• Title/Summary/Keyword: panel performance

Search Result 1,532, Processing Time 0.033 seconds

Performance Evaluation of Softwood Plywood as Structural and Concrete-Form Panels (침엽수 합판의 구조용 및 콘크리트 거푸집용으로서의 성능 평가)

  • Lee, Jun-Jae;Kim, Gwang-Chul;Lee, Guk-Sik
    • Journal of the Korean Wood Science and Technology
    • /
    • v.28 no.3
    • /
    • pp.14-24
    • /
    • 2000
  • In present research, the plywoods made of radiata pine or Japanese larch, the potential softwood species in mass supply, were discussed to examine their feasibility as the structural and concrete form panels through the basic properties test. First, plywood qualities and its nail performance were tested. The performance test for concrete form or structural panel by concentrated and uniformly distributed load were conducted to investigate the possibility as structural material for light frame and concrete constructions. Test results of basic quality such as specific gravity, cupping, bowing, and twisting appeared to satisfy the criteria for structural use. Also, nail performance test results, for roof and wall sheathing panels, nail lateral resistance, nail withdrawal resistance, and nail push head resistance proved to meet the required standard for structural use. The test results on performance as structural panel by concentrated and uniformly distributed load and as concrete form panel showed that these two species could be used for structural sheathing, subfloor, and concrete form panels.

  • PDF

Evaluation of Seismic Performance in Relation to Beam-Panel Zone Strength Ratio of CFT Column to H-beam Endplate Connections (CFT 기둥-H형강보 엔드플레이트 접합부의 보-패널존 강도비에 따른 내진성능 평가)

  • Kim, Young Ju;Kim, Jae Keon;Oh, Young Suk;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.769-777
    • /
    • 2000
  • This paper presents the results of cyclic seismic performance in relation to beam-panel zone strength ratio of CFT Column to H-beam steel moment connections. Each test specimen consisted of $H-350{\times}175{\times}7{\times}11$ beam(SS400) and ${\boxe}-250{\times}250{\times}9$, ${\boxe}-250{\times}250{\times}12$ column(SPSR400). Main parameter is a column panel zone strength relative to beam strength. Energy absorption capacity available in the specimens ranged from 5.2 to 12.7(tm). If panel zone strength relative to beam strength is too strong or weak, the energy absorption capacity tended to be inferior. About steel moment-resisting frame, the test results of this experiment seem to support the investigation that permitting panel zone yielding shall be more advantageous to enhancing total seismic performance.

  • PDF

Performance Evaluation of Curtain-Wall Applying Light-weight Inorganic Foam Panel (경량 무기 발포패널을 적용한 커튼월의 성능평가)

  • Shin, Hyeon-Uk;Song, Hun;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.211-212
    • /
    • 2012
  • To prevent energy waste in buildings used heat insulator. Heat insulator materials can be classified inorganic and organic. The organic material is due to toxic gas emission, when a fire occurs. And it has lower water resistance. The inorganic material is heavy and worse thermal performance than organic materials. Technologies on energy saving and materials used in curtain walls have progressed with increase of high-rise and large buildings. However, there is little study to explain fire resistance performance of the curtain walls. This study focused on evaluation of the physical properties of light-weight inorganic foam panel for using industrial by-products materials and performance evaluation by mock up test.

  • PDF

A Study on the Sound Insulation Performance of the Composite Panel for Railroad Vehicle (철도차량용 복합 내장 패널의 차음성능에 관한 연구)

  • 김봉기;김재승;황병선;이상진
    • Proceedings of the KSR Conference
    • /
    • 2002.10a
    • /
    • pp.182-187
    • /
    • 2002
  • Since most of main noise sources of the railroad vehicle are transmitted to the passenger's ear through the vibration of the panel, the insulation performance of the panels should be high enough to protect the passengers from the noisy environment. Specifically, the composite materials which are generally used for reducing the weight of the vehicle compartment have the low insulation performance, noise control actions should be taken appropriately by considering the insulation performance of the panels. In this study, the insulation performances of the inner/outer panels were evaluated and the contribution of the aluminum door was estimated compared to the composite panels. The results can furnish an indepth understanding of the insulation characteristics of the panel of railroad vehicle.

  • PDF

The Performance Evaluation of Public Municipal Hospitals: Data Envelopment Analysis and Panel Analysis (지방의료원의 성과분석: Data Envelopment Analysis와 패널분석)

  • Chung, Eun-Young;Seo, Young-Jun;Lee, Hae-Jong
    • Health Policy and Management
    • /
    • v.25 no.4
    • /
    • pp.295-306
    • /
    • 2015
  • This study aims to examine the performance of public municipal hospitals through the analysis of data envelopment analysis, efficiency, profitability, and publicness by using panel data during period from 2006 to 2010. The main findings of the study are as follows. First, as a result of efficiency analysis during the period from 2006 to 2010, it was revealed that the number of staff by each job category, labor cost ratio, the number of operating beds need to be decreased. Second, the performance data represented by the indicators of efficiency, profitability and publicness were complementary and showed a tendency of being increased or decreased in same direction. Third, from the result of panel analysis, the efficiency was mainly influenced by the structural factors, while the profitability was influenced by managerial factors, and the publicness by medical environment. In conclusion, in order to enhance the performance of public municipal hospitals in Korea, it is important to harmonize the effort for efficiency, financial and policy support by central and local government, and the continuous participation of community residents.

