system adhered to in-situ ground. In addition to that, extended measurement and numerical analysis, identified the long-term stability of panel wall system adhered to in-situ ground.

An Experimental Study on the Warehouse Mock-up Fire Test (창고 모델 실물화재 특성에 대한 실험적 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.47-54
    • /
    • 2010
  • This study is analyze the damage of warehouse fire accident be made through the fire characteristic database of combustibles and real scale fire test of warehouse mock-up. Combustibles fire tests are carried out for database using RCT (Room Corner Tester) to predict fire growth the goods. A mockup ($3m{\times}3m{\times}2.4m$) of clothes warehouse was built and real scale fire test by LSC (Large Scale Calorimeter) base on the fire characteristic DB. The mock-up of clothes warehouse is made of two type sandwich panels (Glass wool, EPS foam sandwich panel). As a mock-up test result, test 1 (Glass wool sandwich panel) and test 2 (EPS foam sandwich panel) indicating fire growth such as 5 MW, 11 MW of maximum HRR (Heat Release Rate).

Comparison of Sound Transmission Loss Through Single and Double with Vacuum Layer Polymer Soundproof Panel (단일 구조 및 진공층이 있는 이중 구조 폴리머 방음패널의 음향투과손실 비교)

  • Lee, Ju Haeng;Kim, Ilho;Ahn, Kwang ho
    • International Journal of Highway Engineering
    • /
    • v.15 no.6
    • /
    • pp.11-15
    • /
    • 2013
  • PURPOSES : This study is to compare sound transmission loss(STL) value depending on the four kinds of materials, PC(Polycarbonate), PMMA(Polymethyl mathacrylate), PE(Polyethlyene), PP(Polypropylene), and two types of structure, single layer and double with vacuum layer, of soundproof panel. METHODS : With four sorts of polymer material, the specimens were made as various structures, 4 mm and 8 mm of single soundpoof panel and vacuum layered 4 mm of one. The experimental condition and procedures were complied with authorized process test, KS F 2808. RESULTS : STL of single panel made of PC were the greatest followed by PMMA, PE, PP regardless of the thickness of panel, However, STL of PMMA panel began to decrease around 2500 Hz and reached the lowest value among others in 5000 Hz. Vacuum layer soundproof panel showed good performance in more than 2000 Hz. Only vacuum layer panel made of PC presented resonance frequency at 800 Hz while that of other vacuum ones at 1000 Hz. CONCLUSIONS : According to results of single layer, it was found that single panel functioned as the theorical way we expected in terms of surface density. That trends were blurred as the panel got thicker. And it was suggested also that vacuum layer panel performed well at high frequency, more than 2000 Hz.

An Experimental Study of Sprinkler system for Sandwich Panel Wall Protection (샌드위치패널 벽면보호용 스프링클러설비 적용 실험)

  • Seo, Dong-Hun;Kim, Won-Hyung;Kim, Jong-Hoon;Lee, Young-Jae
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.37-43
    • /
    • 2017
  • Domestic sandwich panel buildings are widely used on walls and roofs of factories and warehouse facilities. Factory and warehouse facilities have high fire load and rapid spread of fire due to their use characteristics, leading to large fires. Due to the characteristics of materials, walls and roofs are collapsed, resulting in life damage and property damage. In this regard, this study examined domestic and international standards of sprinkler facilities to prevent ignition of sandwich panel walls. Also, in order to check whether the fire was prevented by installing the head on the wall of the sandwich panel, the fire test was carried out with 10 cm, 60 cm, and 120 cm from the wall along the sprinkler head installation standard of domestic fire safety standards. As a result of the fire test, it was confirmed that the sandwich panel was prevented from igniting when the head of water pressure 0.1 MPa and water quantity K-80 was installed. According to the separation distance, it was impossible to measure the temperature at 10 cm, but at 60 cm, At the maximum temperature of $525^{\circ}C$ and 120 cm, the maximum temperature of the wall of the sandwich panel was measured as $276^{\circ}C$. As a result of the fire test, considering the fire point of 450 degrees Celsius in the fire test of the sandwich panel, the distance from the sandwich panel wall to the combustible is more than 120 cm.

