• Title/Summary/Keyword: panel test.

Search Result 1,792, Processing Time 0.024 seconds

Highly Sensitive and Transparent Touch Sensor by a Double Structure of Single Layer Graphene

  • Kim, Youngjun;Jung, Hyojin;Jin, Hyungki;Chun, Sungwoo;Park, Wanjun
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.228.2-228.2
    • /
    • 2014
  • Characteristics of high Fermi velocity, high mechanical strength, and transparency offer tremendous advantages for using graphene as a promising transparent conducting material [1] in electronic devices. Although graphene is a prospective candidate for touch sensor with strong mechanical properties [2] and flexibility, only few investigations have been carried out in the field of sensor as a device form. In this study, we suggest ultra-highly sensitive and transparent graphene touch sensor fabricated by single layer graphenes. One of the graphene layers is formed in the top panel as a disconnected graphene beam transferred on PDMS, and the other of the graphene layer is formed with line-patterning on the bottom panel of triple structure PET/PI/SiO2. The touch sensor shows characteristics of flexible. Its transmittance is approximately 75% where transmittance of the top panel and the bottom panel are 86.3% and 87%, respectively, at 550 nm wavelength. Sheet resistance of each graphene layer is estimated as low as $971{\Omega}/sq$. The results show that the conductance change rate (${\Delta}C/C0$) is $8{\times}105$ which depicts ultra-high sensitivity. Moreover, reliability characteristic confirms consistent behavior up to a 100-cycle test.

  • PDF

A Study on the Development of the Console with LCD Panel for Exterior Advertizing (LCD 패널을 탑재한 옥외 광고용 콘솔 개발에 관한 연구)

  • Choi, Kab-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.1
    • /
    • pp.13-20
    • /
    • 2010
  • The development of the console for exterior advertizing LCD Panel(LCD Console) is the purpose of this study with regard to importance of display industry. In this study, the most important point is to develop the cooling system for LCD Console. It is developed by using systematic application techniques and statistical tests and analysis to integrate commercial components, cooling fan, heat sink, thermo electronic modules etc, of it. This study, at first, shows design/manufacturing process of the cooling system and the setting process of control factors to control through experimentation. Next, after constructing the complete console, 46 inch LCD Panel and the cooling system are built in, the performance test of it is shown through experimentation.

Dynamic Analysis of the PDLC-based Electro-Optic Modulator for Fault Identification of TFT-LCD (박막 트랜지스터 기판 검사를 위한 PDLC 응용 전기-광학 변환기의 동특성 분석)

  • 정광석;정대화;방규용
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.4
    • /
    • pp.92-102
    • /
    • 2003
  • To detect electrical faults of a TFT (Thin Film Transistor) panel for the LCD (Liquid Crystal Display), techniques of converting electric field to an image are used One of them is the PDLC (polymer-dispersed liquid crystal) modulator which changes light transmittance under electric field. The advantage of PDLC modulator in the electric field detection is that it can be used without physically contacting the TFT panel surface. Specific pattern signals are applied to the data and gate electrodes of the panel to charge the pixel electrodes and the image sensor detects the change of transmittance of PDLC positioned in proximity distance above the pixel electrodes. The image represents the status of electric field reflected on the PDLC so that the characteristic of the PDLC itself plays an important role to accurately quantify the defects of TFT panel. In this paper, the image of the PDLC modulator caused by the change of electric field of the pixel electrodes on the TFT panel is acquired and how the characteristics of PDLC reflect the change of electric field to the image is analyzed. When the holding time of PDLC is short, better contrast of electric field image can be obtained by changing the instance of applying the driving voltage to the PDLC.

Monetary Policy Independence and Bond Yield in Developing Countries

  • ANWAR, Cep Jandi;SUHENDRA, Indra
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.11
    • /
    • pp.23-31
    • /
    • 2020
  • This paper investigates the impact of monetary policy independence shock on bond yield by allowing for heterogeneous coefficients in the model based on panel data for 19 developing countries using quarterly data from 1991 to 2016. First, we estimate the model using conventional panel VAR estimation with the assumption of homogeneous coefficients across countries. Second, by performing Chow and Roy-Zellner tests to check the homogeneity assumption, we find that the assumption does not hold in the model. Third, we apply a mean-group estimation for panel VAR as a solution for heterogeneity panel model. The results reveal that central bank independence is effective in reducing bond yield with the maximum at period 6 after the shock. Shock one standard deviation bond yield has a negative effect on consumption and investment. We determine that central bank independence has a contradictory effect on real activity; a negative effect on consumption but a positive influence on investment for the first two years after the shock. Additionally, we split our sample into three groups to make the subgroups pool. Our empirical result shows that monetary policy independence shock reduces bond yield. Meanwhile, the response of economic activity to bond yield varies for all three groups.