Performance Evaluation on Static Loading and Cyclic Loading for Structural Insulated Panels (구조용단열패널의 정적가력과 반복가력 성능 평가)

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Choi, Sung-Mo
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.4 no.1
    • /
    • pp.33-39
    • /
    • 2013
  • Structural insulated panels, structurally performed panels consisting of a plastic insulation bonded between two structural panel facings, are one of emerging products with a viewpoint of its energy and construction efficiencies. These components are applicable to fabricated wood structures. In Korea, there are few technical documents regulated structural performance and engineering criteria in domestic market. This study was conducted to identify fundamental performance of both monotonic load and quasi static cyclic load for SIPs in shear wall application. Static test results showed that maximum load was 44.3kN, allowable shear load was 6.1kN/m, shear stiffness was 1.23 M N/m, and ductility ratio was 3.6. Cyclic test was conducted by two kinds of specimens : single panel and double panels. Cyclic test results, which were equivalent to static test results, showed that maximum load was 45.42kN, allowable shear load was 6.3kN/m. Furthermore the accumulated energy dissipation capability for double panels was as 2.3 times as that for single panel. From performance of structural tests, it was recommended that the allowable shear load for panels was at least 6.1kN/m.

The Impact of Housing Price on the Performance of Listed Steel Companies Evidence in China

  • Huang, Shuai;Shin, Seung-Woo;Wang, Run-Dong
    • Asia-Pacific Journal of Business
    • /
    • v.11 no.2
    • /
    • pp.27-43
    • /
    • 2020
  • Purpose - This study explores the impact of the real estate industry on related industries for the perspective of Chinese steel companies. Design/methodology/approach - The impact of housing prices on the 41 listed steel companies' performance was analyzed by using the panel data model. We used two kinds of housing price indexes that are set in the panel data models to estimate the range of the real estate market, driving the performance growth of steel listed companies. Moreover, the net profit of steel companies is used as the dependent variable. To test the stability of the model, ROA used as a dependent variable for the robustness test. Also, to avoid the time trend of housing prices, this paper selects the growth rate of housing prices as the primary research variable. After Fisher-type testings, there is no unit root problem in both independent and dependent variables. Findings - The results indicated that the rise in the housing price has a positive influence on the steel company performance. When the housing price increases by 1%, the net profit of steel enterprises will increase by 5 to 20 million yuan. Research implications or Originality - In this paper, empirical data at the micro-level and panel model are used to quantify China's real estate industry's driving effect on the iron and steel industry, providing evidence from the microdata level. It helps us to understand further the status and role of China's real estate industry in the economic structure.

Prediction of Steady Performance of a Propeller by Using a Potential-Based Panel Method (포텐셜을 기저로한 패널법에 의한 프로펠러의 정상 성능 해석)

  • Kim, Young-Gi;Lee, Jin-Tae;Lee, Chang-Sup;Suh, Jung-Chun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.30 no.1
    • /
    • pp.73-86
    • /
    • 1993
  • This paper describes a potential-based panel method for the prediction of steday performance of a marine propeller operating in a uniform oncoming flow. An integral equation with unknown dipole strengths is formulated by distributing the normal dipoles and/or sources on the blade and hub surfaces and the wake sheet, and is solved numerically upon discretization. A hyperboloidal panel has been adopted to compute the potential induced by a normal dipole on a non-planar quadrilateral panel. The Kutta condition is satisfied by iteratively annulling the pressure jumps at the trailing edge. Extensive convergence tests are carried out, and the influence of the wake model upon performance is studied. Predicted performance is shown to correlate well with the experiments.

  • PDF

The Effects of AEO Certification on Firm's Performance : Panel Data Analysis (AEO 인증이 기업성과에 미치는 영향 : 패널데이터 분석)

  • Ha, Eui-Hyun
    • Korea Trade Review
    • /
    • v.41 no.4
    • /
    • pp.91-110
    • /
    • 2016
  • AEO certification has a positive effect on firm's performance. Therefore, this study analyzed the effect of AEO certification on firm's performance using panel data analysis for firm to have international competitiveness. It uses the Hausman-Taylor test for effective solutions of endogenous matter. In terms of the result of analysis, AEO certification has a positive effect on domestic and foreign sales, especially direct benefit and business process improvement of AEO certification have a positive effect on domestic and foreign sales through the improvement of international logistics flow. In conclusion, this study proposes the policy of AEO certification by analyzing the effect of AEO certification on firm's performance by using the panel data analysis.

  • PDF

Effects on Performance of Deployable Solid Antenna for Panel Misalignment (패널오차에 의한 전개형 솔리드 안테나 성능 영향)

  • Lee, Ji-Yong;Lee, Kyo-Il;Yoon, Seong-Sik;Lee, Taek-Kyung;Lee, Jae-Wook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.28 no.8
    • /
    • pp.603-609
    • /
    • 2017
  • In the deployable solid surface antennas, the effects on the performances of antenna due to the structural errors that occur during the deployment are analyzed. The deployable solid surface antennas employed in a satellite are launched in folded configuration and those are deployed in the space environment, and the effects on the antenna performance are calculated depending on the type of surface errors. When the deviation error occurs in one panel, the degradation of performance appears in the side where the incomplete deployment of panel occurs. By assuming that the panel error distribution is in cosine function, the effect of errors are calculated and analyzed with regard to the types and the magnitude of the error. If the antena panel error is uniform, the gain is reduced and pattern is symmetric. For the panel error of cosine 1 or 3 cycle, the main lobe tilts while the pattern is symmetric and the gain reduces for 2 or 4 cycle error.