A Study of Optical Properties of Assembled Plasma Display Panel with 3-D Optical Code

  • Park, Hyun-Myung;Kang, Jungwon
    • Journal of the Semiconductor & Display Technology
    • /
    • v.11 no.1
    • /
    • pp.67-71
    • /
    • 2012
  • The optical properties of PDP, such as the transmittance and reflectance, were analyzed with 3D optical code. Three different ITO-less structures in the front panel are examined. In the assembled panel study, the test 1 structure shows 16.6% and 10.2% higher reflectance than the structures of tests 2 and 3, respectively. In order to check the validation of the simulation result, three 7.5-inch test panels having the same geometry and property are fabricated as simulation models. The calculated reflective properties are compared to the measured data from real panels. The relative difference extracted from the simulation and measurement methods is less than 4.9% and are well matched.

Density and Thermal Conductivity Property of the Lightweight Composite Panel Core According to Pearlite Replacement ratio (펄라이트 치환율에 따른 경량복합패널 심재의 밀도 및 열전도율 특성)

  • Kim, Heon-Tae;Jung, Byeong-Yeol;Lee, Sang-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.11a
    • /
    • pp.175-176
    • /
    • 2014
  • Recently, in the apartment house of our country, office building, apartment, and etc, the lightweight composite panel is much used as the partition wall body. This is due to be very convenient when the execution and dismantling is convenient and it forms the space which the consumer in the space desires. Therefore, in this research, the thermal conductivity property of the lightweight composite panel core according to the replacement ratio variation of the pearlite tries to be analyze. As the density test result and replacement ratio of the pearlite increased, the density showed the tendency to rise. the replacement ratio of the pearlite increased, the absorption rate showed the tendency to fall. And this is determined that absorption rate is degraded due to the increase in the density. the thermal conductivity test result and pearlite replacement ratio increased, the tendency that the thermal conductivity increases was represented.

  • PDF

Technology Innovation, Human Capital and R&D Effects on Economic Growth

  • Lim, Woo-Ri;Yi, Chae-Deug
    • International Area Studies Review
    • /
    • v.21 no.1
    • /
    • pp.201-219
    • /
    • 2017
  • This paper analyzes the economic effects of the S&T Innovation, R&D, human resources and investment on the economic growth using 18 countries. We have obtained the somewhat mixed results on the existence of unit root roots in variables. While most of Pedroni cointegration tests show that there are no panel cointegration among the variables, Kao cointegration test shows that there is the panel cointegration among the variables such as GDP, human capital, R&D investment and patent. Kao cointegration test result shows that human capital, R&D investment, patent economic growth seem to have the panel cointegration or the long-run relationship among them as a whole. The estimation results of individual OLS and panel estimation show that the human capital, R&D investment and technology innovation or patent had positively significant effects on economic growth or GDP.

PanelLink Digital Flat Panel Display Transmitter for TFT LCD Test (TFT LCD 검사용 패널링크 디지털 플랫 패널 디스플레이 송신부 구현)

  • Lee, Seon-Bok;Baek, Woon-Sung;Park, Chang-Soo;Hong, Cheol-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.621-623
    • /
    • 1998
  • We implemented PanelLlnk digital flat panel display transmitter supporting SXGA($1280{\times}1024$) resolution. It can transmit data through 10m cable at XGA($1024{\times}768$) resolution and through 7m cable at SXGA($1280{\times}1024$). We also found resistor value to get stable display image by low voltage differential signal swing control.

  • PDF

Tests for Panel Regression Model with Unbalanced Data

  • Song, Suck-Heun;Jung, Byoung-Cheol
    • Journal of the Korean Statistical Society
    • /
    • v.30 no.3
    • /
    • pp.511-527
    • /
    • 2001
  • This paper consider the testing problem of variance component for the unbalanced tow=-way error component model. We provide a conditional LM test statistic for testing zero individual(time) effects assuming that the other time-specific(individual)efefcts are present. This test is extension of Baltagi, Chang and Li(1998, 1992). Monte Carlo experiments are conducted to study the performance of this LM test.

  • PDF

3-Dimensional Precision Measurement of Spacecraft Structure Test Model (위성체 구조시험 모델의 3차원 정밀 측정)

  • 윤용식;이중엽;조창래;이상설
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.131-134
    • /
    • 2001
  • The three-dimensional precision measurement technology for industry product of middle and/or large scale has been developed. Theodolite measurement system which is one of the technology is widely used in aerospace industry. This paper describes measurement method and results for spacecraft structure test model by using the measurement system. And structural stability for STM is desribed through the comparison between design values and measured values.

  • PDF