Performance Evaluation of Water Vapour Adsorption & Desorption Properties of Ceramic Panel and Painting Materials for Humidity Control (습도조절용 세라믹패널 및 도료의 흡·방습성능 평가)

  • Jang, Kun-Young;Ryu, Dong-Woo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.3
    • /
    • pp.43-52
    • /
    • 2018
  • This study is conducted to evaluate the performance of ceramic panels and painting materials for humidity control which are developed in non-plastic room temperature hardening structure as part of a project to improve a residential environment for the low-income class, rather than the performance of high-priced humidity control materials that are produced with the existing plasticity processing. The testing methods included the measurements of absorption & desoprtion of humidity per material; Mock-up Testing; an evaluation method of comparing the absorption & desoprtion performances of Ecocarat, ceramic panels and painting materials through Living Lab. According to the measurements of absorption & desoprtion per material, ceramic panels, E panel, and ceramic painting material showed 73.3g/m2, 96.6g/m2, and 111.1g/m2, respectively. That is, the performance of humidity control of each material was found to be good in the order of: Ceramic Paint > E panel > Ceramic Panel. According to performance evaluation testing with Mock-up test and Living Lab, Ceramic Paint, Ecocarat, and Ceramic Panels showed better absorption & desoprtion performances in the order.

The COVID-19 Pandemic and Instability of Stock Markets: An Empirical Analysis Using Panel Vector Error Correction Model

  • ABDULRAZZAQ, Yousef M.;ALI, Mohammad A.;ALMANSOURI, Hesham A.
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.9 no.4
    • /
    • pp.173-183
    • /
    • 2022
  • The objective of this research is to examine the influence of the COVID-19 pandemic on stock markets in a few developing and developed countries. This study uses daily data from January 2020 to May 2021 and obtained from World Health Organization and Thomson Reuters. The secondary data was evaluated through panel econometric methodology that includes different unit root tests, and to analyze the long-run relationship between variables, panel cointegration techniques were applied. The long-run causality among variables was examined through Panel Vector Error Correction Model. The overall findings of this study suggest a long-run association exists between several cases and death with the stock returns of the GCC and other stock markets. Furthermore, the VECM model also identified a long-run causality running from COVID cases and death towards the stock rerun of both sets of stock markets. However, a subsequent Wald test yielded mixed results, indicating no short-run causality between cases and deaths and stock returns in both groups; however, in the case of GCC, several COVID-19 cases are having a causal impact on stock markets, which is notable in light of the fact that the death rate in GCC is significantly lower than in many developed and developing countries.

A Study on Fire Hazards in Multiple Compartments with Lightweight Partition Walls (경량칸막이 벽체를 통한 다중구획공간에서의 화재위험성에 관한 연구)

  • Park, Sang-Min;Choi, Su-Gil;Jin, Se-Young;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.14-21
    • /
    • 2020
  • This paper presents the study of a fire risk to the backside of two miniatures of ISO 9705 2/5 using a lightweight partition for indoor space division and reproduction of the ISO 9705 test. An SGP partition, stud partition, glass wool panel, urethane foam panel, sandwich panel, and glass partition were selected as the test specimens, which are frequently used in construction. According to the ISO 9705 test standard, stabilization was achieved using a measuring device that recorded data before the ignition of a burner and continued recording for 120 s thereafter. After ignition was achieved, the power was increased to 300 kW for 600 s and then reduced to 100 kW for 600 s. The specimens were subsequently observed for 180 s, and the fire risk to the backside and the fire pattern of the wall unit were analyzed. Owing to the amount of heat generated by the ignition source, the maximum temperature of the backside was observed to be 67.7 ℃ for the SGP partition, 55.1 ℃ for the stud partition, 52.4 ℃ for the glass wool panel, 727.4 ℃ for the sandwich panel, 561 ℃ for the urethane foam panel, and 630.5 ℃ for the glass partition. In the cases of the sandwich and urethane foam panels, the explosion of flammable gas occurred by virtue of fusion of the interior materials. The reinforced glass was fractured owing to the temperature difference between the heat- and nonheat-responsive parts. Ultimately, the fire risk to the nearby section room was deemed to be high.

Availability of CLSI method and MicroScan MICroSTREP plus panel for Antimicrobial Susceptibility Testing of α-hemolytic streptococci Isolated from Patients (환자(患者)에서 분리한 연쇄상구균(連鎖狀球菌)에 대한 CLSI방법(方法)과 MicroScan MICroSTREP plus panel의 항균제(抗菌劑) 감수성(感受性) 검사(檢査)의 유용성(有用性) 고찰(考察))

  • Kim, Sang-Ha;Kim, Sang-Ha;Kim, Young-Kwon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4951-4958
    • /
    • 2011
  • The purpose of this study was availability for the classical test method. The test were called CLSI(Clinical and Laboratory Standards Institute) that was disk diffusion method, the newly designed E-test(made use disk diffusion method) can estimate the MIC and modified broth microdilution method that was standardized. Those tests were observed by MicroScan MicroSTREP plus panel. Target strains were 53 strains of S.pneumoniae and 51 strains of ${\alpha}$-hemolytic streptococci which were separated from the inpatient in university hospital for 6 months from February to August, 2009. The 9 antimicrobial agent of target evaluation were cefotaxime, chloramphenicol, clindamycin, erythromycin, levofloxacin, penicillin, tetracycline, trimethoprim/sulfamethoxazole, and vancomycin. researched comparative analysis both S.pneumoniae and ${\alpha}$-hemolytic streptococci. The result of the high concordance rates in ${\alpha}$-hemolytic streptococci was recognized formally in clinical microbiology laboratory.

An Experimental Study on the Performance Evaluation Method of Padder Roll by Hydraulic Multi Cell with Acceleration Test (유압제어식 멀티셀 패더롤의 가속시험을 통한 성능평가 기법 연구)

  • Cho, Kyung Chul;Lee, Eun Ha;Park, Si Woo;Kim, Soo Youn
    • Journal of Drive and Control
    • /
    • v.15 no.3
    • /
    • pp.43-48
    • /
    • 2018
  • The hydraulic control valve, used in the CPB (cold-pad-Batch) cold dyeing system, passes through a pressurized material that absorbs the dye. The hydraulic control of the hydraulic control panel shall be driven in a uniform and precisely controlled manner, as it interferes directly with the dyschromatism. In this study, an acceleration test model was employed to verify the durability of the hydraulic control of the hydraulic control panel, which was manufactured by the scenic model, and the pre-roll angle was analyzed before the performance of acceleration test. Based on the change in the amount of deformation of the padder roll the durability of the padder roll was analyzed along with verification of the durability of the skin and the rubber coating in contact with the fabric. Furthermore, the accelerated test method used for hydraulic controlled multi-cell padder rolls was verified.

Development of Simple Test Method using VOC Analyzer to Measure Volatile Organic Compounds Emission for Particleboards (VOC Analyzer를 이용한 파티클보드로부터 방산되는 휘발성유기화합물의 간이 측정방법 개발)

  • An, Jae-Yoon;Kim, Sumin;Kim, Jin-A;Kim, Hyun-Joong;Mun, Suck-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.4
    • /
    • pp.22-30
    • /
    • 2006
  • The volatile organic compound (VOC) Analyzer is a portable device to measure the four main aromatic hydrocarbon gases: toluene, ethylbenzene, xylene and styrene. With the VOC Analyzer, a semiconductor gas sensor eliminates the need for the carrier gas which is required for conventional gas chromatographs. In addition, since the semiconductor gas sensor is supersensitive to gas components, it is not necessary to use a conventional gas concentrator or other complicated equipment. Compared with other measurement methods, the VOC analyzer is useful for measuring toluene, ethylbenzene, xylene and styrene in wood-based panel because of its ease in obtaining field results and repeating the test. The VOC Analyzer primarily measures four VOC in the air. In this study, we designed a test method of VOC measurement for particle board. A specimen was sealed in 3L polyester bag, after 96hours we could measure maximum VOC emission level that is a stabilized VOC Value. For easy, fast and economic testing of TVOC emission from wood-based panel, we developed the test method with the VOC Analyzer. The VOC Analyzer is expected to gain widespread use in the manufacturing field where a quick and easy test for VOC emission from wood-based panel is required. Furthermore, the VOC Analyzer promises to become an easier, faster and more economic technique than the currently used standard methods.